Fluke 5790A Automated AC Measurement Standard (Pre-Owned)

Fluke 5790A Automated AC Measurement Standard (Pre-Owned)

Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Fluke 5790A Automated AC Measurement Standard (Pre-Owned)

Key Features At A Glance

  • AC voltage measurement from 700 µV to 1000 V across a 10 Hz to 1 MHz frequency range
  • Absolute AC voltage measurement uncertainties as low as ±24 ppm (one year, 23 °C ±5 °C)
  • Patented Fluke Solid-State Thermal RMS Sensor with 2 V output for improved signal-to-noise and minimal reversal errors
  • Optional wideband measurement (Option -03) extends frequency coverage to 30 MHz
  • Compatible with Fluke A40 and A40A Current Shunts for AC/DC current transfer measurements up to 20 A
  • Four input connections (two Type-N, two sets of five-way binding posts) with front-panel input selection
  • Fully autoranging with 1200 V rms non-destructive input protection on all voltage ranges
  • IEEE-488 and RS-232 interfaces standard for automated system integration
Share on
View full details

The Fluke 5790A Automated AC Measurement Standard is a complete automated AC measurement standard designed for demanding calibration applications. It combines thermal-transfer-standard accuracy with the operating convenience of a digital multimeter, covering an alternating voltage range of 700 µV to 1000 V and a frequency range of 10 Hz to 1 MHz, with absolute AC voltage measurement uncertainties as low as ±24 ppm (one year, 23 °C ±5 °C).

The 5790A is designed to meet the complete AC voltage and wideband verification requirements of the Fluke 5700A, 5500A, and 5100 Series calibrators, amplifiers such as the 5725A and 5205A, and transfer standards and AC voltmeters. It is also compatible with the Fluke A40 and A40A Current Shunts, enabling AC/DC current transfer measurements up to 20 A. The instrument may be used alone or as a transfer standard with an external DC source, with switching and calculations performed automatically and the resulting AC/DC difference displayed directly on the vacuum fluorescent display.

Brand Heritage

Fluke Corporation, founded in 1948, is the long-established American test and measurement manufacturer best known for precision multimeters and calibration instruments. The Fluke metrology product line, including AC measurement standards and transfer instruments, has remained under continuous Fluke development. Fluke became part of Danaher Corporation in 1998, and in 2016 Fluke's industrial group was transferred to Fortive Corporation when Fortive was spun off from Danaher. The Fluke brand and engineering organization have been preserved throughout.

Product Core & Specifications

Specification Value
AC Voltage Range 700 µV to 1000 V
Frequency Range 10 Hz to 1 MHz
Wideband Frequency Range (Option -03) 10 Hz to 30 MHz
Best Absolute Uncertainty (1 year, 23°C ±5°C) ±24 ppm
Voltage Ranges 2.2 mV, 7 mV, 22 mV, 70 mV, 220 mV, 700 mV, 2.2 V, 7 V, 22 V, 70 V, 220 V, 700 V, 1000 V
Maximum Non-Destructive Input 1200 V rms
Guard Isolation 10 V peak
Volt-Hertz Product 1 x 10⁸
Input Connections Two Type-N connectors, two sets of five-way binding posts
Frequency Accuracy 10-120 Hz: 100 ppm + 10 digits; >120 Hz: 100 ppm + 2 digits (0°C to 50°C)
Reading Rate <40 Hz: 2 seconds per reading; 2 sec at 40 Hz decreasing linearly to 1 sec at 200 Hz; >200 Hz: 1 second per reading
Input Waveform Specified for sinewave with THD less than 1%
Shunt Input Resistance 91Ω ±1%
Shunt Operating Input Voltage 250 mV to 500 mV
Shunt Maximum Non-Destructive Input 50 V rms
Wideband Maximum Non-Destructive Input 200 V rms
Wideband Guard Isolation 0.5 V peak
Wideband Input Impedance 1 kHz: 50Ω (±0.5%); 30 MHz: 50Ω (±5%)
Wideband VSWR with 50Ω source 1 kHz: 1.005; 30 MHz: 1.05
Warm-up Time 30 minutes
Operating Temperature 0°C to 50°C
Calibration Temperature 15°C to 35°C
Storage Temperature -40°C to 70°C
Relative Humidity (Operating) 45% to 50°C; 75% to 45°C; 95% to 30°C
Storage Humidity <95% non-condensing
Operating Altitude 3,050 m (10,000 ft)
Non-operating Altitude 12,200 m (40,000 ft)
Line Power 47 Hz to 63 Hz; ±10% of selectable line voltages: 100V, 110V, 115V, 120V, 200V, 220V, 230V, 240V
Maximum Power (5790A) 95 VA
Maximum Power (with Wideband) 120 VA
Safety Designed to comply with UL3111; EN61010; CSA C22.2 No. 1010; ANSI/ISI S82.01-1994
EMI/RFI Complies with FCC Part 15 Subpart B, Class B; EN50081-1, EN50082-1
Remote Interfaces RS-232, IEEE-488
Dimensions (H x W x D) 17.8 cm (7 in) + 1.5 cm (0.6 in) x 43.2 cm (17 in) x 63 cm (24.8 in)
Weight (5790A) 24 kg (53 lb)
Weight (with Wideband) 24.5 kg (54 lb)
Important: Maximum non-destructive input is 1200 V rms on the standard measurement inputs and 200 V rms on the wideband input. Guard isolation is 10 V peak (0.5 V peak on the wideband input). Volt-hertz product is 1 × 10⁸. Specified for sinewave input with THD less than 1%.Important: The 792A-7004 A40 Current Shunt Adapter is not compatible with A40A Current Shunts. Use the 5790A-7001 A40/A40A Current Shunt Adapter and Cable for compatibility with both A40 and A40A Current Shunts.Important: Use of A40 or A40A Current Shunts for ac/dc current transfer measurements requires the 5790A-7001 A40/A40A Current Shunt Adapter and Cable (or 792A-7004 for A40 only). Current shunts are sold separately.Important: Absolute uncertainty specifications apply within ±5°C of calibration temperature. Add temperature coefficient to uncertainty when operating more than 5°C from calibration temperature.Important: Wideband flatness specifications: add to flatness specifications when more than 3°C from calibration temperature.Recommended pairing: traceability to national standards for the 5790A is supported through the Fluke 792A AC/DC Transfer Standard, which is also the recommended companion for the instrument's self-contained periodic performance verification procedure.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Fluke

Condition

Used

Manufacturer

Fluke

3

Wideband AC Measurement