  • Wide measurable range: 10 µA to 30 A, 60 mV to 1000 V across voltage and current inputs
  • Basic accuracy of ±0.1% for voltage, current, and power (see Specifications for full conditions)
  • Frequency bandwidth: DC, 0.1 Hz to 100 kHz (values within 0.1 Hz to 10 Hz are reference only per datasheet)
  • Power factor effect of ±0.1% f.s. at 45 to 66 Hz with PF = 0 for accurate low-power-factor measurement
  • Built-in harmonic measurement to the 50th order, compliant with IEC 61000-4-7:2002 for IEC 62301 standby power testing
  • Crest factor of 6: peak value up to ±600% of each voltage and current range
  • LAN standard on all models; RS-232C, GP-IB, D/A output, and external current sensor input available per model variant
  • Synchronized control of up to 8 units including PW3336 and PW3337 series for input/output efficiency measurement
View full details

The Hioki PW3335 is a single-phase AC/DC power meter designed for high-accuracy measurement spanning standby power through full operating power. The instrument provides a wide measurable range from 10 µA to 30 A on the current input and 60 mV to 1000 V on the voltage input, with basic accuracy specified at ±0.1% for voltage, current, and power. Frequency bandwidth covers DC and 0.1 Hz to 100 kHz, with built-in harmonic measurement to the 50th order.

Applications listed in the datasheet include measurement of AC adapter standby power on both primary-side AC and secondary-side DC, characterization of power supply conversion devices such as inverters and thyristors, and measurement of solar panels and power converters using the 1000 V range. The PW3335 is also positioned for evaluation and development of power sources for home appliances, for input and output measurement of secondary batteries in EVs, and for measuring the sold power of solar panels, with power consumption and regeneration power integrated separately.

ValueTronics stocks the PW3335 family alongside Hioki current sensors, sensor units, and the connection accessories required for full system deployment. All inventory is housed and processed at our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois, where instruments are inspected and verified before shipment. Unlike pass-through brokers and drop-shippers, we maintain the instrument in-house, which means availability questions, configuration confirmations, and accessory compatibility checks are answered against units we can physically reference.

Brand Heritage

Hioki E.E. Corporation has operated as an independent Japanese precision measurement manufacturer since 1935, headquartered in Ueda, Nagano. The company has not been absorbed into a larger conglomerate, and the Hioki brand has remained continuous on the PW-series power meter line through its successive generations.

Compare Other Models in This Series

The PW3335 family is a single product platform offered in five configurations that differ only in installed interface and input options. The base PW3335 includes LAN and RS-232C. The PW3335-01 substitutes GP-IB for RS-232C. The PW3335-02 adds D/A output to the base LAN and RS-232C configuration.

All five variants share the same measurement engine: identical voltage and current ranges, identical accuracy specifications, identical frequency bandwidth, identical harmonic measurement capability, and identical synchronized control of up to 8 units. The selection decision is driven entirely by the interface and input requirements of the user's bench or automated test system.

Each new PW3335 variant below links to its own product page with condition-matched pricing. The model number is the determinant of which interfaces and inputs ship with the unit; the underlying measurement instrument is the same across the family.

The differences between the five variants are interface-specific. LAN is included on every model. RS-232C is included on every model except the PW3335-01 (which substitutes GP-IB). GP-IB is included only on the PW3335-01 and PW3335-04.

Buyers building automated test systems on GP-IB infrastructure typically select the PW3335-01 or PW3335-04. Buyers requiring analog output to a data logger or Memory HiCorder typically select the PW3335-02 or PW3335-04. Buyers measuring current above the 30 A direct-input range — using Hioki clamp-on or AC/DC current sensors for measurements up to 5000 A AC — require the PW3335-03 or PW3335-04. The PW3335-04 is the all-options variant for users who need GP-IB, D/A output, and external current sensor input together.

Model LAN RS-232C GP-IB
PW3335 Yes Yes No
PW3335-01 Yes No Yes
PW3335-02 Yes Yes No
PW3335-03 Yes Yes No

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Instruction manual ×1
  • Power cord ×1
  • Voltage and current input terminal safety cover ×2

Product Core & Specifications

Specification Value
Input Specifications
Measurement line type Single-phase 2-wire (1P2W)
Voltage input method Isolated input, resistive voltage divider method
Current input method Isolated input, shunt input method
Voltage measurement ranges AUTO / 6.0000 V / 15.000 V / 30.000 V / 60.000 V / 150.00 V / 300.00 V / 600.00 V / 1.0000 kV
Current measurement ranges AUTO / 1.0000 mA / 2.0000 mA / 5.0000 mA / 10.000 mA / 20.000 mA / 50.000 mA / 100.00 mA / 200.00 mA / 500.00 mA / 1.0000 A / 2.0000 A / 5.0000 A / 10.000 A / 20.000 A
Power ranges Depends on combination of voltage and current ranges; from 6.0000 mW to 20.000 kW (also applies to VA, var)
Voltage input resistance Approx. 2 MΩ
Current input resistance 1 mA to 100 mA range: 520 mΩ or less; 200 mA to 20 A range: 15 mΩ or less
Basic Measurement Specifications
Measurement method Simultaneous voltage and current digital sampling, zero-cross simultaneous calculation
Sampling frequency Approx. 700 kHz
A/D converter resolution 16-bit
Frequency bandwidth DC, 0.1 Hz to 100 kHz (values within 0.1 Hz ≤ f < 10 Hz are for reference only)
Synchronization sources U, I, DC (fixed to 200 ms)
Basic accuracy (DC) Voltage / current / power: ±0.1% rdg, ±0.1% f.s.
Basic accuracy (45 Hz to 66 Hz) Voltage / current / power: ±0.1% rdg, ±0.05% f.s.
Effect of power factor ±0.1% f.s. (45 to 66 Hz, at power factor = 0)
Effect of common mode voltage ±0.01% f.s. or less (600 V, 50/60 Hz)
Maximum effective peak voltage ±600% of each voltage range; for 300 V, 600 V, and 1000 V ranges, ±1500 V peak
Maximum effective peak current ±600% of each current range; for 20 A range, ±60 A peak
Guaranteed accuracy period 1 year
Temperature coefficient ±0.03% f.s. per °C or less (±0.06% f.s. per °C for 1 mA range)
Harmonic Measurement
Measurement method Zero-cross simultaneous calculation; IEC 61000-4-7:2002 compliant when synchronization frequency is 45 Hz to 66 Hz
FFT processing 32-bit word length, 4096 points
Window function Rectangular
Maximum analysis order Up to 50th
Analysis order upper limit setting 2nd to 50th
Frequency Measurement
Number of channels 2 (voltage, current)
Measurement ranges 100 Hz / 500 Hz / 5 kHz / 100 kHz (linked to zero-cross filter)
Measurement accuracy ±0.1% rdg ±1 dgt (±0.2% rdg ±1 dgt for 1 mA range)
Effective measuring range 0.1 Hz to 100 kHz
Integration
Integration time 1 min. to 10000 hr., settable in 1 min. blocks
Integration time accuracy ±0.01% rdg ±1 dgt
Display resolution 999999 (6 digits + decimal point)
Display
Display type 7-segment LED
Number of display parameters 4 (display area a, b, c, and d)
Display resolution 99999 count (5 digits); integrated values 999999 count (6 digits)
Display update rate 200 ms ±50 ms (approx. 5 updates/sec) to 20 s
Synchronized Control
Terminal BNC terminal × 1 (non-isolated)
Number of units Up to 7 slaves per master (total of 8 units including PW3336/PW3337 series)
LAN Interface (all models)
Connector RJ-45 × 1
Electrical specifications Compliant with IEEE802.3
Transmission method 10Base-T / 100Base-TX (automatic detection)
Protocol TCP/IP
RS-232C Interface (PW3335, PW3335-02, PW3335-03, PW3335-04)
Connector D-sub 9-pin × 1
Communication method Full duplex, start-stop synchronization; 1 stop bit (fixed); 8 data bits (fixed); no parity
Communication speed 9600 bps / 38400 bps
GP-IB Interface (PW3335-01, PW3335-04)
Method Compliant with IEEE488.1 1987, referenced to IEEE488.2 1987
Address 00 to 30
D/A Output (PW3335-02, PW3335-04)
Number of output channels 7 channels
Configuration 16-bit D/A converter (polarity + 15 bits)
Maximum output voltage Approx. ±12 V DC
Output resistance Approx. 100 Ω
External Current Sensor Input (PW3335-03, PW3335-04)
Terminal Isolated BNC terminals
Current sensor type switching Off / TYPE.1 / TYPE.2
Current measurement range Auto / 1 A / 2 A / 5 A
Power range configuration From 24.000 W to 5.0000 MW (also applies to VA, var)
General Specifications
Product warranty period 1 year
Operating environment Indoors, altitude up to 2000 m (6562 ft), pollution degree 2
Operating temperature and humidity 0°C to 40°C (32°F to 104°F), 80% RH or less (no condensation)
Storage temperature and humidity -10°C to 50°C (14°F to 122°F), 80% RH or less (no condensation)
Dielectric strength 4290 V rms AC (current sensitivity: 1 mA)
Important: Measurement Category III 600 V; Measurement Category II 1000 V. Maximum input between voltage input terminals U and ±: 1000 V, ±1500 V peak. Maximum input between current input terminals on the 200 mA to 20 A range: 30 A, ±100 A peak.Important: Type 2 current sensor options (9272-10, CT6841, CT6843, 9279, CT6862, CT6863, 9709, CT6865) require Sensor Unit 9555-10 and Connection Cable L9217, sold separately.Important: External current sensor input is available only on PW3335-03 and PW3335-04. D/A output is available only on PW3335-02 and PW3335-04. GP-IB is available only on PW3335-01 and PW3335-04. RS-232C is available on PW3335, PW3335-02, PW3335-03, and PW3335-04 (not PW3335-01).Important: Two or more PW3335 units are necessary in order to carry out efficiency computation.Important: For voltage and current D/A high-speed level output, cycle-by-cycle updating is possible only with an input of 45 to 66 Hz.Important: Harmonic voltage phase angle, harmonic current phase angle, and harmonic voltage/current phase difference can be acquired only via PC communication.Recommended pairing: for current measurement above the 30 A direct-input limit, the PW3335-03 or PW3335-04 accepts Hioki external current sensors via the dedicated input. Type 1 sensors (9660, 9661, 9669, CT9667) connect directly; Type 2 sensors (9272-10, CT6841, CT6843, 9277, 9278, 9279, 9709, CT6862, CT6863, CT6865) require Sensor Unit 9555-10 and Connection Cable L9217 as named in the datasheet.