The Keysight E36200 Series is a family of autoranging bench DC power supplies built to deliver 200 to 400 W of power on the bench. The series comprises four models: the single-output E36231A (30 V, 20 A, 200 W) and E36232A (60 V, 10 A, 200 W), and the dual-output E36233A (30 V, 20 A, 400 W) and E36234A (60 V, 10 A, 400 W). Autoranging technology gives the highest current available at all output voltages within a model's rating, so a single supply covers a wider combination of voltage and current settings than a fixed-range design.
A DC power supply provides controlled, regulated electrical power to a device under test, letting an engineer set a precise voltage and current limit and power a circuit during design, characterization, or verification. The E36200 Series is intended for bench applications that require power up to 400 W. A single-output supply can power a device requiring less than 200 W, while the dual-output models can power two devices simultaneously or power multiple analog and digital circuitries from one instrument.
ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, which lets us support both new and used test-and-measurement equipment from one location. That combination of held inventory and hands-on verification on used equipment is how we help engineers and labs get the right instrument in known condition.
Keysight Technologies traces its roots to the test-and-measurement business of Hewlett-Packard, which was spun off as Agilent Technologies in 1999. That measurement business was then established as Keysight Technologies in 2014, the brand under which this product line is offered today.
The Keysight E36200 Series is a family of autoranging bench DC power supplies offered in four models that share a common architecture but differ in output ratings and the number of outputs. The E36231A and E36232A are single-output 200 W supplies, while the E36233A and E36234A are dual-output 400 W supplies. Across the family, autoranging technology provides the highest available current at all output voltages within each model's rating.
All four models share the same core capabilities: low output ripple and noise, 2-wire and 4-wire sensing, OVP/OCP/OTP protection, a 4.3-inch LCD color display, data logging, LIST mode, and standard LAN and USB connectivity with optional GPIB. The choice between models comes down to the voltage and current envelope your application needs and whether you require one output or two.
Each new model in the E36200 Series is listed on its own dedicated product page with condition-matched pricing, so you can select the exact model and configuration your application requires. Use the comparison below to identify the right model, then open that model's page to see new-condition availability.
The models differ first by voltage and current envelope: the E36231A and E36233A provide 30 V at up to 20 A, while the E36232A and E36234A provide 60 V at up to 10 A. They also differ by output count and total power — the E36231A and E36232A are single-output 200 W supplies, while the E36233A and E36234A are dual-output 400 W supplies whose two outputs are independently controllable and fully isolated.
On the dual-output models, the two outputs can be combined in series or parallel from the front panel: the E36233A reaches 40 A in parallel mode and the E36234A reaches 120 V in series mode. The E36231A and E36232A are additionally code compatible with the E3633A and E3634A to assist migration. See the comparison table for the per-model voltage, current, power, and resolution figures.
| Model | Output Voltage | Output Current | Output Power |
|---|---|---|---|
| E36234A | 60 V | 10 A | 400 W |
| E36231A | 30 V | 20 A | 200 W |
| E36232A | 60 V | 10 A | 200 W |
| E36233A | 30 V | 20 A | 400 W |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Performance Specifications | |
| Power output | 400 W |
| Channels | 2 |
| DC output rating (0 to 40 ºC) — Channel 1 | 0 to 60 V, 0 to 10 A |
| DC output rating (0 to 40 ºC) — Channel 2 | 0 to 60 V, 0 to 10 A |
| Series mode voltage | 120 V |
| Parallel mode current | 20 A |
| Load regulation ± (% of output + offset) | |
| Voltage | < 0.01% +2 mV |
| Current | < 0.01% +250 µA |
| Line regulation ± (% of output + offset) | |
| Voltage | < 0.01% +2 mV |
| Current | < 0.01% +250 µA |
| Output ripple and noise (20 Hz to 20 MHz) | |
| Normal mode voltage, Vpp | < 3.5 mVpp |
| Output ripple and noise (20 Hz to 10 MHz) | |
| Normal mode voltage, Vrms | < 350 µVrms |
| Accuracy 12 months (23 ºC ± 5 ºC) | |
| Voltage | 0.03% +8 mV |
| Current | 0.1% +3 mA |
| Readback accuracy ± (% of output + offset) | |
| Voltage | 0.03% +8 mV |
| Current | 0.1% +3 mA |
| Low range current | 0.25% +80 µA |
| Load transient recovery time | |
| Voltage settling band | 15 mV |
| Time | < 50 µs |
| Resolution — Programming remote | |
| Voltage | 3 mV |
| Current | 0.5 mA |
| Resolution — Readback remote | |
| Voltage | 1.5 mV |
| Current | 0.5 mA |
| Low range current | 10 µA |
| Resolution — Programming front panel | |
| Voltage | 1 mV |
| Current | 1 mA |
| Resolution — Readback front panel | |
| Voltage | 1 mV |
| Current | 1 mA |
| Low range current | 1 µA |
| Output ripple and noise (20 Hz to 20 MHz) | |
| Normal mode current | < 1 mArms |
| Overvoltage protection (OVP) ± (% of output + offset) | |
| Programming accuracy | 0.2% +0.4 V |
| Activation time | |
| Overvoltage (OVP) | < 5 ms |
| Overcurrent (OCP) | < 5 ms |
| Command processing time | < 10 ms |
| Programming temperature coefficient per ºC (% of output + offset) | |
| Voltage | 0.01% +0.6 mV |
| Current | 0.01% +0.2 mA |
| Readback temperature coefficient per ºC (% of output + offset) | |
| Voltage | 0.01% +0.04 mV |
| Current | 0.01% +0.2 mA |
| Remote sense (maximum voltage in load lead) | 0.7 V |
| Up/down programming settling time to within 1% of total excursion | |
| Up full load | 50 msec |
| Up no load | 50 msec |
| Down full load | 30 msec |
| Down no load | 100 msec |
| Voltage slew rate | 50 ms to 20,000 sec for 0 to max V transition |
| Connectivity | |
| Interface capabilities (GPIB) | SCPI – 1999, IEEE 488.2 compliant interface |
| LXI Compliance | Class C |
| USB 2.0 | Requires Keysight IO Library version 17.2.208 and up |
| 10/100 LAN | Requires Keysight IO Library version 17.2.208 and up |
| Digital control characteristics | |
| Maximum voltage ratings | +16.5 VDC / -5 VDC between pins (pin 4 internally connected to chassis ground) |
| Pins 1 and 2 as fault output | Maximum low-level output voltage = 0.5V @ 4mA; Maximum low-level sink current = 4mA; Typical high-level leakage current = 1mA @ 16.5 VDC |
| Pins 1 – 3 as digital/trigger outputs (pin 4 = common) | Maximum low-level output voltage = 0.5V @ 4mA; 1V @ 50mA; 1.75V @ 100mA; Maximum low-level sink current = 100mA; Typical high-level leakage current = 0.8mA @ 16.5 VDC |
| Pins 1 – 3 as digital/trigger inputs and pin 3 as inhibit input (pin 4 = common) | Maximum low-level input voltage = 0.8V; Minimum high-level input voltage = 2V; Typical low-level leakage current = 2mA @ 0V (internal 2.2k pull-up); Typical high-level leakage current = 0.12mA @ 16.5 VDC |
| Data logger function | |
| Measurement interval | 200 ms to 60 sec with a maximum duration of 20,000 hours |
| Environmental conditions | |
| Operating environment | Indoor use, installation category II (for AC input), pollution degree 2 |
| Operating temperature range | 0 °C to 40 °C |
| Storage temperature | –20 to 70 °C |
| Relative humidity | 80%RH at temperature up to 40 ºC; non-condensing |
| Altitude | Up to 2000 meters |
| Electromagnetic compatibility | Compliant with EMC directive (2014/30/EU); IEC 61326-1:2012/EN 61326-1:2013 Group 1 Class A; Canada: ICES-001:2004; Australia/New Zealand: AS/NZS; South Korea KC mark |
| Safety | UL 61010-1 3rd edition, CAN/CSA-C22.2 No. 61010-1-12, IEC 61010-1:2010 3rd edition |
| Acoustic noise declaration | Sound pressure Lp <70 dB(A), at operator position, Normal Operation, According to EN 27779 |
| AC input | ~100 VAC – 240 VAC (± 10%), 50/60 Hz, 800 VA |
Important: Remote sense maximum voltage in load lead: 0.7 V.
Important: The E36200 Series ships standard with LAN (LXI) and USB interfaces; GPIB is an available option (Option E363GPBU, user-installable interface module).
Important: Low range current spec applies for ≤100 mA on the E36231A and E36233A, and ≤50 mA on the E36232A and E36234A; tested at constant voltage mode.
Important: Auto-series and auto-parallel operation on the dual-output models internally combines the two outputs to double the rating: up to 120 V (E36234A) in series mode and up to 40 A (E36233A) in parallel mode.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Keysight
Condition
Factory New
Manufacturer
Keysight Technologies
Dcsup_amps
10 A
Dcsup_volts
60 V
Dcsup_watts
400 W