Keysight DSO6014L 100 MHz 4-Channel Low-Profile Oscilloscope (Pre-Owned)

Keysight DSO6014L 100 MHz 4-Channel Low-Profile Oscilloscope (Pre-Owned)

Calibrations
Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Keysight DSO6014L 100 MHz 4-Channel Low-Profile Oscilloscope (Pre-Owned)

Key Features At A Glance

  • 1U low-profile rack-mount package (4.45 cm / 1.75 inches) with 4 channels, conserving valuable system rack space
  • Bandwidth from 100 MHz to 1 GHz across the series (DSO6014L/6054L/6104L) with up to 4 GSa/s sample rate
  • Standard 8 Mpts MegaZoom III deep memory for capturing long, non-repeating signals while maintaining high sample rates
  • LXI Class C compliant with standard USB, LAN, and GPIB interfaces plus XGA video output for full system connectivity
  • Built-in Web browser control for remote setup, monitoring, and operation over the LAN interface
  • 8-bit vertical resolution extensible to 12 bits in high-resolution mode (at ≥ 50 µsec/div per datasheet)
  • 100% software compatible with InfiniiVision 6000A Series portable oscilloscopes for seamless R&D-to-manufacturing transition
  • Optional MSO upgrade adds 16 logic timing channels for mixed-signal analysis
Share on
View full details

The Keysight DSO6104L is a 1 GHz, 4-channel digital storage oscilloscope in the InfiniiVision 6000L Series, designed as a low-profile, high-density 1U (4.45 cm / 1.75 inch) rack-mount instrument. The 6000L Series is described by Keysight as the most space efficient and affordable LXI Class C compliant oscilloscope family, providing four analog channels in only 1U of rack space with side and rear air vents (no top or bottom vents) so other instruments can be mounted directly above or below. Rack mount brackets and rack rails are included standard with every unit.

The 6000L Series is purpose-built for automated test systems. Because it is 100% software compatible with the InfiniiVision 6000A Series portable oscilloscopes, engineers can develop test routines on the bench-top 6000A during R&D and then transition the same software unchanged to the system-optimized 6000L in manufacturing — saving cost and rack space by moving from a standard bench-top oscilloscope to a 1U oscilloscope without a display. The instrument supports easy system integration through an included IVI-COM driver, SCPI commands, and the Keysight I/O Library Suite, simplifying configuration even when the system includes instruments from other vendors.

Brand Heritage

Keysight Technologies traces its test and measurement heritage to Hewlett-Packard. HP spun off its test and measurement division as Agilent Technologies in 1999, and Agilent further separated its electronic measurement business as Keysight Technologies in 2014. Instruments such as the InfiniiVision 6000L Series carry forward this Hewlett-Packard through Agilent to Keysight engineering lineage.

Compare Other Models in This Series

The Keysight InfiniiVision 6000L Series consists of three 4-channel low-profile rack-mount oscilloscopes that share an identical 1U mechanical package, identical connectivity (USB, LAN, GPIB, XGA video output), and identical 8 Mpts of standard MegaZoom III deep memory. The three models differ primarily in analog bandwidth and corresponding sample rate, allowing system integrators to select the bandwidth tier required for their specific signals while maintaining a consistent rack form factor and software interface across all three.

All three models in the family are LXI Class C compliant, 100% software compatible with the InfiniiVision 6000A Series portable oscilloscopes, and share the same option set (MSO upgrade, Secure Environment Mode, protocol decode options, segmented memory, and mask testing). This commonality means a test system designed around any 6000L model can be upgraded or reconfigured to a different bandwidth tier without rewriting test software or changing rack layouts.

Each model below is its own dedicated product page with pre-owned-matched pricing. The comparison table that follows is provided to help you select the bandwidth tier that fits your application; once you identify the right model, click through to its individual page for pre-owned-specific availability, included accessories, and the formal quote process.

The DSO6104L is the highest-bandwidth model in the 6000L family, offering 1 GHz analog bandwidth with 4 GSa/s sample rate in half-channel mode (2 GSa/s per channel). Its time base extends to 500 psec/div, and at slower time bases the 8 Mpts of MegaZoom III deep memory enables 2 ms full-rate captures in single-channel mode at 4 GSa/s. Input impedance is selectable between 1 MΩ ± 1% || 14 pF and 50 Ω ± 1.5%, and the AutoProbe interface supports active and current probes with automatic probe sensing.

The three 6000L Series models differ across three correlated specifications: analog bandwidth (DSO6014L at 100 MHz, DSO6054L at 500 MHz, DSO6104L at 1 GHz), maximum sample rate (DSO6014L at 2 GSa/s; DSO6054L and DSO6104L at 4 GSa/s half-channel / 2 GSa/s each channel), and minimum time base setting (DSO6014L at 5 nsec/div, DSO6054L at 1 nsec/div, DSO6104L at 500 psec/div). Peak detection capability also differs: 1 nsec on the DSO6014L versus 250 psec on the DSO6054L and DSO6104L.

Input impedance options vary across the family as well. The DSO6014L provides 1 MΩ ± 1% || 11 pF input only (with four 50 Ω termination adapters supplied), while the DSO6054L and DSO6104L offer selectable 1 MΩ ± 1% || 14 pF or 50 Ω ± 1.5% input impedance. The DSO6054L and DSO6104L also include the AutoProbe interface for automatic probe identification. Refer to the comparison table for the complete side-by-side specification view.

Model Bandwidth Analog Channels Max Sample Rate
DSO6014L 100 MHz 4 2 GSa/s
DSO6104L 1 GHz 4 4 GSa/s
DSO6054L 500 MHz 4 4 GSa/s

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • User's guide, service guide, programmer's guide
  • Power cord
  • Keysight IO Libraries Suite 14.2
  • Standard 3 year warranty
  • GPIB extender
  • 50 Ω termination adapter (four supplied)
  • Crossover LAN cable
  • Rack mount hardware

Product Core & Specifications

Specification DSO6014L DSO6054L DSO6104L
Scope Input
Analog Channels Ch 1, 2, 3 and 4 simultaneous acquisition
Bandwidth (-3 dB) DC to 100 MHz DC to 500 MHz DC to 1 GHz
Maximum Input CAT I 300 Vrms, 400 Vpk; CAT II 100 Vrms, 400 Vpk. With 10073C/10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk. 5 Vrms with 50 Ω input.
Full Scale Range 1 mV/div to 5 V/div (1 MΩ) 2 mV/div to 5 V/div (1 MΩ or 50 Ω) 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω)
Input Impedance 1 MΩ ± 1% || 11 pF 1 MΩ ± 1% || 14 pF or 50 Ω ± 1.5%, selectable 1 MΩ ± 1% || 14 pF or 50 Ω ± 1.5%, selectable
Coupling AC, DC
Offset Range ± 5 V on ranges < 10 mV/div; ± 25 V on ranges 10 mV/div to 200 mV/div; ± 75 V on ranges ≥ 200 mV/div
Connector BNC
BW Limit 20 MHz 25 MHz selectable 25 MHz selectable
Noise Peak-to-Peak 3% full scale or 2 mV, whichever is greater 3% full scale or 3.6 mV, whichever is greater 3% full scale or 4.5 mV, whichever is greater
Analog to Digital Conversion
Vertical Resolution 8 bits (extensible to 12 bits in High Resolution mode)
Sample Rate 2 GSa/s 4 GSa/s half channel, 2 GSa/s each channel 4 GSa/s half channel, 2 GSa/s each channel
Equivalent-Time Sample Rate 400 GSa/s (when realtime mode is turned off)
Standard Memory (2 ch / 4 ch) 8 Mpts / 4 Mpts
Time Range 5 nsec/div to 50 sec/div 1 nsec/div to 50 sec/div 500 psec/div to 50 sec/div
Acquisition
Acquisition Modes Normal, Peak Detect, Averaging, High Resolution
Peak Detection 1 nsec peak detect 250 psec peak detect 250 psec peak detect
Averaging Selectable from 2, 4, 8, 16, 32, 64… to 65536
Filter Sin x/x interpolation
Trigger System
Sources Ch 1, 2, 3, 4, line, ext and D0-D15 for MSO-enabled DSO
Modes Auto, Normal, Single
Holdoff Time Range ~60 ns to 10 seconds
Trigger Jitter 15 psec rms
Trigger Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I²C, SPI, Nth edge burst
Logic Channels (with MSO option)
Number of Channels 16 logic timing channels - labeled D15 - D0
Maximum Input Frequency 250 MHz
Logic Sample Rate 2 GSa/sec one pod, 1 GSa/sec each pod
Logic Memory Depth (1 pod / both pods) 8 Mpts / 4 Mpts
Threshold Selections TTL, CMOS, ECL, user-definable (selectable by pod)
Maximum Input Voltage (Logic) ± 40 V peak CAT I
Glitch Detection 2 ns (min pulse width)
External (EXT) Triggering
Input Resistance 1.015 kΩ ± 5% 2.14 kΩ ± 5% 2.14 kΩ ± 5%
Max Input ± 15 V
Range ± 5 V
Sensitivity DC to 100 MHz: 500 mV DC to 500 MHz: 500 mV DC to 500 MHz: 500 mV
FFT
Points Fixed at 1000 points
FFT Source Scope channels 1, 2, 3 or 4, 1+2, 1-2, 1x2
Window Rectangular, flattop, Hanning
Noise Floor -50 to -90 dB depending on averaging
Amplitude Display in dBV, dBm at 50 Ω
I/O
Standard Ports USB 2.0 high speed, 10/100-BaseT LAN, IEEE488.2 GPIB, XGA video output
Max Transfer (GPIB) 500 kbytes/sec
Max Transfer (USB) 3.5 Mbytes/sec (USBTMC-USB488)
Max Transfer (LAN) 1 Mbytes/sec (100 Mbps TCP/IP)
General Characteristics
Rack Mounting Supplied with all necessary hardware (except tools) for installation into a standard EIA 19-inch rack
Physical Size 43.5 cm W x 27 cm D x 4.2 cm H (without brackets)
Net Weight 2.45 kg (5.4 lbs.)
Shipping Weight 6.2 kg (13.6 lbs.)
Probe Comp Output ~1.2 kHz frequency, ~2.5 V amplitude
Power Requirements
Line Voltage Range 100 to 240 V, 50/60 Hz auto ranging
Power Usage 80 W max
Environmental Characteristics
Important: Maximum input: CAT I 300 Vrms, 400 Vpk; CAT II 100 Vrms, 400 Vpk. With 10073C/10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk. 5 Vrms with 50 Ω input.Important: The InfiniiVision 6000L Series is a low-profile, system-optimized oscilloscope without a built-in display. To view waveforms locally, connect an external XGA monitor to the rear-panel XGA video output, or use the built-in Web browser control over the LAN interface.Important: Passive probes are shipped standard with the DSO6054L and DSO6104L (10073C 10:1 500 MHz probe per scope channel) but are NOT included with the DSO6014L. Four 50 Ω termination adapters are supplied with the DSO6014L instead. Select appropriate probes from the recommended accessories list as required for the measurement application.Important: The MSO option requires an MSO upgrade kit (N2914A for DSO6014L, N2915A for DSO6054L/6104L), which includes a 54620-68701 logic cable kit, a label, and an upgrade key code to activate the MSO features.Important: All models include a standard 1-year warranty. Contact local sales office for prices of extended warranty and calibration options.Recommended pairing: the DSO6104L ships with one 10073C 10:1 500 MHz passive probe per scope channel. For high-frequency active probing the datasheet lists the 1156A 1.5 GHz active probe with AutoProbe interface as a compatible accessory.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Used

Manufacturer

Agilent

Channels

4

Frequency

100 MHz

Record length

2 MPts

Sampling rate

2 GS/s