Fluke Networks DSX2-8000QOI/GLD 2 GHz CableAnalyzer with Quad OLTS, Quad OTDR, Fiber Inspection, Wi-Fi and 1 Year Gold Support

Fluke Networks DSX2-8000QOI/GLD 2 GHz CableAnalyzer with Quad OLTS, Quad OTDR, Fiber Inspection, Wi-Fi and 1 Year Gold Support

Regular price $48,090.63
Sale price $48,090.63 Regular price $0
Shipping calculated at checkout.
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Fluke Networks DSX2-8000QOI/GLD 2 GHz CableAnalyzer with Quad OLTS, Quad OTDR, Fiber Inspection, Wi-Fi and 1 Year Gold Support

Key Features At A Glance

  • Certifies twisted-pair cabling for deployments up to 40 Gigabit Ethernet across Cat 5e, 6, 6A, 8 and Class C, D, E, EA, F, FA, I/II
  • Cat 6A/Class EA Autotest in 8 seconds (DSX-8000) or 10 seconds (DSX-5000); Cat 8 Autotest in 16 seconds on DSX-8000
  • Compliant with ANSI/TIA-1152-A Level 2G and proposed IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
  • 5.7 in projected-capacitance touchscreen with Taptive user interface for setup, results review, and graphical fault analysis
  • Internal memory holds approximately 12,000 Cat 6A test results with full graphics (DSX-5000 and DSX-8000)
  • Integrated dual-band Wi-Fi (2.4 GHz and 5 GHz, IEEE 802.11 a/b/g/n) for uploading results to LinkWare Live cloud service
  • Supports TCL and ELTCTL balance measurements compliant with IEC 61935-1-1 (Draft), plus Resistance Unbalance per IEEE 802.3bt, ANSI/TIA/EIA-568, and ISO/IEC 11801
  • Shield integrity check reports distance to shield faults, not just DC continuity — critical for screened Cat 8 installations
View full details

The Fluke Networks DSX CableAnalyzer Series is the copper certification module of the Versiv cabling certification platform. Two modules anchor the series: the DSX-8000, which certifies twisted-pair cabling up to Cat 8 and Class I/II at 2000 MHz, and the DSX-5000, which certifies up to Cat 6A and Class FA at 1000 MHz. Both modules share the Versiv main unit, the Taptive touchscreen interface, the ProjX management system, and the LinkWare PC and LinkWare Live software ecosystem.

The DSX is built for cabling contractors and network installers who certify structured copper plants against TIA and ISO/IEC standards. Listed applications include certification of horizontal and backbone cabling for network deployments up to 40 Gigabit Ethernet, Modular Plug Terminated Link (MPTL) certification using a patch cord adapter on one end and a permanent link on the other, integrated Alien Crosstalk measurement up to 40GBASE-T, and balance measurements (TCL and ELTCTL) that matter most in industrial environments where electromagnetic interference is elevated. The DSX-8000 is the only DSX module that handles Cat 8 and Class I/II at 2 GHz; the DSX-5000 covers everything through Cat 6A and Class FA at 1 GHz.

Brand Heritage

Fluke Networks is the network cabling and certification division within the Fluke Corporation family of test and measurement brands. Fluke Corporation has been part of Fortive Corporation since Fortive's 2016 spin-off from Danaher. Fluke Networks operates as a focused brand for cable certification, network testing, and installation tools, distinct from Fluke's industrial DMM and process instrument lines.

Compare Other Models in This Series

The DSX CableAnalyzer Series consists of two copper certification modules built on the shared Versiv main unit platform: the DSX-8000 and the DSX-5000. Both modules use the same 5.7 in capacitive touchscreen, the same Taptive user interface, the same ProjX project-management system, the same LinkWare PC and LinkWare Live software, and the same lithium-ion battery and chassis. The difference between the two modules is frequency range and the standards each can certify.

Fluke Networks documents the DSX-8000 as the 2 GHz module supporting Cat 5e, 6, 6A, Cat 8, and Class I/II certification. The DSX-5000 is documented as the 1 GHz module supporting Cat 5e, 6, 6A, and Class FA certification. The DSX-8000 is the choice when Cat 8 / Class I/II certification is required; the DSX-5000 is the choice when the job ceiling is Cat 6A / Class FA and the 1 GHz range is sufficient.

Each new DSX module below is its own product page with condition-matched pricing and the appropriate Channel and Permanent Link adapter set for its frequency range. Add-on kits, remote units, and adapter accessories are listed separately in the ordering tables — verify the specific adapter set and accessory needs for your job before ordering.

The differences between the DSX-8000 and DSX-5000 reflect their certification ceilings. The DSX-8000 runs Cat 6A/Class EA Autotest in 8 seconds and Cat 8 Autotest in 16 seconds; the DSX-5000 runs Cat 6A/Class EA Autotest in 10 seconds. Both store approximately 12,000 Cat 6A results with plots; the DSX-8000 additionally stores about 5,000 Cat 8 results with plots. Both support Resistance Unbalance, shield integrity check with distance to fault, TCL, ELTCTL, CDNEXT, CMRL, and built-in Alien Crosstalk capability.

The adapter sets differ in frequency rating. DSX-8000 ships with 2 GHz Channel and Permanent Link adapters; DSX-5000 ships with 1 GHz Channel and Permanent Link adapters. Both modules accept optional Coax, M12, TERA, GG45/ARJ45, and Cat 5e/6/6A patch-cord adapters for MPTL certification. See the comparison table that follows for the side-by-side feature-by-feature view.

Model Max Frequency Cat 6A Test Time Cat 8 Test Time
DSX2-8000QOI/GLD 2000 MHz 8 seconds 16 seconds
DSX2-8000 2000 MHz 8 seconds 16 seconds
DSX2-8000/GLD 2000 MHz 8 seconds 16 seconds
DSX2-8000MI 2000 MHz 8 seconds 16 seconds

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Category Specification Value
Cable Types Shielded and unshielded pair LAN cabling TIA Cat 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard Link Interface Adapters Permanent link adapters Plug type: shielded RJ45; Optional Plug type: ARJ45/GG45
Standard Link Interface Adapters Channel Adapters Jack type: shielded RJ45; Optional Jack type: Tera, GG45/ARJ45
Test Standards TIA Cat 3, 4, 5, 5e, 6, 6A, 8 per TIA 568 Series
Test Standards ISO/IEC Class C, D, E, EA, F, FA, I/II certification per ISO/IEC 11801 Series
Test Standards Maximum frequency DSX-8000: 2000 MHz; DSX-5000: 1000 MHz
General Autotest Time (DSX-8000) Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds; Cat 6A/Class EA: 8 seconds; Cat 8: 16 seconds
General Autotest Time (DSX-5000) Full 2-way Autotest of Cat 5e or 6/Class D or E: 9 seconds; Cat 6A/Class EA: 10 seconds
General Support test parameters Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT), Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL)
General Input protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
General Display 5.7 in LCD display with a projected capacitance touchscreen
General Case High impact plastic with shock absorbing overmold
General Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
General Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5 oz (1.28 kg)
General Main unit and remote Lithium ion battery pack, 7.2 V
General Typical battery life 8 hours
General Charge time Tester off: 4 hours to charge from 10% capacity to 90% capacity
General Languages supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
General Calibration Service center calibration period is 1 year
General Integrated Wi-Fi Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Environmental Operating Temperature 32°F to 113°F (0°C to 45°C)
Environmental Storage Temperature -22°F to +140°F (-30°C to +60°C)
Environmental Operating relative humidity (% RH without condensation) 0% to 90%, 32°F to 95°F (0°C to 35°C); 0% to 70%, 95°F to 113°F (35°C to 45°C)
Environmental Vibration Random, 2 g, 5 Hz-500 Hz
Environmental Shock 1 m drop test with and without module and adapter
Environmental Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Environmental Operating altitude 13,123 ft (4,000 m); 10,500 ft (3,200 m) with ac adapter
Environmental EMC EN 61326-1
Important: MPTL certification requires a Cat 5e, 6, or 6A patch-cord adapter on the patch-cord end and a Permanent Link adapter on the opposite end; the latest Versiv/DSX firmware is required to use the MPTL test limits.Important: Permanent link adapters and channel adapters are required to perform certification testing and must be selected to match the cable category and connector type being certified (e.g., DSX-PLA804S/DSX-CHA804S for Cat 8/Class I, DSX-PLA004S/DSX-CHA004S for Cat 6A/Class EA). Adapters are sold separately from the base tester unless purchased as part of a Professional Kit (PRO) configuration.Important: The latest version of the Versiv/DSX firmware is required to use the MPTL (Modular Plug Terminated Link) testing limits.Important: DSX2-8000-ADD-R, DSX2-8-CFP-Q-ADD/R, and DSX2-ADD-R add-on kits with V2 Remote are not compatible with the original Versiv main unit.Recommended pairing: combine the DSX module with CertiFiber Pro and OptiFiber Pro modules on the same Versiv main unit to certify copper, fiber loss, and fiber OTDR traces from a single tester — the Versiv Professional Kit (DSX2-8000-PRO) configuration listed in the ordering tables.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Fluke

Condition

New

Manufacturer

Fluke Networks