Skip to product information
1 of 1

Tektronix MDO4104-6 1 GHz Mixed Domain Oscilloscope, 6 GHz RF (Pre-Owned)

Tektronix MDO4104-6 1 GHz Mixed Domain Oscilloscope, 6 GHz RF (Pre-Owned)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Tektronix MDO4104-6 1 GHz Mixed Domain Oscilloscope, 6 GHz RF (Pre-Owned)

Key Features At A Glance

  • Four analog channels, 16 digital channels, and one RF channel for time-correlated mixed-domain analysis in one instrument
  • Analog bandwidth of 500 MHz or 1 GHz and RF input range of 50 kHz–3 GHz or 50 kHz–6 GHz across the series
  • ≥1 GHz ultra-wide RF capture bandwidth generates the spectrum from a single acquisition at spans of 1 GHz and below
  • MagniVu high-speed acquisition resolves digital-channel timing to 60.6 ps around the trigger point
  • 20M-point maximum record length and waveform capture rate greater than 50,000 wfm/s
  • 10.4 in. (264 mm) XGA color display with Wave Inspector navigation across time and frequency domains
  • Integrated 10/100/1000BASE-T Ethernet (LXI Class C), four USB 2.0 host ports, USB device port, and XGA video out
  • Optional serial trigger/decode/search for I2C, SPI, USB, CAN, LIN, FlexRay, UART, MIL-STD-1553 (separate module per bus)
View full details

The Tektronix MDO4000 Series is a Mixed Domain Oscilloscope — an oscilloscope with a built-in spectrum analyzer that captures time-correlated analog, digital, and RF signals in a single instrument. Each model combines four analog channels, 16 digital channels, and one RF channel, presenting a Time Domain view of the analog and digital channels in the upper half of the display and a Frequency Domain view of the RF input in the lower half. The Frequency Domain view is the spectrum acquired from the RF input, taken from a user-positioned window called Spectrum Time, which can be moved through the acquisition — live or stopped — to see how the RF spectrum changes over time.

The series is built to correlate events in the frequency domain with the time-domain phenomena that caused them. A representative application is tuning a VCO/PLL: probing the control signal that enables the VCO, the PLL voltage, and the SPI bus programming the device, then moving Spectrum Time across the acquisition to watch the oscillator settle to its target frequency. The frequency-vs-time trace makes it straightforward to see frequency hops and characterize how a device switches between frequencies, and the wide capture bandwidth lets a single acquisition capture bursted communications across separate bands — such as a 900 MHz and a 2.4 GHz transmission — at once. The series also supports general debugging across the discover, capture, search, and analyze stages, with application support for serial bus analysis, power supply design, limit and mask testing, and video.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer. Holding our own stock means the instrument you order is on our shelves and ready to move.

Brand Heritage

Tektronix was founded in 1946 and has operated under the Tektronix name throughout its history. It was acquired by Danaher Corporation in 2007, and in 2016 it became part of Fortive Corporation when Fortive was spun off from Danaher.

Compare Other Models in This Series

The MDO4000 Series is introduced as the world's first oscilloscope with a built-in spectrum analyzer, letting you use the oscilloscope itself to look at the frequency domain rather than learning a separate spectrum analyzer. Its defining capability is correlating events in the frequency domain with the time-domain phenomena that caused them, showing a Time Domain view of the analog and digital channels alongside a Frequency Domain view of the RF input.

The series is based on the MSO4000B Mixed Signal Oscilloscope Series and carries the same comprehensive debug feature set across the discover, capture, search, and analyze stages. Four models make up the family, differing in analog bandwidth and RF frequency range while sharing four analog channels, 16 digital channels, one RF channel, a 10.4 in. XGA display, and ≥1 GHz of RF capture bandwidth.

Each model in the series links to its own dedicated product page with condition-matched pricing. The pre-owned unit you are viewing reflects the model and configuration shown here; use the comparison below to confirm the analog bandwidth and RF frequency range that match your application before selecting a model.

The four models divide along two axes. Analog bandwidth is either 500 MHz (MDO4054-3 and MDO4054-6) or 1 GHz (MDO4104-3 and MDO4104-6); the 1 GHz models provide a 5 GS/s sample rate and a 350 ps calculated rise time, while the 500 MHz models provide 2.5 GS/s and a 700 ps calculated rise time. RF frequency range is either 50 kHz–3 GHz on the -3 models or 50 kHz–6 GHz on the -6 models.

Some capabilities track the analog-bandwidth tier: high-speed USB serial triggering and analysis is supported only on the MDO4104-3 and MDO4104-6. Shared across all four models are 16 digital channels with MagniVu 60.6 ps timing resolution, a 20M-point record length, ≥1 GHz RF capture bandwidth, and the full mixed-domain display. See the comparison table for the per-model values.

Model Analog Bandwidth RF Frequency Range Max Sample Rate
MDO4104-6 1 GHz 50 kHz - 6 GHz 5 GS/s
MDO4054-3 500 MHz 50 kHz - 3 GHz 2.5 GS/s
MDO4104-3 1 GHz 50 kHz - 3 GHz 5 GS/s
MDO4054-6 500 MHz 50 kHz - 6 GHz 2.5 GS/s

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • One TPP1000 1 GHz, 10X, 3.9 pF passive voltage probe per analog channel
  • P6616 16-channel Logic Probe
  • Logic Probe Accessory Kit (020-2662-xx)
  • Front Cover (200-5130-xx)
  • N-to-BNC Adapter (103-0045-00)
  • User Manual (071-2918-xx)
  • Documentation CD (063-4367-xx)
  • OpenChoice Desktop Software
  • NI LabVIEW SignalExpress Tektronix Edition Software
  • Calibration Certificates documenting measurement traceability
  • Power cord
  • Accessory bag (016-2030-xx)
  • Three-year warranty

Product Core & Specifications

Specification Value
Acquisition & Channels (Model-Specific)
Analog Channels 4
Analog Bandwidth (–3 dB) 1 GHz
Calculated Rise Time (5 mV/div, typical) 350 ps
Sample Rate (1-2 ch) 5 GS/s
Sample Rate (3-4 ch) 2.5 GS/s
Digital Channels 16
Maximum Duration at Highest Sample Rate (All/Half channels) 8/4 ms
Time Base Range 400 ps to 1,000 s
Peak Detect (captures glitches as narrow as) 800 ps
RF Input (Model-Specific)
RF Channels 1
Frequency Range 50 kHz - 6 GHz
Span 1 kHz - 6 GHz in a 1-2-5 sequence
Power Level Trigger Frequency Range 1 MHz - 6 GHz
Displayed Average Noise Level (DANL), 3 GHz - 6 GHz < –140 dBm/Hz (< –143 dBm/Hz typical)
USB High-speed Serial Trigger/Decode Support Supported (high-speed available on MDO4104-X models)
Important: Maximum input voltage, 1 MΩ: 300 VRMS CAT II with peaks ≤ ±425 V. Maximum input voltage, 50 Ω: 5 VRMS with peaks < ±20 V.
Important: USB high-speed serial triggering and analysis support is only available on the MDO4104-3 and MDO4104-6 (MDO4104-X) models.
Important: Please specify power plug and manual language version when ordering.
Important: Probes and accessories are not covered by the oscilloscope warranty and service offerings; refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.
Important: The optional TPA-N-VPI adapter is required to connect any active, 50 Ω TekVPI probe to the RF input.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Tektronix

Condition

Pre-Owned

Manufacturer

Tektronix

Osc_ch

4

Osc_freq

1 GHz

Osc_r

1 MΩ, 50 Ω

Osc_sampl

5 GS/s