Key Features At A Glance

  • GPIB (IEEE-488), USB (USBTMC-USB488), and LAN 10/100BaseT interfaces, compliant to LXI Class C
  • Test frequency from 20 Hz up to 2 MHz across the series, with options limited to 1 MHz, 500 kHz, or 300 kHz
  • Four-terminal-pair measurement with OPEN, SHORT, and LOAD compensation functions
  • Basic measurement accuracy to ±0.05% (test-condition dependent per specifications)
  • Selectable series/parallel equivalent-circuit models across C, L, R, X, Z, G, B, Y, and D/Q parameters
  • 201-point list sweep and comparator bin-sort (9 BINs) for component sorting and pass/fail testing
  • Optional DC bias enhancement (Option 001) raises test signal to 20 Vrms and adds variable DC bias plus DCR
  • 320 × 240 RGB color LCD with measurement, comparator, and list-sweep display pages
View full details

The Agilent E4980A is a precision LCR meter that measures impedance and related component parameters across a test frequency span of 20 Hz to 2 MHz. The E4980AL designation covers the low-frequency configurations of the same instrument — 20 Hz to 300 kHz, 500 kHz, or 1 MHz — and is used only for ordering and shipment; the unit itself is labeled E4980A. The instrument is fully compliant to the LXI Class C specification.

As an impedance measurement instrument, the E4980A characterizes capacitors, inductors, and resistive components by reporting parameters such as capacitance, inductance, resistance, reactance, impedance, admittance, conductance, susceptance, and dissipation or quality factor. Its built-in comparator sorts a primary parameter into nine bins plus out-of-bin and auxiliary categories, with a secondary parameter classified HIGH, IN, or LOW, supporting component sorting and pass/fail evaluation. A 201-point list sweep allows a sequence of measurement points to be evaluated automatically.

ValueTronics stocks this equipment directly from our own 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units leave factory-sealed exactly as received from the manufacturer. That combination of real inventory and hands-on verification is what distinguishes a ValueTronics purchase.

Brand Heritage

Agilent Technologies began as the test-and-measurement arm of Hewlett-Packard, which spun the business off as Agilent Technologies in 1999. In 2014, Agilent's electronic measurement business was established as Keysight Technologies, the brand under which this product line is supported today.

Compare Other Models in This Series

The E4980A and E4980AL share a single hardware platform built around precision four-terminal-pair impedance measurement. The E4980A is the full-range model covering 20 Hz to 2 MHz, while the E4980AL is the ordering designation applied to frequency-limited configurations — 20 Hz to 1 MHz, 500 kHz, or 300 kHz. Because the physical unit is labeled E4980A in every case, the family is best understood as one meter offered at several upper-frequency limits.

Across the family the core measurement parameters, four-terminal-pair terminals, compensation functions, and interface set remain common; the configurations differ chiefly in maximum test frequency and in which options can be installed.

Each configuration linked below is its own product page with pre-owned-matched pricing. Select the model whose frequency range and installed options match your application, and review that page's specifications and availability for the pre-owned unit you intend to order.

The E4980A, as the full 20 Hz to 2 MHz model, is the configuration that accepts the Power and DC Bias enhancement (Option 001), the bias current interface (Option 002), and the entry/standard model options — capabilities the frequency-limited configurations do not accept per the installable-options table.

The primary difference across the family is the upper test-frequency limit: 2 MHz for the E4980A, and 1 MHz, 500 kHz, or 300 kHz for the E4980AL frequency options 100, 050, and 030 respectively. The comparison table below lists each configuration's frequency range alongside its ordering and product model numbers.

Option availability also differs by configuration. The installable-options table shows that the Power and DC Bias enhancement, bias current interface, and entry/standard model options apply only to the 2 MHz model, while DC resistance measurement is supplied by default on the frequency-limited units. The handler and scanner interfaces are installable across all configurations.

Model Frequency Range Basic Accuracy Max Test Signal Voltage
E4980A 20 Hz to 2 MHz ±0.05% 2 Vrms

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
Measurement Functions
Measurement parameters Cp-D, Cp-Q, Cp-G, Cp-Rp; Cs-D, Cs-Q, Cs-Rs; Lp-D, Lp-Q, Lp-G, Lp-Rp, Lp-Rdc; Ls-D, Ls-Q, Ls-Rs, Ls-Rdc; R-X; Z-θd, Z-θr; G-B; Y-θd, Y-θr; Vdc-Idc
Equivalent circuits for measurement Parallel, Series
Impedance range selection Auto (auto range mode), manual (hold range mode)
Trigger mode Internal trigger (INT), manual trigger (MAN), external trigger (EXT), GPIB trigger (BUS)
Measurement terminal Four-terminal pair
Test cable length 0 m, 1 m, 2 m, 4 m
Measurement time modes Short mode, medium mode, long mode
Averaging 1 - 256 measurements (resolution 1)
Trigger delay time 0 s - 999 s; resolution 100 µs (0 s - 100 s), 1 ms (100 s - 999 s)
Step delay time 0 s - 999 s; resolution 100 µs (0 s - 100 s), 1 ms (100 s - 999 s)
Test Signal — Frequency
Test frequency range 20 Hz - 2 MHz (standard); 20 Hz - 1 MHz (Option 100); 20 Hz - 500 kHz (Option 050); 20 Hz - 300 kHz (Option 030)
Resolution 0.01 Hz (20 Hz - 99.99 Hz); 0.1 Hz (100 Hz - 999.9 Hz); 1 Hz (1 kHz - 9.999 kHz); 10 Hz (10 kHz - 99.99 kHz); 100 Hz (100 kHz - 999.9 kHz); 1 kHz (1 MHz - 2 MHz)
Measurement accuracy ± 0.01%
Test Signal — Voltage (standard)
Range 0 Vrms - 2.0 Vrms
Resolution 100 µVrms (0 - 0.2 Vrms); 200 µVrms (0.2 - 0.5 Vrms); 500 µVrms (0.5 - 1 Vrms); 1 mVrms (1 - 2 Vrms)
Accuracy, Normal ±(10% + 1 mVrms) (test frequency ≤ 1 MHz: spec.; > 1 MHz: typ.)
Accuracy, Constant (ALC on) ±(6% + 1 mVrms) (test frequency ≤ 1 MHz: spec.; > 1 MHz: typ.)
Test Signal — Current (standard)
Range 0 Arms - 20 mArms
Resolution 1 µArms (0 - 2 mArms); 2 µArms (2 - 5 mArms); 5 µArms (5 - 10 mArms); 10 µArms (10 - 20 mArms)
Accuracy, Normal ±(10% + 10 µArms) (test frequency ≤ 1 MHz: spec.; > 1 MHz: typ.)
Accuracy, Constant (ALC on) ±(6% + 10 µArms) (test frequency ≤ 1 MHz: spec.; > 1 MHz: typ.)
Output impedance 100 Ω (nominal)
Test Signal Level Monitor Accuracy
Voltage monitor (Vac), 5 mVrms - 2 Vrms, ≤ 1 MHz ± (3% of reading value + 0.5 mVrms)
Voltage monitor (Vac), 5 mVrms - 2 Vrms, > 1 MHz ± (6% of reading value + 1 mVrms)
Current monitor (Iac), 50 µArms - 20 mArms, ≤ 1 MHz ± (3% of reading value + 5 µArms)
Current monitor (Iac), 50 µArms - 20 mArms, > 1 MHz ± (6% of reading value + 10 µArms)
Allowable Display Ranges
Cs, Cp ± 1.000000 aF to 999.9999 EF
Ls, Lp ± 1.000000 aH to 999.9999 EH
D ± 0.000001 to 9.999999
Q ± 0.01 to 99999.99
R, Rs, Rp, X, Z, Rdc ± 1.000000 aΩ to 999.9999 EΩ
G, B, Y ± 1.000000 aS to 999.9999 ES
Vdc ± 1.000000 aV to 999.9999 EV
Idc ± 1.000000 aA to 999.9999 EA
θr ± 1.000000 arad to 3.141593 rad
θd ± 0.0001 deg to 180.0000 deg
Δ% ± 0.0001 % to 999.9999 %
Basic Accuracy Ab — SHORT mode
20 - 125 Hz (0.6%)×(50 mVrms/Vs) [5-50 mVrms]; 0.60% [50-300 mVrms]; 0.30% [0.3-1 Vrms]; 0.30% [1-10 Vrms]; 0.30% [10-20 Vrms]
125 Hz - 1 MHz (0.2%)×(50 mVrms/Vs) [5-50 mVrms]; 0.20% [50-300 mVrms]; 0.10% [0.3-1 Vrms]; 0.15% [1-10 Vrms]; 0.15% [10-20 Vrms]
1 MHz - 2 MHz (0.4%)×(50 mVrms/Vs) [5-50 mVrms]; 0.40% [50-300 mVrms]; 0.20% [0.3-1 Vrms]; 0.30% [1-10 Vrms]; 0.30% [10-20 Vrms]
Basic Accuracy Ab — MED, LONG mode
20 - 100 Hz (0.25%)×(30 mVrms/Vs) [5-50 mVrms]; 0.25% [50-300 mVrms]; 0.10% [0.3-1 Vrms]; 0.15% [1-10 Vrms]; 0.15% [10-20 Vrms]
100 Hz - 1 MHz (0.1%)×(30 mVrms/Vs) [5-50 mVrms]; 0.10% [50-300 mVrms]; 0.05% [0.3-1 Vrms]; 0.10% [1-10 Vrms]; 0.15% [10-20 Vrms]
1 MHz - 2 MHz (0.2%)×(30 mVrms/Vs) [5-50 mVrms]; 0.20% [50-300 mVrms]; 0.10% [0.3-1 Vrms]; 0.20% [1-10 Vrms]; 0.30% [10-20 Vrms]
Temperature Factor Kt
0 - 18 °C 4
18 - 28 °C 1
28 - 55 °C 4
DC Bias Signal (standard)
Test signal voltage range 0 V to +2 V
Resolution 0 V / 1.5 V / 2 V only
Accuracy (23 °C ± 5 °C) 0.1% + 2 mV
Accuracy (0 to 18 °C or 28 to 55 °C) (0.1% + 2 mV) × 4
Output impedance 100 Ω (nominal)
DC bias test signal current (1.5 V/2.0 V) Output current: Max. 20 mA
Compensation Functions
OPEN compensation Compensates errors caused by the stray admittance (C, G) of the test fixture
SHORT compensation Compensates errors caused by the residual impedance (L, R) of the test fixture
LOAD compensation Compensates errors between the actual measured value and a known standard value under the measurement conditions desired by the user
List Sweep
Points Maximum of 201 points
First sweep parameter Test frequency, test signal voltage, test signal current, test signal voltage of DC bias signal, test signal current of DC bias signal, DC source voltage
Second sweep parameter None, impedance range, test frequency, test signal voltage, test signal current, test signal voltage of DC bias signal, test signal current of DC bias signal, DC source voltage
Trigger modes Sequential mode, Step mode
Comparator Function
Bin sort (primary) 9 BINs, OUT_OF_BINS, AUX_BIN, and LOW_C_REJECT
Bin sort (secondary) HIGH, IN, LOW
Sorting modes Sequential mode, tolerance mode
Important: Discharge capacitors before connecting them to the UNKNOWN terminal or a test fixture to avoid damage to the instrument.
Important: Front-panel UNKNOWN terminal maximum rating: 42 V Peak Max Output, 10 VDC Max, Measurement Category CAT I.
Important: Use the recommended USB memory device exclusively for the E4980A; otherwise previously saved data may be cleared. If a USB memory other than the recommended device is used, data may not be saved or recalled normally. Agilent Technologies will NOT be responsible for data loss in the USB memory caused by using the E4980A.
Recommended pairing: the Agilent 16047A/B/D/E test fixtures are the cable/fixture set referenced for the meter's specified four-terminal-pair measurements.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Backed by a ValueTronics warranty.
  • Functional verification included.
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Keysight Technologies

Lcr_met_freq

20 Hz to 2 MHz

16380C Agilent Standard Used

16380C

Keysight 3458A 8.5 Digit High-Performance Digital Multimeter (Pre-Owned)

3458A

16380A Agilent Standard Used

16380A

E4980AL Agilent LCR Meter Used

E4980AL

16451B Agilent Fixture Used

16451B

Agilent 16034G Test Fixture for Small SMD Components (2-Terminal, DC to 110 MHz) (Pre-Owned)

16034G

Agilent 16047E Test Fixture for Axial Lead Components (Pre-Owned)

16047E

Agilent 16034E Test Fixture for SMD Components (2-Terminal) for 4288A Capacitance Meter (Pre-Owned)

16034E

16089C Agilent Accessory Used

16089C

Agilent 16334A Tweezer-Type Test Fixture for SMD Components (2-Terminal, DC to 15 MHz) (Pre-Owned)

16334A

16089B Agilent Accessory Used

16089B

Agilent 16048E 3.8-Meter BNC Test Leads for 4263B LCR Meter (Pre-Owned)

16048E

16089A Agilent Accessory Used

16089A

16048A Agilent Accessory Used

16048A

Agilent 16047A Axial and Radial Test Fixture for 4263B LCR Meter (Pre-Owned)

16047A

Agilent 4083A DC/RF Parametric Test System (Pre-Owned)

4083A

Agilent E8362B PNA Series Network Analyzer for 4083A RF S-Parameter and RFCV Measurement (Pre-Owned)

E8362B