Key Features At a Glance — FPC1000

  • Frequency range: 5 kHz to 1 GHz base, upgradable to 2 GHz (FPC-B2) or 3 GHz (FPC-B2 + FPC-B3) via keycode — no additional calibration required
  • Maximum input power: Up to +30 dBm; +33 dBm CW RF input rating (= 2 W)
  • Low noise floor: Down to –165 dBm typical with R&S FPC-B22 preamplifier; –150 dBm typical without preamplifier (10 MHz to 2 GHz)
  • Optional frequency upgrades to 2 GHz or 3 GHz via keycode (no tracking generator on this model — choose FPC1500 if S21 transmission or VNA capability is required)
  • Measurement options (keycode-activated): AM/FM/ASK/FSK modulation analysis (FPC-K7), EMI receiver mode with CISPR detectors (FPC-K43), advanced measurements including channel power, OBW, spectrogram, harmonics, TDMA, TOI (FPC-K55)
  • Connectivity: LAN (10/100BASE-T), USB 2.0, plus optional Wi-Fi 802.11 b/g/n via FPC-B200
  • Display: 10.1" capacitive touchscreen, 1366 × 768 resolution
  • 100% software-upgradeable — no downtime, instant option availability via keycode
View full details

In summary, the Rohde & Schwarz FPC1000 is a compact, frequency-upgradeable benchtop spectrum analyzer covering 5 kHz to 1 GHz at the base configuration, extendable to 3 GHz via keycode-activated software options. It is the spectrum-analyzer-only variant of the FPC family — the same RF front end and measurement engine as the FPC1500, without the tracking generator or VNA option, suited to spectrum-only workflows where transmission and reflection measurement are not required. R&S markets this product line under the tagline "Value of Three" — buy only what is needed, invest when needed, upgrade as needed.

What is the R&S FPC1000 used for?

The FPC1000 is used for RF device development (including IoT modules), EMI debugging and pre-compliance, modulation analysis on AM/FM/ASK/FSK signals, and general spectrum-domain characterization of RF circuits, transmitters, and ambient signal environments. It is positioned for design engineers, EMC pre-compliance labs, educational and training environments, and field-service technicians who need full-bench spectrum analyzer performance without the weight or footprint of a high-end SA.

Who buys the R&S FPC1000, and why?

Buyers are typically RF design engineers, EMC pre-compliance labs, university engineering programs, and field-service teams working in IoT, sub-3-GHz wireless, broadcast, and avionics-adjacent applications. The investment-protection argument — every option is keycode-activated with no additional calibration — is the deciding factor for budget-constrained labs that need a path from 1 GHz today to 3 GHz with VNA next quarter, all without re-shipping the instrument to a service center.

The base unit ships with a 3-year warranty and a 1-year recommended calibration interval. With the FPC-B22 preamplifier engaged, displayed average noise level reaches –165 dBm typical from 10 MHz to 2 GHz — a sensitivity floor that makes near-field probing of low-power IoT transmitters and CISPR pre-compliance scans practical on the same bench. Total measurement uncertainty is specified at < 1.25 dB (0.5 dB typ.) over 10 MHz to 3 GHz at 95% confidence, with the standard 2-MHz to 3-GHz tracking generator output (FPC1500 only — not available on this FPC1000 model).

The FPC platform aligns with the CISPR 11 / EN 55011 group 1 class A emission framework and EN 61326 table 2 industrial immunity envelope, and the FPC-K43 receiver mode adds CISPR-defined bandwidths (200 Hz, 9 kHz, 120 kHz, 1 MHz) and the quasi-peak detector required by formal EMI standards. Rohde & Schwarz, founded in Munich in 1933 and still privately held, is one of the recognized authorities in RF measurement instrumentation alongside Keysight and Anritsu — a useful credential when measurement defensibility matters for audit, regulatory submission, or supplier qualification.

How does the FPC1000 differ from comparable swept analyzers?

  • Investment protection through keycode upgrades. Bandwidth (1 → 2 → 3 GHz), preamplifier, modulation analysis, receiver mode, advanced measurements, and Wi-Fi are all activated by software keycode. No hardware return, no recalibration cycle, no downtime.
  • Sensitivity with preamplifier. –165 dBm typical DANL (10 MHz to 2 GHz, FPC-B22 on) is competitive with much larger benchtop SAs and is the dividing line for many low-power IoT and EMI applications.
  • Spectrum-only focus. Lower acquisition cost than the FPC1500 for benches that do not require tracking generator or VNA capability — but the upgrade path to the FPC1500 feature set is via separate hardware, so confirm the workflow before purchase.
  • Wi-Fi remote operation. FPC-B200 enables 802.11 b/g/n client-mode access to the instrument GUI, eliminating LAN cabling on benches where the analyzer is mounted in an environmental chamber, anechoic enclosure, or remote test fixture.

Accessories Supplied

Item Description
Power cable Region-specific AC power cable
USB cable USB cable for connection to PC
Base instrument R&S FPC spectrum analyzer base unit

About the R&S FPC1000 — Product Core & Specifications

The Rohde & Schwarz FPC family is built around a single commercial premise: an engineer should be able to buy the spectrum-analyzer capability they need today, knowing every additional capability is one keycode away from the same chassis. The FPC1000 (order number 1328.6660.02) is the spectrum-only variant — covering 5 kHz to 1 GHz at base, without a tracking generator.

Among analyzers in the ValueTronics catalog, spectrum analyzers are the most requested RF instrument. They answer the questions an oscilloscope cannot — what signals are present, at what frequency, at what power level, is there interference, is a transmitter on the right channel, is signal leaking into adjacent channels. The FPC1000 is sized and priced for the benchtop tier of that market: design engineers working on sub-3-GHz RF circuits, IoT modules, embedded radios, EMI pre-compliance, and educational programs.

The "Value of Three" Architecture

R&S positions the FPC1500 platform around three upgrade axes — frequency, sensitivity, and measurement function — all delivered through keycode-activated software upgrades:

  1. Frequency: 1 GHz → 2 GHz (FPC-B2) → 3 GHz (FPC-B2 + FPC-B3)
  2. Sensitivity: Add the FPC-B22 preamplifier for a –165 dBm typical DANL floor (10 MHz to 2 GHz)
  3. Measurement function: Modulation analysis (K7), EMI receiver mode (K43), advanced measurements (K55), Wi-Fi (B200)

Because every upgrade is keycode-activated, there is no instrument downtime, no shipping to a calibration facility for option installation, and no additional calibration step required after the keycode is entered. For labs with active project schedules, this is the operational advantage that differentiates the FPC platform from analyzers that require physical hardware swaps for capability expansion.

Options at a Glance

Option Description Order No.
R&S FPC-B2 Spectrum Analyzer Frequency Upgrade to 2 GHz 1328.6677.02
R&S FPC-B3 Spectrum Analyzer Frequency Upgrade to 3 GHz (requires R&S FPC-B2) 1328.6683.02
R&S FPC-B22 Spectrum Analyzer Preamplifier 1328.6690.02
R&S FPC-B200 Wi-Fi Connection Support 1328.6990.02
R&S FPC-K7 Modulation Analysis for AM, FM, ASK, FSK 1328.6748.02
R&S FPC-K43 Receiver Mode 1328.6754.02
R&S FPC-K55 Advanced Measurements 1328.6760.02
Note: Vector Network Analyzer option (R&S FPC-K42) and tracking generator functions are only available on the FPC1500.

Complete Specifications

Frequency

Frequency range (base) 5 kHz to 1 GHz
With R&S FPC-B2 option installed 5 kHz to 2 GHz
With R&S FPC-B2 and FPC-B3 options installed 5 kHz to 3 GHz
Frequency resolution 1 Hz
Reference frequency — aging per year 1 × 10⁻⁶
Temperature drift (0 °C to +30 °C) 1 × 10⁻⁶
Temperature drift (+30 °C to +50 °C) 3 × 10⁻⁶
Achievable initial calibration accuracy 5 × 10⁻⁷
Marker resolution 0.1 Hz
Number of sweep (trace) points 1183
Frequency counter resolution 0.1 Hz
Frequency span (base) 0 Hz, 10 Hz to 1 GHz (up to 3 GHz with options)
Span uncertainty 1% (nom.)
SSB phase noise at f = 500 MHz, 30 kHz offset < –88 dBc (1 Hz); –92 dBc (1 Hz) typ.
SSB phase noise at f = 500 MHz, 100 kHz offset < –98 dBc (1 Hz); –103 dBc (1 Hz) typ.
SSB phase noise at f = 500 MHz, 1 MHz offset < –120 dBc (1 Hz); –125 dBc (1 Hz) typ.

Sweep Time & Bandwidth

Sweep time (span = 0 Hz) 100 µs to 100 s
Sweep time (10 Hz ≤ span ≤ 600 MHz) 20 ms to 1000 s
Sweep time (span > 600 MHz) 20 ms × span/600 MHz to 1000 s
Sweep time uncertainty (span = 0 Hz) 1% (nom.)
Sweep time uncertainty (span ≥ 10 Hz) 3% (nom.)
Resolution bandwidth range (–3 dB) 1 Hz to 3 MHz in 1/3 sequence
RBW accuracy (1 Hz ≤ RBW ≤ 300 kHz) < 5% (nom.)
RBW accuracy (300 kHz < RBW ≤ 1 MHz) < 10% (nom.)
Selectivity (60 dB : 3 dB) < 5 (nom.), Gaussian-type filters
Video filter range (–3 dB) 1 Hz to 3 MHz in 1/3 sequence

Level

Display range Displayed noise floor to +30 dBm
Maximum rated input — DC voltage 50 V
Maximum rated input — CW RF power, RF input 33 dBm (= 2 W)
Peak RF power, RF input, duration < 3 s 36 dBm (= 4 W)
Max. pulse voltage 150 V
Max. pulse energy (pulse width 10 µs) 10 mWs
TOI at fin = 1 GHz, RF att = 0 dB, preamp off +7 dBm (meas.)
TOI at fin = 2.4 GHz, RF att = 0 dB, preamp off +10 dBm (meas.)
TOI at fin = 1 GHz, RF att = 10 dB, preamp off +17 dBm (meas.)
TOI at fin = 2.4 GHz, RF att = 10 dB, preamp off +20 dBm (meas.)
Second harmonic intercept (SHI), fin = 20 MHz to 1.5 GHz –60 dBc (nom.)
DANL 1 MHz to 10 MHz, preamp off < –127 dBm; –135 dBm (typ.)
DANL 10 MHz to 2 GHz, preamp off < –142 dBm; –150 dBm (typ.)
DANL 2 GHz to 3 GHz, preamp off < –138 dBm; –147 dBm (typ.)
DANL 1 MHz to 10 MHz, preamp on (requires FPC-B22) < –147 dBm; –157 dBm (typ.)
DANL 10 MHz to 2 GHz, preamp on (requires FPC-B22) < –158 dBm; –165 dBm (typ.)
DANL 2 GHz to 3 GHz, preamp on (requires FPC-B22) < –155 dBm; –163 dBm (typ.)
Residual spurious response < –90 dBm (nom.), input matched 50 Ω, no input signal, RBW ≤ 30 kHz, f ≥ 3 MHz, RF att = 0 dB, Wi-Fi disabled
Number of traces 2
Trace detectors Max. peak, min. peak, auto peak, sample, RMS
Trace functions Clear/write, max. hold, min. hold, average, view
Reference level setting range –130 dBm to +30 dBm
Units of level axis dBm, dBmV, dBµV, V, W
Absolute level uncertainty at 100 MHz (+20 °C to +30 °C) < 0.3 dB
Frequency response 10 MHz ≤ f ≤ 3 GHz < 1 dB
Total measurement uncertainty, 10 MHz ≤ f ≤ 3 GHz, 95% confidence < 1.25 dB; 0.5 dB (typ.)
Input attenuator 0 dB to 40 dB in 5 dB steps

Trigger Functions

Trigger source Free run, video, external, IQ power (FPC-K7 ASK/FSK only)
External trigger level — low → high transition 2.4 V
External trigger level — high → low transition 0.7 V
External trigger level — maximum 3.0 V

RF Input

Impedance 50 Ω (nom.)
Connector N female
VSWR (5 kHz ≤ f ≤ 1 GHz) < 1.5 (nom.)
VSWR (1 GHz < f ≤ 3 GHz) < 2 (nom.)

AF Output, External Reference, External Trigger

AF demodulation types AM and FM
AF connector 3.5 mm mini jack
AF output impedance 32 Ω (nom.)
AF voltage (open circuit) VRMS adjustable from 0 V to > 100 mV
External reference / trigger connector BNC, 50 Ω
External reference required level 0 dBm
External reference frequency 10 MHz

General Data

AC supply input 100 V to 240 V AC, 50 Hz to 60 Hz, 0.6 A to 0.4 A
Power consumption 14 W (nom.) — FPC1000
Safety IEC 61010-1, EN 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010.1
Test mark VDE, GS, CSA, KC
Languages Chinese, English, French, German, Italian, Hungarian, Japanese, Korean, Portuguese, Russian, Spanish
Remote command set SCPI 1997.0
LAN interface 10/100BASE-T, RJ-45
USB interface Type B plug, version 2.0 (PC); 2 × Type A plug, version 2.0 (host)
Display 10.1", 1366 × 768 pixel, < 2 pixel errors
Audio speaker Internal
Mass memory Memory stick (not supplied), size ≤ 4 Gbyte, USB 1.1 or 2.0
Internal data storage > 256 instrument settings and traces
Memory stick data storage (≥ 1 Gbyte) > 5000 instrument settings and traces
Operating temperature +10 °C to +40 °C
Storage temperature –20 °C to +70 °C
Climatic loading +25 °/+40 °C at 85% relative humidity, EN 60068-2-30
Vibration (sinusoidal) EN 60068-2-6
Vibration (random) EN 60068-2-64
Shock 40 g shock spectrum, MIL-STD-810F method 516.4 procedure 1, EN 60068-2-27
EMC European EMC Directive 2014/30/EU, CISPR 11/EN 55011 group 1 class A (emission), EN 61326 table 2 (immunity, industrial)
Dimensions (W × H × D) without feet 396 mm × 178 mm × 147 mm (15.6 in × 7.0 in × 5.8 in)
Dimensions (W × H × D) including feet 396 mm × 185 mm × 156 mm (15.6 in × 7.3 in × 6.1 in)
Weight 3 kg (6.6 lb)
Recommended calibration interval 1 year
Base unit warranty (new) 3 years

R&S FPC-K7 Modulation Analysis (Option)

The FPC-K7 modulation analysis option adds AM, FM, ASK, and FSK demodulation, including dedicated modes for Bluetooth Low Energy (BLE) and tire pressure monitoring systems (TPMS).

Center frequency (analog modulation) 10 MHz to 3 GHz
Demodulation bandwidth (analog) 2 MHz, 1 MHz, 500 kHz, 300 kHz, 200 kHz, 100 kHz, 50 kHz, 30 kHz, 20 kHz, 10 kHz (nom.)
Bandwidth accuracy < ±5% (nom.)
AM display Carrier power, carrier frequency offset, AM modulation depth, modulation frequency, THD, SINAD
FM display Carrier power, carrier frequency offset, FM deviation, modulation frequency, THD, SINAD
AM modulation depth measurement range 5% to 95% (nom.)
AM modulation depth uncertainty ±4% (nom.)
FM frequency deviation range 10 kHz to 400 kHz (nom.), max. 0.4 × demodulation bandwidth
FM deviation uncertainty ±(0.04 × (AF + deviation)) (nom.)
ASK / FSK center frequency 10 MHz to 3 GHz
ASK / FSK demodulation bandwidth 400 Hz to 2 MHz, auto-set to signal and demodulation requirements
ASK symbol rate range 1 kHz to 100 kHz (nom.)
ASK modulation depth range 5% to 95% (nom.), uncertainty ±4% (nom.)
FSK symbol rate range 1 kHz to 100 kHz (nom.)
FSK frequency deviation range 1 kHz to 400 kHz (nom.), accuracy ±4% (nom.)
Carrier power range (digital) –30 dBm to +20 dBm (nom.)

R&S FPC-K43 Receiver Mode (Option)

The FPC-K43 receiver mode option enables EMI debugging with CISPR-compliant bandwidths and detectors, including a quasi-peak detector. Near-field probe sets are available separately.

Measurements Fixed frequency, channel scan, channel scan (user-defined list), EMI precompliance (CISPR bandwidths, CISPR detectors)
Measurement modes Fixed frequency, frequency scan, channel scan
Frequency scan step size 100 Hz to max. frequency
Max. number of scan steps 10000
Channel spacing User-definable
Max. number of channels 10000
Resolution bandwidth range (–3 dB) 1 Hz to 3 MHz in 1/3 sequence
CISPR bandwidths (–6 dB) 200 Hz, 9 kHz, 120 kHz, 1 MHz
Detectors Max. peak, average, RMS, quasi-peak

R&S FPC-K55 Advanced Measurements (Option)

The FPC-K55 advanced measurements option adds measurement functions for channel power, occupied bandwidth, spectrogram display, harmonic distortion, TDMA power, AM modulation depth, and third-order intercept.

  • Spectrogram
  • Channel power
  • Occupied bandwidth
  • Third-order intercept
  • Harmonic distortion
  • TDMA power
  • AM modulation depth

R&S FPC-B200 Wi-Fi Connection Support (Option)

The FPC-B200 enables the integrated Wi-Fi module for cable-free remote access to the instrument. Wi-Fi feature availability depends on local certification requirements.

Interface Wireless LAN 802.11 b/g/n, 2.4 GHz
Operating modes Client mode
Certifications CE, ETSI, FCC, IC approval

Compatible Accessories

Accessory Description Order No.
R&S ZZA-FPC1 19" Rackmount Kit 1328.7080.02
R&S RTM-Z3 Soft Carrying Bag 1305.0289.02
R&S RTB-Z3 Carrying Case 1333.1734.02
R&S FSH-Z29 Combined Open/Short/50 Ω Load Calibration Standard, DC to 4 GHz 1300.7510.03
R&S ZN-Z103 1-Port Calibration Unit (male) 1321.1828.02
R&S HZ-15 Near-field probes, 30 MHz to 3 GHz (set of 5 probes)
R&S HZ-16 Amplifier, 100 kHz to 3 GHz
R&S HZ-17 Near-field probes, 30 MHz to 3 GHz (set of 2 probes)
R&S FPC-Z10 Teaching Kit 1328.7338.02

Service & Warranty

Base unit warranty (new) 3 years
Accessories warranty 1 year (installed options inherit remaining base unit warranty if longer than 1 year; all batteries 1 year)
R&S WE1 / WE2 Extended warranty, 1-year or 2-year terms — repairs (including necessary calibration and adjustments) free of charge during contract term
R&S CW1 / CW2 Extended warranty with calibration coverage, 1-year or 2-year terms — adds regular calibration, inspection, and maintenance at recommended intervals
Recommended calibration interval 1 year

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturers Data Sheet to verify published specifications. Feedback on this webpage is always welcome, please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.