Skip to product information
1 of 4

Keysight N9918D 26.5 GHz FieldFox Handheld Microwave Combination Analyzer

Keysight N9918D 26.5 GHz FieldFox Handheld Microwave Combination Analyzer

Regular price $43,107
Sale price $43,107 Regular price $0
Shipping calculated at checkout.
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

🎓 Request a Quote To Get An EDU Discount

Key Features At A Glance

The Keysight N9918D is a FieldFox D-Series handheld combination analyzer (CAT, VNA and spectrum analyzer) covering 30 kHz to 26.5 GHz in CAT and VNA modes and 9 kHz to 26.5 GHz as a spectrum analyzer.

  • Test port connector: 3.5 mm (m) standard
  • Battery: Field swappable battery
  • Display and keys: Bright, low-reflection display and backlit keys enable easy viewing in direct sunlight or darkness
  • Operating system: Linux operating system
View full details

What the Keysight N9918D is and what it is used for

The Keysight N9918D is a battery-powered FieldFox analyzer for cable and antenna test, vector network analysis and spectrum analysis in the field. The cable and antenna analyzer is the base function (return loss, VSWR, distance-to-fault and 1-port cable loss); Option 210 adds S11 and S21 magnitude and phase, Option 211 adds all four S-parameters and Option 233 adds the spectrum analyzer. Keysight states that any of these options can be added as a software upgrade later.

Keysight N9918D key specifications

Model overview

Keysight N9918D: Model overview (data sheet 3126-1012.EN p.4, 39, 54, 57, 100; configuration guide 3125-1447.EN p.6)
Parameter Value Conditions
Frequency range (CAT and VNA) 30 kHz to 26.5 GHz —
Frequency range (spectrum analyzer) 9 kHz to 26.5 GHz usable to 5 kHz; the spectrum analyzer is tunable to 0 Hz or DC
Tracking generator or independent source frequency range 30 kHz to 26.5 GHz —
Tracking generator tracking mode requires Option 210 CW and CW coupled modes are included with Option 233
Test port connector 3.5 mm (m) standard Type-N (f) is not available for the N9918D
Test port input impedance 50 Ω —
Maximum real-time bandwidth (Option 350 RTSA) 10 MHz (standard); 40 MHz (Option B04); 100/120 MHz (Option B10) —
Min. signal duration, 100% POI, 10 MHz 9.13 us —
Min. signal duration, 100% POI, 40 MHz 6.13 us —
Min. signal duration, 100% POI, Option B10 5.52 us —

VNA test port output power, high power (dBm)

Keysight N9918D: VNA test port output power, high power (dBm)
Frequency Port 1 (typical) Port 2 (typical)
30 kHz to 500 kHz -6 -5
> 500 kHz to 10 MHz 0 0
> 10 MHz to 1 GHz 9 8
> 1 to 5 GHz 8 7
> 5 to 10 GHz 8 7
> 10 to 18 GHz 6 5
> 18 to 26.5 GHz 4 3

Typical values. High power is the analyzer's target output power when the Power Setting is High. Bands are shown as printed; only bands that start below this model's maximum frequency are listed (the same applies to every band table on this page).

VNA system dynamic range, high power (dB)

Keysight N9918D: VNA system dynamic range, high power (dB)
Frequency S12 spec S12 typical S21 spec S21 typical
30 kHz to 1 MHz - 114 (nominal) - 113 (nominal)
> 1 to 5 MHz3 104 111 100 110
> 5 to 6.34 MHz 105 114 100 110
> 6.34 MHz to 10 GHz 103 112 106 115
> 10 to 16 GHz 104 112 107 115
> 16 to 18 GHz 107 117 102 110
> 18 to 24 GHz 102 110 101 111
> 24 to 26.5 GHz 99 108 99 111

High power, 300 Hz IFBW, 100-point average, Port 1 or Port 2, -10 to 55 °C; S12 and S21 spec and typical columns as printed. Measured in the factory with loads on the test ports after a thru normalization. For CAT mode insertion loss (2-port), decrease the listed values by 20 dB, as CAT mode IFBW is fixed at 10 kHz. Note 3 (the band marked 3): exception for S12 spec and typical at 5 MHz, where the nominal is 90 dB.

VNA trace noise (high power, 300 Hz IFBW)

Keysight N9918D: VNA trace noise (high power, 300 Hz IFBW)
Frequency Magnitude (dB rms) Phase (deg rms)
30 kHz to 1 MHz 0.0008 (nominal) 0.008 (nominal)
> 1 MHz to 5 GHz 0.0014 0.005
> 5 to 15 GHz 0.0016 0.016
> 15 to 26.5 GHz 0.0026 0.035

Specifications (-10 to 55 °C), Port 1 or Port 2. For CAT mode, increase trace noise by a factor of 5.7, as CAT mode IFBW is fixed at 10 kHz.

VNA and CAT settings

Keysight N9918D: VNA and CAT settings (data sheet 3126-1012.EN p.4, 5, 6, 12, 14)
Parameter Value Conditions
VNA transmission/reflection (T/R) S11, S21 magnitude and phase (requires Option 210) —
VNA S-parameters S11, S21, S22, S12 magnitude and phase (requires Options 210 and 211) —
Calibrations FieldFox does not offer the traditional SOLT calibration. Instead, it offers the more accurate Full 2-port (unknown thru), and also QSOLT all Keysight USB ECal modules are supported (p.15)
Data points 101, 201, 401, 601, 801, 1001, 1601, 4001, 10,001 arbitrary number of points settable through front panel and SCPI
IF bandwidth (VNA mode) 3 Hz, 10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz note 1
System impedance 50 Ω (nominal), 75 Ω with appropriate adapter and calibration kit —
Test port output power, low power (Port 1 or Port 2) -50 dBm (flattened) model-group range 30 kHz to 26.5 GHz, ±0.5 dB
Frequency reference accuracy (-10 to 55 °C) ±0.9 ppm (spec) + aging; ±0.5 ppm (typical) + aging —
Frequency reference accuracy, locked to GPS ±0.010 ppm (nominal) GPS receiver Option 307

Note 1: VNA mode only. Recommend using averaging in CAT mode.

Spectrum analyzer DANL (dBm)

Keysight N9918D: Spectrum analyzer DANL (dBm)
Frequency Preamp off, spec (23 ±5 °C) Preamp off, typical (23 ±5 °C) Preamp off, typical (-10 to 55 °C) Preamp on, spec (23 ±5 °C) Preamp on, typical (23 ±5 °C) Preamp on, typical (-10 to 55 °C)
9 kHz to 2 MHz -118 -136 -133 -125 -150 -146
> 2 MHz to 2.1 GHz -139 -148 -146 -156 -164 -162
> 2.1 to 2.6 GHz -140 -146 -143 -155 -160 -159
> 2.6 to 4.5 GHz -142 -148 -145 -156 -163 -160
> 4.5 to 7.5 GHz -138 -146 -143 -153 -160 -158
> 7.5 to 13 GHz -139 -145 -142 -157 -162 -160
> 13 to 18 GHz -135 -142 -139 -153 -159 -158
> 18 to 22 GHz -134 -140 -137 -153 -158 -157
> 22 to 25 GHz -130 -138 -135 -150 -157 -155
> 25 to 26.5 GHz -128 -134 -131 -147 -154 -152

Input terminated, RMS detection, log averaging, 0 dB input attenuation, reference level of -20 dBm, normalized to 1 Hz RBW, measured at non-zero frequency span. The preamplifier is Option 235.

Spectrum analyzer TOI (dBm)

Keysight N9918D: Spectrum analyzer TOI (dBm)
Frequency Typical (23 ±5 °C) Typical (-10 to 55 °C)
50 MHz to 500 MHz +9 +6.5
≥ 500 MHz to 2 GHz +11 +5
≥ 2 to 2.4 GHz +14 +5
≥ 2.4 to 2.5 GHz +14 +9.5
≥ 2.5 to 7.5 GHz +11 +9.5
≥ 7.5 to 10 GHz +11 +7.5
≥ 10 to 20 GHz +13 +10
≥ 20 to 26.5 GHz +17 +15.5

Two -15 dBm signals, 100 kHz spacing: at the mixer input (N991x and N993x models, and the N995xD and N996xD), or with a reference level of -10 dBm (N995xB and N996xB, nominal). For the N995x and N996x models, bands above 23 GHz are tested with 2 MHz tone spacing.

Spectrum analyzer amplitude accuracy, preamp off (dB), to 26.5 GHz

Keysight N9918D: Spectrum analyzer amplitude accuracy, preamp off (dB), to 26.5 GHz
Frequency Spec (23 ±5 °C) Typical (23 ±5 °C) Typical (-10 to 55 °C)
9 to 100 kHz ±1.70 ±0.25 ±0.75
> 0.1 to 50 MHz ±0.70 ±0.10 ±0.20
> 50 to 500 MHz ±0.70 ±0.15 ±0.30
> 0.5 to 16.3 GHz ±0.90 ±0.25 ±0.45
> 16.3 to 18 GHz ±0.80 ±0.20 ±0.35
> 18 to 26.5 GHz2 ±0.90 ±0.25 ±0.50

10 dB attenuation, input signal -15 to -5 dBm, peak detector, 300 Hz RBW, all settings auto-coupled, includes frequency response uncertainties; no warm-up required. Note 2 (the 18 to 26.5 GHz band marked 2): N9938B and N9938D units with Type-N connectors are tested using a system calibrated in 3.5 mm with a precision 3.5 mm to Type-N adapter; the effect of its modes between 18 GHz and 26.5 GHz is included.

Spectrum analyzer SSB phase noise at 1 GHz (dBc/Hz)

Keysight N9918D: Spectrum analyzer SSB phase noise at 1 GHz (dBc/Hz) (data sheet 3126-1012.EN p.51)
Parameter Value
Offset 10 kHz, spec (23 ±5 °C) -107
Offset 10 kHz, typical (23 ±5 °C) -112
Offset 10 kHz, typical (-10 to 55 °C) -111
Offset 30 kHz, spec (23 ±5 °C) -110
Offset 30 kHz, typical (23 ±5 °C) -113
Offset 30 kHz, typical (-10 to 55 °C) -113
Offset 100 kHz, spec (23 ±5 °C) -106
Offset 100 kHz, typical (23 ±5 °C) -110
Offset 100 kHz, typical (-10 to 55 °C) -110
Offset 1 MHz, spec (23 ±5 °C) -121
Offset 1 MHz, typical (23 ±5 °C) -125
Offset 1 MHz, typical (-10 to 55 °C) -124
Offset 3 MHz, spec (23 ±5 °C) -126
Offset 3 MHz, typical (23 ±5 °C) -130
Offset 3 MHz, typical (-10 to 55 °C) -128
Offset 5 MHz, spec (23 ±5 °C) -124
Offset 5 MHz, typical (23 ±5 °C) -129
Offset 5 MHz, typical (-10 to 55 °C) -128

The 3 MHz offset is tested at 2.99 MHz (and in the D-Series data sheet the 5 MHz offset at 4.99 MHz).

Spectrum analyzer settings and ranges

Keysight N9918D: Spectrum analyzer settings and ranges (data sheet 3126-1012.EN p.40, 41, 42, 46, 48, 59; technical document 5992-3703EN p.22)
Parameter Value Conditions
Resolution bandwidth (-3 dB), non-zero span 1 Hz to 5 MHz —
Resolution bandwidth (-3 dB), zero span 10 Hz to 5 MHz —
Video bandwidth (VBW) 1 Hz to 5 MHz —
Measurement range DANL to +20 dBm —
Input attenuator range 0 to 40 dB, in 5 dB steps —
Preamplifier gain (Option 235) +15 dB, 9 kHz to 7.5 GHz; +20 dB, ≥ 7.5 to 26.5 GHz group row; full band (9 kHz to maximum frequency of instrument)
Spur free dynamic range, 2.4 GHz (dB) > 106 —
Sweep (trace) points 101, 201, 401, 601, 801, 1001 (defaults to 401) arbitrary 2 to 20,001 settable through soft key or SCPI
Sweep time, zero span (range) 1 μs to 6000 s —
50 MHz absolute amplitude accuracy (dB) ±0.50; ±0.10; ±0.20 spec (23 ±5 °C); typical (23 ±5 °C); typical (-10 to 55 °C); 10 dB attenuation, input signal -40 to -5 dBm, peak detector, preamplifier off, 300 Hz RBW
Input related responses (dBc), -30 dBm signal at mixer input -80 excludes the frequencies listed in the data sheet table, p.46
I/Q streaming (requires option 353) Maximum BW of 120 MHz with Option B10 over the SFP+ or Ethernet port in either VITA 49A or Decodio formats
I/Q streaming (Option 353), data gapless IQ data to external application software —

VNA corrected directivity (dB)

Conditions: 85520A or 85521A, full 2-port Cal, DUT: 3.5 mm

Keysight N9918D: VNA corrected directivity (dB) (data sheet 3126-1012.EN p.19)
Parameter Value
Directivity, 0.3 to 500 MHz 40
Directivity, 0.5 to 5 GHz 39
Directivity, 5 to 15 GHz 33
Directivity, 15 to 26.5 GHz 29

Corrected performance (coverage factor of 2) with the calibration kit named above; other kits and terms are in the data sheet.

Compare the Keysight N9918D with other models

Keysight N9918D: compare FieldFox microwave (combination) analyzers (data sheet 3126-1012.EN p.4, 100)
Model Frequency range (CAT and VNA) Test port connector
N9916D 30 kHz to 14 GHz Type-N (f)
N9917D 30 kHz to 18 GHz Type-N (f)
N9918D (this page) 30 kHz to 26.5 GHz 3.5 mm (m) standard
N9950D 300 kHz to 32 GHz NMD 2.4 mm (m)
N9951D 300 kHz to 44 GHz NMD 2.4 mm (m)
N9952D 300 kHz to 50 GHz NMD 2.4 mm (m)
N9953D 300 kHz to 54 GHz NMD 1.85 mm (m)

What decides whether the Keysight N9918D fits

Test ports: which connector does the Keysight N9918D use?

The Keysight N9918D test port connector is 3.5 mm (m) standard, with an input impedance of 50 Ω. Calibration kits, cables and adapters must match that connector and the frequency range; the configuration guide lists Keysight mechanical calibration kits and USB ECal modules by connector type.

Licensed features: what is installed on the Keysight N9918D?

On the Keysight N9918D the measurement capabilities are license-key options, so confirm the options installed on a particular unit before relying on them.

Rules of thumb (not specifications)

Protecting an RF input. The level reaching an input, after any attenuator, must stay below that input's stated maximum safe level; the attenuator's own power rating must exceed the power applied to it. Rule of thumb, not a specification.

Example with the Keysight N9918D: The Keysight N9918D test ports accept at most +27 dBm, 0.5 watts average CW power. A source that could exceed it needs an external attenuator in front of the port, and that attenuator's own power rating must exceed the power applied to it.

Noise floor and resolution bandwidth. Displayed noise changes by 10·log10 of the resolution-bandwidth ratio: 10× narrower lowers it by 10 dB. A noise floor normalized to 1 Hz must be scaled to the bandwidth in use before comparing with a signal level. Rule of thumb, not a specification.

Example with the Keysight N9918D: The Keysight N9918D noise floor of -139 dBm in the > 2 MHz to 2.1 GHz band is normalized to 1 Hz; measured with a 10× wider RBW, the displayed noise is about 10 dB higher by this rule.

Keysight N9918D options and what they change

The measurement options and accessories that the configuration guide lists for the Keysight N9918D are on the Options tab.

Keysight N9918D safety and limits

Keysight N9918D: Safety and limits (data sheet 3126-1012.EN p.10, 41)
Parameter Value Conditions
Maximum input level, test ports (average CW power) +27 dBm, 0.5 watts Port 1 or Port 2
Maximum input level, test ports (DC) ±50 VDC Port 1 or Port 2
Spectrum analyzer maximum safe input level (average CW power) +27 dBm, 0.5 watts —
Spectrum analyzer maximum safe input level (DC) ±50 VDC —

Other Keysight N9918D specifications

General, power and interfaces

Keysight N9918D: General, power and interfaces (data sheet 3126-1012.EN p.94, 98, 99, 100, 101)
Parameter Value Conditions
Dimensions (H x W x D) 292 x 188 x 82 mm (11.5 x 7.4 x 3.2 in) (approx.) —
Ingress protection IP53 type tested; IP rating for the instrument by itself, with no cover
Operating temperature, AC power -10 to 55 °C (14 to 131 °F) -10 to 45 °C/14 to 113 °F in RTSA mode
Operating temperature, battery -10 to 50 °C (14 to 122 °F) —
Storage temperature -51 to 71 °C (-60 to 160 °F) —
External DC input 15 VDC, 4 amps maximum —
External AC power adapter input 100 to 240 VAC, 50 to 60 Hz, 1.5 to 0.75 A —
Power consumption 16 to 30 watts (typical), 60 watts maximum —
Battery (lithium ion) 10.95 V, 7.0 A-h, 77 Wh —
Battery charge time about 1.5 hours to recharge to 80%. Four hours to 100% —
Display 6.5” transflective color LCD-LED backlit; touchscreen for file management —
SFP+, 2 ports Compact, hot-pluggable sockets compatible with 10-GbE (Gigabit Ethernet) —
USB-A, 1 port High-speed USB 3.0, for data transfer and SCPI programming —
USB-C, 1 port High-speed USB 3.0/DP out, for data transfer, SCPI programming, and USB earphone plug-in —
LAN (RJ-45) 1000/100/10 base-T (auto switching) used for programming, data saving, remote control, and DataLink software
Internal data storage Internal Minimum: 4 GB —
External data storage Supports USB 3.0 compatible memory devices and SD/SDHC memory cards —
Built-in GNSS (GPS+) receiver (Option 307), supported systems GPS, GLONASS, BeiDou and Galileo requires external GNSS/GPS antenna (can use N9910X-825, GPS active antenna)
DC bias variable-voltage source (Option 309), voltage +2.5 to +32 V (nominal) SMB (m) connector
DC bias variable-voltage source (Option 309), maximum current 2 A (nominal) above 3.5 V the current is limited by the 7 W maximum power
DC bias variable-voltage source (Option 309), maximum power 7 watts (nominal) —

Further data sheet tables

Keysight N9918D: Further data sheet tables
Specification Where in the data sheet
Corrected measurement uncertainty, other terms and calibration kits Data sheet p.17, Corrected Measurement Uncertainty
Max leveled output power Data sheet p.6, Max leveled output power (dBm)
Receiver compression Data sheet p.10, Receiver compression
Total absolute amplitude accuracy with preamp on Data sheet p.43, Total absolute amplitude accuracy (dB) with preamp on
Tracking generator output power (high) Data sheet p.55, Output power (high) (dBm)
I/Q analyzer (Option 351) Data sheet p.58, I/Q Analyzer (IQA) (Option 351)

Keysight N9918D questions and answers

What else is needed to use the Keysight N9918D?

For accurate network and cable measurements the Keysight N9918D needs a calibration kit or USB ECal module for its test port connector (the factory CalReady correction suits quick pass/fail checks), and test cables rated for the frequency range. The GPS receiver (Option 307) needs a GPS antenna such as the N9910X-825, and USB power sensor measurements (Option 302) need a Keysight USB power sensor.

How is a vector network analyzer different from a spectrum analyzer?

The Keysight N9918D does both. In VNA mode it sends its own test signal into a component and measures what is reflected and transmitted (S-parameters); as a spectrum analyzer it measures signals that already exist.

Specifications are from the manufacturer's data sheet (FieldFox D-Series Handheld Analyzers 14/18/26.5/32/44/50/54 GHz Data Sheet, 3126-1012.EN, June 24, 2026) and configuration guide (FieldFox Handheld Analyzers 14/18/26.5/32/44/50/54 GHz (D Series) Configuration Guide, 3125-1447.EN, April 6, 2026) and technical document (FieldFox Handheld Analyzers 4/6.5/9,10/14/18/26.5/32/44/50/54 GHz Technical Overview, 5992-3703EN, December 4, 2025). Questions? Contact your Test Architect.

Updated 2026-11-26

Model No

Keysight

Condition

Factory New

Manufacturer

Keysight

Net_ana_freq

26.5 GHz

Please note

This list holds at most 128 lines, so long tables are shown as one line each, exactly as printed. The manufacturer's documents are the source of truth; our records hold 184 orderable items for this model from them.

010

VNA time domain. Requires 210, recommend 211.

210

VNA transmission/reflection. Recommend ordering a calibration kit.

211

VNA full 2-port S-parameters. Requires 210, recommend ordering a calibration kit.

212

1-port mixed-mode S-parameters. Requires 210 and 211.

215

TDR cable measurements.

308

Vector voltmeter. 210 and 211 required for full VVM functionality.

209

Extended Range Transmission Analysis (ERTA). Requires 233 and 210 for Combo analyzers (N991x/5x), or 220 for Signal analyzers (N993x/6x). Recommend 307. Requires two FieldFox units.

233

Spectrum analyzer.

235

Pre-amplifier. Requires 233.

236

Interference analyzer and spectrogram. Requires 233.

238

Spectrum analyzer time gating. Requires 233.

312

Channel scanner. Requires 233. Require the corresponding option to support a specific app. For example, to support EMF in channel scanner requires 358; to support indoor and outdoor mapping requires 352.

350

Real-Time Spectrum Analyzer (RTSA). Requires 233, Recommend 235.

351

I/Q Analyzer (IQA). Requires 233.

352

Indoor and outdoor mapping. Requires 233, 307, and at least one of 312, 370, 371, or 378.

353

IQ streaming. Requires 233, 351. Data streaming bandwidth up to 120 MHz with B10.

355

Analog demodulation. Requires 233.

356

Noise Figure (NF). Requires 233, 235, 309 and accessory item N9910X-713 BNC to SMB cable.

357

Pulse generator. Requires 233.

358

EMF measurements. Requires 233. Also requires triaxial antenna.

361

EMI measurements. Requires 233.

366

Interference finder (manual mode). Requires 233, 307, and 85574A Handheld direction antenna.

370

Over-the-Air (OTA) LTE FDD. Requires 233 and 307. Recommend 235.

371

Over-the-Air (OTA) LTE TDD. Requires 233 and 307. Recommend 235.

378

Over-the-Air (OTA) 5G NR. Requires B10 and 307. Recommend 235.

390

Directional finding - TDOA node support. Requires 233.

391

Directional Finding - Angle of Arrival (AoA). Requires 233, and 85573A AoA antenna.

B04

Analysis bandwidth, 40 MHz. Requires 233. Recommend 350, 351 or PathWave VSA (formerly 89600 VSA) software.

B10

Analysis bandwidth, 120 MHz. Requires 233. Recommend 350, 351, 378 or PathWave VSA (formerly 89600 VSA) software.

208

USB power sensor meas. versus frequency. Requires 302.

302

USB power sensor support. Need to order USB power sensor.

310

Built-in power meter. No power sensor required.

330

Pulse meas. with USB peak power sensor. Requires 302 and USB peak power sensor.

030

Remote control capability. Requires an iOS or an Android device.

307

GPS receiver. Need to order GPS antenna, N9910X-825.

309

DC Power Supply (DCPS). Recommend N9910X-713 cable.

89601C

PathWave VSA (89600 VSA) software. Requires 233.

N6820ES

Surveyor 4D software. Requires 233, 235 and 307.

SJ002A

WaveJudge Wireless Analyzer Toolset. Requires 233.

S9910A

Keysight spectrum management software (KSMS). Requires 233, 235 and 307.

S9911A

Directional Finding - TDOA. Requires S9910A.

S9912A

Directional Finding - AoA. Requires S9910A.

N9910X-874

External bias-tee, 2.5 MHz to 6 GHz, 1 W, 0.5 A. Also recommend ordering N9910X-713 Bias-Tee Power Cable, SMB(f) to BNC(m), 3.28 ft., to connect to the FieldFox DC source.

Other FieldFox Accessories

N9910X-876 Extra high-capacity battery; N9910X-880 Extra soft carrying case with backpack and shoulder strap; N9910X-872 External battery charger; N9910X-873 AC/DC adapter; N9910X-881 Hard transit case; N9910X-875 DC car charger and adapter.

Antennas

N9910X-825 Antenna, GPS, active, SMA (m); N9910X-820 Antenna, directional, multiband, 800 to 2500 MHz, 10 dBi, Type-N (f); N9910X-821 Antenna, telescopic whip, 70 MHz to 1 GHz, BNC (m); N9910X-822 Antenna, directional, log periodic, 600 MHz to 9 GHz, Type-N (f); N9910XA-823 Antenna, cellular narrowband, 824 to 869 MHz, Type-N (f); N9910XA-824 Antenna, cellular narrowband, PCS 1850 to 1990 MHz, Type-N (f); 85572A EMF Triaxial antenna; 85572A-006 Triaxial Isotropic Antenna 400 MHz to 6 GHz; 85572A-007 Triaxial Isotropic Antenna 30 MHz to 6 GHz; 85573A Automatic DF Antenna and accessories; 85573A-108 20 MHz to 8 GHz DF AoA antenna (including cable assembly); 85574A Handheld direction antenna and accessories; 85574A-100 20 MHz to 8.5GHz direction antenna with digital compass; 85574A-209 Frequency extension for 85574A option 100 - 9 kHz to 20 MHz.

Other RF and Microwave Accessories

N9910X-712 Trig/Ref in Cable SMA (m) to BNC (f), 1 m or 3.28 ft; N9910X-713 Bias-tee power cable SMB (f) to BNC (m), 1 m or 3.28 ft; N9910X-886 Torque wrench, 17 mm, 90 N-cm (8 in-lb), used for connecting with 3.5 mm, 2.4 mm, or 1.85 mm connectors; N9910X-860 Fixed attenuator, 40 dB, 100 W, DC to 3 GHz, Type-N (m) to Type-N (f); N9910X-861 Fixed attenuator, 40 dB, 50 W, DC to 8.5 GHz, Type-N (m) to Type-N (f); N9910X-895 Magnetic mount base for antenna.

Cables

N9910X-708 3.5 mm (m) 3.5 mm (f) 26.5 GHz 3.28 ft 1 m; N9910X-709 3.5 mm (f) 3.5 mm (f) 26.5 GHz 3.28 ft 1 m.

83059A

Coaxial adapter, 3.5 mm (m) to 3.5 mm (m), 26.5 GHz.

83059B

Coaxial adapter, 3.5 mm (f) to 3.5 mm (f), 26.5 GHz.

83059C

Coaxial adapter, 3.5 mm (m) to 3.5 mm (f), 26.5 GHz.

RF and Microwave Adapters

N9910X-604 3.5 mm NMD (f) to 3.5 mm (f) adapter, 26.5 GHz; N9910X-605 3.5 mm NMD (f) to Type-N (f) adapter, 18 GHz; N9910X-848 Coaxial adapter, Type-N (f) to 3.5 mm (f), 18 GHz; N9910X-849 Coaxial adapter, Type-N (f) to 3.5 mm (m), 18 GHz.

85518A

4-in-1 OSLT cal kit Type-N (m) DC to 18 GHz Open, short, load, thru (all male).

85519A

4-in-1 OSLT cal kit Type-N (f) DC to 18 GHz Open, short, load, thru (all female).

85054D

Economy cal kit Type-N DC to 18 GHz Open, short, load, thru (both female and male).

N4690D

ECal, 2-ports Type-N 300 kHz to 18 GHz or DC to 18 GHz Connectors configurable.

N7554A

ECal economy, 2-ports Type-N DC to 18 GHz Connectors configurable.

85520A

4-in-1 OSLT 3.5 mm (m) DC to 26.5 GHz Open, short, load, thru (all male).

85521A

4-in-1 OSLT 3.5 mm (f) DC to 26.5 GHz Open, short, load, thru (all female).

85052D

Economy cal kit 3.5 mm DC to 26.5 GHz Open, short, fixed load (both female and male).

85052B

Standard cal kit 3.5 mm DC to 26.5 GHz Open, short, fixed load, sliding load (both female and male).

85052C

Precision TRL kit 3.5 mm DC to 26.5 GHz Open, short, fixed load (both female and male), two-line lengths.

N4691D

ECal, 2-ports 3.5 mm 300 kHz to 26.5 GHz or DC to 26.5 GHz Connectors configurable.

N7550A

ECal economy, 2-ports 3.5 mm DC to 4 GHz Connectors configurable.

N7551A

ECal economy, 2-ports 3.5 mm DC to 6.5 GHz Connectors configurable.

N7552A

ECal economy, 2-ports 3.5 mm DC to 9 GHz Connectors configurable.

N7553A

ECal economy, 2-ports 3.5 mm DC to 14 GHz Connectors configurable.

N7555A

ECal economy, 2-ports 3.5 mm DC to 26.5 GHz Connectors configurable.

X11644A

Waveguide cal kit WR-90 8.2 to 12.4 GHz Short, shim, termination, standard section.

K11644A

Waveguide cal kit WR-42 18 to 26.5 GHz Short, shim, termination, standard section.

Calibration kits, Waveguide

N9911X-11x Econ. waveguide cal kit WR-137 5.38 to 8.18 GHz Short, termination, offset length; N9911X-21x Econ. waveguide cal kit WR-90 8.2 to 12.5 GHz Short, termination, offset length; N9911X-31x Econ. waveguide cal kit WR-62 11.9 to 18 GHz Short, termination, offset length; N9911X-41x Econ. waveguide cal kit WR-42 17.6 to 26.7 GHz Short, termination, offset length; P11644A Waveguide cal kit WR-62 12.4 to 18 GHz Short, shim, termination, standard section.

Calibration kits, 3.5 mm

85033D/E Economy cal kit 3.5 mm DC to 6/9 GHz Open, short, fixed load (both female and male); 85093C ECal, 2-ports 3.5 mm 300 kHz to 9 GHz Connectors configurable.

U2000A

USB Average 10 MHz to 18 GHz, -60 dBm to +20 dBm.

U2000B

USB Average 10 MHz to 18 GHz, -30 dBm to +44 dBm.

U2000H

USB Average 10 MHz to 18 GHz, -50 dBm to +30 dBm.

U2001A

USB Average 10 MHz to 6 GHz, -60 dBm to +25 dBm.

U2001B

USB Average 10 MHz to 6 GHz, -30 dBm to +44 dBm.

U2001H

USB Average 10 MHz to 6 GHz, -50 dBm to +30 dBm.

U2002A

USB Average 50 MHz to 24 GHz, -60 dBm to +20 dBm.

U2002H

USB Average 50 MHz to 24 GHz, -50 dBm to +30 dBm.

U2004A

USB Average 9 kHz to 6 GHz, -60 dBm to +20 dBm.

U2021XA

USB Average and peak 50 MHz to 18 GHz, -30 dBm to +20 dBm.

U2022XA

USB Average and peak 50 MHz to 40 GHz, -30 dBm to +20 dBm.

U2051XA

USB Average 10 MHz to 6 GHz, -70 dBm to +26 dBm.

U2052XA

USB Average 10 MHz to 18 GHz, -70 dBm to +26 dBm.

U2053XA

USB Average 10 MHz to 33 GHz, -70 dBm to +26 dBm.

U2054XA

USB Average 10 MHz to 40 GHz, -70 dBm to +20 dBm.

U2055XA

USB Average 10 MHz to 50/53 GHz, -70 dBm to +20 dBm.

U2056XA

USB Average 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

U2057XA

USB Average 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

U2062XA

USB Average and peak 10 MHz to 18 GHz, -70 dBm to +26 dBm.

U2063XA

USB Average and peak 10 MHz to 33 GHz, -70 dBm to +26 dBm.

U2064XA

USB Average and peak 10 MHz to 40 GHz, -70 dBm to +20 dBm.

U2065XA

USB Average and peak 10 MHz to 50/53 GHz, -70 dBm to +20 dBm.

U2066XA

USB Average and peak 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

U2067XA

USB Average and peak 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

U8481A

USB Average 10 MHz to 18 GHz, -35 dBm to +20 dBm.

U8485A

USB Average 10 MHz to 33 GHz, -35 dBm to +20 dBm.

U8487A

USB Average 10 MHz to 50 GHz, -35 dBm to +20 dBm.

U8488A

USB Average 10 MHz to 67 GHz, -35 dBm to +20 dBm.

U8489A

USB Average DC to 120 GHz, -35 dBm to +20 dBm.

L2051XA

LAN Average 10 MHz to 6 GHz, -70dBm to +26 dBm.

L2052XA

LAN Average 10 MHz to 18 GHz, -70dBm to +26 dBm.

L2053XA

LAN Average 10 MHz to 33 GHz, -70dBm to +26 dBm.

L2054XA

LAN Average 10 MHz to 40 GHz, -70dBm to +20 dBm.

L2055XA

LAN Average 10 MHz to 50/53 GHz, -70dBm to +20 dBm.

L2056XA

LAN Average 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

L2057XA

LAN Average 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

L2061XA

LAN Average and peak 10 MHz to 6 GHz, -70dBm to +26 dBm.

L2062XA

LAN Average and peak 10 MHz to 18 GHz, -70dBm to +26 dBm.

L2063XA

LAN Average and peak 10 MHz to 33 GHz, -70dBm to +26 dBm.

L2064XA

LAN Average and peak 10 MHz to 40 GHz, -70dBm to +20 dBm.

L2065XA

LAN Average and peak 10 MHz to 50/53 GHz, -70dBm to +20 dBm.

L2066XA

LAN Average and peak 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

L2067XA

LAN Average and peak 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

L2066XT

LAN Thermal Vacuum Compliance 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

L2067XT

LAN Thermal Vacuum Compliance 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

U2049XA

LAN Average and peak 10 MHz to 33 GHz, -70dBm to +20 dBm.

Power sensors

U2041XA USB Average 10 MHz to 6 GHz, -70 dBm to +26 dBm; U2042XA USB Average and peak 10 MHz to 6 GHz, -70 dBm to +26 dBm; U2043XA USB Average 10 MHz to 18 GHz, -70 dBm to +26 dBm; U2044XA USB Average and peak 10 MHz to 18 GHz, -70 dBm to +26 dBm; L2065XT LAN Average and peak 10 MHz to 53 GHz, -70dBm to +20 dBm.

U7227A

USB preamplifier, 10 MHz to 4 GHz.

U7227C

USB preamplifier, 100 MHz to 26.5 GHz.

U7227F

USB preamplifier, 2 to 50 GHz.

Preamplifiers

U7228A USB preamplifier, 10 MHz to 4 GHz; U7228C USB preamplifier, 100 MHz to 26.5 GHz; U7228F USB preamplifier, 2 to 50 GHz.

Noise Sources

346A/B/C/CK01/CK40 Noise source family; U1832A USB smart noise source, 10 MHz to 18 GHz, 5 dB ENR nominal; U1832B USB smart noise source, 10 MHz to 26.5 GHz, 5 dB ENR nominal; U1832C USB smart noise source, 500 MHz to 50 GHz, 5 dB ENR nominal; U1833A USB smart noise source, 10 MHz to 18 GHz, 15 dB ENR nominal; U1833B USB smart noise source, 10 MHz to 26.5 GHz, 15 dB ENR nominal; U1833C USB smart noise source, 500 MHz to 50 GHz, 15 dB ENR nominal; U1833D USB smart noise source, 500 MHz to 60 GHz, 10 dB ENR nominal.

Keysight N9910XVDI (or VDI PSAX) Frequency Extender Modules

N9910XVDI VDI frequency extenders for FieldFox; N9910XVDI-W15 WR15 frequency extender, 50 to 75 GHz; N9910XVDI-W12 WR12 frequency extender, 60 to 90 GHz.

VDI Frequency Extender Module Adapter Kits

N9910XVDI-101 Male-SMA to female-SMA male, Qty 2 of 1250-3851; N9910XVDI-104 Female-SMA to male-SMA adapter, right angle, for connecting GPS antenna or Trigg/Ref input; N9910XVDI-100 DC power cable replacement.

Recommended Services

R-55B-001-1 KeysightCare Enhanced - Upgrade 1 year; R-55B-001-2 KeysightCare Enhanced - Extend to 2 years; R-55B-001-3 KeysightCare Enhanced - Extend to 3 years (Recommended); R-55B-001-5 KeysightCare Enhanced - Extend to 5 years (Recommended); R-55A-001-2 KeysightCare Assured - Extend to 2 years; R-55A-001-3 KeysightCare Assured - Extend to 3 years; R-55A-001-5 KeysightCare Assured - Extend to 5 years; PS-S40-01 Included - instrument fundamentals and operations starter; PS-S40-04 Recommended - instrument fundamentals and operations starter; PS-S40-02 Optional, technology & measurement science standard learning.