Skip to product information
1 of 1

Keysight N5224B 900 Hz to 43.5 GHz 2-Port and 4-Port PNA Network Analyzer (Pre-Owned)

Keysight N5224B 900 Hz to 43.5 GHz 2-Port and 4-Port PNA Network Analyzer (Pre-Owned)

🎓 Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Keysight N5224B 900 Hz to 43.5 GHz 2-Port and 4-Port PNA Network Analyzer (Pre-Owned)

Key Features At A Glance

  • 2-port and 4-port S-parameter network analysis with 2.4 mm (male), 50-ohm test ports
  • Standard coverage from 10 MHz to 43.5 GHz (N5224B) or 50 GHz (N5225B); optional LFE extends to 900 Hz
  • GPIB (IEEE-488), Gigabit LAN, and USB interfaces standard for ATE integration and remote control
  • 31 cm (12.1 in) color active-matrix LCD at 1280 x 800 resolution
  • 1 Hz frequency resolution with ±0.7 ppm frequency accuracy
  • Optional source/receiver attenuators (extended power range) and internal bias-tees
  • Optional phase noise measurement application for absolute and residual phase/AM noise
View full details

The Keysight N5224B and N5225B are PNA-series microwave network analyzers built around synthesizer revision 7 and offered in both 2-port and 4-port configurations. The N5224B covers 10 MHz to 43.5 GHz and the N5225B covers 10 MHz to 50 GHz, with optional Low-Frequency Extension hardware lowering the start frequency to 900 Hz. Both instruments characterize the magnitude and phase of a device's transmission and reflection responses (S-parameters) across these ranges.

A vector network analyzer stimulates a device under test with a swept signal and measures how that device transmits and reflects energy, resolving both magnitude and phase at every frequency point. Beyond standard S-parameter sweeps, these analyzers support group-delay measurements, point-in-pulse and pulse-profile measurements through the rear-panel pulse I/O, and measurements on frequency-converting devices using external and remote mixers via the external test set driver and external IF inputs. With the optional phase noise measurement application, the instruments perform absolute phase noise and AM noise measurements along with single-channel and two-channel residual noise measurements.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned instrument is backed by our team of test-and-measurement specialists; each used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

Keysight Technologies traces its test-and-measurement heritage to Hewlett-Packard, whose instrument business was spun off as Agilent Technologies in 1999 and then established as Keysight Technologies in 2014. Products carrying the Keysight name continue that measurement lineage.

Compare Other Models in This Series

The N522xB PNA series places the N5224B and N5225B on a common platform that differs primarily in top frequency: the N5224B reaches 43.5 GHz and the N5225B reaches 50 GHz, both starting at 10 MHz, or at 900 Hz with the Low-Frequency Extension option. Each model is offered in 2-port and 4-port test-set configurations.

Within each model, options scale capability from a base test set through added front-panel jumpers and an R1 receiver switch, source and receiver attenuators for extended power range, and internal bias-tees. Low-Frequency Extension variants add the hardware needed for measurements below 10 MHz.

Each pre-owned model and configuration below is its own dedicated product page with condition-matched pricing. Choose the variant whose frequency range, port count, and option set match your application; the comparison table that follows summarizes how the models differ.

The principal difference across the family is the upper frequency limit: the N5224B is specified to 43.5 GHz and the N5225B to 50 GHz. Both share the same 10 MHz standard low end, the same optional 900 Hz Low-Frequency Extension, and the same 2-port and 4-port architectures, so the comparison table focuses on frequency coverage alongside the option-driven differences.

Option suffixes determine installed hardware rather than the core frequency range. The 2-port options (200, 201, 217, 219) and 4-port options (400, 401, 417, 419) add front-panel jumpers, an R1 receiver switch, extended-power-range attenuators, and bias-tees in increasing combinations, while the LFE options (205, 220, 405, 420) add low-frequency extension hardware. Refer to the comparison table for the per-model and per-option breakdown.

Model Frequency Range Frequency Range (LFE) Test Port Connector
N5224B 10 MHz to 43.5 GHz 900 Hz to 43.5 GHz 2.4 mm (male), 50 ohm
N5225B 10 MHz to 50 GHz 900 Hz to 50 GHz 2.4 mm (male), 50 ohm

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Bottom feet
  • Handles
  • Front and rear panel hardware

Product Core & Specifications

Specification Value
Frequency Information (Table 23)
N5224B Frequency Range 10 MHz to 43.5 GHz
N5224B Frequency Range (LFE Options) 900 Hz to 43.5 GHz (typical 500 Hz to 900 Hz)
Frequency Resolution 1 Hz
Frequency Accuracy ±0.7 ppm
Initial Frequency Accuracy ±0.2 ppm (typical ±0.1 ppm)
System Dynamic Range at Test Port (dB), Options 200 or 400 - Specification
10 MHz to 50 MHz Ports 1,3: 87; Ports 2,4: 85
50 MHz to 100 MHz Ports 1,3: 103; Ports 2,4: 101
100 MHz to 250 MHz Ports 1,3: 110; Ports 2,4: 110
250 MHz to 500 MHz Ports 1,3: 119; Ports 2,4: 119
500 MHz to 1 GHz Ports 1,3: 127; Ports 2,4: 128
1 GHz to 2 GHz Ports 1,3: 133; Ports 2,4: 134
2 GHz to 3.2 GHz Ports 1,3: 131; Ports 2,4: 132
3.2 GHz to 10 GHz Ports 1,3: 135; Ports 2,4: 132
10 GHz to 13.5 GHz Ports 1,3: 130; Ports 2,4: 130
13.5 GHz to 16 GHz Ports 1,3: 130; Ports 2,4: 130
16 GHz to 20 GHz Ports 1,3: 130; Ports 2,4: 130
20 GHz to 24 GHz Ports 1,3: 132; Ports 2,4: 132
24 GHz to 26.5 GHz Ports 1,3: 132; Ports 2,4: 131
26.5 GHz to 30 GHz Ports 1,3: 127; Ports 2,4: 127
30 GHz to 32 GHz Ports 1,3: 128; Ports 2,4: 128
32 GHz to 35 GHz Ports 1,3: 128; Ports 2,4: 128
35 GHz to 40 GHz Ports 1,3: 123; Ports 2,4: 124
40 GHz to 43.5 GHz Ports 1,3: 123; Ports 2,4: 124
Maximum Leveled Power (dBm), All Ports, Option 200/400 - Specification (Table 24)
10 MHz to 50 MHz 12
50 MHz to 16 GHz 13
16 GHz to 26.5 GHz 13
26.5 GHz to 30 GHz 13
30 GHz to 32 GHz 13
32 GHz to 35 GHz 13
35 GHz to 43.5 GHz 10
Noise Floor (dBm) @ 10 Hz IFBW, All Options, N5224B (Table 50)
10 MHz to 50 MHz Spec -70; Typical -75
50 MHz to 100 MHz Spec -85; Typical -91
100 MHz to 250 MHz Spec -95; Typical -100
250 MHz to 500 MHz Spec -102; Typical -107
500 MHz to 1 GHz Spec -106; Typical -112
1 GHz to 10 GHz Spec -114; Typical -118
10 GHz to 26.5 GHz Spec -114; Typical -120
26.5 GHz to 35 GHz Spec -110; Typical -116
35 GHz to 40 GHz Spec -108; Typical -116
40 GHz to 43.5 GHz Spec -108; Typical -114
Power (Tables 39, 40)
Power Resolution 0.01 dB
Maximum Settable Power 30 dBm (typical)
Minimum Settable Power, Option 200, 201, 205, 400, 401, 405 -30 dBm (typical)
Minimum Settable Power, Option 217, 219, 220, 417, 419, 420 -90 dBm (typical)
Nominal Power (Preset), Option 200, 201, 205, 400, 401, 405 0 dBm
Nominal Power (Preset), Option 217, 219, 220, 417, 419, 420 -5 dBm
2nd and 3rd Harmonics at Max Specified Power (dBc), All Options - Typical (Table 41)
10 MHz to 50 MHz 2nd: -15; 3rd: -15
50 MHz to 2 GHz 2nd: -21; 3rd: -15
2 GHz to 13.5 GHz 2nd: -18; 3rd: -19
13.5 GHz to 16.7 GHz 2nd: -60; 3rd: -65
16.7 GHz to 25 GHz 2nd: -60; 3rd: --
Phase Noise (dBc/Hz), All Options, with UNY, Port 1, 3 - Typical (Table 44)
CW 1 GHz -112 (100 Hz), -132 (1 kHz), -137 (10 kHz), -143 (100 kHz), -145 (1 MHz), -144 (10 MHz)
CW 5 GHz -103 (100 Hz), -123 (1 kHz), -132 (10 kHz), -135 (100 kHz), -147 (1 MHz), -150 (10 MHz)
CW 10 GHz -96 (100 Hz), -116 (1 kHz), -126 (10 kHz), -130 (100 kHz), -142 (1 MHz), -146 (10 MHz)
CW 20 GHz -91 (100 Hz), -111 (1 kHz), -118 (10 kHz), -123 (100 kHz), -135 (1 MHz), -139 (10 MHz)
CW 26.5 GHz -87 (100 Hz), -106 (1 kHz), -115 (10 kHz), -121 (100 kHz), -131 (1 MHz), -135 (10 MHz)
Damage Input Level, All Ports (Table 64)
Option 200, 201, 219, 400, 401, 419 27 dBm, 40 V
Option 217, 417 27 dBm, 7 V
All LFE Options 20 dBm, 50 V
General Information (Tables 75, 76)
System IF Bandwidth Range 1 Hz to 15 MHz, nominal
Maximum Number of Points 100003
RF Connector Type 2.4 mm (male), 50 ohm, nominal
Center Pin Recession 0.002 in. (characteristic)
USB 2.0 Ports - Primary 4 ports, USB Type-A female
Display 31 cm (12.1 in) diagonal color active matrix LCD; 1280 x 800 resolution
Line Power (Table 74)
Frequency, Voltage 50/60/400 Hz for 100/120 VAC; 50/60 Hz for 220/240 VAC; auto switching
Max Power 575 watts
Important: Damage input level (RF, DC): 27 dBm / 40 V for Options 200, 201, 219, 400, 401, 419; 27 dBm / 7 V for Options 217, 417; and 20 dBm / 50 V for all LFE options.
Important: All specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has been turned on.
Important: Effective dynamic range must take measurement uncertainties and interfering signals into account. The extended dynamic range set-up should only be used when the receiver input will never exceed its maximum receiver input; the extended range is only available in one-path transmission measurements and may typically be degraded at particular frequencies below 500 MHz due to spurious receiver residuals.
Important: Corrected system performance specifications apply with the 85133F flexible test port cable set and a full 2-port calibration (environmental temperature 23 °C ±3 °C, with < 1 °C deviation from calibration temperature). A compatible calibration kit and test port cable set are required and are referenced separately in this document.
Recommended pairing: specified corrected performance is achieved with a full 2-port calibration using Keysight 85056A or 85056D mechanical cal kits, or the N4693A/N4693D electronic calibration modules.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Pre-Owned

Manufacturer

Keysight Technologies

Net_ana_freq

10 MHz to 43.5 GHz