Skip to product information
1 of 0
New

SDS7804A H12 Siglent Digital Oscilloscope New

SDS7804A H12 Siglent Digital Oscilloscope New

Regular price $64,800
Sale price $64,800 Regular price $0
Shipping calculated at checkout.
Optional:
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

🎓 Request a Quote To Get An EDU Discount

Key Features At A Glance

The Siglent SDS7804A-H12 is an SDS7000A Series A model rated 8 GHz (limited to 4 GHz in 3 or 4 channels modes), with 4 analog channels sampling at 20 GSa/s (2 channels) or 10 GSa/s (3 or 4 channels), a 12-bit ADC, 500 Mpts/ch of standard memory and a 15.6” HD TFT-LCD with capacitive touch screen (1920*1080) display.

  • Waveform update rate: 1,000,000 wfm/s, 1,100,000 wfm/s in sequence mode
  • Digital channels: 16-channel; maximum sample rate up to 1 GSa/s; record length up to 50 Mpts
  • Bandwidth (-3 dB) @ 1 MΩ, with probe: 500 MHz
  • Input impedance, 1 MΩ: (1 MΩ ± 2%) || (15 pF ± 3 pF)
  • ENOB (typical): 6.9-bit
  • Serial trigger protocols, standard: I2C, SPI, UART, CAN, LIN
  • Max. input voltage, 50 Ω: ≤ 5 Vrms, ± 10V Peak
View full details

What the Siglent SDS7804A-H12 is and what it is used for

The Siglent SDS7804A-H12 is a bench digital storage oscilloscope for high-speed signal, serial bus, power and mixed-signal work. The SDS7000A Series is available in bandwidths of 8 GHz, 6 GHz, 4 GHz and 3 GHz; the Siglent SDS7804A-H12 is the 8 GHz model. The data sheet describes 3 distinct hardware platforms: 3-4 GHz SDS7000A, 6-8 GHz SDS7000A, and SDS7000AP.

The Siglent SDS7804A-H12 uses SPO technology with a waveform update rate of 1,000,000 wfm/s, 1,100,000 wfm/s in sequence mode, segmented memory (Sequence) and a History mode that keeps past frames for playback.

Siglent SDS7804A-H12 key specifications

Conditions the data sheet sets for its specifications:

  • The oscilloscope has been working continuously for at least 30 minutes at the specified temperature

Vertical system, analog channels

Siglent SDS7804A-H12: Vertical system, analog channels (data sheet EN04A p.12, 13)
Parameter Value Conditions
Rise time, 50 Ω 58 ps note 1
Rise time, 50 Ω (maximum) < 65 ps note 1
Bandwidth (-3 dB) @ 1 MΩ, with probe 500 MHz —
Bandwidth (-3 dB) @ 1 MΩ, with external 50 Ω 300 MHz —
Vertical scale, 1 MΩ (probe 1X) 1 mV/div - 10 V/div —
Vertical scale, 50 Ω (probe 1X) 1 mV/div - 1 V/div —
DC gain accuracy, 1 mV/div ~ 4.95 mV/div ±2.0% FS 8 GHz and 6 GHz columns
DC gain accuracy, 5 mV/div ~ 10 V/div ±1.5% FS max. ±0.5% FS typical 8 GHz and 6 GHz columns
Offset accuracy ± (1% of the offset setting + 0.5% of full scale + 0.02% of max offset + 1 mV) —
Offset range, 1 MΩ (probe 1X) 1 mV/div ~ 5 mV/div: ±1.6 V; 5.1 mV/div ~ 10 mV/div: ±4 V; 10.2 mV/div ~ 20 mV/div:±8 V; 20.5 mV/div ~ 100 mV/div: ±16 V; 102 mV/div ~ 200 mV/div: ±80 V; 205 mV/div ~ 1 V/div: ±160 V; 1.02 V/div ~ 10 V/div: ±400 V —
Offset range, 50 Ω (probe 1X) 1 mV/div ~ 5 mV/div: ±1.6 V; 5.1 mV/div ~ 10 mV/div: ±4 V; 10.2 mV/div ~ 20 mV/div:±8 V; 20.5 mV/div ~ 1 V/div: ±10 V —
Bandwidth limit 25 MHz±20%, 200 MHz±20%, Custom —
Low frequency response (AC coupling -3 dB) 6 Hz —
Coupling DC, AC, GND —
Input impedance, 1 MΩ (1 MΩ ± 2%) || (15 pF ± 3 pF) 8 GHz and 6 GHz models
Input impedance, 50 Ω 50 Ω ± 2% —
SFDR ≥ 45dBc —
Channel-to-channel isolation (@ 50 Ω) 60 dB up to 500 MHz; 40 dB up to 6 GHz —
Probe attenuation 1X, 10X, 100X, custom —
ENOB (typical) 6.9-bit 8 GHz column (note 2)

Note 1: Enhanced Bandwidth = ON, and Type = Best Flatness

Note 2: 50 Ω, 50 mV/div, 20 GSa/s, -1dBFS/47.999 MHz input

Model overview

Siglent SDS7804A-H12: Model overview (data sheet EN04A p.3, 4, 12)
Parameter Value Conditions
Bandwidth (-3 dB), 50 Ω 8 GHz; limited to 4 GHz in 3 or 4 channels modes Enhanced Bandwidth = ON, and Type = Best Flatness (p.12 note 1)
Analog channels 4 plus an external trigger input (EXT)
Sample rate 20 GSa/s (2 channels) 2 channels: C1/C2 are not both active, and C3/C4 are not both active (note 1)
Sample rate, 3 or 4 channels 10 GSa/s (3 or 4 channels) —
Vertical resolution (ADC) 12-bit —
Vertical resolution in ERES mode Up to 16-bit in ERES mode —
Memory depth, standard 500 Mpts/ch A models
Memory depth, optional (SDS7000A-1GPTS) 1 Gpts/ch in dual-channel mode —
Maximum memory depth in Average and Hi-Res modes 25 Mpts/ch —
Maximum memory depth with digital channels active 100 Mpts/ch —
Waveform update rate 1,000,000 wfm/s, 1,100,000 wfm/s in sequence mode —
Display 15.6” HD TFT-LCD with capacitive touch screen (1920*1080) —
Digital channels 16-channel; maximum sample rate up to 1 GSa/s; record length up to 50 Mpts with the SPL2016 16-channel logic probe (optional accessory, p.28)

Note 1: 2 channels: C1/C2 are not both active, and C3/C4 are not both active

Noise floor at this model's bandwidth (rms, 50 Ω, typical)

Conditions: 8 GHz column

Siglent SDS7804A-H12: Noise floor at this model's bandwidth (rms, 50 Ω, typical) (data sheet EN04A p.13)
Parameter Value
≤ 5 mV/div 300 μV
10 mV/div 340 μV
20 mV/div 490 μV
50 mV/div 1.0 mV
100 mV/div 2.0 mV
200 mV/div 5.5 mV
500 mV/div 11 mV
1 V/div 20 mV

Data sheet p.13, the column of this model's bandwidth.

Acquisition

Siglent SDS7804A-H12: Acquisition (data sheet EN04A p.12)
Parameter Value
Real-time signal processing depth Measure, math, decode, analysis: 100 Mpts/ch max.
Intensity grading 256-level
Peak detect 100 ps
Average 4, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096, 8192
ERES Enhanced bit: 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4 bit
Sequence (segmented memory) Up to 124,000 segments, interval between triggers = 0.9 μs min.
History Up to 124,000 frames
Interpolation sinx/x, x

Horizontal system

Siglent SDS7804A-H12: Horizontal system (data sheet EN04A p.14)
Parameter Value Conditions
Time scale 0.05 ns/div - 1000 s/div —
Roll mode ≥ 50 ms/div —
Skew (C1~C4) ± 50 ps 8 GHz and 6 GHz columns
Time base accuracy, standard (TCXO) ±2 ppm initial (0~50°C); ±0.5 ppm 1st year aging; ±3 ppm 20-year aging —
Time base accuracy, optional (OCXO) ±100 ppb initial (25°C); ±1 ppb over temperature (0~50°C); ±50 ppb 1st year aging OCXO timebase: assembled and calibrated in factory only (p.31)

Trigger system

Siglent SDS7804A-H12: Trigger system (data sheet EN04A p.3, 14, 15, 16)
Parameter Value Conditions
Trigger types Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold, Delay, Serial —
Trigger level Internal: ±4.5 div from the center of the screen; EXT: ± 0.61 V; EXT/5: ± 3.05 V —
Hold off range, by time 4 ns ~ 30 s (4 ns step) —
Trigger coupling, C1 ~ C4 DC; AC: Blocks DC components and attenuates signals below 15 Hz; LFRJ: Attenuates the frequency components below 2.4 MHz; HFRJ: Attenuates the frequency components above 1.3 MHz; Noise RJ —
Trigger accuracy C1 ~ C4: ±0.2 div; EXT: ±0.3 div —
Trigger sensitivity, C1 ~ C4 (50 Ω), > 10 mV/div (Noise RJ off; on) 1.0 div; 1.5 div —
Trigger sensitivity, C1 ~ C4 (50 Ω), (1 mV/div, 10 mV/div] (Noise RJ off; on) 2.4 div; 2.6 div —
Trigger sensitivity, C1 ~ C4 (50 Ω), 1 mV/div (Noise RJ off; on) 3.5 div; 4.0 div —
Trigger sensitivity, EXT 200 mVpp, DC ~ 10 MHz; 300 mVpp, 10 MHz ~ bandwidth (300 MHz) —
Trigger jitter, C1 ~ C4 < 9 ps RMS (typical) for ≥ 300 MHz sine ≥ 6 divisions peak to peak amplitude, vertical gain settings from 2.5 mV/div to 10 V/div
Trigger jitter, C1 ~ C4 (≥ 500 MHz sine) < 5 ps RMS (typical) for ≥ 500 MHz sine ≥ 6 divisions peak to peak amplitude, vertical gain settings from 2.5 mV/div to 10 V/div
Zone trigger Up to 2 zones; Source: C1 ~ C4; Property: Intersect, Not Intersect —
Edge trigger source C1 ~ C4/ EXT/ (EXT/5)/ AC Line/ D0~D15 —
Time range (slope, pulse width, interval, dropout, runt, pattern, delay triggers) 2 ns ~ 20 s, Resolution = 0.2 ns —
Serial trigger protocols, standard I2C, SPI, UART, CAN, LIN —
Serial trigger protocols, optional CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, ARINC429 each with its trigger & decode software option (Options tab)

Digital channels

Siglent SDS7804A-H12: Digital channels (data sheet EN04A p.24)
Parameter Value
Max. sampling rate 1 GSa/s
Memory depth 50 Mpts/ch
Min. detectable pulse width 3.3 ns
Level group D0~D7, D8~D15
Level range -10 V ~ 10 V
Logic type TTL, CMOS, LVCMOS3.3, LVCMOS2.5, Custom
Skew D0 ~ D15: ±1 sampling interval; Digital to Analog: ± (1 sampling interval +1 ns)

Computer, display and interfaces

Siglent SDS7804A-H12: Computer, display and interfaces (data sheet EN04A p.2, 26)
Parameter Value
CPU Intel Core i3-8100 or better
System memory 32 GB DDR4
Storage 250 GB SSD or better
Operating system Linux
Front panel I/O 2x USB 3.0 Host; Calibration signal for passive probe: 1 kHz, 3 V Square
Side panel USB and LAN 4x USB Host 3.1 Gen 1, 2x 1000M LAN (VXI-11+SCPI, Telnet (5024) +SCPI, Socket (5025) +SCPI, LXI, WebServer)
Side panel video outputs 1x DVI-D: up to 1920x1200 @ 60Hz, 1x DP 1.2: up to 4096x2304 @ 60Hz, 1x HDMI 1.4: up to 4096x2160 @ 60Hz
Side panel audio Mic input, Audio Output
Rear panel USB 2.0 Device (USBTMC); External trigger in; Aux out: TRIG OUT(3.3 V LVCMOS), PASS/FAIL OUT(3.3 V TTL); 10 MHz In, 10 MHz Out
Display resolution 1920×1080
Remote control Built-in web server supports remote control over the LAN port using a web browser. Supports SCPI remote control commands.

Compare the Siglent SDS7804A-H12 with other models

Siglent SDS7804A-H12: compare SDS7000A Series (data sheet EN04A p.3, 12, 13)
Model Bandwidth (-3 dB), 50 Ω Sample rate Memory depth, standard ENOB (typical)
SDS7804AP 8 GHz * 20 GSa/s @ all channels 1 Gpts/ch (1 or 2 channels) 6.9-bit *
SDS7604AP 6 GHz * 20 GSa/s @ all channels 1 Gpts/ch (1 or 2 channels) 7.1-bit *
SDS7804A-H12 (this page) 8 GHz; limited to 4 GHz in 3 or 4 channels modes 20 GSa/s (2 channels) * 500 Mpts/ch 6.9-bit *
SDS7604A-H12 6 GHz; limited to 4 GHz in 3 or 4 channels modes 20 GSa/s (2 channels) * 500 Mpts/ch 7.1-bit *
SDS7404A-H12 4 GHz * 20 GSa/s (2 channels) * 500 Mpts/ch 7.1-bit *
SDS7304A-H12 3 GHz * 20 GSa/s (2 channels) * 500 Mpts/ch 7.3-bit *

* Enhanced Bandwidth = ON, and Type = Best Flatness

* 50 Ω, 50 mV/div, 20 GSa/s, -1dBFS/47.999 MHz input

* 2 channels: C1/C2 are not both active, and C3/C4 are not both active

What decides whether the Siglent SDS7804A-H12 fits

Bandwidth: is 8 GHz enough, and on how many channels?

The Siglent SDS7804A-H12 reaches 8 GHz at 50 Ω (typical rise time 58 ps) when it samples at 20 GSa/s (2 channels); it is limited to 4 GHz in 3 or 4 channels modes, where the A models sample at 10 GSa/s (3 or 4 channels). The AP models of the series do not have this limit. At 1 MΩ with the probe the bandwidth is 500 MHz.

Memory: how long can the Siglent SDS7804A-H12 capture?

The Siglent SDS7804A-H12 has 500 Mpts/ch of standard memory; option SDS7000A-1GPTS gives 1 Gpts/ch in dual-channel mode. Average and Hi-Res modes, and active digital channels, lower the maximum, as the overview table shows.

Small signals: how quiet is the Siglent SDS7804A-H12?

At its own bandwidth the Siglent SDS7804A-H12 has a typical noise floor of 300 μV rms at its most sensitive settings and 1.0 mV at 50 mV/div (50 Ω), with a 12-bit ADC and an ENOB of 6.9-bit. ERES mode trades bandwidth for resolution (Up to 16-bit in ERES mode).

Logic: can the Siglent SDS7804A-H12 watch digital lines too?

The Siglent SDS7804A-H12 has digital inputs; the data sheet lists the SPL2016 16-channel logic probe as an optional accessory.

Analysis: which tools does the Siglent SDS7804A-H12 have?

The Siglent SDS7804A-H12 data sheet lists these analysis functions: Search, Navigate, History, Mask Test, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis, Eye/Jitter Analysis, SignalScan (Power and Eye/Jitter Analysis are options). Automatic measurements on 60+ parameters, supports statistics with histogram, track, trend, Gating measurement, and measurements on Math, History and Memory traces; 4 Math traces (32 Mpts FFT, Filter, addition, subtraction, multiplication, division, integration, differential, square root, etc.), supports formula editor. Built-in Mask Editor application helps to create custom masks.

Serial buses: which can the Siglent SDS7804A-H12 trigger on and decode?

The Siglent SDS7804A-H12 triggers on and decodes I2C, SPI, UART, CAN, LIN as standard; the other protocols in its trigger table, and decode-only protocols such as CAN XL and USB 2.0, are software options listed on the Options tab.

Spectrum: does the Siglent SDS7804A-H12 have a spectrum analyzer mode?

Option SDS7000A-RFA adds a Spectrum Analyzer mode to the Siglent SDS7804A-H12; in that mode it supports the functions of a Real-Time Spectrum Analyzer (RTSA) and Digital Down Conversion (DDC), at analysis bandwidths of 125 MHz, 250 MHz, 500 MHz, 1 GHz, and SigVSA signal analysis options build on it.

Signal source: does the Siglent SDS7804A-H12 need a separate generator?

Option SDS7000A-FG adds a built-in 50 MHz waveform generator to the Siglent SDS7804A-H12. The Bode plot sweeps 10 Hz ~ 120 MHz from it or from SDG series generators.

Upgrades: can the Siglent SDS7804A-H12 grow later?

The Siglent SDS7804A-H12 has the top bandwidth of its hardware platform, so the data sheet lists no bandwidth upgrade for it. It is not possible to upgrade between platforms. Bandwidth upgrades are available within the same platform only. Memory can be added by licence (SDS7000A-1GPTS).

Rules of thumb (not specifications)

Oscilloscope bandwidth versus signal. Bandwidth should be at least 3× the highest significant frequency in the signal for analog work, and about 5× the clock or fundamental for digital signals so the fifth harmonic is kept. Where the edge speed is known, size from rise time instead. Rule of thumb, not a specification.

Example with the Siglent SDS7804A-H12: The Siglent SDS7804A-H12 has 8 GHz bandwidth (it is limited to 4 GHz in 3 or 4 channels modes), which by this rule covers analog signals up to about 2.67 GHz and digital clocks up to about 1.6 GHz (computed from the stated 8 GHz: ÷ 3 and ÷ 5).

Siglent SDS7804A-H12 options and what they change

Software options, memory and bandwidth upgrades, probes and accessories that the data sheet lists for the Siglent SDS7804A-H12 are on the Options tab.

What you need with the Siglent SDS7804A-H12

Siglent SDS7804A-H12: Probes and accessories named in the data sheet (data sheet EN04A p.4, 10, 28)
Parameter Value Conditions
Standard probe named in the data sheet 500 MHz, 1 probe supplied for each channel named in the data sheet; accessories that come with a particular unit are not part of the data sheet
Standard passive probe model SP3150A; 1/channel named in the data sheet; accessories that come with a particular unit are not part of the data sheet
SAP8000D differential probe 8 GHz bandwidth, 300 fF differential input capacitance, and 10:1 attenuation ratio described on p.10; not in the optional accessories list (p.28)

Siglent SDS7804A-H12 safety and limits

Siglent SDS7804A-H12: Safety and limits (data sheet EN04A p.13, 14, 26)
Parameter Value
Max. input voltage, 1 MΩ ≤ 400 Vpk(DC + AC), DC ~ 10 kHz
Max. input voltage, 50 Ω ≤ 5 Vrms, ± 10V Peak
Ext trigger channel input voltage, 1 MΩ ≤ 42 Vpk
Ext trigger channel input voltage, 50 Ω ≤ 5 Vrms
Rear external trigger input EXT: ≤1.5 Vrms, EXT/5: ≤ 7.5Vrms

Other Siglent SDS7804A-H12 specifications

Measurement, math and analysis

Siglent SDS7804A-H12: Measurement, math and analysis (data sheet EN04A p.3, 19, 20)
Parameter Value
Automatic measurements 60+ parameters, statistics, histogram, trend, and track supported
Math traces 4 traces
FFT length 32 Mpts
Mask test speed Up to 80,000 frames/s
Digital voltmeter modes DC mean, DC RMS, AC RMS, Peak-peak, Amplitude
Counter frequency resolution 7 digits
Bode plot frequency range 10 Hz ~ 120 MHz
Bode plot signal sources Built-in waveform generator, SAG1021I (Connection: USB), SDG series waveform generators (Connection: USB, LAN)
Power analysis measurements (option SDS7000A-PA) Power quality, Current Harmonics, Inrush current, Switching loss, Slew rate, Modulation, Output ripple, Turn on/turn off, Transient response, PSRR, Efficiency, SOA

Spectrum Analyzer mode (option SDS7000A-RFA, A models only)

Siglent SDS7804A-H12: Spectrum Analyzer mode (option SDS7000A-RFA, A models only) (data sheet EN04A p.21)
Parameter Value
Bandwidth 125 MHz, 250 MHz, 500 MHz, 1 GHz
RTSA probability of intercept (POI) 1.76 μs @ 500 MHz bandwidth

Waveform generator (option SDS7000A-FG)

Siglent SDS7804A-H12: Waveform generator (option SDS7000A-FG) (data sheet EN04A p.25)
Parameter Value
Channels 1
Max. output frequency 50 MHz
Sampling rate 125 MSa/s
Vertical resolution 14 bit
Waveforms Sine, Square, Ramp, Pulse, DC, Noise, 45 Arbitrary
Amplitude range -1.5 V ~ +1.5 V (into 50 Ω); -3 V ~ +3 V (into High-Z)
Sine frequency 1 μHz ~ 50 MHz
Square/pulse frequency 1 μHz ~ 10 MHz
Arbitrary waveform memory 16 kpts

Power, size and environment

Siglent SDS7804A-H12: Power, size and environment (data sheet EN04A p.27)
Parameter Value Conditions
Operating temperature 0 °C ~ 50 °C —
Non-operating temperature -30 °C ~ 60 °C —
Operating humidity 5% ~ 90%RH, 30°C, degraded to 50%RH at 40 °C —
Operating altitude ≤ 3,048 m, 25 °C —
Input voltage & frequency 100 ~ 240 Vrms 50/60Hz —
Power consumption 400 W max., 210 W typical, 4 W typical in standby mode A models
Dimensions (W × H × D) Without feet: 444.5mm × 334mm × 176.4mm; With feet: 444.5mm×367mm×176.4mm —
Weight Net Weight 10.6 kg; Gross Weight 17.0 kg —

Tables kept in the data sheet

Siglent SDS7804A-H12: Tables kept in the data sheet
Specification Where in the data sheet
Horizontal range and display modes; Trigger table: mode, EXT coupling, 1 MΩ sensitivity, EXT jitter, displacement, video standards, Nth edge and the per-type trigger settings; serial decoder settings Data sheet p.14, Horizontal
Analysis: eye/jitter clock recovery, equalization and jitter decomposition; FFT windows; measurement display and statistics counts; spectrum analyzer FFT lengths, sweep time, DDC data and SigVSA Data sheet p.20, Analysis
Bandwidth in ERES mode (typical), per enhanced bit; vertical range Data sheet p.12, Vertical (analog)

Siglent SDS7804A-H12 questions and answers

What is the Siglent SDS7804A-H12 used for?

The Siglent SDS7804A-H12 captures and analyzes high-speed analog and digital signals. The data sheet points its power analysis option at switching power supplies and power devices design, its hardware mask test at long-term signal monitoring or automated production line testing, and its eye and jitter option at serial data links.

Can the Siglent SDS7804A-H12 be controlled from a PC?

The Siglent SDS7804A-H12 connects over LAN or USB (USBTMC), with a built-in web server and SCPI commands, as the interfaces table shows.

Specifications are from the manufacturer's data sheet (SDS7000A Series Digital Storage Oscilloscope Data Sheet, EN04A, no printed date). Questions? Contact your Test Architect.

Updated 2026-11-26

Model No

SDS7804A

Condition

New

Manufacturer

Siglent

Channels

4

Frequency

8 GHz; limited to 4 GHz in 3 or 4 channels modes

Sampling rate

20 GSa/s (2 channels)

SDS7000A-FG

Waveform generator (software).

SDS7000A-PA

Power Analysis (software).

SDS7000A-EJ

Eye Diagram/Jitter Analysis (software).

SDS7000A-I2S

I2S trigger & decode (software).

SDS7000A-1553B

MIL-STD-1553B trigger & decode (software).

SDS7000A-FlexRay

FlexRay trigger & decode (software).

SDS7000A-CANFD

CAN FD trigger & decode (software).

SDS7000A-CANXL

CAN XL decode (software).

SDS7000A-SENT

SENT trigger & decode (software).

SDS7000A-Manch

Manchester decode (software).

SDS7000A-USB2

USB 2.0 decode (software).

SDS7000A-ARINC

ARINC429 trigger & decode (software).

SDS7000A-SpaceWire

SpaceWire decode (software).

SDS7000A-SPMI

SPMI decode (software).

SDS7000A-8B10B

8B/10B decode (software).

SDS7000A-RFFE

MIPI RFFE decode (software).

SDS7000A-CT-USB2

USB 2.0 compliance test (software).

SDS7000A-CT-10BASE-T

10Base-T compliance test (software).

SDS7000A-CT-100BASE-T

100Base-TX compliance test (software).

SDS7000A-CT-1000BASE-T

1000Base-T compliance test (software).

SDS7000A-CT-2.5/5/10GBASE-T

2.5G/5G/10G Base-T compliance test (software).

SDS7000A-CT-10BASE-T1S

10Base-T1S compliance test (software).

SDS7000A-CT-100BASE-T1

100Base-T1 compliance test (software).

SDS7000A-CT-1000BASE-T1

1000Base-T1 compliance test (software).

SDS7000A-CT-DP

MIPI-DPHY compliance test (software).

SDS7000A-CT-DDR

DDR2/DDR3/DDR4 compliance test (software).

SDS7000A-CT-PCIE

PCIe 1.0/2.0 compliance test (software).

SDS7000A-RFA

RTSA / DDC / Signal Analysis (software), A models.

SIGV-VSAL1

SigVSA: LTE/LTE-A FDD demodulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAL2

SigVSA: LTE/LTE-A TDD demodulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAN1

SigVSA: 5G NR/NR-A Modulation Analysis. Provides options for NR/NR-A demodulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAN2

SigVSA: 5G NR-NTN modulation analysis. Provides options for NR-NTN demodulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAW1

SigVSA: WLAN 802.11b/a/g/n/ac/ax demodulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAW2

SigVSA: WLAN 802.11be demodulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAU1

SigVSA: HRP-UWB with various bandwidths demodulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAG3

SigVSA: NB-Iot downlink modulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAG1

SigVSA: GSM/EDGE modulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAG2

SigVSA: WCDMA/HSPA modulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAB1

SigVSA: Bluetooth modulation analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAF1

SigVSA: Frequency-Hopping Signal analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAF2

SigVSA: FMCW Signal analysis for linear frequency modulation (chirp) signal analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAP1

SigVSA: Pulse signal analysis (only available when SDS7000A-RFA is unlocked).

SIGV-VSAV1

SigVSA: DVB-S2\S2X modulation analysis (only available when SDS7000A-RFA is unlocked).

SDS7000A-1GPTS

1Gpts memory depth (software), A models.

10M_OCXO_L

OCXO timebase (Assembled and calibrated in factory only).

SP3150A

Passive probe.

SPL2016

16-channel logic probe: input impedance 100 kΩ || 18 pF, input range ±20 V, min. input swing 800 mVpp, max. data rate 300 Mbps (with leadset), 100 Mbps (without leadset).

SP6150A

High-speed passive probe: 1.5 GHz, 10X, input impedance 1.8 pF || 500 Ω.

SAP5000D

High-speed differential probe: 5 GHz, 10X, differential input impedance 400 fF || 20 kΩ, input range ±2.5 V, offset range ±12 V, SAPBus interface.

SAP2500D

High-speed differential probe: 2.5 GHz, 10X, differential input impedance 1 pF || 200 kΩ, input range ±4 V, offset range ±8 V, SAPBus interface.

SAP2500

High-speed active probe: 2.5 GHz, 10X, input impedance 1.1 pF || 1 MΩ, input range ±8 V, offset range ±12 V, SAPBus interface.

SAP1000

High-speed active probe: 1 GHz, 10X, input impedance 1.2 pF || 1 MΩ, input range ±8 V. offset range ±12 V, SAPBus interface.

SAP4000P

Power rail probe: DC - 4 GHz, 1.1X, input impedance 50 kΩ@low frequency, 50 Ω@high frequency, input range ± 600 mV, offset range ± 24 V, SAPBus interface.

HPB4010

High voltage passive probe: DC-40MHz, 1000X, input impedance 3.0 pF || 100 MΩ, Max. input differential voltage DC: 0~10 kVDC, AC: ≤ 7 kVrms (Sinewave), 20 kVp-p (Pulse).

DPB1300

High voltage differential probe: 50 MHz, 50X/500X, Max. Differential Test Voltage (DC + Peak AC) ±1300 V, CATIII 600 V/CATII 1000 V, DC 12 V Power supply.

DPB5150

High voltage differential probe: 70 MHz, 50X/500X, Max. Differential Test Voltage (DC + Peak AC) ±1500 V, CATIII 600 V/CATII 1000 V, USB 5 V Power supply.

DPB5150A

High voltage differential probe: 100 MHz, 50X/500X, Max. Differential Test Voltage (DC + Peak AC) ±1500 V, CATIII 600 V/CATII 1000 V, USB 5 V Power supply.

DPB5700

High voltage differential probe: 70 MHz, 100X/1000X, Max. Differential Test Voltage (DC + Peak AC) ±7000 V, CATIII 1000V, USB 5 V Power supply.

DPB5700A

High voltage differential probe: 100 MHz, 100X/1000X, Max. Differential Test Voltage (DC + Peak AC) ±7000 V, CATIII 1000V, USB 5 V Power supply.

SCP5030

Current probe: DC-50 MHz, 1 V/A and 0.1 V/A, Max. current 30 Arms/50 Apk, 300V, SAPBus interface.

SCP5030A

Current probe: DC-100 MHz, 1 V/A and 0.1 V/A, Max. current 30 Arms/50 Apk, 300V, SAPBus interface.

SCP5150

Current probe: DC-12 MHz, 0.1 V/A and 0.01 V/A, Max. current 150 Arms/300 Apk, CAT III 300 V/CAT II 600 V, SAPBus interface.

SCP5500

Current probe: DC-2 MHz, 0.1 V/A and 0.01 V/A, Max. current 500 Arms/750 Apk, CAT III 300 V/CAT II 600 V, SAPBus interface.

CPL5100

Current probe: DC-600 kHz, 0.1 V/A and 0.01 V/A, current range 50 mA~100 A pk, DC 12 V Power supply.

CP4020

Current probe: DC-200 kHz, 50 mV/A and 5 mV/A, Max. current 20 Arms/60 Ap-p, CAT III 600 V/CAT II 600 V, DC 9 V Power supply.

CP4050

Current probe: DC-1 MHz, 500 mV/A and 50 mV/A, Max. current 50 Arms/140 Ap-p, CAT III 300 V/CAT II 600 V, DC 9 V Power supply.

CP4070

Current probe: DC-300 kHz, 50 mV/A and 5 mV/A, Max. current 70 Arms/200 Ap-p, CAT III 600 V/CAT II 600 V, DC 9 V Power supply.

CP4070A

Current probe: DC-300 kHz, 100 mV/A and 10 mV/A, Max. current 70 Arms/200 Ap-p, CAT III 600 V/CAT II 600 V, DC 9 V Power supply.

CP6030

Current probe: DC-50 MHz, 1 V/A and 0.1 V/A, Max. current 30 Arms/50 Apk, 300V, DC 12 V Power supply.

CP6030A

Current probe: DC-100 MHz, 1 V/A and 0.1 V/A, Max. current 30 Arms/50 Apk, 300V, DC 12 V Power supply.

CP6150

Current probe: DC-12 MHz, 0.1 V/A and 0.01 V/A, Max. current 150 Arms/300 Apk, CAT III 300 V/CAT II 600 V, DC 12 V Power supply.

CP6500

Current probe: DC-5 MHz, 0.1 V/A and 0.01 V/A, Max. current 500 Arms/750 Apk, CAT III 300 V/CAT II 600 V, DC 12 V Power supply.

DF2001A

Power Analysis deskew fixture.

STB3

STB3 demo signal source.

USB-GPIB

USB-GPIB adapter.

CASE-S2

Transit case.

SDS7000A-RMK

Rack Mount Kit.

FX-USB2

USB 2.0 test fixture.

FX-ETH

10M/100M/1000M Ethernet test fixture.

FX-MGETH

2.5G/5G/10G Ethernet test fixture.

FX-AMETH

Automotive Ethernet test fixture.

FX-PCIE

PCIe 1.0/2.0/3.0 test fixture.