Fluke Calibration 8508A 8.5-Digit Reference Multimeter (Pre-Owned)

Fluke Calibration 8508A 8.5-Digit Reference Multimeter (Pre-Owned)

Calibrations
Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Fluke Calibration 8508A 8.5-Digit Reference Multimeter (Pre-Owned)

Key Features At A Glance

  • 8.5-digit resolution with exceptional linearity, low noise, and 365-day stability as low as 2.7 ppm (24-hour stability of 0.5 ppm)
  • DC voltage ranges from 200 mV to 1000 V with maximum sensitivity of 1 nV; AC voltage to 1 MHz bandwidth
  • DC current ranges from 200 µA to 20 A with maximum sensitivity of 10 pA; AC current to 100 kHz
  • Resistance ranges from 2 Ω to 20 GΩ with 10 nΩ sensitivity, 200 V compliance, and 100 mA measurement current
  • Temperature measurement via 2-, 3-, or 4-wire PRT/SPRT from -200 °C to 660 °C with ITS-90 and Callendar van Dusen linearization
  • IEEE 488 (GPIB) interface for automated test system integration
  • Optional dual front/rear input terminals for ratio measurements on voltage and resistance functions
  • Full analog measurement design — no auto-cal or self-calibration routines that compromise traceability
Share on
View full details

The Fluke 8508A Reference Multimeter is a metrology-grade digital multimeter engineered specifically for the demanding measurement needs of standards laboratories and calibration professionals. Featuring 8.5-digit resolution, the 8508A combines reference-standard accuracy with the functional versatility of a multifunction instrument, addressing three key performance pillars: accuracy and stability, functionality and versatility, and ease of use.

The 8508A supports a comprehensive set of measurement applications including DC and AC voltage, DC and AC current, resistance, temperature measurement via PRT/SPRT probes, and frequency measurement. With ratio measurement capability on voltage and resistance functions, the 8508A can replace Kelvin Varley dividers and AC/DC voltage transfer standards. It is well-suited to PRT calibration applications, multifunction calibrator verification, and precision component characterization — consolidating multiple specialized instruments into a single solution.

ValueTronics stocks and tests this Fluke 8508A Reference Multimeter in our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Unlike pass-through brokers and drop-shippers, every instrument is held in our facility, where our technicians perform functional verification before shipment. We have been a trusted source for precision test and measurement equipment since 1992, with a focus on metrology-grade instruments that demand careful handling and documented condition.

Brand Heritage

Fluke Calibration's heritage in precision measurement extends back to the founding of Fluke in 1948 by John Fluke. The company invented the digital multimeter and has built a long history in calibration metrology. In 2001, Fluke acquired Wavetek Precision Measurement of Norwich, UK, strengthening its position in DC and low-frequency precision measurement. The 8508A reflects this combined heritage of measurement expertise.

Compare Other Models in This Series

The Fluke 8508A is offered in two configurations as listed in the datasheet's ordering information. The base 8508A provides front-panel input terminals and the standard measurement function set. The 8508A/01 adds a duplicate set of rear binding posts and the ratio measurement package, enabling ratio measurements on voltage and resistance functions with the same current forced through both resistances.

Both configurations share identical core measurement performance — the same 8.5-digit resolution, the same DC and AC voltage and current ranges, the same resistance and temperature capabilities, and the same accuracy and stability specifications. The configuration choice is driven by whether ratio measurement and dual-terminal access are required for the intended application.

Each pre-owned 8508A configuration below is its own product page with condition-matched pricing and availability. Select the configuration that fits the measurement requirement — the base 8508A for standard precision multimeter applications, or the 8508A/01 when ratio measurements or rear-panel access are needed.

The principal difference between the two configurations is the inclusion of rear binding posts and the ratio measurement package in the 8508A/01. Rear-panel terminals are valuable in rack-mounted installations and automated test systems where front-panel access is impractical. The ratio measurement package enables direct voltage-to-voltage and resistance-to-resistance ratio measurements with reduced uncertainty contributions.

For applications requiring the replacement of Kelvin Varley dividers, AC/DC voltage transfer measurements, or precision resistance ratio measurements between two resistances, the 8508A/01 is the appropriate choice. For general metrology bench use where ratio measurements are not required, the base 8508A provides identical measurement performance through the front-panel terminals.

Model DC Voltage Range DC Current Range Resistance Range
8508A 200 mV to 1000 V 200 µA to 20 A 2 Ω to 20 GΩ
8508A/01 200 mV to 1000 V 200 µA to 20 A 2 Ω to 20 GΩ

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Parameter Specification
DC Voltage
Ranges 5 ranges, 200 mV to 1000 V
Maximum Measurement 1050 V
Resolution User selectable from 5.5 to 8.5 digits
Maximum Sensitivity 1 nV
Type Multi-slope, multi-cycle A-D Converter
CMRR (1 kΩ unbalance) 140 dB at DC and 1 – 60 Hz
NMRR (Filter Out) 60 dB at 50/60 Hz ± 0.09 %
NMRR (Filter In) 110 dB at 50/60 Hz ± 0.09 %
Protection (All ranges) 1 kV rms
Input Impedance (200 mV to 20 V Ranges) > 10 GΩ
Input Impedance (200 V & 1000 V Ranges) 10.1 MΩ ± 1 %
Max Input Current 50 pA
Settling Time (Filter Out, to 10 ppm step size) < 50 ms
Settling Time (Filter In, to 10 ppm step size) < 1 s
DC Current
Ranges 6 ranges, 200 µA to 20 A
Maximum Measurement 19.999000 A
Resolution User selectable from 5.5 to 7.5 digits
Maximum Sensitivity 10 pA
Type Multi-slope, multi-cycle A-D Converter
Protection (Front Input) 20 A rms
Protection (Rear Input) 2 A rms, Rear Panel Fuse
Settling Time Up to 200 mA range as DCV; 2 A range < 30 s to 75 ppm step size; 20 A range (at 10 A) < 30 s to 250 ppm step size
AC Voltage
Ranges 5 ranges, 200 mV to 1000 V
Resolution User selectable from 5.5 to 6.5 digits
Maximum Bandwidth 1 MHz
Maximum Sensitivity 100 nV
Type True RMS, AC coupled measures AC component with up to 1000 V DC bias on any range. DC coupled gives √(AC² + DC²)
CMRR (1 kΩ unbalance) > 90 dB DC – 60 Hz
Crest Factor (200 mV to 200 V ranges) 10:1 at 12 % of range, 5:1 at 50 % of range, 2.5:1 at full range
Crest Factor (1000 V range) 10:1 at 25 % of range, 5:1 at full range
Protection (All ranges) 1 kV rms
Input Impedance 1 MΩ in parallel with 150 pF
DC Accuracy (DC Coupled) Add ±(50 ppm Reading + 50 ppm Range + 20 µV)
AC Current
Ranges 6 ranges, 200 µA to 20 A
Resolution User selectable from 5.5 to 6.5 digits
Maximum Bandwidth 100 kHz
Maximum Sensitivity 100 pA
Type True RMS, AC coupled. DC coupled gives √(AC² + DC²)
Crest Factor 3:1 at 50 % of range, 1.5:1 at full range
Protection (Front Input) 20 A rms
Protection (Rear Input) 2 A rms, Rear Panel Fuse
Settling Time < 0.5 s to < 50 s, depending upon range and filter settings
Frequency Measurement
Signal Amplitude Range 5 % of range to limit set by maximum Volt·Hertz
Normal Gate Mode: Resolution 6.5 digits
Normal Gate Mode: Frequency Range 10 Hz – 1 MHz
Normal Gate Mode: Accuracy (1 year, 13 °C – 33 °C) ± (10 ppm of Reading + 2 digits)
Normal Gate Mode: Sample Interval 1 s
Fast Gate Mode: Resolution 4.5 digits
Fast Gate Mode: Frequency Range 200 Hz – 1 MHz
Fast Gate Mode: Accuracy (1 year, 13 °C – 33 °C) ± 2 digits
Fast Gate Mode: Sample Interval 50 ms
Resistance (Ohms)
Ranges 10 ranges, 2 Ω to 20 GΩ
Resolution User selectable from 5.5 to 8.5 digits
Maximum Sensitivity 10 nΩ
Maximum Compliance Voltage 200 V
Maximum Measurement Current 100 mA
Type True 4-wire with Ohms guard. 2-wire selectable
Max Lead Resistance 10 Ω in any or all leads, 1 Ω on 2 Ω range
Protection (All ranges) 250 V rms, 360 V pk
Settling Time Up to 200 kΩ range generally the same as DCV Filter In but depends on external connections
Temperature
Probe Support 2-wire, 3-wire and 4-wire PRT/SPRT with current reversal
Temperature Range -200 °C to 660 °C
Resolution User selectable from 5.5 to 8.5 digits
Linearization ITS-90 or Callendar van Dusen; entry and storage of coefficients and nominal resistance for up to 100 probes
Readout °C, °F, K or Ω
Current Source 1 mA
General — Power
Voltage 100 V to rms, designed for additional voltage fluctuations ±10 %
Frequency 50 Hz to 60 Hz, designed for additional frequency variation of ±3 %
Consumption 80 VA
Important: Maximum input transient rating: 1420 Vpk into measurement terminals (IEC 61010-1, Overvoltage CAT II, Pollution Degree 2). Maximum DC voltage input is 1 kV rms on all DCV ranges; current input protection is 20 A rms on the front input and 2 A rms (rear-panel fuse) on the rear input.Important: Specifications stated in this brochure reflect a 95 % confidence level (coverage factor k=2). Instrument performance is guaranteed at the 99 % confidence level. See the 8508A Extended Specifications or the instrument manual for full and complete specifications.Important: Specifications assume a 4 hour warm-up period.Important: Input zero or offset null is required whenever the temperature moves more than ±1 °C from the temperature at which the previous null/zero was performed.Important: Ratio measurement capability requires the 8508A/01 configuration, which includes both front and rear input binding posts and the ratio measurement package. The base 8508A does not include rear input terminals.Important: Measurement leads are not included with the base instrument. The 8508A-LEAD Comprehensive Measurement Lead Kit is ordered separately (see Accessories).Important: Temperature measurement requires a separately-ordered PRT or SPRT probe (e.g., 8508A-PRT or 8508A-SPRT); probes are not supplied with the instrument.Recommended pairing: the Fluke Calibration 5626 Platinum Resistance Thermometer or 5699 Standard Platinum Resistance Thermometer for temperature measurement and PRT calibration applications, both listed in the 8508A accessories.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Fluke

Condition

Used

Manufacturer

Agilent

1

Bail Handle and Front Protective Cover

50

Replace 85081B Input Module with 85082A Input Module

11570A

Accessory Kit (for measurement of 50 ½ systems with standard HP 8508A)

85081B

Input Module (100 kHz to 1 GHz , high-impedance probe inputs)

85082A

Input Module (300 kHz to 2 GHz , 50 ½ Type-N inputs)