Skip to content

The TAP2500 and TAP3500 are single-ended active FET probes engineered to deliver truer signal reproduction and fidelity for high-frequency measurements. Built around an ultra-low input capacitance and a dedicated probe interface, they address three traditional probing problems: lowering DUT loading effects, providing versatile connectivity for attaching to small surface-mount devices, and preserving oscilloscope bandwidth at the probe tip for DPO7000 and DPO4000 Series oscilloscope models up to 3.5 GHz.
These active probes are intended for the verification, debug, and characterization of high-speed designs, as well as signal integrity, jitter, and timing analysis. They also serve manufacturing engineering and test, and are suited to measuring signals with voltage swings up to 8 Vpk-pk.
ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit we sell is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer. Operating since 1992, ValueTronics keeps a deep, ready-to-ship selection of test and measurement equipment on hand so engineers can source the right instrument quickly.
The TAP2500 and TAP3500 form a two-model line of single-ended active FET probes that share a common architecture and interface while differing in bandwidth and rise time. Both are built for high-speed signal acquisition with ultra-low input capacitance and a TekVPI connection to compatible host oscilloscopes.
Across the line, the probes deliver the same ≤0.8 pF input capacitance, 40 kΩ input resistance, 10:1 attenuation, and –4 V to +4 V input dynamic range. The distinction between the two models is the bandwidth and rise-time tier each one targets.
Each pre-owned model below is its own dedicated product page with condition-matched pricing. Select the bandwidth tier that fits your application, and review that model's page for its specific pre-owned availability and specifications.
The two models separate on headline speed: the TAP2500 provides a probe-only bandwidth of ≥2.5 GHz with a rise time of <140 ps, while the TAP3500 extends to ≥3.5 GHz with a faster rise time of <130 ps. All other electrical and mechanical characteristics — input capacitance, input resistance, attenuation, dynamic and offset ranges, and maximum input voltage — are common to both.
Use the comparison table below to match the bandwidth and rise-time tier to your application; the two models are otherwise identical in their input and mechanical specifications.
| Model | Bandwidth | Rise Time | Attenuation |
|---|---|---|---|
| TAP3500 | ≥3.5 GHz | <130 ps | 10:1 |
| TAP2500 | ≥2.5 GHz | <140 ps | 10:1 |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Characteristics | |
| Bandwidth (probe only) | ≥3.5 GHz |
| Attenuation (probe only) | 10:1 |
| Rise Time (probe only) | <130 ps |
| Input Capacitance | ≤0.8 pF |
| Input Resistance | 40 kΩ |
| Input Dynamic Range | –4 V to +4 V |
| Input Offset Range | –10 V to +10 V |
| Max Input Voltage (non-destruct) | ±30 V (DC + pkAC) |
| Propagation Delay | 5.3 ns |
| Physical Characteristics | |
| Width | 7.6 mm (0.30 in.) |
| Height | 7.6 mm (0.30 in.) |
| Depth | 57.2 mm (2.25 in.) |
| Cable Length | 1300 mm (51 in.) |
| Net Weight | 0.091 kg (0.2 lbs, probe only, using ME lab scale) |
| Power Requirements | |
| Power | Powered directly by the DPO7000 and DPO4000 Series Oscilloscopes using TekVPI probe interface |
| Environmental | |
| Temperature, Operating | 0° C to +50° C |
| Temperature, Non-operating | –40° C to +71° C |
| Humidity, Operating | 5% to 95% RH at up to +30 °C; 5% to 85% RH above +30 °C up to +50 °C; non-condensing |
| Humidity, Non-operating | 5% to 95% RH at up to +30 °C; 5% to 85% RH above +30 °C up to +75 °C; non-condensing |
| Altitude, Operating | Up to 4,400 m (15,000 feet) |
| Altitude, Non-operating | Up to 12,192 m (40,000 feet) |
| Regulatory | |
| Emissions Compliance | EN 55011, Class A |
| Compliance Labeling | C-Tick (Australia/New Zealand), CE (European Union), WEEE (European Union) |
Important: Maximum input voltage (non-destruct): ±30 V (DC + pkAC).
Important: The TAP2500 and TAP3500 are powered directly by, and require, a Tektronix DPO7000 or DPO4000 Series oscilloscope with the TekVPI probe interface; the probes do not operate standalone.
Recommended pairing: use the TAP2500 or TAP3500 with DPO7000 or DPO4000 Series oscilloscopes equipped with the TekVPI probe interface, which also supplies probe power.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Tektronix
Condition
Pre-Owned
Manufacturer
Tektronix
Act_prob_freq
3.5 GHz
MDO3104 Tektronix Mixed Domain Oscilloscope Used
MDO3104
MDO3102 Tektronix Mixed Domain Oscilloscope Used
MDO3102
MDO3054 Tektronix Mixed Domain Oscilloscope Used
MDO3054
MDO3034 Tektronix Mixed Domain Oscilloscope Used
MDO3034
MDO3052 Tektronix Mixed Domain Oscilloscope Used
MDO3052
MDO3032 Tektronix Mixed Domain Oscilloscope Used
MDO3032
MDO3024 Tektronix Mixed Signal Oscilloscope Used
MDO3024
TDP3500 Tektronix Differential Probe Used
TDP3500
MDO3014 Tektronix Mixed Domain Oscilloscope Used
MDO3014
TDP1000 Tektronix Differential Probe Used
TDP1000
TDP1500 Tektronix Differential Probe Used
TDP1500
MDO3022 Tektronix Mixed Domain Oscilloscope Used
MDO3022
TCP0030A Tektronix Current Probe Used
TCP0030A
TDP0500 Tektronix Differential Probe Used
TDP0500
MDO3012 Tektronix Mixed Domain Oscilloscope Used
MDO3012
THDP0100 Tektronix Differential Probe Used
THDP0100
TAP1500 Tektronix Active Probe Used
TAP1500
TCP0020 Tektronix Current Probe Used
TCP0020
TMDP0200 Tektronix Differential Probe Used
TMDP0200
THDP0200 Tektronix Differential Probe Used
THDP0200
TPP1000 Tektronix Voltage Probe Used
TPP1000
MDO3COMP Tektronix Module Used
MDO3COMP
MDO3USB Tektronix Module Used
MDO3USB
TPP0500B Tektronix Voltage Probe Used
TPP0500B
TPP0250 Tektronix Voltage Probe Used
TPP0250
Request A Quote