Skip to content

The Rohde & Schwarz R&S SGT100A is an I/Q-modulated SGMA vector RF source. In its base configuration it generates signals across a frequency range of 1 MHz to 3 GHz, with an optional frequency extension raising the upper limit to 6 GHz. It is described as a dedicated ATE digital source, built around a wear-free electronic attenuator and controlled through high-speed PCI Express, Ethernet, and USB interfaces.
As a dedicated ATE digital source, the R&S SGT100A is designed for automated test environments where fast and repeatable signal generation is required. The external R&S SGMA GUI software enables remote control of multiple instruments, and the instrument is field-upgradeable so its capabilities can be expanded over time. With the appropriate options it generates modulated signals for cellular, wireless-connectivity, navigation, and broadcast digital standards, and supports envelope-tracking and predistortion test setups.
ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer. Holding inventory on-site lets our team match the right instrument and option configuration to each application and ship it promptly.
Rohde & Schwarz is an independent, privately held company headquartered in Munich, Germany, founded more than 80 years ago. It has operated under the Rohde & Schwarz name throughout its history, with no major corporate renaming or acquisition affecting its brand identity.
| Specification | Value |
|---|---|
| Frequency | |
| Frequency range, CW mode | 1 MHz to 3 GHz |
| Frequency range, I/Q mode, internal baseband | 1 MHz to 3 GHz |
| Frequency range, I/Q mode, external analog | 80 MHz to 3 GHz |
| Frequency range, CW mode (with R&S®SGT-KB106 option) | 1 MHz to 6 GHz |
| Frequency range, I/Q mode, internal baseband (with R&S®SGT-KB106 option) | 1 MHz to 6 GHz |
| Frequency range, I/Q mode, external analog (with R&S®SGT-KB106 option) | 80 MHz to 6 GHz |
| Resolution of setting | 0.001 Hz |
| Resolution of synthesis (f = 1 GHz) | 0.174 µHz (nom.) |
| Setting time, arbitrary frequency change | < 500 μs |
| Setting time, baseband frequency offset change | < 150 µs |
| Resolution of phase offset setting | 0.1° |
| Reference frequency | |
| Frequency error at time of calibration in production | < 1 · 10–7 |
| Frequency error (with R&S®SGT-B1 option) | < 1 · 10–8 |
| Aging (after 30 days of uninterrupted operation) | < 1 · 10–6/year |
| Aging (with R&S®SGT-B1 option) | < 1 · 10–9/day, < 1 · 10–7/year |
| Temperature effect (0 °C to +50 °C) | < 2 · 10–6 |
| Temperature effect (with R&S®SGT-B1 option) | < 1 · 10–7 |
| Warm-up time to nominal thermostat temperature (with R&S®SGT-B1 option only) | ≤ 10 min |
| Reference frequency output level | +6 dBm to +12 dBm; 9 dBm (typ.) |
| Reference frequency output source impedance | 50 Ω (nom.) |
| Reference frequency input frequency | 10 MHz, 13 MHz, 100 MHz, 1000 MHz |
| Frequency locking range | ±10 · 10–6 |
| Reference frequency input level range | 0 dBm to +16 dBm |
| Reference frequency input impedance | 50 Ω (nom.) |
| Level | |
| Setting range | –120 dBm to +25 dBm |
| Specified level range | –120 dBm to +17 dBm (PEP) |
| Resolution of setting | 0.01 dB |
| Level error (auto, +18 °C to +33 °C, 1 MHz ≤ f ≤ 3 GHz, level ≤ 15 dBm) | < 0.5 dB |
| Level error (1 MHz ≤ f ≤ 3 GHz, 15 dBm < level ≤ 17 dBm) | < 0.7 dB |
| Level error (3 GHz < f ≤ 6 GHz) | < 0.9 dB |
| Additional level error for pulse modulation (pulse width ≥ 100 ns) | < 0.3 dB (meas.) |
| Output impedance VSWR in 50 Ω system (full frequency range, auto) | < 1.8 |
| Setting time, arbitrary level change | < 500 μs |
| Setting time, digital attenuation (0 dB to –80 dB) | < 100 µs |
| Interruption-free level setting range (uninterrupted level setting) | 0 dB to +20 dB |
| Reverse power from 50 Ω (maximum permissible RF power in output) | 0.5 W |
| Maximum permissible DC voltage at RF power connector | 35 V |
| Spectral purity | |
| Harmonics (level ≤ 8 dBm, CW, I/Q wideband off) | < –30 dBc |
| Nonharmonics (level > –10 dBm, offset > 10 kHz, f ≤ 1500 MHz) | < –76 dBc |
| Nonharmonics (1500 MHz < f ≤ 3000 MHz) | < –70 dBc |
| Nonharmonics (3000 MHz < f ≤ 6000 MHz) | < –64 dBc |
| Subharmonics (level > –10 dBm, f ≤ 3000 MHz) | < –76 dBc |
| Subharmonics (3000 MHz < f ≤ 6000 MHz) | < –68 dBc |
| Wideband noise (1 MHz ≤ f ≤ 6 GHz, 10 MHz offset, level > 5 dBm, 1 Hz BW, CW) | < –145 dBc |
| Wideband noise (1 MHz ≤ f ≤ 6 GHz, 10 MHz offset, level > 5 dBm, 1 Hz BW, I/Q) | < –135 dBc |
| SSB phase noise (20 kHz offset, 1 Hz BW, f = 1 GHz) | < –126 dBc; –133 dBc (meas.) |
| SSB phase noise (f = 2 GHz) | < –120 dBc; –127 dBc (meas.) |
| SSB phase noise (f = 6 GHz) | < –110 dBc; –117 dBc (meas.) |
| Pulse modulation (R&S®SGT-K22 option) | |
| Modulation source | external, internal |
| On/off ratio | > 80 dB |
| Rise/fall time (10 % to 90 % of RF amplitude) | < 20 ns |
| External pulse modulation delay | 45 ns (meas.) |
| Pulse repetition frequency | 0 Hz to 10 MHz |
| Video feedthrough (level < 10 dBm) | < 10 % of RF |
| Pulse overshoot (f ≥ 500 MHz) | < 10 % |
| Internal pulse generator pulse period setting range | 100 ns to 100 s |
| Internal pulse generator pulse period setting resolution | 10 ns |
| Pulse width setting range | 20 ns to 100 s |
| Pulse width setting resolution | 10 ns |
| Pulse delay setting range (with external trigger) | 0 s to 100 s |
| Double pulse delay setting range | 40 ns to 100 s |
| External trigger delay jitter | < 20 ns |
| Pulse/video output (USER2 connector, trigger mode auto) | LVTTL signal, 3.3 V (nom.) |
| I/Q modulator | |
| Operating modes | external analog I/Q, internal baseband I/Q |
| RF modulation bandwidth (external analog, wideband off, 80 MHz ≤ f ≤ 1 GHz) | ±5 % of carrier frequency |
| RF modulation bandwidth (external analog, wideband off, 1 GHz < f ≤ 6 GHz) | ±50 MHz |
| RF modulation bandwidth (external analog, wideband on, 100 MHz < f ≤ 2.5 GHz) | ±20 % of carrier frequency |
| RF modulation bandwidth (external analog, wideband on, 2.5 GHz < f ≤ 6 GHz) | ±500 MHz |
| RF modulation bandwidth (internal baseband, wideband on, 1 MHz < f ≤ 100 MHz) | frequency range from 1 MHz to 120 MHz |
| RF modulation bandwidth (internal baseband, wideband on, 100 MHz < f ≤ 600 MHz) | ±20 % of carrier frequency |
| RF modulation bandwidth (internal baseband, wideband on, f > 600 MHz) | ±120 MHz |
| Carrier leakage (external analog, referenced to full-scale input) | < –45 dBc; < –55 dBc (meas.) |
| Suppression of image sideband (internal baseband I/Q, up to 120 MHz I/Q bandwidth) | > 45 dB; 60 dB (typ.) |
| Analog I/Q inputs | |
| Connector types (I, Q on rear panel) | SMA female (BNC female with R&S®SGT-B88 option) |
| Input impedance | 50 Ω (nom.) |
| VSWR (up to 100 MHz) | < 1.2 |
| VSWR (100 MHz up to 500 MHz) | < 1.5 |
| Input voltage for full-scale input | √(Vi² + Vq²) = 0.5 V (nom.) |
| Input damage voltage | ±1 V |
| Internal baseband I/Q | |
| D/A converter resolution | 16 bit |
| Aliasing filter bandwidth (drop to –0.1 dB) | 120 MHz (nom.) |
| D/A converter interpolation spectra (up to 120 MHz) | < –80 dBc |
| I offset, Q offset setting range | –10 % to +10 % |
| Gain imbalance setting range | –1 dB to +1 dB |
Important: Maximum permissible reverse RF power at the output: 0.5 W. Maximum permissible DC voltage at the RF power connector: 35 V.
Important: R&S®WinIQSIM2™ requires an external PC; the digital modulation system options (e.g. 5G NR, LTE, GSM/EDGE, 3GPP FDD, WLAN, navigation and broadcast standards) generate their waveforms with R&S®WinIQSIM2 on an external PC.
Important: Recommended calibration interval is 3 years for 40 h/week operation in the full range of the specified environmental conditions.
Recommended pairing: the optional R&S SGT-K18 digital baseband connectivity provides a lossless digital I/Q link to other Rohde & Schwarz instruments such as the R&S SMW200A vector signal generator.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Rohde
Condition
Pre-Owned
Manufacturer
Rohde & Schwarz
Rf_gen_freq
1 MHz to 3 GHz
K200
Waveform package for signals from R&S®WinIQSIM2™1) , R&S®Pulse Sequencer and R&S®Pulse Sequencer (DFS) (1 Waveform)
K510
ARB baseband generator , 32 Msample , 60 MHz RF bandwidth
KB106
Frequency extension to 6 GHz
Request A Quote