Skip to content

The Keysight N9918B FieldFox is a ruggedized handheld combination analyzer covering 30 kHz to 26.5 GHz. As part of the FieldFox B-series, the N9918B integrates cable and antenna tester (CAT), vector network analyzer (VNA), and spectrum analyzer (SA) functionality in a single field-portable instrument, designed to bring laboratory-grade microwave measurement capability to environments where benchtop instruments cannot be deployed.
The datasheet describes the FieldFox as equipment built to be carried into the field, with type-tested compliance to MIL-PRF-28800F Class 2 covering operating temperature, storage temperature, operating humidity, random vibration, functional shock, and bench drop. The IP53 ingress protection rating per IEC/EN 60529 supports outdoor use in dust and light precipitation, and the instrument is type-tested for operation in explosive environments per MIL-STD-810G, Method 511.5, Procedure I. Typical applications supported by the datasheet's measurement coverage include cellular tower commissioning, antenna and cable verification, RF component characterization, and field spectrum monitoring.
ValueTronics International stocks, tests, and supports Keysight FieldFox analyzers including the N9918B from our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Every {{CONDITION}} N9918B leaving our facility has been inventoried, inspected, and prepared for shipment by our in-house team — not drop-shipped from a third party. Customers ordering through ValueTronics work with technical specialists who have direct knowledge of the FieldFox product family and the test applications it supports, with calibration documentation and ISO-traceable services available on request.
Keysight Technologies' test and measurement business traces its origin to Hewlett-Packard, which spun out its test and measurement, semiconductor products, and chemical analysis businesses as Agilent Technologies in 1999. In 2014, Agilent further divided its operations, with the electronic measurement business becoming Keysight Technologies. Engineers may encounter FieldFox documentation, accessories, and service materials referencing both Agilent and Keysight branding depending on the production date.
The FieldFox B-series spans two analyzer architectures across the 4 GHz to 50 GHz range. The N991xB combination analyzers (N9913B through N9918B) integrate CAT, VNA, and SA capability with 30 kHz lower frequency limits, while the N993xB signal analyzers (N9933B through N9938B) share the same upper frequency tiers but are positioned as spectrum-focused instruments. The N995xB and N996xB microwave series extends combination and signal analyzer coverage to 32, 44, and 50 GHz with a 300 kHz lower frequency limit.
Per the datasheet, all FieldFox models share a common physical platform — 292 x 188 x 82 mm, 3.34 kg with battery, 6.5" transflective color LCD-LED display, lithium-ion battery operation, LAN/USB connectivity, and MIL-PRF-28800F Class 2 environmental compliance. Models differ primarily in upper frequency limit, included measurement modes (combination vs. signal analyzer), and available connector type at the test ports.
Each new FieldFox model listed below is its own dedicated product page on ValueTronics with condition-matched pricing and availability. Use the comparison table to identify the model that fits your frequency range and measurement requirements, then navigate to the individual listing for ordering details specific to that unit.
The N9918B is the upper-frequency boundary of the N991xB combination analyzer line at 26.5 GHz. Per the datasheet, the 26.5 GHz models use 3.5 mm (m) test port connectors rather than the Type-N (f) connectors used on lower-frequency members of the series; Type-N is not offered on the N9918B combination analyzer. This connector choice supports the measurement performance and connector durability required at K-band frequencies.
Within the FieldFox B-series, primary differentiation across models is upper frequency limit: 4 GHz (N9913B/N9933B), 6.5 GHz (N9914B/N9934B), 9 GHz (N9915B/N9935B), 14 GHz (N9916B/N9936B), 18 GHz (N9917B/N9937B), 26.5 GHz (N9918B/N9938B), 32 GHz (N9950B/N9960B), 44 GHz (N9951B/N9961B), and 50 GHz (N9952B/N9962B). The datasheet specifies test port output power, dynamic range, DANL, phase noise, and amplitude accuracy separately for each model class.
The combination analyzers (N991xB, N995xB) include CAT and VNA capability with the spectrum analyzer offered as Option 233, while the signal analyzers (N993xB, N996xB) come configured as spectrum-focused instruments. Connector types vary by frequency tier: Type-N (f) for ≤18 GHz models, 3.5 mm (m) on the N9918B and optionally on N9938B, and 2.4 mm (m) on all 32/44/50 GHz models. Refer to the comparison table below for the differentiating specifications at each tier.
| Model | Frequency Range | Analyzer Type | Test Port Connector |
|---|---|---|---|
| N9913B | 30 kHz to 4 GHz | RF Combination (CAT+VNA+SA) | Type-N (f) |
| N9914B | 30 kHz to 6.5 GHz | RF Combination (CAT+VNA+SA) | Type-N (f) |
| N9915B | 30 kHz to 9 GHz | RF Combination (CAT+VNA+SA) | Type-N (f) |
| N9916B | 30 kHz to 14 GHz | RF Combination (CAT+VNA+SA) | Type-N (f) |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| General Information | |
| Calibration cycle | 1 year |
| Weight (including battery, approx.) | 3.34 kg / 7.35 lb |
| Dimensions (H x W x D, approx.) | 292 x 188 x 82 mm (11.5 in x 7.4 in x 3.2 in) |
| Environmental | MIL-PRF-28800F Class 2 |
| Maximum humidity (non-condensing) | 95% RH up to 40°C, decreases linearly to 45% RH at 55°C |
| Altitude - operating | 9,144 m / 30,000 ft (using battery) |
| Altitude - non-operating | 15,240 m / 50,000 ft |
| Altitude - AC to DC adapter | 3,000 m / 9,840 ft |
| Ingress protection | IP53 per IEC/EN 60529 (instrument by itself, with no cover) |
| Temperature Range | |
| Operating, AC power (spec) | -10 to 55°C (14 to 131°F); -10 to 45°C in RTSA mode |
| Operating, battery (spec) | -10 to 50°C (14 to 122°F) |
| Operating, battery (typical) | -10 to 55°C (14 to 131°F) |
| Storage (spec) | -51 to 71°C (-60 to 160°F) |
| Power Supply | |
| External DC input | 15 to 19 VDC, 4 A max when battery charging |
| AC power adapter input | 100 to 240 VAC, 50 to 60 Hz, 1.5 to 0.75 A |
| AC power adapter output | 15 VDC, 6 A |
| Power consumption (typical) | 16 to 30 watts |
| Battery | |
| Type | Lithium ion, 10.8 V, 6.4 A-h, 70 Wh |
| Operating time (typical, mode dependent) | 4 hours |
| Charge time | ~1.5 hours to 80%, 4 hours to 100% |
| Test Port Connectors | |
| Input impedance | 50 Ω |
| ≤ 18 GHz models | Type-N (f) |
| 26.5 GHz N9918B | 3.5 mm (m) |
| 26.5 GHz N9938B | 3.5 mm (m) or Type-N (f) |
| 32, 44, 50 GHz models | 2.4 mm (m) |
| Display & Interfaces | |
| Display | 6.5" transflective color LCD-LED backlit |
| Headphone jack | 3.5 mm (1/8 in) miniature audio jack |
| USB-A ports | 2 ports, Hi-speed USB 2.0 |
| Mini USB | 1 port, Hi-speed USB 2.0 (SCPI/USBTMC) |
| LAN | RJ-45, 1000/100/10 base-T (auto switching) (N991xB, N993xB) |
| Reference Out / Trigger Out | SMB (m), 50 Ω; 10 MHz output ≥ 0 dBm |
| Reference In / Trigger In | SMA (f), 50 Ω; 10 MHz, -5 to +10 dBm; Trigger 3.3 or 5 V TTL |
| Data Storage | |
| Internal (minimum) | 4 GB; minimum 1000 states and traces |
| External | USB 2.0 memory devices and SD/SDHC cards (FAT, exFAT) |
| Data types | Trace, trace+state, picture (png), data (csv), S1P, S2P |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Keysight
Condition
New
Manufacturer
Keysight
Frequency
4 GHz
10
Vector network analyzer time domain Requires 210 , recommend 211
30
Remote control capability Requires an iOS device or an Android device
208
USB power sensor measurements versus frequency Requires 302
209
Extended range transmission analysis (ERTA) Requires 233 and 210 1 , recommend 307
210
Vector network analyzer transmission/reflection
211
Vector network analyzer full 2-port S-parameters Requires 210
212
1-port mixed-mode S-parameters Requires 210 and 211
215
TDR cable measurements
233
Spectrum analyzer
235
Pre-amplifier Requires 233
236
Interference analyzer and spectrogram Requires 233
238
Spectrum analyzer time gating Requires 233
302
USB power sensor support
307
GPS receiver
308
Vector voltmeter Requires 210 and 211 for full VVM functionality
309
DC bias variable-voltage source Recommend N9910X-713 cable
310
Built-in power meter
312
Channel scanner Requires 233
330
Pulse measurements Requires 302 and USB peak power sensor
350
Real-time spectrum analyzer (RTSA) Requires 233 , recommend 235
351
I/Q analyzer Requires 233
352
Indoor and outdoor mapping Requires 233 , 307 , and at least one of 312 , 360 , 370 , 371 , 377 or 378.
353
IQ streaming Requires 233 and 351
355
Analog demodulation Requires 233
356
Noise figure measurements Requires 233 , 235 , 309 and accessory cable N9910X-713
358
EMF measurements Requires 233. Also requires triaxial isotropic antenna.
361
EMI measurements Requires 233
370
Over the air LTE FDD measurements Requires 233 and 307 , recommend 235
371
Over the air LTE TDD measurements Requires 233 and 307 , recommend 235
378
Over-the-air (OTA) 5G NR measurements Requires 233 , B10 , and 307 , recommend 235; N991x/3xB models require external mixer for FR2 frequencies above 26.5 GHz
B04
Bandwidth , 40 MHz Requires 233. Recommend 350 , 351 or PathWave VSA (formerly 89600 VSA) software
B10
Bandwidth , 100 MHz Requires 233. Recommend 350 , 351 , 378 or PathWave VSA (formerly 89600 VSA) software
Request A Quote