The Tektronix PWS4000 Series is a family of programmable linear DC power supplies. A wide current and voltage range combined with flexible features makes the series a versatile addition to the bench, delivering the output a design specifies quickly and precisely. All five models share linear regulation, an overvoltage protection circuit, and the familiar front-panel operation Tektronix builds into its bench instruments.
The series generates controlled DC power for a device under test. Setting an appropriate current limit can be critical for preventing damage to the device under test, and the numeric keypad lets you specify that limit precisely before a test begins, with the limit always visible on the display. List mode and the USB port for remote programming are provided to accelerate complex test development.
ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit we sell is inspected and functionally verified in-house before it ships, while new units leave our warehouse factory-sealed exactly as received from the manufacturer.
The PWS4000 Series comprises five programmable linear DC power supplies that share a single feature set and differ in their output voltage and current ratings. Across the family, a wide current and voltage range and flexible features make the series a versatile addition to the bench.
All models include the same core capabilities: an adjustable overvoltage protection circuit, remote sense, List mode, 40 setup memories, a bright vacuum fluorescent display, and a USBTMC device port for remote programming. Choosing a model is primarily a matter of matching the voltage and current your application requires.
Each model below links to its own dedicated product page with pre-owned pricing. Select the model whose voltage and current rating matches your application, then choose the available condition on that model's page.
The five models differ chiefly in output rating: voltage ranges from 0–20 V on the lowest model up to 0–72 V on the highest, while current ratings reach up to 5 A on the lower-voltage models and step down as the voltage rating rises. Maximum output power falls between 86 W and 150 W depending on the model.
Physical size is common across the series at 88 mm × 214 mm × 355 mm, with weight varying from 9.0 kg to 9.6 kg and rated power consumption of either 250 VA or 350 VA depending on the model. The comparison table below lists each model's voltage, current, power, and related specifications side by side.
| Model | Output Voltage | Output Current | Maximum Power |
|---|---|---|---|
| PWS4305 | 0 to 30 V | 0 to 5 A | 150 W |
| PWS4205 | 0 to 20 V | 0 to 5 A | 100 W |
| PWS4323 | 0 to 32 V | 0 to 3 A | 96 W |
| PWS4602 | 0 to 60 V | 0 to 2 A | 150 W |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| DC Output Rating | |
| Voltage | 0 to 30 V |
| Current | 0 to 5 A |
| Maximum Power | 150 W |
| Load Regulation | |
| Voltage | <0.01% + 2 mV |
| Current | <0.05% + 1.5 mA |
| Line Regulation | |
| Voltage | <0.01% + 1 mV |
| Current | <0.05% + 0.1 mA |
| Ripple and Noise (20 Hz to 7 MHz) | |
| Voltage | <1 mVRMS, <4 mVp-p |
| Current | <4 mARMS |
| Setting Resolution | |
| Voltage | 1 mV |
| Current | 0.1 mA |
| Setting Accuracy (using remote sense, 25 °C ± 5 °C) | |
| Voltage | ±0.03% + 3 mV |
| Current | ±0.05% + 2.5 mA |
| Readback Resolution | |
| Voltage | 1 mV |
| Current | 0.1 mA |
| Readback Accuracy (25 °C ± 5 °C) | |
| Voltage | ±0.02% + 2.5 mV |
| Current | ±0.05% + 2.5 mA |
| Overvoltage Protection | |
| Range (typical) | 1 V to 29 V |
| Accuracy | ±0.5% + 0.5 V |
| Response time (typical) | <10 ms |
| Display | |
| Display | Vacuum fluorescent display |
| Memory | |
| Setup memories | 40 setup memories |
| List Mode | |
| Lists | Up to 7 lists can be defined, each with up to 80 steps. Each step includes a voltage limit and a current limit. For continuous sequences each step also includes a duration. |
| Rear-panel Connections | |
| Communications | USB Device Port, Type B connector, USBTMC compatible; GPIB, optional (requires TEK-USB-488 GPIB to USB adapter) |
| Output, Sense, Status, and Control | Removable screw terminal block carries the output channel (duplicates the front-panel outputs), remote sense lines, control input (multifunction TTL input which can function as a trigger input, output control line, or digital input), and status output (multifunction TTL output which can function as a fault indication or digital output) |
| Power Source | |
| 110 V AC Setting | 99 VRMS to 132 VRMS |
| 220 V AC Setting | 198 VRMS to 264 VRMS |
| Frequency | 47 Hz to 63 Hz |
| Power Consumption | 350 VA |
| Physical Characteristics | |
| Height | 88 mm (3.47 in.) |
| Width | 214 mm (8.45 in.) |
| Depth | 355 mm (13.9 in.) |
| Weight | 9.6 kg (21.2 lb.) |
| Environmental and Safety | |
| Temperature, Operating | 0 °C to +40 °C |
| Temperature, Storage | –20 °C to +70 °C |
| Relative Humidity, Operating | 5% to 95% relative humidity at up to +40 °C |
| Relative Humidity, Storage | 5% to 95% relative humidity at up to +40 °C; 5% to 60% RH above +40 °C up to +70 °C |
| Altitude, Operating | Up to 2,000 m |
| Altitude, Storage | Up to 4,000 m |
| Electromagnetic Compatibility | European Union: EN 55011, Class A; IEC 61000-3-2; IEC 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11. USA: FCC, CFR Title 47, Part 15, Subpart B, Class A. Australia: EMC Framework, demonstrated per Emission Standard AS/NZS 2064 (Industrial, Scientific, and Medical Equipment) |
| Safety | European Union: Low Voltage directive 2006/95/EC; EN61010-1 2001. USA: Nationally recognized testing laboratory listing UL61010-1-2004. Canada: CAN/CSA C22.2 No. 61010-1 2004 |
| Warranty | |
| Warranty | Three years |
Important: Specify the power plug and preferred language option when ordering.
Important: GPIB connectivity is optional and requires the TEK-USB-488 GPIB to USB adapter (not included with the instrument).
Usage tip: pair the supply with the TEK-USB-488 GPIB to USB adapter to add the optional GPIB interface for automated test systems.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Tektronix
Condition
Pre-Owned
Manufacturer
Tektronix
Dcsup_amps
5 A
Dcsup_volts
30 V
Dcsup_watts
150 W