Keysight N1913A Single-Channel EPM Series Power Meter

Keysight N1913A Single-Channel EPM Series Power Meter

Regular price $7,105
Sale price $7,105 Regular price $0
Shipping calculated at checkout.
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Keysight N1913A Single-Channel EPM Series Power Meter

Key Features At A Glance

  • Single-channel (N1913A) or dual-channel (N1914A); expandable to four channels via optional USB sensor ports
  • Frequency coverage 9 kHz to 110 GHz and power range –70 to +44 dBm (100 pW to 25 W), sensor dependent
  • Measurement speed up to 400 readings/sec with Keysight E-Series power sensors
  • Meter absolute accuracy ±0.02 dB / ±0.5% (add sensor linearity for overall system accuracy)
  • Industry's first high-resolution color LCD readout in an average power meter
  • GPIB, USB 2.0, and 10/100BaseT LAN/LXI-C interfaces (IEEE 488.2, SCPI) for automated test systems
  • Optional 43x code compatibility to replace 436A, 437B, and 438A power meters; BenchVue BV0007B license included
Select Options
11730F Keysight Cable New
$1,438.00
11730E Keysight Cable New
$933.00
11730D Keysight Cable New
$677.00
34131A Keysight Case New
$646.00
11730C Keysight Cable New
$443.00
11730B Keysight Cable New
$340.00
11730A Keysight Cable New
$282.00
10833G Keysight GPIB Cable New
$210.00
10833F Keysight GPIB Cable New
$194.00
10833C Keysight GPIB Cable New
$162.00
10833B Keysight GPIB Cable New
$146.00
10833A Keysight GPIB Cable New
$129.00
10833D Keysight GPIB Cable New
$124.00
34161A Keysight Accessory New
$68.07
View full details

The Keysight N1913A and N1914A are EPM Series power meters built for RF average power measurements. The N1913A is a single-channel average power meter and the N1914A is a dual-channel average power meter. Both are positioned as versatile, user-friendly replacements for the discontinued E4418B/19B EPM Series, and the power range available on any given measurement depends on the connected power sensor.

These meters support the full set of measurement scenarios laid out in the compatible-sensor table: continuous-wave (CW) signals for metrology-lab and mobile-radio work, pulsed and averaged signals for radar and navigation, and modulated signals across wireless standards including GSM, EDGE, GPRS, cdma2000, cdmaONE, iDEN, 3G, HSPA and LTE mobile-phone formats, 802.11a/b/g/n WLAN, Bluetooth, RFID, ZigBee, WiMAX and WiBro. The specific signal types each sensor class supports vary, with several wireless-standard measurements available in average-only mode.

ValueTronics has specialized in new and used test-and-measurement equipment since 1992, operating from a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where we stock and hold our own inventory.

Brand Heritage

Keysight Technologies traces its instrument heritage to Hewlett-Packard, whose test-and-measurement business was spun out as Agilent Technologies in 1999 and then established as Keysight Technologies in 2014. Much of the EPM Series and its compatible sensor line carries this lineage forward.

Compare Other Models in This Series

The EPM Series spans two power-meter models that share the same measurement architecture, accuracy, color display, and remote-interface set, differing primarily in channel count. The N1913A is a single-channel average power meter and the N1914A is a dual-channel average power meter.

Both models accept the full range of compatible Keysight power sensors — 8480 Series, E4410 and E9300 E-Series, N8480 Series, U2000 and U8480A USB sensors, and U2040/50/60 X-Series — with the usable frequency and power range set by the connected sensor.

Each new model below is its own dedicated product page with condition-matched pricing. Select the model that fits your channel-count and code-compatibility requirements, and review that page's specifications and availability.

The N1913A is backward compatible with the 436A and 437B power meters via the optional 43x code-compatibility option (N1913A-200, or N6901A-1FP as a post-purchase upgrade), making it a direct programmatic replacement in existing single-channel test systems.

The core difference between the models is channels: the N1913A measures a single channel while the N1914A measures two channels simultaneously and can display any two of A, B, A/B, B/A, A-B, B-A and relative. With the optional USB ports, both can expand to four channels (C and D).

Measurement speed and code compatibility also differ. In fast mode with E-Series sensors the N1913A reaches 400 readings/second, while the N1914A reaches a typical 200 readings/second with both channels in fast mode. For legacy code compatibility, the N1913A maps to the 436A and 437B and the N1914A maps to the 438A. See the comparison table for the per-model details.

Model Channels Code Compatibility Max Measurement Speed
N1913A 1 436A / 437B 400 readings/sec
N1914A 2 438A 200 readings/sec (both channels FAST)
N1914A 2 438A 200 readings/sec (both channels FAST)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Power cord
  • Power sensor cable, 1.5 m (5 ft) (one per N1913A)
  • USB cable Type A to Mini-B, 6 ft
  • BenchVue BV0007B Power Meter/Sensor Control and Analysis app license (included)
Replaces: per the manufacturer, this model replaces E4418B, E4419B.

Product Core & Specifications

Specification Value
Performance Characteristics
Compatible power sensors Keysight 8480 Series; Keysight E9300 E-Series; Keysight E4410 E-Series; Keysight N8480 Series; Keysight E8486A, V8486A, W8486A; Keysight U2000 Series; Keysight U8480A Series; Keysight U2040/50/60 X-Series (except U2049XA & U2042/44/60 X-Series in Average mode only)
Frequency range 9 kHz to 110 GHz, sensor dependent
Power range –70 to +44 dBm (100 pW to 25 W), sensor dependent
Single sensor dynamic range 90 dB maximum (Keysight E-Series power sensors); 50 dB maximum (Keysight 8480 Series power sensors); 55 dB maximum (Keysight N8480 Series power sensors); 80 dB maximum (Keysight U2000 Series USB power sensors); 55 dB maximum (Keysight U8480A Series USB power sensors); 96 dB maximum (Keysight U2040/50/60 X-Series, except U2049XA & U2042/44/60 X-Series in Average mode only)
Display units Absolute: Watts or dBm. Relative: Percent or dB
Display resolution Selectable resolution of 1.0, 0.1, 0.01 and 0.001 dB in logarithmic mode, or 1, 2, 3 and 4 significant digits in linear mode
Default resolution dB in logarithmic mode or three digits in linear mode
Accuracy
Absolute accuracy ± 0.02 dB (Logarithmic) or ± 0.5% (Linear). Please add the corresponding power sensor linearity percentage to assess the overall system accuracy.
Relative accuracy ± 0.04 dB (Logarithmic) or ± 1.0% (Linear). Please add the corresponding power sensor linearity percentage to assess the overall system accuracy.
Zero set (digital stability of zero) 0.0000175% (meter only). Power sensor dependent (refer Table 1); applies when zeroing is performed with sensor input disconnected from the POWER REF.
Zero drift of sensors Sensor dependent; the change in the power meter indication over a long time (within one hour) at a constant temperature after a 24-hour warm-up of the power meter. Refer to Table 3.
Measurement noise Sensor dependent (refer to Tables 1 and 2).
Effects of averaging on noise Averaging over 1 to 1024 readings is available for reducing noise.
1 mW Power Reference
Power output 1.00 mW (0.0 dBm). Factory set to ± 0.4 % traceable to the National Physical Laboratories (NPL), UK
Accuracy (for two years) ± 0.4% (25 ± 10 ºC); ± 1.2% (0 to 55 ºC)
Frequency 50 MHz nominal
SWR 1.05 (typical), 1.08 (0 to 55 ºC)
Connector type Type-N (f), 50 Ω
Measurement Speed (remote interface)
N1913A — Normal 20 readings/second
N1913A — x2 40 readings/second
N1913A — Fast 400 readings/second, for Keysight E-Series power sensors only
N1914A — both channels in FAST mode Typical maximum measurement speed 200 readings/second (Fast mode for Keysight E-Series power sensors only)
FAST mode settling time (E-Series, free run trigger, –50 dBm to +17 dBm, 10 dB decreasing power step) N1913A: 10 ms; N1914A: 20 ms
Power Meter Functions
Zero Zeros the meter. (Power reference calibrator is switched off during zeroing.)
Cal Calibrates the meter using internal (power reference calibrator) or external source. Reference cal factor settable from 1% to 150%, in 0.1% increments.
Frequency Entered frequency range is used to interpolate the calibration factors table. Frequency range from 1 kHz to 999.9 GHz. Also settable in 1 kHz steps.
Cal factor Sets the calibration factor for the meter. Range: 1% to 150%, in 0.1% increments.
Relative Displays all successive measurements relative to the last displayed value
Offset Allows power measurements to be offset by –100 dB to +100 dB, settable in 0.001 dB increments, to compensate for external loss or gain
Save/recall Store up to 10 instrument states via the save/recall menu
dBm/W Selectable units of either Watts or dBm in absolute power; or percent or dB for relative measurements
Filter (averaging) Selectable from 1 to 1024. Auto-averaging provides automatic noise compensation.
Duty cycle Duty cycle values between 0.001% to 99.999%, in 0.001% increments, can be entered to display a peak power representation of measured power (peak power = measured power / duty cycle).
Sensor cal tables Selects cal factor versus frequency tables corresponding to specified sensors
Limits High and low limits can be set in the range –150.000 to +230.000 dBm, in 0.001 dBm increments
Preset default values dBm mode, rel off, power reference off, duty cycle off, offset off, frequency 50 MHz, AUTO average, free run, AUTO range (for E-Series sensors and N8480 Series)
Display Color display with selectable single and split screen formats. A quasi-analog display is available for peaking measurements. The dual channel power meter can simultaneously display any two configurations of A, B, A/B, B/A, A-B, B-A and relative. With the optional USB ports, additional dual channel (C & D) adds up to a total of 4-channel measurement display.
General Specifications
Dimensions (excludes front and rear protrusions) 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in)
Net weight N1913A: 3.6 kg (8.0 lb); N1914A: 3.7 kg (8.2 lb)
Shipping weight N1913A: 8.2 kg (18.1 lb); N1914A: 8.2 kg (18.3 lb)
Rear Panel Connectors
Recorder outputs Analog 0 to 1 volt, 1 kΩ output impedance, BNC connector. N1914A recorder outputs are dedicated to channel A and channel B.
GPIB, USB 2.0 and 10/100BaseT LAN Interfaces to allow communication with an external controller
Trigger Input (optional) TTL compatible logic levels, BNC connector: High: > 2.4 V; Low: < 0.7 V
Trigger Output (optional) TTL compatible logic levels, BNC connector: High: > 2.4 V; Low: < 0.7 V
Ground Binding post, accepts 4 mm plug or bare wire connection
USB Host (options) USB ports which connect to USB power sensors
VGA Out (options) Standard 15-pin VGA connector, allows connection of external VGA monitor
Line Power
Input voltage range 90 to 264 VAC, automatic selection
Input frequency range 47 to 63 Hz and 400 Hz at 110 Vac
Power requirement 75 VA (50 Watts)
Environmental Characteristics
Electromagnetic compatibility Complies with the essential requirements of EMC Directive (2004/108/EC): IEC61326-1:2005 / EN61326-1:2006; CISPR11:2003 / EN55011:2007 (Group 1, Class A); Canada: ICES/NMB-001:2004; Australia/New Zealand: AS/NZS CISPR 11:2004
Product safety IEC/EN 61010-1; CAN/CSA-C22.2 No.61010-1-04; ANSI/UL61010-1:2004
Low Voltage Directive 2006/95/EC
Operating temperature 0 to 55 °C
Maximum humidity 95% at 40 °C (non-condensing)
Maximum altitude 4,600 meters (15,000 feet)
Non-operating storage temperature –40 to +70 °C
Important: Fast mode (400 readings/sec) is available with Keysight E-Series power sensors only.
Important: A compatible power sensor is required to make measurements and is not included with the power meter; the measurable frequency and power range depend on the connected sensor. The N1913A/N1914A support all average power sensors, including the 8480 Series (including discontinued models), N8480 Series, E-Series (E4410/E9300), and supported U2000/U8480A/U2040-50-60 X-Series USB sensors. Order the appropriate power sensor separately.
Important: 43X code compatibility is available only with option N191xA-200 at time of purchase (N1913A is backward compatible with 436A and 437B; N1914A is compatible with 438A), or as a post-purchase upgrade (N6901A-1FP for N1913A, N6902A-1FP for N1914A).
Important: Option 101 (front-panel calibrator and sensors) cannot be ordered together with any of the B0x or C0x options.
Important: Option 201 requires Option B01 (without battery), which is mandatory for Option 201.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Factory New

Manufacturer

Keysight Technologies

Keysight W8486A Diode Power Sensor, 75 GHz to 110 GHz

W8486A

Keysight Q8486D Diode Power Sensor, 33 GHz to 50 GHz

Q8486D

Keysight V8486A Diode Power Sensor, 50 GHz to 75 GHz

V8486A

Keysight N8486AQ Thermocouple Power Sensor, 33 GHz to 50 GHz

N8486AQ

Keysight N8486AR Thermocouple Power Sensor, 26.5 GHz to 40 GHz

N8486AR

Keysight U2000B USB Power Sensor, 10 MHz to 18 GHz, -30 to +44 dBm

U2000B

Keysight U2002H USB Power Sensor, 50 MHz to 24 GHz, -50 to +30 dBm

U2002H

Keysight 8487D Diode Power Sensor, 50 MHz to 50 GHz, -70 to -20 dBm

8487D

Keysight U2002A USB Power Sensor, 50 MHz to 24 GHz, -60 to +20 dBm

U2002A

Keysight U2001B USB Power Sensor, 10 MHz to 6 GHz, -30 to +44 dBm

U2001B

Keysight U2000H USB Power Sensor, 10 MHz to 18 GHz, -50 to +30 dBm

U2000H

Keysight U2000A USB Power Sensor, 10 MHz to 18 GHz, -60 to +20 dBm

U2000A

Keysight N8487A Thermocouple Power Sensor, 50 MHz to 50 GHz, -35 to +20 dBm

N8487A

Keysight U2001H USB Power Sensor, 10 MHz to 6 GHz, -50 to +30 dBm

U2001H

Keysight N8482B High Power Thermocouple Power Sensor, 100 kHz to 6 GHz, -5 to +44 dBm

N8482B

Keysight N8481B High Power Thermocouple Power Sensor, 10 MHz to 18 GHz, -5 to +44 dBm

N8481B

Keysight E9300B E-Series Average Power Sensor, 10 MHz to 18 GHz, -30 to +44 dBm

E9300B

Keysight U2004A USB Power Sensor, 9 kHz to 6 GHz, -60 to +20 dBm

U2004A

Keysight U2001A USB Power Sensor, 10 MHz to 6 GHz, -60 to +20 dBm

U2001A

Keysight E9301B E-Series Average Power Sensor, 10 MHz to 6 GHz, -30 to +44 dBm

E9301B

Keysight 8485D Diode Power Sensor, 50 MHz to 26.5 GHz, -70 to -20 dBm

8485D

Keysight E9300H E-Series Average Power Sensor, 10 MHz to 18 GHz, -50 to +30 dBm

E9300H

Keysight E9300A E-Series Average Power Sensor, 10 MHz to 18 GHz, -60 to +20 dBm

E9300A

Keysight E4413A E-Series CW Power Sensor, 50 MHz to 26.5 GHz, -70 to +20 dBm

E4413A

Keysight N8485A Thermocouple Power Sensor, 10 MHz to 26.5 GHz, -35 to +20 dBm

N8485A

Keysight 8483A Thermocouple Power Sensor, 100 kHz to 2 GHz, 75-Ohm

8483A

Keysight N8482H High Power Thermocouple Power Sensor, 100 kHz to 6 GHz, -15 to +35 dBm

N8482H

Keysight N8481H High Power Thermocouple Power Sensor, 10 MHz to 18 GHz, -15 to +35 dBm

N8481H

Keysight E9301H E-Series Average Power Sensor, 10 MHz to 6 GHz, -50 to +30 dBm

E9301H

Keysight E9304A E-Series Average Power Sensor, 9 kHz to 6 GHz, -60 to +20 dBm

E9304A

Keysight 8481D Diode Power Sensor, 10 MHz to 18 GHz, -70 to -20 dBm

8481D

Keysight E9301A E-Series Average Power Sensor, 10 MHz to 6 GHz, -60 to +20 dBm

E9301A

Keysight E4412A E-Series CW Power Sensor, 10 MHz to 18 GHz, -70 to +20 dBm

E4412A

Keysight N8482A Thermocouple Power Sensor, 100 kHz to 6 GHz, -35 to +20 dBm

N8482A

Keysight N8481A Thermocouple Power Sensor, 10 MHz to 18 GHz, -35 to +20 dBm

N8481A

11730F Keysight Cable New

11730F

11730E Keysight Cable New

11730E

Keysight 82357B USB/GPIB Converter for N1913A/N1914A EPM Series

82357B

11730D Keysight Cable New

11730D

34131A Keysight Case New

34131A

11730C Keysight Cable New

11730C

11730B Keysight Cable New

11730B

11730A Keysight Cable New

11730A

10833G Keysight GPIB Cable New

10833G

10833F Keysight GPIB Cable New

10833F

10833C Keysight GPIB Cable New

10833C

10833B Keysight GPIB Cable New

10833B

10833A Keysight GPIB Cable New

10833A

10833D Keysight GPIB Cable New

10833D

34161A Keysight Accessory New

34161A