Skip to product information
1 of 1
Used

Keysight N5227B 2-Port and 4-Port PNA Network Analyzer, 900 Hz to 67 GHz (Pre-Owned)

Keysight N5227B 2-Port and 4-Port PNA Network Analyzer, 900 Hz to 67 GHz (Pre-Owned)

Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Keysight N5227B 2-Port and 4-Port PNA Network Analyzer, 900 Hz to 67 GHz (Pre-Owned)

Key Features At A Glance

  • Frequency coverage from 900 Hz (with LFE options) or 10 MHz up to 67 GHz, with typical performance characterized to 70 GHz
  • Available in 2-port and 4-port configurations across multiple option tiers (200/201/219, 400/401/419) plus Low Frequency Extension variants (205/220, 405/420)
  • System dynamic range up to 133 dB (specification) in the 1–2 GHz band on standard 2-port configurations per the datasheet
  • Source and receiver attenuators on extended-power options (219/419/220/420) deliver minimum settable power down to -80 dBm
  • 1.85 mm test port connectors (50 ohm nominal) with optional front-panel jumpers and bias-tees on selected options
  • 10 Hz to 15 MHz nominal system IF bandwidth range with selectable IF bandwidths supporting tradeoff between sweep speed and trace noise
  • LXI Class C compliant with GPIB, LAN (10/100/1000 BaseT), and USB connectivity for automated test integration
  • Optional Low Frequency Extension (LFE) hardware enables measurements from 900 Hz (specified) down to 500 Hz (typical)
Share on
View full details

The Keysight N5227B is a 2-port or 4-port PNA Network Analyzer covering 900 Hz to 67 GHz, with typical performance characterized between 67 GHz and 70 GHz. It is offered in multiple configurations: base models (Option 200 for 2-port, Option 400 for 4-port), versions adding front-panel jumpers and R1 receiver switch (Option 201/401), versions adding extended power range with source and receiver attenuators plus bias-tees (Option 219/419), and Low Frequency Extension (LFE) variants (Option 205/220 for 2-port, 405/420 for 4-port) that add hardware for measurements down to 900 Hz specified and 500 Hz typical.

The datasheet positions the N5227B for S-parameter measurement applications spanning a wide frequency range. The instrument's specifications, error terms, and dynamic accuracy plots are characterized with the 85058B calibration kit and N4694A or N4694D 2-port Electronic Calibration Modules. Documentation references the Keysight Uncertainty Calculator for generating calibration-specific uncertainty curves, indicating the instrument is intended for applications where formal measurement uncertainty analysis is part of the workflow.

ValueTronics International has supplied calibrated test and measurement equipment from our 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois since 1992. Each {{CONDITION}} N5227B is processed through our in-house inspection and verification workflow before it ships, and our team is available to confirm option configurations and accessory inclusions against your application requirements before purchase.

Brand Heritage

Keysight Technologies was spun out from Agilent Technologies in 2014 as the dedicated electronic measurement business; Agilent itself was spun out from Hewlett-Packard in 1999. The PNA network analyzer family traces its engineering and product lineage through this HP-to-Agilent-to-Keysight progression.

Accessories Supplied

  • Handles (all models shipped with handles)

Product Core & Specifications

Specification Value
Frequency Range (Standard) 10 MHz to 67 GHz
Frequency Range (LFE Options) 900 Hz to 67 GHz
Frequency Range (Typical, extended) 67 GHz to 70 GHz; 500 Hz to 900 Hz (LFE)
Frequency Resolution 1 Hz
Frequency Accuracy ±0.7 ppm
Initial Frequency Accuracy ±0.2 ppm (spec), ±0.1 ppm (typical)
Frequency Stability ±0.05 ppm, -10° to 70° C; ±0.5 ppm (first year), typical
System IF Bandwidth Range 1 Hz to 15 MHz, nominal
Power Resolution 0.01 dB
Maximum Settable Power 30 dBm (typical)
Minimum Settable Power (Options 200, 201, 205, 400, 401, 405) -30 dBm (typical)
Minimum Settable Power (Options 219, 220, 419, 420) -80 dBm (typical)
Nominal (Preset) Power, Options 200/201/205/400/401/405 0 dBm
Nominal (Preset) Power, Options 219/220/419/420 -5 dBm
Damage Input Level, Options 200/201/219/400/401/419 27 dBm, 40 V
Damage Input Level, All LFE Options 20 dBm, 50 V
Test Port Connector 1.85 mm (male), 50 ohm, nominal
Center Pin Recession 0.002 in. (characteristic)
USB 2.0 Ports (Front Panel) 4 ports, USB Type-A female, compatible with USB 2.0
Display 31 cm (12.1 in) diagonal color active matrix LCD; 1280 (H) x 800 (V) resolution
Display Refresh Rate Vertical 60 Hz; Horizontal 49.31 kHz
10 MHz Reference In BNC female, 10 MHz ±1 ppm, 100 MHz ±1 ppm; 50 Ω nominal
10 MHz Reference Out BNC female, 10 MHz ±0.7 ppm, 100 MHz ±0.7 ppm; +10 dBm ±4 dB into 50 Ω
External IF Inputs SMA female; A, B, C, D, R (4-port); A, B, R1, R2 (2-port)
Pulse Inputs (IF Gates) 15-pin mini D-sub; Minimum pulse width 33 ns (source modulators), 20 ns (receiver gates)
Trigger Inputs/Outputs BNC(f), TTL/CMOS compatible
Test Set IO 25-pin D-Sub connector
Handler IO 36-pin parallel I/O port
GPIB Two ports - dedicated controller and dedicated talker/listener; 24-pin D-sub female; IEEE-488 compatible
USB Ports (Rear) Two SuperSpeed USB ports (900 mA each), one USB port below LAN connector, one USB device port
LAN 10/100/1000 BaseT Ethernet, 8-pin configuration
VGA Video Output 15-pin mini D-Sub
Mini DisplayPort Miniature DisplayPort connector
Line Frequency/Voltage 50/60/400 Hz for 100 to 120 VAC; 50/60 Hz for 220 to 240 VAC; auto switching
Maximum Power Consumption 575 watts
LXI Class C
Important: Damage input level on standard options (200, 201, 219, 400, 401, 419) is +27 dBm or 40 V; on all LFE options the damage level is +20 dBm or 50 V.Important: Calibration kits and ECal modules (such as the 85058B mechanical calibration kit, N4694A and N4694D 2-port Electronic Calibration Modules) are referenced in the datasheet for specifying corrected system performance, but are not included with the analyzer; they must be ordered separately.Important: A test port cable set (such as the N4697F flexible test port cable set referenced for corrected system performance) is required for full 2-port calibration and is not included with the base instrument.Important: Typical performance information between 67 GHz and 70 GHz is shown in this document where available. The performance is degraded at particular frequencies in this range due to the modes of the 1.85 mm connectors used in the analyzer, test port cables and adapters.Important: For all tables in this data sheet, the specified performance at the exact frequency of a break is the degraded value of the two specifications at that frequency.Important: All specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has been turned on.Recommended pairing: use the Keysight 85058B mechanical calibration kit or N4694A / N4694D 2-port Electronic Calibration Module — these are the calibration solutions whose corrected system performance is characterized in the N5227B datasheet.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Used

Manufacturer

Agilent

Frequency

900 Hz