Skip to product information
1 of 4

Keysight N9937D 18 GHz FieldFox Handheld Spectrum Analyzer

Keysight N9937D 18 GHz FieldFox Handheld Spectrum Analyzer

Regular price $39,287
Sale price $39,287 Regular price $0
Shipping calculated at checkout.
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

🎓 Request a Quote To Get An EDU Discount

Key Features At A Glance

The Keysight N9937D is a FieldFox D-Series handheld signal analyzer (spectrum analyzer) covering 9 kHz to 18 GHz.

  • Test port connector: Type-N (f)
  • Battery: Field swappable battery
  • Display and keys: Bright, low-reflection display and backlit keys enable easy viewing in direct sunlight or darkness
  • Operating system: Linux operating system
View full details

What the Keysight N9937D is and what it is used for

The Keysight N9937D is a battery-powered FieldFox signal analyzer. Its basic spectrum analysis includes channel power, occupied bandwidth, adjacent channel power and spectrum emission mask measurements, AM/FM tune and listen, field strength measurements and a frequency counter marker. The full-band tracking generator (Option 220), the preamplifier (Option 235) and real-time spectrum analysis (Option 350) are options, and Keysight states that they can be added as a software upgrade later.

Keysight N9937D key specifications

Model overview

Keysight N9937D: Model overview (data sheet 3126-1012.EN p.39, 54, 57, 100)
Parameter Value Conditions
Frequency range (spectrum analyzer) 9 kHz to 18 GHz usable to 5 kHz; the spectrum analyzer is tunable to 0 Hz or DC
Tracking generator or independent source frequency range 30 kHz to 18 GHz —
Test port connector Type-N (f) —
Test port input impedance 50 Ω —
Maximum real-time bandwidth (Option 350 RTSA) 10 MHz (standard); 40 MHz (Option B04); 100/120 MHz (Option B10) —
Min. signal duration, 100% POI, 10 MHz 9.13 us —
Min. signal duration, 100% POI, 40 MHz 6.13 us —
Min. signal duration, 100% POI, Option B10 5.52 us —

Spectrum analyzer DANL (dBm)

Keysight N9937D: Spectrum analyzer DANL (dBm)
Frequency Preamp off, spec (23 ±5 °C) Preamp off, typical (23 ±5 °C) Preamp off, typical (-10 to 55 °C) Preamp on, spec (23 ±5 °C) Preamp on, typical (23 ±5 °C) Preamp on, typical (-10 to 55 °C)
9 kHz to 2 MHz -118 -136 -133 -125 -150 -146
> 2 MHz to 2.1 GHz -139 -148 -146 -156 -164 -162
> 2.1 to 2.6 GHz -140 -146 -143 -155 -160 -159
> 2.6 to 4.5 GHz -142 -148 -145 -156 -163 -160
> 4.5 to 7.5 GHz -138 -146 -143 -153 -160 -158
> 7.5 to 13 GHz -139 -145 -142 -157 -162 -160
> 13 to 18 GHz -135 -142 -139 -153 -159 -158

Input terminated, RMS detection, log averaging, 0 dB input attenuation, reference level of -20 dBm, normalized to 1 Hz RBW, measured at non-zero frequency span. The preamplifier is Option 235.

Spectrum analyzer TOI (dBm)

Keysight N9937D: Spectrum analyzer TOI (dBm)
Frequency Typical (23 ±5 °C) Typical (-10 to 55 °C)
50 MHz to 500 MHz +9 +6.5
≥ 500 MHz to 2 GHz +11 +5
≥ 2 to 2.4 GHz +14 +5
≥ 2.4 to 2.5 GHz +14 +9.5
≥ 2.5 to 7.5 GHz +11 +9.5
≥ 7.5 to 10 GHz +11 +7.5
≥ 10 to 20 GHz +13 +10

Two -15 dBm signals, 100 kHz spacing: at the mixer input (N991x and N993x models, and the N995xD and N996xD), or with a reference level of -10 dBm (N995xB and N996xB, nominal). For the N995x and N996x models, bands above 23 GHz are tested with 2 MHz tone spacing.

Spectrum analyzer amplitude accuracy, preamp off (dB)

Keysight N9937D: Spectrum analyzer amplitude accuracy, preamp off (dB)
Frequency Spec (23 ±5 °C) Typical (23 ±5 °C) Typical (-10 to 55 °C)
9 to 100 kHz ±1.70 ±0.25 ±0.75
> 0.1 to 50 MHz ±0.70 ±0.10 ±0.20
> 50 to 500 MHz ±0.70 ±0.15 ±0.30
> 0.5 to 16.3 GHz ±0.90 ±0.25 ±0.45
> 16.3 to 18 GHz ±0.80 ±0.20 ±0.35

10 dB attenuation, input signal -15 to -5 dBm, peak detector, 300 Hz RBW, all settings auto-coupled, includes frequency response uncertainties; no warm-up required.

Spectrum analyzer SSB phase noise at 1 GHz (dBc/Hz)

Keysight N9937D: Spectrum analyzer SSB phase noise at 1 GHz (dBc/Hz) (data sheet 3126-1012.EN p.51)
Parameter Value
Offset 10 kHz, spec (23 ±5 °C) -107
Offset 10 kHz, typical (23 ±5 °C) -112
Offset 10 kHz, typical (-10 to 55 °C) -111
Offset 30 kHz, spec (23 ±5 °C) -110
Offset 30 kHz, typical (23 ±5 °C) -113
Offset 30 kHz, typical (-10 to 55 °C) -113
Offset 100 kHz, spec (23 ±5 °C) -106
Offset 100 kHz, typical (23 ±5 °C) -110
Offset 100 kHz, typical (-10 to 55 °C) -110
Offset 1 MHz, spec (23 ±5 °C) -121
Offset 1 MHz, typical (23 ±5 °C) -125
Offset 1 MHz, typical (-10 to 55 °C) -124
Offset 3 MHz, spec (23 ±5 °C) -126
Offset 3 MHz, typical (23 ±5 °C) -130
Offset 3 MHz, typical (-10 to 55 °C) -128
Offset 5 MHz, spec (23 ±5 °C) -124
Offset 5 MHz, typical (23 ±5 °C) -129
Offset 5 MHz, typical (-10 to 55 °C) -128

The 3 MHz offset is tested at 2.99 MHz (and in the D-Series data sheet the 5 MHz offset at 4.99 MHz).

Spectrum analyzer settings and ranges

Keysight N9937D: Spectrum analyzer settings and ranges (data sheet 3126-1012.EN p.40, 41, 42, 46, 48, 59; technical document 5992-3703EN p.22)
Parameter Value Conditions
Resolution bandwidth (-3 dB), non-zero span 1 Hz to 5 MHz —
Resolution bandwidth (-3 dB), zero span 10 Hz to 5 MHz —
Video bandwidth (VBW) 1 Hz to 5 MHz —
Measurement range DANL to +20 dBm —
Input attenuator range 0 to 40 dB, in 5 dB steps —
Preamplifier gain (Option 235) +15 dB, 9 kHz to 7.5 GHz; +20 dB, ≥ 7.5 to 26.5 GHz group row; full band (9 kHz to maximum frequency of instrument)
Spur free dynamic range, 2.4 GHz (dB) > 106 —
Sweep (trace) points 101, 201, 401, 601, 801, 1001 (defaults to 401) arbitrary 2 to 20,001 settable through soft key or SCPI
Sweep time, zero span (range) 1 μs to 6000 s —
50 MHz absolute amplitude accuracy (dB) ±0.50; ±0.10; ±0.20 spec (23 ±5 °C); typical (23 ±5 °C); typical (-10 to 55 °C); 10 dB attenuation, input signal -40 to -5 dBm, peak detector, preamplifier off, 300 Hz RBW
Input related responses (dBc), -30 dBm signal at mixer input -80 excludes the frequencies listed in the data sheet table, p.46
I/Q streaming (requires option 353) Maximum BW of 120 MHz with Option B10 over the SFP+ or Ethernet port in either VITA 49A or Decodio formats
I/Q streaming (Option 353), data gapless IQ data to external application software —

Compare the Keysight N9937D with other models

Keysight N9937D: compare FieldFox microwave signal analyzers (data sheet 3126-1012.EN p.39, 100)
Model Frequency range (spectrum analyzer) Test port connector
N9936D 9 kHz to 14 GHz Type-N (f)
N9937D (this page) 9 kHz to 18 GHz Type-N (f)
N9938D 9 kHz to 26.5 GHz 3.5 mm (m) by ordering option N9938D-100 or Type-N (f) by default
N9960D 9 kHz to 32 GHz NMD 2.4 mm (m)
N9961D 9 kHz to 44 GHz NMD 2.4 mm (m)
N9962D 9 kHz to 50 GHz NMD 2.4 mm (m)
N9963D 9 kHz to 54 GHz NMD 1.85 mm (m)

What decides whether the Keysight N9937D fits

Frequency: does the Keysight N9937D cover your bands?

The Keysight N9937D spectrum analyzer covers 9 kHz to 18 GHz (usable to 5 kHz; the spectrum analyzer is tunable to 0 Hz or DC). With the full-band tracking generator (Option 220) the source covers 30 kHz to 18 GHz, for filter and cable sweeps.

Test ports: which connector does the Keysight N9937D use?

The Keysight N9937D test port connector is Type-N (f), with an input impedance of 50 Ω. Calibration kits, cables and adapters must match that connector and the frequency range; the configuration guide lists Keysight mechanical calibration kits and USB ECal modules by connector type.

Weak signals: how low is the Keysight N9937D noise floor?

The Keysight N9937D displayed average noise level in the > 2 MHz to 2.1 GHz band is -156 dBm (spec at 23 ±5 °C, preamplifier on) and -139 dBm (spec at 23 ±5 °C, preamplifier off). The preamplifier is Option 235.

Real-time analysis: will the Keysight N9937D catch short signals?

The Keysight N9937D maximum real-time bandwidth with real-time spectrum analysis (Option 350) is 10 MHz (standard); 40 MHz (Option B04); 100/120 MHz (Option B10). The minimum signal duration with 100% probability of intercept at full amplitude accuracy is 9.13 us at the standard real-time bandwidth and 5.52 us with Option B10.

Licensed features: what is installed on the Keysight N9937D?

On the Keysight N9937D the measurement capabilities are license-key options, so confirm the options installed on a particular unit before relying on them.

Rules of thumb (not specifications)

Noise floor and resolution bandwidth. Displayed noise changes by 10·log10 of the resolution-bandwidth ratio: 10× narrower lowers it by 10 dB. A noise floor normalized to 1 Hz must be scaled to the bandwidth in use before comparing with a signal level. Rule of thumb, not a specification.

Example with the Keysight N9937D: The Keysight N9937D noise floor of -139 dBm in the > 2 MHz to 2.1 GHz band is normalized to 1 Hz; measured with a 10× wider RBW, the displayed noise is about 10 dB higher by this rule.

Keysight N9937D options and what they change

The measurement options and accessories that the configuration guide lists for the Keysight N9937D are on the Options tab.

Other Keysight N9937D specifications

General, power and interfaces

Keysight N9937D: General, power and interfaces (data sheet 3126-1012.EN p.94, 98, 99, 100, 101)
Parameter Value Conditions
Dimensions (H x W x D) 292 x 188 x 82 mm (11.5 x 7.4 x 3.2 in) (approx.) —
Ingress protection IP53 type tested; IP rating for the instrument by itself, with no cover
Operating temperature, AC power -10 to 55 °C (14 to 131 °F) -10 to 45 °C/14 to 113 °F in RTSA mode
Operating temperature, battery -10 to 50 °C (14 to 122 °F) —
Storage temperature -51 to 71 °C (-60 to 160 °F) —
External DC input 15 VDC, 4 amps maximum —
External AC power adapter input 100 to 240 VAC, 50 to 60 Hz, 1.5 to 0.75 A —
Power consumption 16 to 30 watts (typical), 60 watts maximum —
Battery (lithium ion) 10.95 V, 7.0 A-h, 77 Wh —
Battery charge time about 1.5 hours to recharge to 80%. Four hours to 100% —
Display 6.5” transflective color LCD-LED backlit; touchscreen for file management —
SFP+, 2 ports Compact, hot-pluggable sockets compatible with 10-GbE (Gigabit Ethernet) —
USB-A, 1 port High-speed USB 3.0, for data transfer and SCPI programming —
USB-C, 1 port High-speed USB 3.0/DP out, for data transfer, SCPI programming, and USB earphone plug-in —
LAN (RJ-45) 1000/100/10 base-T (auto switching) used for programming, data saving, remote control, and DataLink software
Internal data storage Internal Minimum: 4 GB —
External data storage Supports USB 3.0 compatible memory devices and SD/SDHC memory cards —
Built-in GNSS (GPS+) receiver (Option 307), supported systems GPS, GLONASS, BeiDou and Galileo requires external GNSS/GPS antenna (can use N9910X-825, GPS active antenna)
DC bias variable-voltage source (Option 309), voltage +2.5 to +32 V (nominal) SMB (m) connector
DC bias variable-voltage source (Option 309), maximum current 2 A (nominal) above 3.5 V the current is limited by the 7 W maximum power
DC bias variable-voltage source (Option 309), maximum power 7 watts (nominal) —

Tracking generator output power, high (dBm)

Keysight N9937D: Tracking generator output power, high (dBm)
Frequency Typical
30 kHz to 500 kHz -6
> 500 kHz to 10 MHz 0
> 10 MHz to 1 GHz 9
> 1 to 5 GHz 8
> 5 to 10 GHz 8
> 10 to 18 GHz 6

Typical. The full-band tracking generator is Option 220.

Further data sheet tables

Keysight N9937D: Further data sheet tables
Specification Where in the data sheet
Total absolute amplitude accuracy with preamp on Data sheet p.43, Total absolute amplitude accuracy (dB) with preamp on
I/Q analyzer (Option 351) Data sheet p.58, I/Q Analyzer (IQA) (Option 351)

Keysight N9937D questions and answers

Which options change what the Keysight N9937D measures?

The Keysight N9937D measures spectrum as standard. Option 220 adds the full-band tracking generator, Option 235 the preamplifier, Option 350 real-time spectrum analysis, Option 351 the I/Q analyzer and Options B04 and B10 analysis bandwidths of 40 MHz and 120 MHz; the Options tab lists the rest.

What is the maximum input level of the Keysight N9937D?

The maximum safe input level of the Keysight N9937D is unknown — not confirmed in approved data. The D-Series data sheet's maximum safe input table names the N993xD models in two rows with different limits, so confirm the limit with Keysight before connecting a high-level source.

What else is needed to use the Keysight N9937D?

The Keysight N9937D needs cables and adapters rated for its test port connector and frequency range. The GPS receiver (Option 307) needs a GPS antenna such as the N9910X-825, USB power sensor measurements (Option 302) need a Keysight USB power sensor, and noise figure (Option 356) needs Options 235 and 309 and an external noise source.

How is a spectrum analyzer different from a vector network analyzer?

The Keysight N9937D is a spectrum analyzer, so it measures signals that already exist, such as transmitters and interference. A vector network analyzer injects its own test signal into a component and measures its S-parameters; the FieldFox D-Series combination analyzers do both.

Specifications are from the manufacturer's data sheet (FieldFox D-Series Handheld Analyzers 14/18/26.5/32/44/50/54 GHz Data Sheet, 3126-1012.EN, June 24, 2026) and configuration guide (FieldFox Handheld Analyzers 14/18/26.5/32/44/50/54 GHz (D Series) Configuration Guide, 3125-1447.EN, April 6, 2026) and technical document (FieldFox Handheld Analyzers 4/6.5/9,10/14/18/26.5/32/44/50/54 GHz Technical Overview, 5992-3703EN, December 4, 2025). Questions? Contact your Test Architect.

Updated 2026-11-26

Model No

Keysight

Condition

Factory New

Manufacturer

Keysight

Spec_ana_freq

18 GHz

Please note

This list holds at most 128 lines, so long tables are shown as one line each, exactly as printed. The manufacturer's documents are the source of truth; our records hold 193 orderable items for this model from them.

209

Extended Range Transmission Analysis (ERTA). Requires 220. Recommend 307. Requires two FieldFox units.

220

Full-band tracking generator. CW, CW coupled, and tracking.

235

Pre-amplifier.

236

Interference analyzer and spectrogram.

238

Spectrum analyzer time gating.

312

Channel scanner. Require the corresponding option to support a specific app. For example, to support EMF in channel scanner requires 358; to support indoor and outdoor mapping requires 352.

350

Real-Time Spectrum Analyzer (RTSA). Recommend 235.

351

I/Q Analyzer (IQA).

352

Indoor and outdoor mapping. Requires 307, and at least one of 312, 360, 370, 371, or 378.

353

IQ streaming. Requires 351.

355

Analog demodulation.

356

Noise Figure (NF). Requires 235, 309 and accessory item N9910X-713 BNC to SMB cable.

357

Pulse generator.

358

EMF measurements. Requires triaxial isotropic antenna.

361

EMI measurements.

366

Interference finder (manual mode). Requires 307, and 85574A Handheld direction antenna.

370/371

Over-the-Air (OTA) LTE FDD/TDD. Requires 307, recommend 235.

378

Over-the-Air (OTA) 5G NR. Requires B10 and 307. Recommend 235. For NR2, no external mixer required for N996xD.

390

Directional finding - TDOA node support.

391

Directional finding - Angle of Arrival (AoA).

B04

Analysis bandwidth, 40 MHz. Recommend 350, 351 or PathWave VSA (formerly 89600 VSA) software.

B10

Analysis bandwidth, 120 MHz. Recommend 350, 351, 378 or PathWave VSA (formerly 89600 VSA) software.

208

USB power sensor meas. versus frequency. Requires 302.

302

USB power sensor support. Need to order USB power sensor.

310

Built-in power meter. No power sensor required.

330

Pulse meas. with USB peak power sensor. Requires 302 and USB peak power sensor.

030

Remote control capability. Requires an iOS device or an Android device.

307

GPS receiver. Need to order GPS antenna, N9910X-825.

309

DC Power Supply (DCPS). Recommend N9910X-713 cable.

89601C

PathWave VSA (89600 VSA) software.

N6820ES

Surveyor 4D software. Requires 235 and 307.

SJ002A

WaveJudge Wireless Analyzer Toolset.

S9910A

Keysight spectrum management software (KSMS). Requires 235 and 307.

S9911A

Directional Finding - TDOA. Requires S9910A.

S9912A

Directional Finding - AoA. Requires S9910A.

N9910X-874

External bias-tee, 2.5 MHz to 6 GHz, 1 W, 0.5 A. Also recommend ordering N9910X-713 Bias-Tee Power Cable, SMB(f) to BNC(m), 3.28 ft., to connect to the FieldFox DC source.

Other FieldFox Accessories

N9910X-876 Extra high-capacity battery; N9910X-880 Extra soft carrying case with backpack and shoulder strap; N9910X-872 External battery charger; N9910X-873 AC/DC adapter; N9910X-881 Hard transit case; N9910X-875 DC car charger and adapter.

Other RF and Microwave Accessories

N9910X-712 Trig/Ref in Cable SMA (m) to BNC (f), 1 m or 3.28 ft; N9910X-713 Bias-tee power cable SMB (f) to BNC (m), 1 m or 3.28 ft; N9910X-860 Fixed attenuator, 40 dB, 100 W, DC to 3 GHz, Type-N (m) to Type-N (f); N9910X-861 Fixed attenuator, 40 dB, 50 W, DC to 8.5 GHz, Type-N (m) to Type-N (f); N9910X-895 Magnetic mount base for antenna.

Antennas

N9910X-825 Antenna, GPS, active, SMA (m); N9910X-820 Antenna, directional, multiband, 800 to 2500 MHz, 10 dBi, Type-N (f); N9910X-821 Antenna, telescopic whip, 70 MHz to 1 GHz, BNC (m); N9910X-822 Antenna, directional, log periodic, 600 MHz to 9 GHz, Type-N (f); N9910XA-823 Antenna, cellular narrowband, 824 to 869 MHz, Type-N (f); N9910XA-824 Antenna, cellular narrowband, PCS 1850 to 1990 MHz, Type-N (f); 85572A EMF Triaxial antenna; 85572A-006 Triaxial Isotropic Antenna 400 MHz to 6 GHz; 85572A-007 Triaxial Isotropic Antenna 30 MHz to 6 GHz; 85573A Automatic DF Antenna and accessories; 85573A-108 20 MHz to 8 GHz DF AoA antenna (including cable assembly); 85574A Handheld direction antenna and accessories; 85574A-100 20 MHz to 8.5GHz direction antenna with digital compass; 85574A-209 Frequency extension for 85574A option 100 - 9 kHz to 20 MHz.

Cables

N9910X-700 Type-N (m) Type-N (f) 18 GHz 3.28 ft 1 m; N9910X-701 Type-N (m) Type-N (m) 18 GHz 3.28 ft 1 m; N9910X-704 Type-N (m) TNC (f) 13 GHz 5 ft 1.5 m; N9910X-705 Type-N (m) TNC (m) 13 GHz 5 ft 1.5 m; N9910X-716 Type-N (m) Type-N (m) 18 GHz 2 ft 0.61 m; N9910X-810 Type-N (m) Type-N (m) 8 GHz 5 ft 1.5 m; N9910X-811 Type-N (m) Type-N (f) 8 GHz 5 ft 1.5 m; N9910X-812 Type-N (m) Type-N (m) 8 GHz 12 ft 3.6 m; N9910X-813 Type-N (m) Type-N (f) 8 GHz 12 ft 3.6 m; N9910X-814 Type-N (m) 7/16 (m) 6 GHz 5 ft 1.5 m; N9910X-815 Type-N (m) 7/16 (m) 6 GHz 12 ft 3.6 m; N9910X-816 Type-N (m) Type-N (f) 6 GHz 3.28 ft 1 m; N9910X-817 Type-N (m) Type-N (m) 6 GHz 3.28 ft 1 m.

RF and Microwave Adapters

N9910X-843 Coaxial adapter, Type-N (m) to 7/16 DIN (f); N9910X-845 Adapter kit: Type-N (f) to 7/16 DIN (f), Type-N (f) to 7/16 DIN (m), Type-N (f) to Type-N (f); N9910X-846 Coaxial adapter, Type-N (m) 50 ohm to Type-N (f) 75 ohm; N9910X-847 Adapter kit: Type-N (f) to TNC (m) adapter, Type-N (f) to TNC (f) adapter, 10 GHz; N9910X-848 Coaxial adapter, Type-N (f) to 3.5 mm (f), 18 GHz; N9910X-849 Coaxial adapter, Type-N (f) to 3.5 mm (m), 18 GHz; N9910X-850 Coaxial adapter, Type-N (m) to Type-N (m), 18 GHz; N9910X-851 Coaxial adapter, Type-N (f) to Type-N (f), 18 GHz; N9910X-852 Coaxial adapter, Type-N (m) to Type-N (f), 18 GHz.

85038A

Standard cal kit 7/16 DC to 7.5 GHz Open, short, load (both female and male).

85514A

4-in-1 OSLT cal kit Type-N (m) DC to 9 GHz Open, short, load, thru (all male).

85515A

4-in-1 OSLT cal kit Type-N (f) DC to 9 GHz Open, short, load, thru (all female).

85032F

Standard cal kit Type-N DC to 9 GHz Open, short, load (both female and male).

85518A

4-in-1 OSLT cal kit Type-N (m) DC to 18 GHz Open, short, load, thru (all male).

85519A

4-in-1 OSLT cal kit Type-N (f) DC to 18 GHz Open, short, load, thru (all female).

85054D

Economy cal kit Type-N DC to 18 GHz Open, short, load, thru (both female and male).

85054B

Standard cal kit Type-N DC to 18 GHz Open, short, fixed load, sliding load (both female and male).

85092C

ECal, 2-ports Type-N 300 kHz to 9 GHz Connectors configurable.

N4690D

ECal, 2-ports Type-N 300 kHz to 18 GHz or DC to 18 GHz Connectors configurable.

N7550A

ECal economy, 2-ports Type-N DC to 4 GHz Connectors configurable.

N7551A

ECal economy, 2-ports Type-N DC to 6.5 GHz Connectors configurable.

N7552A

ECal economy, 2-ports Type-N DC to 9 GHz Connectors configurable.

N7553A

ECal economy, 2-ports Type-N DC to 14 GHz Connectors configurable.

N7554A

ECal economy, 2-ports Type-N DC to 18 GHz Connectors configurable.

85036B

Standard cal kit Type-N 75 Ω DC to 3 GHz Open, short, load (both female and male).

85096C

ECal, 2-ports Type-N(m) 75 Ω 300 kHz to 3 GHz Connectors configurable.

X11644A

Waveguide cal kit WR-90 8.2 to 12.4 GHz Short, shim, termination, standard section.

Calibration kits, 7-16

N9910X-802 3-in-1 OSL Cal kit 7/16 (m) DC to 4 GHz Open, short, load (all male); N9910X-803 3-in-1 OSL Cal kit 7/16 (f) DC to 4 GHz Open, short, load (all female).

Calibration kits, Type-N, 50 Ω

N9910X-800 3-in-1 OSL cal kit Type-N (m) DC to 6 GHz Open, short, load (all male); N9910X-801 3-in-1 OSL cal kit Type-N (f) DC to 6 GHz Open, short, load (all female); 85032E Economy cal kit Type-N (m) DC to 6 GHz Open, short, load (all male).

Calibration kits, Type-N, 75 Ω

85036E Economy cal kit Type-N(m) 75 Ω DC to 3 GHz Open, short, load, all male.

Calibration kits, Waveguide

N9911X-11x Econ. waveguide cal kit WR-137 5.38 to 8.18 GHz Short, termination, offset length; N9911X-21x Econ. waveguide cal kit WR-90 8.2 to 12.5 GHz Short, termination, offset length; N9911X-31x Econ. waveguide cal kit WR-62 11.9 to 18 GHz Short, termination, offset length; N9911X-41x Econ. waveguide cal kit WR-42 17.6 to 26.7 GHz Short, termination, offset length; P11644A Waveguide cal kit WR-62 12.4 to 18 GHz Short, shim, termination, standard section.

U2000A

USB Average 10 MHz to 18 GHz, -60 dBm to +20 dBm.

U2000B

USB Average 10 MHz to 18 GHz, -30 dBm to +44 dBm.

U2000H

USB Average 10 MHz to 18 GHz, -50 dBm to +30 dBm.

U2001A

USB Average 10 MHz to 6 GHz, -60 dBm to +25 dBm.

U2001B

USB Average 10 MHz to 6 GHz, -30 dBm to +44 dBm.

U2001H

USB Average 10 MHz to 6 GHz, -50 dBm to +30 dBm.

U2002A

USB Average 50 MHz to 24 GHz, -60 dBm to +20 dBm.

U2002H

USB Average 50 MHz to 24 GHz, -50 dBm to +30 dBm.

U2004A

USB Average 9 kHz to 6 GHz, -60 dBm to +20 dBm.

U2021XA

USB Average and peak 50 MHz to 18 GHz, -30 dBm to +20 dBm.

U2022XA

USB Average and peak 50 MHz to 40 GHz, -30 dBm to +20 dBm.

U2051XA

USB Average 10 MHz to 6 GHz, -70 dBm to +26 dBm.

U2052XA

USB Average 10 MHz to 18 GHz, -70 dBm to +26 dBm.

U2053XA

USB Average 10 MHz to 33 GHz, -70 dBm to +26 dBm.

U2054XA

USB Average 10 MHz to 40 GHz, -70 dBm to +20 dBm.

U2055XA

USB Average 10 MHz to 50/53 GHz, -70 dBm to +20 dBm.

U2056XA

USB Average 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

U2057XA

USB Average 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

U2062XA

USB Average and peak 10 MHz to 18 GHz, -70 dBm to +26 dBm.

U2063XA

USB Average and peak 10 MHz to 33 GHz, -70 dBm to +26 dBm.

U2064XA

USB Average and peak 10 MHz to 40 GHz, -70 dBm to +20 dBm.

U2065XA

USB Average and peak 10 MHz to 50/53 GHz, -70 dBm to +20 dBm.

U2066XA

USB Average and peak 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

U2067XA

USB Average and peak 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

U8481A

USB Average 10 MHz to 18 GHz, -35 dBm to +20 dBm.

U8485A

USB Average 10 MHz to 33 GHz, -35 dBm to +20 dBm.

U8487A

USB Average 10 MHz to 50 GHz, -35 dBm to +20 dBm.

U8488A

USB Average 10 MHz to 67 GHz, -35 dBm to +20 dBm.

U8489A

USB Average DC to 120 GHz, -35 dBm to +20 dBm.

L2051XA

LAN Average 10 MHz to 6 GHz, -70dBm to +26 dBm.

L2052XA

LAN Average 10 MHz to 18 GHz, -70dBm to +26 dBm.

L2053XA

LAN Average 10 MHz to 33 GHz, -70dBm to +26 dBm.

L2054XA

LAN Average 10 MHz to 40 GHz, -70dBm to +20 dBm.

L2055XA

LAN Average 10 MHz to 50/53 GHz, -70dBm to +20 dBm.

L2056XA

LAN Average 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

L2057XA

LAN Average 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

L2061XA

LAN Average and peak 10 MHz to 6 GHz, -70dBm to +26 dBm.

L2062XA

LAN Average and peak 10 MHz to 18 GHz, -70dBm to +26 dBm.

L2063XA

LAN Average and peak 10 MHz to 33 GHz, -70dBm to +26 dBm.

L2064XA

LAN Average and peak 10 MHz to 40 GHz, -70dBm to +20 dBm.

L2065XA

LAN Average and peak 10 MHz to 50/53 GHz, -70dBm to +20 dBm.

L2066XA

LAN Average and peak 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

L2067XA

LAN Average and peak 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

L2066XT

LAN Thermal Vacuum Compliance 10 MHz to 54 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz).

L2067XT

LAN Thermal Vacuum Compliance 10 MHz to 67 GHz, -70 dBm to +20 dBm (≤50 GHz), to +15 dBm (≤54 GHz), to +10 dBm (≤67 GHz).

U2049XA

LAN Average and peak 10 MHz to 33 GHz, -70dBm to +20 dBm.

Power sensors

U2041XA USB Average 10 MHz to 6 GHz, -70 dBm to +26 dBm; U2042XA USB Average and peak 10 MHz to 6 GHz, -70 dBm to +26 dBm; U2043XA USB Average 10 MHz to 18 GHz, -70 dBm to +26 dBm; U2044XA USB Average and peak 10 MHz to 18 GHz, -70 dBm to +26 dBm; L2065XT LAN Average and peak 10 MHz to 53 GHz, -70dBm to +20 dBm.

U7227A

USB preamplifier, 10 MHz to 4 GHz.

U7227C

USB preamplifier, 100 MHz to 26.5 GHz.

U7227F

USB preamplifier, 2 to 50 GHz.

Preamplifiers

U7228A USB preamplifier, 10 MHz to 4 GHz; U7228C USB preamplifier, 100 MHz to 26.5 GHz; U7228F USB preamplifier, 2 to 50 GHz.

Noise Sources

346A/B/C/CK01/CK40 Noise source family; U1832A USB smart noise source, 10 MHz to 18 GHz, 5 dB ENR nominal; U1832B USB smart noise source, 10 MHz to 26.5 GHz, 5 dB ENR nominal; U1832C USB smart noise source, 500 MHz to 50 GHz, 5 dB ENR nominal; U1833A USB smart noise source, 10 MHz to 18 GHz, 15 dB ENR nominal; U1833B USB smart noise source, 10 MHz to 26.5 GHz, 15 dB ENR nominal; U1833C USB smart noise source, 500 MHz to 50 GHz, 15 dB ENR nominal; U1833D USB smart noise source, 500 MHz to 60 GHz, 10 dB ENR nominal.

Keysight N9910XVDI (or VDI PSAX) Frequency Extender Modules

N9910XVDI VDI frequency extenders for FieldFox; N9910XVDI-W15 WR15 frequency extender, 50 to 75 GHz; N9910XVDI-W12 WR12 frequency extender, 60 to 90 GHz.

VDI Frequency Extender Module Adapter Kits

N9910XVDI-102 Male-type-N to male-SMA, Qty 2 of 1250-1636; N9910XVDI-104 Female-SMA to male-SMA adapter, right angle, for connecting GPS antenna or Trigg/Ref input; N9910XVDI-100 DC power cable replacement.

Recommended Services

R-55B-001-1 KeysightCare Enhanced - Upgrade 1 year; R-55B-001-2 KeysightCare Enhanced - Extend to 2 years; R-55B-001-3 KeysightCare Enhanced - Extend to 3 years (Recommended); R-55B-001-5 KeysightCare Enhanced - Extend to 5 years (Recommended); R-55A-001-2 KeysightCare Assured - Extend to 2 years; R-55A-001-3 KeysightCare Assured - Extend to 3 years; R-55A-001-5 KeysightCare Assured - Extend to 5 years; PS-S40-01 Included - instrument fundamentals and operations starter; PS-S40-04 Recommended - instrument fundamentals and operations starter; PS-S40-02 Optional, technology & measurement science standard learning.