Skip to content

The Tektronix P5200, P5205, and P5210 High Voltage Differential Probes are active differential probes that let users safely make measurements of floating circuits while keeping the oscilloscope grounded. Each probe converts floating signals into low-voltage, ground-referenced signals that can be displayed safely and easily on any ground-referenced oscilloscope. The P5200 can be used with any oscilloscope; the P5205 and P5210 connect to Tektronix oscilloscopes through the TEKPROBE interface or to any oscilloscope by way of the 1103 TEKPROBE Power Supply.
These probes are built for floating measurements in power-electronics work. Listed applications include switching power supply design, motor drive design, electronic ballast design, CRT display design, power converter design and service, and power device evaluation. The P5205, a 100 MHz active differential probe, is designed to capture fast rise times in floating circuits and can safely measure voltages in IGBT circuits such as motor drives and power converters.
ValueTronics stocks this equipment in our own 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.
Tektronix, Inc. has retained its brand name throughout its corporate history. It was acquired by Danaher Corporation in 2007 and became part of Fortive Corporation when Fortive was spun off from Danaher in 2016.
The P5200, P5205, and P5210 make up Tektronix's High Voltage Differential Probe family. All three are active differential probes that convert floating signals into low-voltage, ground-referenced signals so they can be displayed safely on a grounded oscilloscope, and all three offer switchable attenuation and a switchable bandwidth limit.
Within the family the models differ in bandwidth, differential and common mode voltage ratings, attenuation factors, input resistance, and power source. The P5200 operates from an AC wall adapter and works with any oscilloscope, while the P5205 and P5210 are powered from the TEKPROBE Power Supply and connect through the Tektronix TEKPROBE interface.
Each model below is its own dedicated product page with pre-owned-matched pricing. Select the model that fits your bandwidth and voltage requirements, then choose the listing that matches the condition you need.
The P5200 is the most broadly compatible member of the family: it runs from an AC wall adapter and can be used with any ground-referenced oscilloscope, rather than requiring the TEKPROBE interface used by the P5205 and P5210.
The clearest differences are bandwidth and voltage. Bandwidth is 25 MHz on the P5200, 100 MHz on the P5205, and 50 MHz on the P5210. The P5210 carries the highest voltage ratings — 4400 V differential (RMS or DC), 5600 V differential peak, and 2200 V CAT II / 1000 V CAT III common mode — while the P5200 and P5205 are each rated 1000 V CAT II differential, 1300 V differential peak, and 1000 V CAT II / 600 V CAT III common mode. See the comparison table for the full row-by-row figures.
Attenuation, input resistance, and power source also vary. The P5200 and P5205 use 50X/500X switchable attenuation with 4 MΩ input resistance per input, whereas the P5210 uses 100X/1000X attenuation with 8 MΩ input resistance per input. The P5200 is powered by an AC wall adapter; the P5205 and P5210 are powered by the TEKPROBE Power Supply. CMRR (80 dB / 50 dB typical) and 7 pF input capacitance are shared across all three.
| Model | Bandwidth | Max Differential Voltage (Peak) | Max Common Mode Voltage |
|---|---|---|---|
| P5200 | 25 MHz | 1300 V | 1000 V CAT II |
| P5205 | 100 MHz | 1300 V | 1000 V CAT II |
| P5210 | 50 MHz | 5600 V | 2200 V CAT II |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Characteristics | |
| Bandwidth (–3 dB) | 25 MHz |
| Differential Mode Voltage (RMS or DC) (between positive and negative input leads) | 1000 V CAT II |
| Differential Mode Voltage (Peak) (between positive and negative input leads) | 1300 V |
| Common Mode Voltage (RMS or DC + Pk AC) (between positive lead and ground or negative lead and ground) | 1000 V CAT II / 600 V CAT III |
| Attenuation (switchable) | 50X/500X |
| CMRR at 60 Hz/1 MHz (typical) | 80 dB/50 dB |
| Input R (each input) | 4 MΩ |
| Input C (each input) | 7 pF |
| Power Source | AC wall adapter |
| Safety | UL3111-1/CSA1010.1/CSA1010.2.031/IEC61010-2-031/EN61010-2-031 |
| Compatible Products | All |
Important: WARNING: For safe operation, do not use the P5200 High Voltage Differential Probe with oscilloscopes that have floating inputs (isolated inputs), such as the Tektronix TPS2000 Series and THS700 Series. The P5200 requires an oscilloscope or other measurement instrument with grounded inputs.
Important: The RMS value of the waveform shall not exceed the Common Mode Voltage (RMS) for either lead.
Important: TDS7154B, TDS7254B, TDS7404B, TDS6404, TDS6604, CSA7154, and CSA7404B require a TCA-1MEG Buffer Amplifier.
Important: The P5205 and P5210 are powered through the oscilloscope's TEKPROBE interface. For use with an oscilloscope that does not have a TEKPROBE interface, the 1103 TEKPROBE Power Supply (order 1103) is required and is not included with the probe.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Tektronix
Condition
Pre-Owned
Manufacturer
Tektronix
Diff_probe_freq
25 MHz
Tektronix TCP404XL 500 A, 2 MHz AC/DC Current Probe (Requires TCPA400 Amplifier) (Pre-Owned)
TCP404XL
Tektronix TCP303 150 A, 15 MHz AC/DC Current Probe (Requires TCPA300 Amplifier) (Pre-Owned)
TCP303
Tektronix TCPA300 Current Probe Amplifier for TCP303/TCP305/TCP312 (Pre-Owned)
TCPA300
Tektronix TCPA400 Current Probe Amplifier for TCP404XL (Pre-Owned)
TCPA400
Tektronix P6015A 1000X High-Voltage Passive Probe, 75 MHz (Pre-Owned)
P6015A
Tektronix P6022 6 A, 120 MHz AC Current Probe (Pre-Owned)
P6022
ADA400A Tektronix Probe Amplifier Used
ADA400A
Tektronix TDS2024C 200 MHz 4-Channel Digital Storage Oscilloscope (Pre-Owned)
TDS2024C
Tektronix TDS2014C 100 MHz 4-Channel Digital Storage Oscilloscope (Pre-Owned)
TDS2014C
Tektronix TDS2022C 200 MHz Digital Storage Oscilloscope (Pre-Owned)
TDS2022C
P6246 Tektronix Differential Probe Used
P6246
Tektronix TDS2012C 100 MHz Digital Storage Oscilloscope (Pre-Owned)
TDS2012C
TCP202 Tektronix Current Probe Used
TCP202
Tektronix A622 100 A, 100 kHz AC/DC Current Probe with BNC (Pre-Owned)
A622
Tektronix A621 2000 A, 5 to 50 kHz AC Current Probe (Pre-Owned)
A621
Tektronix P5100A 100X High-Voltage Passive Probe, 500 MHz (Pre-Owned)
P5100A
P6205 Tektronix Active Probe Used
P6205
P5100 Tektronix Voltage Probe Used
P5100
P6138A Tektronix Voltage Probe Used
P6138A
Tektronix P2220 1X/10X Passive Probe, 200 MHz Bandwidth (Pre-Owned)
P2220
Tektronix TPP0201 10X Passive Probe, 200 MHz Bandwidth (Pre-Owned)
TPP0201
Tektronix TPP0101 10X Passive Probe, 100 MHz Bandwidth (Pre-Owned)
TPP0101
AD007 Tektronix GPIB Adapter Used
AD007
AM503S Tektronix Probe Amplifier Used
AM503S
P6703B Tektronix Accessory Used
P6703B
TDS2CM Tektronix Module Used
TDS2CM
Tektronix P6021 15 A, 60 MHz AC Current Probe (Pre-Owned)
P6021
Tektronix TCP305 50 A, 50 MHz AC/DC Current Probe (Requires TCPA300 Amplifier) (Pre-Owned)
TCP305
Tektronix TCP312 30 A, 100 MHz AC/DC Current Probe (Requires TCPA300 Amplifier) (Pre-Owned)
TCP312
Tektronix TDS2001C 50 MHz Digital Storage Oscilloscope (Pre-Owned)
TDS2001C
Tektronix TDS2002C 70 MHz Digital Storage Oscilloscope (Pre-Owned)
TDS2002C
Tektronix TDS2004C 70 MHz 4-Channel Digital Storage Oscilloscope (Pre-Owned)
TDS2004C
Request A Quote