Key Features At A Glance

  • Bandwidth options from 100 MHz to 500 MHz across the 5000 Series, with 2- or 4-channel configurations
  • MegaZoom III memory and display technology with up to 1 Mpts acquisition memory (half-channel mode)
  • Real-time waveform update rate up to 100,000 waveforms per second
  • 6.3-inch XGA (1024 x 768) color TFT display with 256 levels of intensity grading
  • Up to 12 bits of vertical resolution in high-resolution mode (single-shot, at timebase settings of 10 µs/div or slower)
  • Standard connectivity: 2 USB host ports, USB device port, 10/100 LAN, GPIB, and XGA video out — LXI Class C compliant
  • Built-in 5-digit hardware frequency counter on any channel, plus 23 automatic measurements with QuickMeas
  • AutoProbe interface auto-sets probe attenuation and powers selected Infiniium active probes including the 1130A and 1156A
Share on
View full details

The Agilent 5000 Series Portable Oscilloscopes are bench digital storage oscilloscopes built on Agilent's third-generation MegaZoom III memory and display architecture. The series spans six models covering 100 MHz, 300 MHz, and 500 MHz bandwidths in 2- or 4-channel configurations, delivering deep acquisition memory and high waveform update rates in a compact portable package. Each instrument combines a 6.3-inch XGA color display, comprehensive standard connectivity, and the same acquisition technology blocks used in Agilent's higher-performance bench and lab oscilloscopes.

The 5000 Series is positioned as an everyday bench oscilloscope for engineers and technicians who need to characterize known signal behavior and hunt down intermittent anomalies. Typical applications include circuit design verification, embedded systems debug, production test, and educational laboratory work. The series supports analog HDTV/EDTV triggering for standards including 1080i, 1080p, 720p, and 480p, as well as standard video triggering for NTSC, SECAM, PAL, and PAL-M signals, making it suitable for video and broadcast development work.

Brand Heritage

The Agilent 5000 Series was developed by Agilent Technologies, the test and measurement business that was spun out of Hewlett-Packard in 1999. In 2014, Agilent's electronic measurement business was further separated and renamed Keysight Technologies, which continues to support and service Agilent-era instruments including the 5000 Series. Buyers of Agilent-branded oscilloscopes are working with instruments whose technology and support lineage runs directly from HP through Agilent to Keysight.

Compare Other Models in This Series

The Agilent 5000 Series spans six oscilloscope models across three bandwidth tiers — 100 MHz, 300 MHz, and 500 MHz — with each bandwidth available in either a 2-channel or 4-channel configuration. All six models share the same MegaZoom III memory and display architecture, the same XGA display, the same standard connectivity package, and the same triggering and measurement feature set. The differentiating dimensions across the family are bandwidth, maximum sample rate, channel count, and peak detect resolution.

The series is structured so that an engineer can select the bandwidth and channel count appropriate to the application without losing access to the platform's core acquisition technology, software analysis features, or connectivity options. A buyer choosing a DSO5012A receives the same MegaZoom III deep memory architecture, the same 100,000 waveforms-per-second update capability, and the same LXI Class C connectivity as a buyer of the DSO5054A.

Each pre-owned 5000 Series model below is presented as its own dedicated product page with condition-matched pricing. Use the comparison table to identify the bandwidth, sample rate, channel count, and peak detect specification appropriate to your measurement requirement, then navigate to the corresponding model page for full specifications, condition details, and current availability.

The DSO5034A occupies the mid-range position in the 5000 Series with 300 MHz bandwidth, 2 GSa/s sample rate per channel, and 4 analog channels. It provides 500 ps peak detect for narrow glitch capture and a calculated rise time of 1.17 ns. The 4-channel configuration enables simultaneous observation of multiple signals — a common requirement in embedded systems debug where power rails, clock signals, and data lines must be viewed in time correlation.

The primary differentiators across the 5000 Series family are bandwidth (100, 300, or 500 MHz), channel count (2 or 4), and the resulting sample rate and peak detect characteristics. The 100 MHz models (DSO5012A, DSO5014A) deliver 2 GSa/s per channel with 1 ns peak detect. The 300 MHz models (DSO5032A, DSO5034A) deliver 2 GSa/s per channel with 500 ps peak detect. The 500 MHz models (DSO5052A, DSO5054A) deliver 4 GSa/s in half-channel mode and 2 GSa/s per channel, with 250 ps peak detect.

Memory depth scales the same way across all models: 1 Mpts in half-channel mode and 500 kpts per channel when both channels of a pair are active. Timebase range varies with bandwidth, extending down to 5 ns/div on the 100 MHz models, 2 ns/div on the 300 MHz models, and 1 ns/div on the 500 MHz models. All other specifications — display, connectivity, triggering, measurements, math functions, and FFT — are identical across the family. Refer to the comparison table for the per-model specification summary.

Model Bandwidth Channels Max Sample Rate
DSO5052A 500 MHz 2 4 GSa/s (half channel), 2 GSa/s each channel
DSO5012A 100 MHz 2 2 GSa/s
DSO5014A 100 MHz 4 2 GSa/s
DSO5032A 300 MHz 2 2 GSa/s

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • One 10073C 10:1 passive probe per channel
  • Power cord
  • Printed user's guide
  • Service guide (CD-ROM, English)
  • Certificate of Calibration
  • Declaration of Conformance
  • Protective front cover
  • Agilent IO Libraries

Product Core & Specifications

Acquisition
Sample Rate DSO501xA/503xA: 2 GSa/s each channel; DSO505xA: 4 GSa/s half channel, 2 GSa/s each channel
Equivalent-Time Sample Rate 400 GSa/s (when real-time mode is turned off)
Memory Depth 1 Mpts half channel, 500 kpts each channel
Vertical Resolution 8 bits, up to 12 in high-resolution or averaging modes
Peak Detection DSO501xA: 1 ns; DSO503xA: 500 ps; DSO505xA: 250 ps
Averaging Selectable from 2, 4, 8, 16, 32, 64 ... to 65536
High Resolution Mode Average mode with #avg = 1; 12 bits of resolution when ≥10 µs/div at 4 GSa/s or ≥20 µs/div at 2 GSa/s
Filter Sinx/x interpolation (single shot BW = sample rate/4 or bandwidth of oscilloscope, whichever is less)
Vertical System
Scope Channels DSO50x2A: 2 Ch simultaneous acquisition; DSO50x4A: 4 Ch simultaneous acquisition
Bandwidth (-3 dB) DSO501xA: DC to 100 MHz; DSO503xA: DC to 300 MHz; DSO505xA: DC to 500 MHz
AC Coupled DSO501xA: 3.5 Hz to 100 MHz; DSO503xA: 3.5 Hz to 300 MHz; DSO505xA: 3.5 Hz to 500 MHz
Calculated Rise Time DSO501xA: 3.5 nsec; DSO503xA: 1.17 nsec; DSO505xA: 700 psec
Single-Shot Bandwidth DSO501xA: 100 MHz; DSO503xA: 300 MHz; DSO505xA: 500 MHz
Range 2 mV/div to 5 V/div (1 MΩ or 50 Ω)
Maximum Input CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk. CAT II 100 Vrms, 400 Vpk. With 50 Ω input: 5 Vrms
Offset Range ±5 V on ranges < 10 mV/div; ±20 V on ranges 10 mV/div to 200 mV/div; ±75 V on ranges >200 mV/div
Dynamic Range ±8 div
Input Impedance 1 MΩ ± 1% || 12 pF or 50 Ω ± 1.0%, selectable
Coupling AC, DC
BW Limit 25 MHz selectable
Channel-to-Channel Isolation DC to max bandwidth > 40 dB
ESD Tolerance ±2 kV
Noise Peak-to-Peak DSO501xA: 3% full scale or 2.5 mV; DSO503xA: 3% full scale or 3 mV; DSO505xA: 3% full scale or 3.6 mV
DC Vertical Gain Accuracy ±2.0% full scale
DC Vertical Offset Accuracy ≤ 200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value; > 200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value
Horizontal
Range DSO501xA: 5 nsec/div to 50 sec/div; DSO503xA: 2 nsec/div to 50 sec/div; DSO505xA: 1 nsec/div to 50 sec/div
Resolution 2.5 psec
Timebase Accuracy 25 ppm (0.0025%) to 40° C, plus 1 ppm per ° C from 40° C to 55° C
Vernier 1-2-5 increments when off, ~25 minor increments between major settings when on
Delay Range Pre-trigger: Greater of 1 screen width or 125 µs; Post-trigger: 1 s to 500 seconds
Modes Main, delayed, roll, XY
Reference Positions Left, center, right
Trigger System
Sources DSO50x2A: Ch 1, 2, line, ext; DSO50x4A: Ch 1, 2, 3, 4, line, ext
Modes Auto, Normal (triggered), Single
Holdoff Time ~60 ns to 10 seconds
Trigger Jitter 15 ps rms
Selections Edge, pulse width, pattern, TV, duration
Display System
Display 6.3-inch (161 mm) diagonal color TFT LCD
Display Update Rate Up to 100,000 waveforms/sec in real-time mode
Resolution XGA: 768 vertical by 1024 horizontal points (screen area); 640 vertical by 1000 horizontal points (waveform area); 256 levels of intensity scale
Real-Time Clock Time and date (user adjustable)
Measurement Features
Voltage Measurements Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS, standard deviation
Time Measurements Frequency, period, +width, -width, duty cycle, rise time, fall time, X at max Y, X at min Y, delay, phase
Counter Built-in 5-digit frequency counter; counts up to oscilloscope's bandwidth
Waveform Math Subtract, multiply, FFT, differentiate, integrate
FFT Window Rectangular, flattop, hanning
I/O
Standard Ports USB 2.0 high speed device, two USB 1.1 host ports, 10/100-BaseT LAN, IEEE488.2 GPIB, XGA video output
Max Transfer Rate GPIB: 500 kbytes/sec; USB (USBTMC-USB488): 3.5 Mbytes/sec; 100 Mbps LAN (TCP/IP): 1 Mbytes/sec
Save/Recall 10 setups and traces in internal non-volatile memory
Image Formats BMP (8-bit), BMP (24-bit), PNG (24-bit)
Data Formats CSV, ASCII XY, BIN
General Characteristics
Physical Size 35.4 cm W x 18.8 cm H x 17.4 cm D (without handle); 38.5 cm W x 18.8 cm H x 17.4 cm D (with handle)
Weight Net: 4.1 kg (9 lbs); Shipping: approximately 9 kg (20 lbs)
Probe Comp Output ~1.2 kHz, Amplitude ~2.5 V
Important: Maximum sample rate of 4 GSa/s and maximum memory depth of 1 Mpts on the DSO505xA models are achieved only in half-channel mode (one channel of the channel pair turned on). Each channel delivers 2 GSa/s and 500 kpts when both channels of a pair are active.Important: Option SEC (Secure Environment Mode) is a factory-installed option only for new purchase; it is not retrofittable for existing 5000 Series scopes.Important: Maximum sample rate of 4 GSa/s and maximum memory of 1 Mpts on the DSO505xA models are achieved only when two channels are interleaved (half-channel mode).Important: Warranted specifications are valid after a 30-minute warm-up period and within ±10° C from firmware calibration temperature.Recommended pairing: the AutoProbe interface on the 5000 Series automatically configures and powers Agilent active probes such as the 1130A 1.5 GHz InfiniiMax differential probe and the 1156A 1.5 GHz single-ended active probe for high-bandwidth or differential signal work.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent

Channels

2

Frequency

500 MHz

Record length

8 MPts

Sampling rate