Key Features At A Glance

  • Frequency coverage from 9 kHz to 26.5 GHz, extendable to 325 GHz with external mixing (Option AYZ)
  • Phase noise of -101 dBc/Hz at 10 kHz offset, -122 dBc/Hz at 100 kHz, and -136 dBc/Hz at 1 MHz (typical, all carrier frequencies ≤6.7 GHz)
  • Displayed average noise level down to -166 dBm with RF preamplifier (typical)
  • Third order intermodulation distortion of +16 dBm TOI (typical, 100 MHz to 3 GHz)
  • ±0.4 dB absolute amplitude accuracy at reference settings (typical, 95% confidence with Option 1D5)
  • Resolution bandwidth from 1 Hz to 5 MHz with Options 1DR and 1D5; standard range 1 kHz to 5 MHz
  • Three express analyzer configurations available: Basic (BAS), Standard (STD), and Communications Test (COM)
  • GPIB (Option A4H), RS-232 (Option 1AX), and parallel printer interfaces for automated test integration
Share on
View full details

The Agilent E4407B is the top-frequency member of the ESA-E Series of mid-performance spectrum analyzers, covering 9 kHz to 26.5 GHz in its standard and communications test analyzer configurations. The ESA family is designed to deliver proven and guaranteed performance with the flexibility to select the right level of functionality for a given test need, and is offered in three express configurations — Basic, Standard, and Communications Test — to match the instrument to the application.

The datasheet positions the ESA Series for general-purpose RF and microwave spectrum measurement, with the E4407B specifically covering frequencies through K-band. Custom configuration with the low frequency extension (Option UKB) extends the lower frequency limit to 100 Hz, and external mixing (Option AYZ) extends coverage from 18 GHz up to 325 GHz, enabling measurements well into the millimeter-wave range for harmonic mixing applications.

ValueTronics has specialized in test and measurement equipment since 1992. Every {{CONDITION}} ESA-E Series analyzer in our inventory is processed through our 20,000 square foot facility at 1675 Cambridge Drive in Elgin, Illinois, where instruments are catalogued, inspected, and verified before shipping. Working through ValueTronics — rather than a drop-shipper or pass-through broker — means the analyzer you order has been physically handled and confirmed by our team prior to leaving the warehouse.

Brand Heritage

Agilent Technologies was spun off from Hewlett-Packard in 1999 as the dedicated test and measurement company; in 2014, Agilent's electronic measurement business was further separated to form Keysight Technologies, which is the current corporate home for the ESA Series product line and its associated support, calibration, and documentation infrastructure.

Compare Other Models in This Series

The ESA-E Series is offered in five frequency models — E4402B (3 GHz), E4404B (6.7 GHz), E4405B (13.2 GHz), E4407B (26.5 GHz), and the basic E4411B/E4403B/E4408B variants — covering general-purpose spectrum measurement from 9 kHz through K-band. The datasheet groups these into three express configurations: Basic Analyzer (Option BAS), Standard Analyzer (Option STD), and Communications Test Analyzer (Option COM), with custom configuration available to add narrow RBW, precision frequency reference, tracking generator, EMI bandwidths, and external mixing capabilities.

Within the standard and communications test configurations, the primary differentiation across models is upper frequency limit. The E4407B at 26.5 GHz provides the widest coverage of any single ESA-E model and is the only member that supports the 18 GHz to 325 GHz external mixing extension through Option AYZ. All standard/COM models share the same RBW range, amplitude range, trace memory, and connectivity baseline.

Each pre-owned ESA-E model is listed as its own product page with condition-matched pricing. The links below take you to the specific frequency variant for direct comparison of inventory and current availability.

The E4407B is the 26.5 GHz model in the standard and communications test analyzer configurations of the ESA-E Series. It is the only ESA-E model where Option AYZ external mixing extends the usable frequency range from 18 GHz to 325 GHz, making it the appropriate choice in the family when measurement requirements approach or exceed K-band, or when harmonic mixing into the millimeter-wave region is required.

The ESA-E Series models differ primarily in upper frequency coverage. The E4402B covers to 3 GHz, E4404B to 6.7 GHz, E4405B to 13.2 GHz, and E4407B to 26.5 GHz, with all four sharing the same core architecture, RBW range, trace memory, sweep capabilities, and rear-panel I/O. Within the basic analyzer line, the E4411B covers to 1.5 GHz, the E4403B to 3 GHz, and the E4408B to 26.5 GHz.

Specific amplitude and phase noise performance varies by frequency band — for example, displayed average noise level on the E4407B is typical -132 dBm at 22 to 26.5 GHz versus typical -140 dBm at 1.5 to 2 GHz — reflecting the higher mixing harmonics required to reach upper-band coverage. The comparison table that follows shows the specific frequency, configuration, and option differences across the family at a glance.

Model Frequency Range Phase Noise (10 kHz offset) DANL (1 GHz)
E4411B 9 kHz to 1.5 GHz -93 dBc/Hz (typ -95 dBc/Hz) -125 dBm (typ -130 dBm)
E4403B 9 kHz to 3 GHz -90 dBc/Hz (typ -94 dBc/Hz) -125 dBm (typ -130 dBm)
E4408B 9 kHz to 26.5 GHz -90 dBc/Hz (typ -94 dBc/Hz) -124 dBm (typ -129 dBm)
E4402B 9 kHz to 3 GHz -98 dBc/Hz (typ -101 dBc/Hz with Opt. 1D5) -136 dBm (typ -140 dBm)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
Frequency
Frequency reference aging rate (Basic analyzer) ±2 x 10-6/year
Frequency reference aging rate (Standard analyzer) ±2 x 10-6/year; ±1 x 10-7/year (Opt. 1D5)
Frequency reference aging rate (Communications test analyzer or ESA with Opt. 1D5) ±1 x 10-7/year
External reference (Basic / Standard) 10 MHz
External reference (Communications test analyzer) 1 – 30 MHz
Marker frequency counter resolution Selectable from 1 Hz to 100 kHz
Frequency span range 0 Hz (zero span), 100 Hz to maximum frequency range of the analyzer
Sweep time and trigger
Sweep time range, Span = 0 Hz (Basic analyzer) 4 ms – 4000 s
Sweep time range, Span = 0 Hz (Standard analyzer or ESA with Opt. AYX) 50 ns – 4000 s (RBW ≥ 1 kHz, 2 sweep points)
Sweep time range, Span = 0 Hz (Communications test analyzer or ESA with Opt. B7D/B7E) 25 ns – 4000 s
Sweep time range, Span ≥ 100 Hz (Basic analyzer) 4 ms – 4000 s
Sweep time range, Span ≥ 100 Hz (Standard / Communications) 1 ms – 4000 s
Sweep time accuracy (Span = 0 Hz) ± 1%
Trigger types Free Run, Single, Line, Video, Offset, Delayed, External
Delayed trigger range 1 us to 400 s
Sweep points range (Basic analyzer) 401
Sweep points range (Standard / Communications, Span = 0 Hz) 2 – 8192
Sweep points range (Standard / Communications, Span ≥ 100 Hz) 101 – 8192
Resolution bandwidths (1-3-10 sequence)
Basic / Standard analyzer range (-3 dB) 1 kHz – 5 MHz
Communications test analyzer range (-3 dB) 1 Hz to 5 MHz
EMI bandwidths (-6 dB) 9 kHz, 120 kHz (Basic/Standard); 200 Hz, 9 kHz, 120 kHz (Communications)
RBW accuracy 1 Hz to 300 Hz ± 10%
RBW accuracy 1 kHz to 3 MHz ± 15%
RBW accuracy 5 MHz ± 30%
Selectivity (60 dB/3 dB ratio), 100 Hz to 300 Hz < 5:1 digital, approximately Gaussian
Selectivity (60 dB/3 dB ratio), 1 kHz to 5 MHz < 15:1 synchronously tuned four poles, approximately Gaussian
Video bandwidths range 30 Hz to 3 MHz; adds 1, 3, 10 Hz for RBWs less than 1 kHz (with Opt. 1DR)
Amplitude
Measurement range Displayed average noise level (DANL) to maximum safe input level
Maximum safe input, Average continuous power +30 dBm (1 W) at input attenuator ≥ 5 dB (10 dB E4411B) / 30 dB peak pulse
Maximum safe input, Peak pulse power +50 dBm (100 W), < 10 us pulse width, < 1% duty cycle
Maximum safe DC voltage (AC coupled) 100 Vdc (50 Vdc with Opt. UKB on certain models)
1 dB gain compression (50 MHz to 6.7 GHz) 0 dBm at input mixer
1 dB gain compression (6.7 GHz to 13.2 GHz) -3 dBm at input mixer
1 dB gain compression (13.2 GHz to 26.5 GHz) -5 dBm at input mixer
Display range 0.1, 0.2, 0.5 dB/division and 1 to 20 dB/division in 1 dB steps (10 display divisions)
Reference level range –149.9 dBm to maximum mixer level + attenuator setting
Reference level resolution (Log scale) ±0.1 dB
Trace detectors Peak, negative peak, sample, rms, video averaging
Trace functions Clear/write, max hold, min hold, view, blank, operations, normalize
Scale units (Basic analyzer) dBm, dBmV, dBµV, dBµA, A, V, and W
Scale units (Standard / Communications) dBm, dBmV, dBµV, dBµA, A, V, W and Hz (with Opt. BAA or AYQ)
General
Operating temperature 0 °C to +55 °C
Storage temperature −40 °C to +75 °C
Disk drive operating temperature 10 °C to +40 °C
EMI compatibility CISPR Pub. 11/1990 Group 1 Class A (Class B with Option 060)
Audible noise (sound pressure at 25 °C) < 40 dBa pressure and < 4.6 bels power (ISODP7779)
Military specifications Type tested to MIL-PRF-28800F class 3
AC power input 90 to 132 V rms, 47 to 440 Hz; 195 to 250 V rms, 47 to 66 Hz; < 300 W
Standby power < 5 W
DC operation 12 to 20 Vdc, < 200 W power consumption
Internal data storage (nominal) 200 traces or states / 8.0 MB
External data storage 3.5″ 1.44 MB, MS-DOS
Display resolution 640 x 480
Width to outside of instrument handle 416 mm (16.4 in.)
Overall height 222 mm (8.75 in.)
Depth from front frame to rear frame 409 mm (16.1 in.)
Depth with instrument handle rotated horizontal 516 mm (20.3 in.)
Inputs / Outputs (Front Panel)
RF Input 50 Ω type N (f); 75 Ω BNC (f) (Opt. 1DP); 50 Ω APC 3.5 (m) (Opt. BAB)
RF Output 50 Ω type N (f); 75 Ω BNC (f) (Opt. 1DQ)
Probe power +15 Vdc, -12.6 Vdc at 150 mA maximum (characteristic)
External keyboard 6-pin mini-DIN, PC keyboards
Important: Maximum safe input level: +30 dBm (1 W) average continuous power and +50 dBm (100 W) peak pulse power (≤10 μs pulse width, ≤1% duty cycle), at input attenuator settings ≥5 dB average and ≥30 dB peak pulse power. AC-coupled DC voltage limit: 50 Vdc.Important: The analyzer must be within the one-year calibration cycle to meet its published specifications.Important: Specifications apply over the 0 °C to 55 °C operating temperature range unless otherwise noted; typical performance is characterized over 20 °C to 30 °C.Important: Option 1DR is required for phase noise measurements at frequency offsets of 10 kHz and less. Performance at the 10 kHz offset without Option 1DR is –90/–94 dBc/Hz.Important: For Option AYQ Quasi-Peak Detector, Option 1DR is also required.Important: For ordering options, refer to the ESA/EMC Spectrum Analyzer Configuration Guide, literature number 5968-3412E.Recommended pairing: Option 1DN tracking generator (9 kHz to 3 GHz on the E4407B) enables scalar network analysis of filters, amplifiers, and other components when paired with the spectrum analyzer's frequency-swept measurement capability.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent

Frequency

1.5 GHz

44

Yellow spectrum analyzer backpack

49

Color Display

60

Low emissions shielding

106

Bluetooth FSK demodulator

120

ACPR dynamic range extension

1AX

Serial Interface

1D5

High Stability Frequency Reference

1D6

Time-gated spectrum analysis

1DN

Tracking generator

1DP

75 OHM INPUT (E4411B)

1DR

Narrow resolution bandwidths

1DS

Preamp

219

Noise Figure

226

Phase Noise

228

Bluetooth measurement personality

229

Modulation Analysis

231

ESA to 89601A VSA software link

252

EDGE UPGRADE TO GSM MEASUREMENT PERSONALITY

535

Type N Input Connector

A4H

GPIB and Centronics interface

A4J

IF and sweep ports

AYQ

EMI DETECTORS AND FM DEMODULATION

AYX

Fast time-domain sweep

AYZ

External Mixing

B72

Enhanced Memory Upgrade

B74

RF/Digital communication hardware

B75

Performance Bundle (1D5+1DR+1DS)

B7D

Digital Signal Processing and Fast ADC

B7E

RF Communications Hardware

BAA

FM Demodulation

BAC

cdmaOne Measurement Personality

BAH

GSM/GPRS measurement personality

BAS

Includes IF/sweep port (A4J) and GPIB connection (A4H)

COM

COMMUNICATIONS TEST ANALYZER (B7D/B7E/1D5/1DR/BAA/231)

STD

10 Hz , 100 Hz , 1 kHz , 10 kHz , 100 kHz , 1 MHz

STG

Standard analyzer with tracking generator (1DN , AYX , BAA)

UKB

100 Hz low frequency extension