Skip to product information
1 of 0
New

Tektronix DPO1072S Digital Oscilloscope New

Tektronix DPO1072S Digital Oscilloscope New

Regular price $950
Sale price $950 Regular price $0
Shipping calculated at checkout.
Request a Quote

🎓 Request a Quote To Get An EDU Discount

Key Features At A Glance

The Tektronix DPO1072S is a 1 Series DPO digital oscilloscope with 2 analog channels, 70 MHz bandwidth, 1.25 GS/s (half channels) or 625 MS/s (all channels) sample rate, 10 Mpoints per channel record length, 12-bit vertical resolution and a built-in arbitrary function generator with sine output from 1 µHz to 25 MHz.

  • Analog channel bandwidth: 70 MHz
  • Analog channels: 2
  • Sample rate: 1.25 GS/s half channels; 625 MS/s all channels
  • Record length: 10 Mpoints per channel
  • Vertical resolution: 12 bits
View full details

What the Tektronix DPO1072S is and what it is used for

The Tektronix DPO1072S digital storage oscilloscope shows how a voltage changes over time, stores the waveform, measures it automatically and triggers on and decodes I2C, SPI and UART serial buses.

The Tektronix DPO1072S also includes a digital voltmeter with 5-digit resolution and a frequency counter with maximum 6-digit resolution.

The Tektronix DPO1072S adds an arbitrary function generator with one output and a Bode plot (frequency response) measurement, each with its own specification table on this page.

Tektronix DPO1072S key specifications

Model overview

Tektronix DPO1072S: Model overview
Parameter Value
Analog channel bandwidth 70 MHz
Analog channels 2
Sample rate 1.25 GS/s half channels; 625 MS/s all channels
Record length 10 Mpoints per channel
Waveform capture rate More than 125,000 waveforms per second
Vertical resolution 12 bits
AFG output 1

Vertical system

Tektronix DPO1072S: Vertical system
Parameter Value Conditions
Bandwidth selection 20 MHz and full instrument bandwidth based on model (50 MHz, 70 MHz, 100 MHz, 200 MHz) (limited by instrument bandwidth) —
Input coupling AC, DC —
Input impedance 1 MΩ ± 0.02 MΩ —
Input capacitance 17 pF (+1 pF / −2 pF) 1 MΩ DC coupled
Input sensitivity range 1 mV/div to 10 V/div —
DC gain accuracy ±3% full scale <5 mV/div
DC gain accuracy ±2% full scale ≥5 mV/div
Offset range ±2 V; ±25 V; ±250 V 1 mV/div to 50 mV/div: ±2 V; 55 mV/div to 1 V/div: ±25 V; 1.1 V/div to 10 V/div: ±250 V

Horizontal system

Tektronix DPO1072S: Horizontal system
Parameter Value Conditions
Timebase range 2 ns/div to 1 ks/div 70 MHz, 100 MHz, and 200 MHz bandwidth models
Timebase delay range −8 divisions to 4000 s —
Timebase accuracy ±25 ppm over any ≥1 ms interval (guaranteed for 10 years after factory calibration) —

Trigger system

Tektronix DPO1072S: Trigger system
Parameter Value
Trigger modes Auto, normal, and single
Trigger holdoff range 0 s to 10 s
Standard trigger types Edge, pulse width, runt, timeout, and rise/fall time
Serial bus trigger: I2C up to 10 Mb/s
Serial bus trigger: SPI up to 20 Mb/s
Serial bus trigger: RS-232/422/485/UART up to 15 Mb/s
Pulse width trigger range 0.8 ns to 4 s
Timeout trigger time limit (analog channels) 3.2 ns to 10 s
Trigger coupling: HF reject / LF reject above 40 kHz; below 40 kHz

Acquisition, measurements and math

Tektronix DPO1072S: Acquisition, measurements and math
Parameter Value
Average acquisition mode Average of a series of acquired waveforms up to 8192 acquisitions
Automatic measurements 23, with up to 21 that can be displayed as either individual measurement badges or collectively in a measurement results table
Number of math waveforms Up to 4
FFT window functions Kaiser-Bessel, Gaussian, Rectangular, Hamming, Hanning, Blackman-Harris, Flattop2, TekExp
Digital voltmeter DC, AC+DC RMS, AC RMS; 5-digit resolution
Frequency counter Frequency, maximum 6‑digit resolution

Bode plot (S models)

Tektronix DPO1072S: Bode plot (S models)
Parameter Value
Bode plot start frequency 50 Hz to 25 MHz
Bode plot stop frequency 60 Hz to 25 MHz
Bode plot amplitude (peak-to-peak), High-Z 20 mV to 5 V
Bode plot amplitude (peak-to-peak), 50 Ω 10 mV to 2.5 V

Arbitrary function generator (S models)

Tektronix DPO1072S: Arbitrary function generator (S models)
Parameter Value
Waveforms Sine, square, pulse, ramp, arbitrary, dc, and noise
Modulation frequency (AM / FM) 2 mHz to 50 kHz
Modulation frequency (ASK, FSK) 2 mHz to 50 kHz
Sweep time 1 ms to 500 s
DC offset accuracy ± (offset set value × 5% + 2 mV)
DC offset range ±2.49 V into High-Z, ±1.245 V into 50 Ω

Arbitrary function generator amplitude and frequency range (S models)

Tektronix DPO1072S: Arbitrary function generator amplitude and frequency range (S models)
Signal type Amplitude range 50 Ω Amplitude range 1 MΩ Frequency range
Sine 10 mV to 2.5 V 20 mV to 5 V 1 µHz to 25 MHz
Square 10 mV to 2.5 V 20 mV to 5 V 1 µHz to 10 MHz
Pulse 10 mV to 2.5 V 20 mV to 5 V 1 µHz to 10 MHz
Ramp 10 mV to 2.5 V 20 mV to 5 V 1 µHz to 400 kHz
DC level (offset) −1.25 V to 1.25 V −2.5 V to 2.5 V —
Random noise 10 mV to 2.5 V 20 mV to 5 V —
Arbitrary 10 mV to 2.5 V 20 mV to 5 V 1 µHz to 5 MHz

What decides whether the Tektronix DPO1072S fits

Analog bandwidth: is 70 MHz enough for the signal?

The Tektronix DPO1072S analog channel bandwidth is 70 MHz, and a 20 MHz bandwidth limit can be selected. Bandwidth should exceed the highest significant frequency in the signal; the rules of thumb in this section show the margin engineers commonly use.

Channel count: are 2 channels enough?

The Tektronix DPO1072S has 2 analog channels, and every signal that must be viewed at the same time needs its own channel.

Sample rate: what rate does the Tektronix DPO1072S sample at with all channels on?

The Tektronix DPO1072S samples at 1.25 GS/s with half of its channels in use and at 625 MS/s with all channels in use, so the rate halves when every channel is on.

Record length: how long can a capture run at full sample rate?

The Tektronix DPO1072S stores 10 Mpoints per channel; together with the sample rate in use, the record length sets how long a single capture can run at that rate.

Probes: what limits the measurement system?

The Tektronix DPO1072S includes one P2101 100 MHz 1x/10x probe per channel. The probe and the oscilloscope together set the system bandwidth, which is lower than either one alone, and the data sheet does not state the probe's bandwidth at its 1x setting.

Rules of thumb (not specifications)

Oscilloscope bandwidth versus signal. Bandwidth should be at least 3× the highest significant frequency in the signal for analog work, and about 5× the clock or fundamental for digital signals so the fifth harmonic is kept. Where the edge speed is known, size from rise time instead (see the rule of thumb “Rise time and bandwidth” on this page). Rule of thumb, not a specification.

Example with the Tektronix DPO1072S: The Tektronix DPO1072S has 70 MHz bandwidth, which by this rule covers analog signals up to about 23.3 MHz and digital clocks up to about 14 MHz (computed from the stated 70 MHz: ÷ 3 and ÷ 5).

Rise time and bandwidth. Instrument rise time ≈ 0.35 ÷ bandwidth for a Gaussian-type response (usual for lower-bandwidth scopes) and ≈ 0.40–0.45 ÷ bandwidth for a flat, sharp-roll-off response (usual at higher bandwidths). To measure an edge with small error, the measuring system's rise time should be about 3–5× faster than the edge. Rule of thumb, not a specification.

Example with the Tektronix DPO1072S: The data sheet states no rise time for the Tektronix DPO1072S. By this rule, the 70 MHz bandwidth corresponds to an instrument rise time of about 5 ns (computed from the stated 70 MHz: 0.35 ÷ 70 MHz).

Real-time sample rate versus bandwidth. The theoretical minimum is 2× the highest frequency; real-time oscilloscopes need at least about 2.5× their bandwidth with sin(x)/x interpolation, and 4–5× or more gives comfortable reconstruction. Check the rate with the number of channels actually in use. Rule of thumb, not a specification.

Example with the Tektronix DPO1072S: The Tektronix DPO1072S sample rate is about 17.9 times its 70 MHz bandwidth with half channels and about 8.93 times its 70 MHz bandwidth with all channels (computed from the stated 1.25 GS/s and 625 MS/s ÷ 70 MHz).

Converter resolution. Levels = 2 to the power of the bit count: 8 bits = 256, 10 bits = 1,024, 12 bits = 4,096, 16 bits = 65,536. Each extra bit halves the step size. Effective resolution in use is lower than the nominal bit count. Rule of thumb, not a specification.

Example with the Tektronix DPO1072S: The Tektronix DPO1072S has 12 bits vertical resolution, which is 4,096 levels (computed from the stated 12 bits: 2 to the power of 12).

Probe and instrument together. The measurement system is no faster than its slowest part. A probe should have at least the bandwidth of the instrument input; for Gaussian-type responses the combined rise time is roughly the root-sum-square of the two. Rule of thumb, not a specification.

Example with the Tektronix DPO1072S: The Tektronix DPO1072S includes the P2101 probe (100 MHz 1x/10x probe) for its 70 MHz bandwidth.

Tektronix DPO1072S options and what they change

Additional probes, accessories, power cord options and software for the Tektronix DPO1072S are listed on the Options tab.

Standard probes (one per channel, included)

Tektronix DPO1072S: Standard probes (one per channel, included)
Model / option Description
P2101 100 MHz 1x/10x probe

What you need with the Tektronix DPO1072S

Tektronix DPO1072S: What is included
Parameter Value
Probes one per channel
Installation and safety manual translated in English, Japanese, and Simplified Chinese
Embedded help
Power cord

Tektronix DPO1072S safety and limits

Tektronix DPO1072S: Safety and limits
Parameter Value
Maximum input voltage 135 VRMS, −400 V ≤ peak ≤ +400 V, CAT II
Use For indoor, non-residential use only

Other Tektronix DPO1072S specifications

Display, interfaces and general

Tektronix DPO1072S: Display, interfaces and general
Parameter Value
Display type 7-inch multi-touch capacitive display
Display resolution WSVGA 1024 × 600
USB interface One USB 2.0 host port (front); One USB 2.0 device port (back)
Ethernet interface One ethernet port, 10/100 Mb/s, LAN (VXI11)
Operating system Closed Linux
VESA mount 100 mm × 100 mm VESA interface
Security slot Rear-panel security slot connects to standard Kensington-style lock

Power, physical and environment

Tektronix DPO1072S: Power, physical and environment
Parameter Value
Line power (100 V to 240 V) ± 10% at 50 Hz to 60 Hz
Power consumption 45 W (maximum)
Height (instrument only) 174 mm (6.85 in)
Width (instrument only) 291 mm (11.45 in)
Depth (instrument only) 102 mm (4.02 in)
Weight (instrument only) 2.16 kg (4.8 lb)
Rackmount configuration 4U
Temperature – operating 0 °C to 50 °C
Temperature – non-operating −20 °C to 70 °C
Altitude – operating Up to 3,000 meters (9,842 feet)

Tektronix DPO1072S questions and answers

What is the analog bandwidth of the Tektronix DPO1072S?

The Tektronix DPO1072S analog channel bandwidth is 70 MHz. A 20 MHz bandwidth limit can also be selected.

How many analog channels does the Tektronix DPO1072S have?

The Tektronix DPO1072S has 2 analog channels. Each input is 1 MΩ with AC or DC coupling.

What is the sample rate of the Tektronix DPO1072S?

The Tektronix DPO1072S sample rate is 1.25 GS/s with half the channels in use and 625 MS/s with all channels in use.

What is the acquisition memory depth of the Tektronix DPO1072S?

The Tektronix DPO1072S record length is 10 Mpoints per channel.

What is the Tektronix DPO1072S used for?

The Tektronix DPO1072S is used to view, measure and decode signals in hardware design and debug, embedded and serial-bus work, and teaching labs. The Tektronix DPO1072S triggers on and decodes I2C, SPI and UART buses as standard.

What else is needed to use the Tektronix DPO1072S?

The Tektronix DPO1072S includes one P2101 100 MHz 1x/10x probe per channel, a power cord and the installation and safety manual. Additional probes for the Tektronix DPO1072S are listed on the Options tab.

Which options change the analog bandwidth of the Tektronix DPO1072S?

The Tektronix DPO1072S bandwidth is set by the model: the 1 Series DPO models are 50 MHz, 70 MHz, 100 MHz and 200 MHz, each with 2 or 4 inputs, and the S models add the arbitrary function generator. The data sheet lists no bandwidth upgrade option.

What is the maximum input voltage of the Tektronix DPO1072S?

The Tektronix DPO1072S maximum input voltage is 135 VRMS, −400 V ≤ peak ≤ +400 V, CAT II, as stated in the data sheet. The Tektronix DPO1072S input impedance is 1 MΩ ± 0.02 MΩ.

Does the Tektronix DPO1072S have a function generator?

The Tektronix DPO1072S has a built-in arbitrary function generator with one output, generating sine from 1 µHz to 25 MHz and arbitrary waveforms from 1 µHz to 5 MHz. The Tektronix DPO1072S also uses the generator for its Bode plot measurement from 50 Hz to 25 MHz.

How is an oscilloscope different from a logic analyzer?

An oscilloscope such as the Tektronix DPO1072S shows the analog shape of each signal over time. A logic analyzer records only the logic states of many digital lines at once.

How is an oscilloscope different from a spectrum analyzer?

An oscilloscope such as the Tektronix DPO1072S shows a signal over time, and its FFT math gives a frequency view of the captured waveform. A spectrum analyzer measures which frequencies a signal contains, and at what power, as its primary function.

Specifications are from the manufacturer's data sheet (1 Series DPO Digital Oscilloscope Datasheet, 48W-74276-0, 10 Nov 2026). Questions? Contact your Test Architect.

Updated 2026-11-24

Model No

Tektronix

Condition

New

Manufacturer

Tektronix-3

Channels

2

Frequency

70 MHz

Sampling rate

1.25 GS/s half channels; 625 MS/s all channels

TPP0100

100 MHz bandwidth, 10X attenuation, BNC interface.

TPP0200

200 MHz bandwidth, 10X attenuation, BNC interface.

P2221

6 MHz to 200 MHz bandwidth, 1X / 10X attenuation, BNC interface.

P6139B

500 MHz bandwidth, 10X attenuation, BNC interface.

P6101B

15 MHz bandwidth, 1X attenuation, BNC interface.

P3010

100 MHz bandwidth, 10X attenuation, BNC interface.

TCPA300

Current probe amplifier; 50 Ω feed-through termination (011-0049-XX) is required.

TCPA300 with TCP312A

DC to 100 MHz, 1 mA.

TCPA300 with TCP305A

DC to 50 MHz, 5 mA.

TCPA300 with TCP303

DC to 15 MHz, 5 mA.

TCPA400

Current probe amplifier; 50 Ω feed-through termination (011-0049-XX) is required.

TCPA400 with TCP404XL

DC to 2 MHz, 1 A.

TCP2020

DC to 50 MHz, 10 mA.

A621

5 Hz to 50 kHz, 10 mA to 2000 APEAK.

A622

DC to 100 kHz.

P6021A

120 Hz to 60 MHz, 2 mA/mV, 10 mA/mV.

P6022

935 Hz to 120 MHz, 1 mA/mV, 10 mA/mV.

TRCP3000

1 Hz to 16 MHz, 2 mV/A.

TRCP0600

12 Hz to 30 MHz, 10 mV/A.

TRCP0300

9 Hz to 30 MHz, 20 mV/A.

CT1

25 kHz to 1 GHz, 5 mV/mA.

CT2

1.2 kHz to 200 MHz, 5 mV/mA.

CT6

250 kHz to 2 GHz, 5 mV/mA.

P5100A

500 MHz bandwidth, 100X attenuation.

P6015A

75 MHz bandwidth, 1000X attenuation.

P5122

200 MHz bandwidth, 100X attenuation.

P5200A

50 MHz bandwidth, 50:1/500:1 attenuation.

1-RK

Rackmount kit.

1-SC

Carrying bag.

1-HC

Hard carrying case.

A0

North America power plug (115 V, 60 Hz).

A1

Universal Euro power plug (220 V, 50 Hz).

A2

United Kingdom power plug (240 V, 50 Hz).

A3

Australia power plug (240 V, 50 Hz).

A5

Switzerland power plug (220 V, 50 Hz).

A6

Japan power plug (100 V, 50/60 Hz).

A10

China power plug (50 Hz).

A11

India power plug (50 Hz).

A12

Brazil (60 Hz).

A99

No power cord.

E1

Universal euro bundle.

TEKSCOPE-STARTER

TekScope PC software bundles for various applications. Each of these bundles can be purchased as a 1-year subscription or as a perpetual license.

TEKSCOPE-ULTIMATE