Key Features At A Glance

  • Three-in-one handheld: dual-channel oscilloscope, 6,000-count true RMS DMM, and real-time data logger
  • Bandwidth from 20 MHz to 40 MHz across the series, with edge, pulse-width, pattern, and video triggering
  • Up to 200 MSa/s real-time sampling (single-channel interleaved; 100 MSa/s per channel)
  • Up to 125,000 points recording length with zoom for capturing non-repeating signals
  • Large 4.5-inch (320 x 240) color LCD distinguishes waveforms between two channels
  • 6,000-count true RMS DMM with voltmeter, ohmmeter, capacitance, diode and continuity; temperature/current optional
  • USB 2.0 full-speed connectivity with PC Link software for remote control and data transfer
  • 22 automatic scope measurements plus Dual Waveform Math (FFT available on U1604B)
View full details

The Keysight U1600 Series is a line of handheld digital oscilloscopes that combine a dual-channel scope, a 6,000-count true RMS digital multimeter, and a real-time data logger in a single portable instrument. Built around a 4.5-inch color LCD that clearly distinguishes waveforms between its two channels, the series is positioned as a high-performance troubleshooting and quality-assurance tool for technical professionals working in installation, maintenance, service, and automotive environments.

The series is intended for the demanding conditions of today's industrial environments, giving installation, maintenance, service, and automotive technicians one rugged tool for both waveform and meter measurements. Beyond fully featured oscilloscope operation, the integrated true RMS DMM and real-time data logger let a technician capture, measure, and record a sequence of readings without carrying separate instruments to the job.

ValueTronics stocks and holds the U1600 Series in our own 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, rather than sourcing each order on demand. Because we physically hold our inventory, every pre-owned unit is inspected and functionally verified in-house against the original manufacturer specifications before it ships, while new units leave factory-sealed exactly as received. Buying from a specialist that keeps the equipment on its own shelves means faster fulfillment and verified condition on every used instrument.

Brand Heritage

The U1600 Series carries a measurement lineage that traces back to Hewlett-Packard in 1939. Hewlett-Packard's test-and-measurement business was spun off as Agilent Technologies in 1999, and that business became Keysight Technologies in 2014 — the brand under which these instruments are produced today.

Compare Other Models in This Series

The Keysight U1600 Series brings oscilloscope, true RMS digital multimeter, and real-time data logger capability together in a single handheld instrument designed for field and bench troubleshooting. The series comprises the U1602B and U1604B, each a dual-channel scope paired with a 6,000-count true RMS DMM and built around the same 4.5-inch color display.

Across the series, both models share a real-time sampling rate of up to 200 MSa/s, up to 125,000 points of recording length, advanced triggering, and USB 2.0 connectivity with PC Link software. The two models are distinguished primarily by their bandwidth and a small set of analysis features.

Each pre-owned model below is its own dedicated product page with condition-matched pricing. Select the model and configuration that fits your application, and review the comparison table to confirm bandwidth and feature differences before ordering.

The principal difference between the two models is bandwidth: the U1602B provides DC to 20 MHz, while the U1604B extends to DC to 40 MHz. That difference carries through to rise time, specified at under 17.5 ns on the U1602B and under 8.8 ns on the U1604B, and to the horizontal timebase, which reaches 50 ns/div on the U1602B and 10 ns/div on the U1604B.

The U1604B additionally provides an FFT function with four windowing techniques and a 2.5 GSa/s equivalent sampling rate for repetitive signals, neither of which is part of the U1602B specification. Both models otherwise share the same dual-channel acquisition, 200 MSa/s real-time sampling, 125,000-point memory, and integrated true RMS DMM, as detailed in the comparison table below.

Model Bandwidth Rise Time Timebase Resolution
U1602B 20 MHz < 17.5 ns 2 ns
U1604B 40 MHz < 8.8 ns 400 ps

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • U1561A 10:1 Scope probe (x2 units)
  • U1580A Test leads
  • U1162A Alligator clips
  • USB cable
  • U1570A AC power adapter and cord
  • U1571A Ni-MH battery pack
  • Quick Start Guide
  • Certificate of calibration

Product Core & Specifications

Specification Value
Vertical System: Scope Channels
Analog channels Channel 1 and Channel 2 simultaneous acquisition
Bandwidth (–3 dB) DC to 20 MHz
DC vertical gain accuracy 5 mV/div to 20 mV/div: ± 5% full scale; 50 mV/div to 100 V/div: ± 3% full scale
AC coupled < 10 Hz without probe; < 1 Hz with 10 MΩ 10:1 probe
Rise time < 17.5 ns
Single shot bandwidth 20 MHz
Vertical sensitivity 5 mV/div to 100 V/div (1:1 scope probe); 50 mV/div to 1 kV/div (10:1 scope probe); 500 mV/div to 10 kV/div (100:1 scope probe)
Maximum input CAT III 300 Vrms (up to 400 Hz) from terminal to ground
Offset/Dynamic range ± 5 div
Input impedance 1 MΩ || < 20 pF
Coupling AC, DC, GND
Acquisition: Scope Channels
Maximum sample rate 100 MSa/s per channel (50 s/div to 250 ns/div); 200 MSa/s single channel and interleaved (125 ns/div)
Vertical resolution 8 bits
Maximum recording length Up to 125 000 points, viewable on screen with zoom function
Peak detection 5 ns
Average Selectable in average number of 2, 4, 8, 16, 32, 64, 128, 256
Scope Channel Triggering
Trigger sensitivity DC to 5 MHz: 0.8 divisions; 5 MHz to 20 MHz: 1 division
Scope Characteristics
Probes U1560-60001: 1:1 passive probe; U1561-60001: 10:1 passive probe; U1562-60001: 100:1 passive probe
Probe attenuation factors 1x, 10x, 100x
Coupling 3 Vp-p, ~ 1 kHz
Maximum probe input 1x CAT III 300 VAC; 10x, 100x CAT III 600 VAC
Noise peak-to-peak 3% of full scale or 5 mV, whichever is greater
DC vertical offset accuracy ± 0.1% div ± 2 mV ± 0.5% offset value
Single cursor accuracy 4% full scale
Dual cursor accuracy 4% full scale
Horizontal System
Range 50 ns to 50 s/div
Resolution 2 ns
Reference position Left, center, right
Delay range (pre-trigger) 15 divisions
Delay range (post-trigger) 1000 divisions
Analog Δt accuracy ± 3% reading ± 0.4% screen
Modes Main, XY, Roll
RMS Jitter 5% of horizontal scale or 5 ns, whichever is higher
Trigger System
Source Channel 1 and Channel 2
Modes Auto, normal, single
Selections Edge, pulse width, pattern, video
Edge Trigger on a rising or falling edge of any source
Pattern Trigger at the beginning of a pattern of high, low levels and rising or falling edge established conditions of AND, OR, NOR and NAND between the channels.
Pulse Width 200 ns to 10 s. Trigger when a positive or negative pulse width of any source larger than, less than, equal to or not equal to duration.
Video Video trigger sensitivity: 0.7 division trigger level. Available to both Channel 1 and Channel 2. Analog progressive and interlaced video standards including NTSC, PAL and SECAM. Positive or negative sync pulse polarity. Modes – all fields, even fields, odd fields or line 5 – 263 within a field.
Range ± 4 divisions from center screen
Level accuracy ± 0.5 divisions
Trigger sensitivity DC to 5 MHz: 0.8 divisions; 5 MHz to 20 MHz: 1 division
Coupling DC, AC (< 1 Hz), HF reject (> 50 kHz), LF reject (< 30 kHz), Noise reject
Measurement System
Autoscale Finds and displays all active scope channels, sets edge trigger mode on highest numbered channel, sets vertical sensitivity on scope channel. Requires voltage > 20 mVp-p, 0.5% duty cycle and frequency > 100 Hz.
Automatic measurement Measurements continuously updated.
Voltage Peak-to-peak, maximum, minimum, amplitude, top, base, +overshoot, –overshoot, preshoot, RMS, mean and one cycle mean.
Time Frequency, period, +width, –width, and +duty cycle and –duty cycle on any channel. Rise time, fall time, delay and phase shift.
Cursors Manually place readout of horizontal (X, ∆X) and vertical (Y, ∆Y).
Waveform math CH1 + CH2, CH1 – CH2, CH2 – CH1
Digital Multimeter Specifications ± (% reading + % range), 1 year Tcal ± 5 ºC
DC Voltage (600.0 mV / 6.000 V / 60.00 V / 600.0 V) 0.3 + 0.08
AC Voltage (600.0 mV – 600.0 V), 50 Hz – 1 kHz 1.0 + 0.2
AC Voltage (600.0 mV – 600.0 V), 1 kHz – 30 kHz 3.0 + 0.2
AC + DC Voltage (6.000 V – 600.0 V), 50 Hz – 1 kHz 1.0 + 0.2
AC + DC Voltage (6.000 V – 600.0 V), 1 kHz – 30 kHz 3.0 + 0.2
Resistance (600.0 Ω / 6.000 kΩ / 60.00 kΩ / 600.0 kΩ / 6.000 MΩ) 0.5 + 0.2
Resistance (60.00 MΩ) 1.0 + 0.2
Capacitance (60.00 nF / 600.0 nF / 6.000 μF / 60.00 μF / 300.0 μF) 2.0 + 0.2
Diode (1.000 V, 0.5 mA) 2.0 + 0.08
Auxiliary Meter Specifications ± (% of reading + % of range), 1 year Tcal ± 5 ºC
Temperature, ºC (600.0 ºC) 0.3 + 0.08
Temperature, ºC (6000 ºC) 0.3 + 0.08
Temperature, ºF (600.0 ºF) 0.3 + 0.08
Temperature, ºF (6000 ºF) 0.3 + 0.08
AC Current (60.00 A), 50 Hz – 1 kHz 1.0 + 0.2
Important: Maximum scope input: CAT III 300 Vrms (up to 400 Hz) from terminal to ground.
Important: Auxiliary measurements (temperature and ampere) require additional accessories that are offered as optional and are not included with the standard instrument.
Important: Temperature measurement requires the U1586B Temperature module (or U1586A), which is available as an option and is not supplied with the standard instrument.
Important: Up to 10 waveform and configuration setups can be stored in internal memory and recalled; this can only be done on the instrument and the data is not extracted to a USB drive.
Important: The 200 MSa/s sampling rate is only available at the 125 ns/div timebase.
Recommended pairing: add the U1586B temperature module (used with the U1181A, U1182A, or U1183A probes) to enable Type-K temperature measurements through the instrument's DMM inputs.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Pre-Owned

Manufacturer

Keysight Technologies

Osc_ch

2

Osc_freq

20 MHz

Osc_r

1 MΩ

Osc_sampl

200 MSa/s