Agilent 83631A Synthesized Source, 45 MHz to 26.5 GHz (Pre-Owned)

Agilent 83631A Synthesized Source, 45 MHz to 26.5 GHz (Pre-Owned)

Calibrations
Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Agilent 83631A Synthesized Source, 45 MHz to 26.5 GHz (Pre-Owned)

Key Features At A Glance

  • Frequency range from 45 MHz to 26.5 GHz with 1 Hz resolution
  • Maximum leveled output power of +10 dBm at frequencies up to 20 GHz
  • Maximum leveled output power of +4 dBm from 20 GHz to 26.5 GHz
  • Minimum settable output power of -20 dBm
  • CW mode frequency accuracy matches the internal time base
  • Swept mode accuracy of 0.1% of sweep width for sweep widths up to n x 10 MHz
  • Designed for use with the Agilent 8510 network analyzer system
Share on
View full details

The Agilent 83631A is a synthesized signal source covering 45 MHz to 26.5 GHz with 1 Hz frequency resolution. The instrument provides both CW and swept-mode operation across its full frequency range, with output power settable from -20 dBm to a maximum leveled level that varies with frequency band.

A synthesized source of this type serves as a stimulus instrument in RF and microwave measurement systems, generating known signals that are applied to a device under test so the response can be characterized by a companion receiver or analyzer. The 83631A is specified as part of the Agilent 8510 network analyzer system, where it provides the swept stimulus needed for S-parameter characterization of RF and microwave components across the instrument's frequency span.

Brand Heritage

Hewlett-Packard's test and measurement business was spun off as Agilent Technologies in 1999. In 2014, Agilent's electronic measurement business was transferred to Keysight Technologies, which is the current corporate successor for instruments originally produced under the Agilent brand.

Product Core & Specifications

Specification Value
Product Specifications
Specifications are the Agilent 8510 specifications, plus the following:
Range 45 MHz to 26.5 GHz
Resolution 1 Hz
Accuracy, CW Mode Same as time base
Accuracy, Swept Mode (Sweep Widths ≤n x 10 MHz) 0.1% of sweep width ±time base accuracy
Accuracy, Swept Mode (Sweep Widths >n x 10 MHz and ≤400 MHz) 1% of sweep width
Accuracy, Swept Mode (Sweep Widths >400 MHz and ≤4 GHz) 4 MHz
Accuracy, Swept Mode (Sweep Widths >4 GHz) 0.1% of sweep width
Output Power Specifications
Maximum Leveled (Frequencies ≤20 GHz) +10 dBm
Maximum Leveled (Frequencies >20 GHz and <26.5 GHz) +4 dBm
Minimum Settable -20 dBm
Important: Maximum leveled output power is frequency-dependent: +10 dBm at frequencies up to 20 GHz, +4 dBm from above 20 GHz through 26.5 GHz.Important: Specifications listed are the Agilent 8510 specifications, plus the additional specifications shown on this datasheet.Designed for use with the Agilent 8510 network analyzer system, where it provides the synthesized stimulus for swept S-parameter measurements across 45 MHz to 26.5 GHz.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent

Frequency

26.5 GHz