Skip to content

The Preen PFV-33100 is a programmable AC power supply, with four quadrant energy feedback function. The Preen PFV-33100 not only provides power to the EUT, but also sinks the power back to the grid system, which the data sheet calls very useful for grid-tied devices testing applications. Efficiency is ≥ 92% at maximum power.
Programmable functions on the Preen PFV-33100 simulate power line disturbances such as voltage or frequency ramp up or ramp down, transient and step changes. Three-phase independent adjustment and phase angle setting are listed for the Preen PFV-33100; voltage ride through (VRT) is listed as NO for the PFV Series, so LVRT and HVRT testing belongs to the PAS-F Series.
Two output ranges let the Preen PFV-33100 trade voltage for current. The low range, 0V-150.0V(L-N), delivers a maximum of 277.8A (RMS), and the high range, 0V-300.0V(L-N), delivers a maximum of 138.9A (RMS); the rating is 100kVA.
| Parameter | Value | Conditions |
|---|---|---|
| Output power (VA) | 100kVA | — |
| Maximum output current (RMS), PFV Series low range (0V-150.0V) | 277.8A | — |
| Maximum output current (RMS), PFV Series high range (0V-300.0V) | 138.9A | — |
| Output phase | 3Ø / 4 Wire + G | — |
| Output voltage range, PFV Series low range | 0V-150.0V(L-N) | — |
| Output voltage range, PFV Series high range | 0V-300.0V(L-N) | — |
| Output voltage resolution | 0.1V | — |
| Output voltage accuracy | 0.5% F.S.+4 counts | — |
| Output frequency range, standard | 45-65Hz | — |
| Output frequency range, option | 40-70Hz | listed as an option in the specification table; the PFV ordering list names no option code for it |
| Output frequency resolution | 0.1Hz | — |
| Output frequency accuracy | ±0.02% F.S | — |
| Line regulation | ≤ 1% | — |
| Load regulation | ≤ 1% | Resistive Load |
| Response time | ≤ 2ms | the data sheet does not state the conditions of this figure |
| Total harmonic distortion (THD) | ≤ 2% | Resistive Load |
| Crest factor | ≥ 3 | — |
| Parameter | Value |
|---|---|
| Voltage measurement range | 0V-300.0V |
| Voltage measurement resolution | 0.1V |
| Voltage measurement accuracy | 0.5%F.S.+4counts |
| Frequency measurement range | Standard : 45-65Hz Option : 40-70Hz |
| Frequency measurement resolution | 0.01Hz |
| Frequency measurement accuracy | ±0.02% F.S |
| Current measurement range (RMS) | 0-9999A |
| Current measurement resolution (RMS) | 0.1A |
| Current measurement accuracy (RMS) | 0.5% F.S.+4counts |
| Power measurement range | 0-1000kW |
| Power measurement resolution | 0.1kW |
| Power measurement accuracy | 1% F.S.+6 counts |
| Parameter | Value | Conditions |
|---|---|---|
| Regenerative function | YES | — |
| Voltage ride through (VRT) | NO | PFV Series |
| Three-phase independent adjustment | YES | — |
| Phase angle setting | YES | — |
| Efficiency | ≥ 92% | at Max. Power |
| Operator interface (HMI) | Touch Screen | — |
| Input protection | Input N.F.B, Over Voltage, Under Voltage | — |
| Output protection | Over Voltage, Over Current, Reverse Current, Over Temperature | — |
| Remote interfaces, standard | RS-485, RS-232 | — |
| Remote interfaces, optional | GPIB, Ethernet, USB | — |
| Model | Output power (VA) | Maximum output current (RMS), PFV Series high range (0V-300.0V) | Maximum input current | Weight |
|---|---|---|---|---|
| PFV-33030 | 30kVA | 41.6A | 58.7A | 942kg |
| PFV-33045 | 45kVA | 62.5A | 88.1A | 1050kg |
| PFV-33060 | 60kVA | 83.3A | 117.4A | 1185kg |
| PFV-33075 | 75kVA | 104.1A | 146.8A | 1485kg |
| PFV-33100 (this page) | 100kVA | 138.9A | 195.7A | 1919kg |
| PFV-33120 | 120kVA | 166.6A | 234.9A | 2300kg |
| PFV-33150 | 150kVA | 208.3A | 293.6A | 2700kg |
| PFV-33200 | 200kVA | 277.8A | 391.4A | 3400kg |
| PFV-33300 | 300kVA | 416.7A | 587.1A | 4500kg |
| PFV-33400 | 400kVA | 555.6A | 782.8A | 5600kg |
The Preen PFV-33100 is rated 100kVA, with a maximum output current of 277.8A (RMS) on the low range and 138.9A (RMS) on the high range, and a crest factor of ≥ 3. Pick the range that holds your EUT voltage, then check its RMS and peak current against that range.
The Preen PFV-33100 output is 3Ø / 4 Wire + G, with voltage ranges of 0V-150.0V(L-N) and 0V-300.0V(L-N) and a standard frequency range of 45-65Hz (40-70Hz is listed as an option in the specification table). Output voltage accuracy is 0.5% F.S.+4 counts, total harmonic distortion ≤ 2%, and line and load regulation ≤ 1% and ≤ 1% with a resistive load.
The Preen PFV-33100 input is 3Ø / 3 Wire + G, 380V±15% at 47-63Hz, with a maximum input current of 195.7A (based on a rated input voltage of 380V minus 15%) and a power factor of ≥ 0.99 at maximum power. The catalog refers other input voltages to the manufacturer.
The Preen PFV-33100 measures 2200 x 1600 x 800 mm / 86.61 x 62.99 x 31.49 inch (H x W x D) and weighs 1919kg; the catalog notes that the weight of certain models is estimated. Operating temperature is 0℃~45℃, humidity 0-90% non condensing, at an altitude below 1,500m.
The Preen PFV-33100 has a Touch Screen operator interface. RS-485 and RS-232 remote interfaces are standard, and GPIB, Ethernet and USB are options. Input protection covers Input N.F.B, Over Voltage, Under Voltage; output protection covers Over Voltage, Over Current, Reverse Current, Over Temperature.
The soft start, interface and other ordering options for the Preen PFV-33100 are listed on the Options tab.
| Parameter | Value | Conditions |
|---|---|---|
| Maximum input current | 195.7A | based on a rated input voltage of 380V minus 15% (footnote *2) |
| Input phase | 3Ø / 3 Wire + G | — |
| Input voltage | 380V±15% | the data sheet refers other input voltage specifications to the manufacturer (footnote *1) |
| Input frequency | 47-63Hz | — |
| Input power factor | ≥ 0.99 | Max. Power |
| Parameter | Value | Conditions |
|---|---|---|
| Weight | 1919kg | The weight of certain models is estimated (footnote *4) |
| Weight (lbs) | 4230.7 lbs | The weight of certain models is estimated (footnote *4) |
| Operating temperature | 0℃~45℃ | — |
| Humidity | 0-90% | Non condensing |
| Altitude | < 1,500m | — |
| Dimensions (H x W x D) | 2200 x 1600 x 800 mm / 86.61 x 62.99 x 31.49 inch | H x W x D; the data sheet refers detailed dimensions to the manufacturer (footnote *3) |
| Parameter | Value |
|---|---|
| Gradual and step functions | voltage or frequency ramp up or ramp down, transient and step changes |
| Product type | programmable AC power supply, with four quadrant energy feedback function |
| Energy feedback | not only provides power to the EUT, but also sinks the power back to the grid system |
| Applications | grid-tied devices testing applications |
| Parameter | Value |
|---|---|
| Ordering description | 100kVA/300V/45-65Hz, Including Regenerative Function |
The Preen PFV-33100 is a PFV Series high power programmable AC power source rated 100kVA with three-phase output and regenerative function, a programmable AC power supply, with four quadrant energy feedback function.
The Preen PFV-33100 supplies three-phase AC to an EUT and sinks the power back to the grid, which the data sheet calls very useful for grid-tied devices testing applications.
The Preen PFV-33100 has two output voltage ranges, 0V-150.0V(L-N) and 0V-300.0V(L-N), set with a resolution of 0.1V and an accuracy of 0.5% F.S.+4 counts.
The Preen PFV-33100 output frequency range is 45-65Hz as standard, with a resolution of 0.1Hz and an accuracy of ±0.02% F.S. The specification table lists 40-70Hz as an option; the PFV ordering list does not name a frequency option code.
The Preen PFV-33100 output power is 100kVA, with a maximum output current of 277.8A (RMS) on the low range and 138.9A (RMS) on the high range.
The Preen PFV-33100 has a three-phase output, 3Ø / 4 Wire + G, with three-phase independent adjustment and phase angle setting.
The Preen PFV-33100 is regenerative (the data sheet lists the regenerative function as YES), and its efficiency is ≥ 92% at maximum power.
The PFV Series ordering list for the Preen PFV-33100 has soft start and interface options only (PFV-001 to PFV-004); the harmonics editor is listed as a PAS series option, and voltage ride through is not listed for the PFV Series. Gradual and step functions program voltage or frequency ramp up or ramp down, transient and step changes.
The Preen PFV-33100 measures voltage over 0V-300.0V with an accuracy of 0.5%F.S.+4counts, current over 0-9999A (RMS) with an accuracy of 0.5% F.S.+4counts, and power over 0-1000kW with an accuracy of 1% F.S.+6 counts.
The Preen PFV-33100 produces three-phase AC at a set voltage and frequency and programs line disturbances such as ramps and steps; a DC power supply produces a DC output. The Preen PFV-33100 also sinks power from the EUT back to the grid.
The Preen PFV-33100 adds a low output range (0V-150.0V(L-N)) to the 0V-300.0V(L-N) range, while voltage ride through is listed as NO for the PFV Series and the harmonics editor as a PAS series option. The compare table on this page lists every PFV model.
Specifications are from the manufacturer's technical document (Preen PAS/PFV Series Regenerative Grid Simulator (catalog pages 52-57), PAS/PFV catalog section (catalog p.52-57), no date printed). Questions? Contact your Test Architect.
Updated 2026-11-26
Every used unit is fully tested in our lab, and its performance is guaranteed to pass an optional calibration.
Model No
PFV-33100
Condition
Used
Manufacturer
Preen
Frequency
65 Hz
Phase
3
Power (va)
100 kVA
Volts
300 V
PFV-001
Soft Start Function.
PFV-002
GPIB Interface.
PFV-003
Ethernet Interface.
PFV-004
USB Interface.