Keysight E5092A 50 MHz to 20 GHz Configurable Multiport Test Set (Pre-Owned)

Keysight E5092A 50 MHz to 20 GHz Configurable Multiport Test Set (Pre-Owned)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Keysight E5092A 50 MHz to 20 GHz Configurable Multiport Test Set (Pre-Owned)

Key Features At A Glance

  • Frequency coverage from 9 kHz to 4.5, 6.5, or 9 GHz across the series (option dependent)
  • Configurable as 2-port or 4-port test sets, each with built-in bias tees
  • LAN (10/100BaseT), GPIB (IEEE-488), USBTMC device, USB host, and 36-pin Handler I/O for ATE integration
  • 12.1-inch WXGA (1280 x 800) TFT color LCD with touchscreen operation
  • Type-N 50 ohm test ports; damage level +27 dBm or +/-35 VDC
  • System dynamic range up to 135 dB (10 Hz IFBW spec), 152 dB typical (3 Hz IFBW)
  • Optional high-stability frequency reference (Option 1E5) at +/-0.45 ppm
View full details

The E5080A ENA Vector Network Analyzer covers 9 kHz to 4.5, 6.5, or 9 GHz and is offered in 2-port and 4-port configurations, each supplied with built-in bias tees. The series spans six ordering options (245, 265, 295, 445, 465, and 495) that set the frequency ceiling and port count, all sharing the same Type-N 50 ohm test-port architecture and 12.1-inch touchscreen front panel.

A vector network analyzer characterizes components and networks by measuring how they reflect and transmit signals across frequency, resolving both magnitude and phase of the resulting S-parameters. The E5080A reports corrected system performance in terms of directivity, source match, load match, and reflection and transmission tracking when used with its supported calibration kits and ECal modules, the standard quantities used to qualify reflection and transmission measurements.

ValueTronics stocks its inventory directly from a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.

Brand Heritage

Keysight Technologies traces its test and measurement heritage to Hewlett-Packard, whose instrument business was spun off as Agilent Technologies in 1999. Agilent's electronic measurement group was then established as Keysight Technologies in 2014, the name under which this product is issued.

Compare Other Models in This Series

The E5080A ENA series is offered as a set of options that differ in two dimensions: the upper frequency limit (4.5, 6.5, or 9 GHz) and the number of test ports (2-port or 4-port), with bias tees included on every option. All variants share the same Type-N 50 ohm test ports, 12.1-inch WXGA touchscreen, selectable 1 Hz to 1.5 MHz IF bandwidth, and the same source and receiver architecture.

Each model below links to its own product page. The option suffix encodes the configuration directly: the first digit indicates port count (2 or 4) and the trailing digits indicate the frequency tier, so option selection maps cleanly to the frequency reach and channel count the application requires.

Each pre-owned model below is its own dedicated product page with condition-matched pricing. Select the option that matches the frequency range, port count, and configuration you need, then choose the listing for your preferred condition.

The options divide along frequency and port count: options 245/265/295 are 2-port test sets reaching 4.5, 6.5, and 9 GHz respectively, while options 445/465/495 are the corresponding 4-port test sets. The 2-port options have a net weight of 20.3 kg and the 4-port options 22.7 kg, with line power consumption of 135 W for 2-port and 165 W for 4-port configurations.

Refer to the comparison table for the per-option frequency range and port count. The Option 1E5 high-stability oven reference (+/-0.45 ppm) is an add-on that can apply across the configurations and is separate from the base frequency and port-count selection.

Model Frequency Range Number of Ports System Dynamic Range
E5092A 50 MHz to 20 GHz 38 test ports
E5080A 9 kHz to 4.5 GHz 2 135 dB (50 MHz to 6 GHz)
E5080A 9 kHz to 6.5 GHz 2 135 dB (50 MHz to 6 GHz)
E5080A 9 kHz to 9 GHz 2 135 dB (50 MHz to 6 GHz)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
Test Set Input/Output Performance
Frequency range 50 MHz to 20 GHz
Damage level 20 dBm, ± 35 VDC
Option E5092A-020 Port Performance — Load Match (selected port)
SPDT switch, 50 MHz to 2 GHz 17 dB
SPDT switch, 2 GHz to 4 GHz 11 dB
SPDT switch, 4 GHz to 8 GHz 8 dB
SPDT switch, 8 GHz to 10 GHz 7 dB
SPDT switch, 10 GHz to 18 GHz 4 dB
SPDT switch, 18 GHz to 20 GHz 4 dB
SP4T switch, 50 MHz to 2 GHz 17 dB
SP4T switch, 2 GHz to 3 GHz 11 dB
SP4T switch, 3 GHz to 8 GHz 8 dB
SP4T switch, 8 GHz to 10 GHz 7 dB
SP4T switch, 10 GHz to 18 GHz 4 dB
SP4T switch, 18 GHz to 20 GHz 4 dB
Load Match (unselected port)
SPDT switch, 50 MHz to 3 GHz 17 dB
SPDT switch, 3 GHz to 10 GHz 11 dB
SPDT switch, 10 GHz to 16 GHz 8 dB
SPDT switch, 16 GHz to 18 GHz 6 dB
SPDT switch, 18 GHz to 20 GHz 4 dB
SP4T switch, 50 MHz to 3 GHz 17 dB
SP4T switch, 3 GHz to 10 GHz 11 dB
SP4T switch, 10 GHz to 16 GHz 8 dB
SP4T switch, 16 GHz to 18 GHz 6 dB
SP4T switch, 18 GHz to 20 GHz 4 dB
Load Match (common port)
SPDT switch, 50 MHz to 2 GHz 16 dB
SPDT switch, 2 GHz to 4 GHz 11 dB
SPDT switch, 4 GHz to 8 GHz 8 dB
SPDT switch, 8 GHz to 10 GHz 7 dB
SPDT switch, 10 GHz to 20 GHz 4 dB
SP4T switch, 50 MHz to 1.3 GHz 16 dB
SP4T switch, 1.3 GHz to 4 GHz 11 dB
SP4T switch, 4 GHz to 8 GHz 8 dB
SP4T switch, 8 GHz to 10 GHz 7 dB
SP4T switch, 10 GHz to 20 GHz 4 dB
Insertion Loss
SPDT switch, 50 MHz to 100 MHz 4 dB
SPDT switch, 100 MHz to 2 GHz 3.5 dB
SPDT switch, 2 GHz to 3 GHz 4.5 dB
SPDT switch, 3 GHz to 4 GHz 5 dB
SPDT switch, 4 GHz to 6 GHz 5.5 dB
SPDT switch, 6 GHz to 8 GHz 7 dB
SPDT switch, 8 GHz to 10 GHz 8 dB
SPDT switch, 10 GHz to 14 GHz 8.5 dB
SPDT switch, 14 GHz to 18 GHz 10 dB
SPDT switch, 18 GHz to 20 GHz 11.5 dB
SP4T switch, 50 to 100 MHz 4 dB
SP4T switch, 100 MHz to 2 GHz 3.5 dB
SP4T switch, 2 GHz to 3 GHz 4.5 dB
SP4T switch, 3 GHz to 4 GHz 5.5 dB
SP4T switch, 4 GHz to 6 GHz 6 dB
SP4T switch, 6 GHz to 8 GHz 7.5 dB
SP4T switch, 8 GHz to 10 GHz 8.5 dB
SP4T switch, 10 GHz to 14 GHz 9.5 dB
SP4T switch, 14 GHz to 18 GHz 10.5 dB
SP4T switch, 18 GHz to 20 GHz 12 dB
Isolation
50 MHz to 500 MHz 65 dB
500 MHz to 1 GHz 80 dB
1 GHz to 2 GHz 85 dB
2 GHz to 6 GHz 90 dB
6 GHz to 10 GHz 85 dB
10 GHz to 18 GHz 75 dB
18 GHz to 20 GHz 65 dB (over arbitrarily test ports)
Control Line
Number of groups 4 (Group A: 8 bits; Group B, C, D: 4 bits)
Input voltage range 0 V to +5 V (positive input); —5 V to 0 V (negative input)
Maximum current Group A, B: 50 mA in total of each group; Group C, D: 500 uA in total of each group
Impedance Group A, B: < 10 ohm; Group C, D: < 200 ohm
DC Source
Number of sources 4
Output voltage range 0 V to +5.2 V (nominal)
Output voltage accuracy ± 3 % of setting (+1 V to +5 V) at 1 M ohm load impedance
Voltage resolution 10 mV (nominal)
Maximum current 150 mA for each source
Output impedance < 5 ohm
Front Panel
RF connectors SMA (female)
Test ports 38 ports
Important: Test port damage level: +27 dBm or +/-35 VDC.
Important: Transmission/reflection uncertainty and dynamic accuracy specifications apply to units with serial number prefix MY552/SG552 and above. Units with serial number MY551/SG551 and below require a recalibration with TME N7842A E.05.00 and above.
Important: A third-wire ground is required for the AC line power connection.
Important: Calibration of the E5080A is performed using a separate calibration kit or ECal module (this data sheet specifies the 85032F and 85033E calibration kits and the 85092C and 85093C ECal modules); these are not part of the analyzer and must be ordered separately to make corrected (error-corrected) measurements.
Important: Test port output power level accuracy can be improved by performing power calibration using an external power meter.
Recommended pairing: the E5092A Configurable Multiport Test Set (50 MHz to 20 GHz, 38 test ports) connects to the E5080A over USB to extend measurements to multiport configurations.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Pre-Owned

Manufacturer

Keysight Technologies

E5080A Agilent Network Analyzer Used

E5080A

Keysight E5080B ENA Series Vector Network Analyzer, 9 kHz to 53 GHz, 2/4-port (Pre-Owned)

E5080B

Agilent E5071C ENA Network Analyzer, Option 240 (2-Port, 9 kHz to 4.5 GHz, without Bias Tees) (Pre-Owned)

E5071C