Skip to content

The Keithley 2000 Series Scanners are plug-in scanner cards designed to install in the back-panel option slot of Keithley Model 2000, 2001, 2002, and 2010 digital multimeters. Three card variants are available: the 2000-SCAN general-purpose 10-channel card, the 2001-SCAN high-speed multiplexing card with solid-state channels, and the 2001-TCSCAN thermocouple/general-purpose card with built-in cold-junction reference.
These scanner cards transform a host multimeter into a multipoint test and measurement system suited to applications involving up to ten measurement points. Combining scan and measurement capabilities in a single instrument reduces the need for extra equipment, eliminates complexities of triggering, timing, and processing issues, and helps reduce test time. The 2001-TCSCAN supports cold-junction compensated temperature measurements alongside voltage, resistance, and frequency measurements on the same card.
ValueTronics International has supplied new and pre-owned test and measurement equipment from our Elgin, Illinois facility since 1992. Every {{CONDITION}} 2000 Series Scanner card we sell is inspected by our technical staff at our 20,000 square foot warehouse at 1675 Cambridge Drive before it leaves the building. Customers reach a live test equipment specialist by phone and receive the same instrument they were quoted — with the condition, accessories, and documentation confirmed in writing.
Keithley Instruments was founded in Cleveland, Ohio in 1946 and built its reputation on precision low-level electrical measurement instruments. Keithley was acquired by Danaher Corporation in 2010, joining Tektronix in the same portfolio. In 2016, Danaher's industrial businesses — including both Keithley and Tektronix — were spun off into Fortive Corporation, where the Keithley brand continues today.
The Keithley 2000 Series Scanners comprise three plug-in scanner cards — the 2000-SCAN, 2001-SCAN, and 2001-TCSCAN — that all install in the back-panel option slot of the Keithley Model 2000, 2001, 2002, and 2010 digital multimeters. The datasheet groups these three cards as a family because they share the same host-instrument compatibility, the same compact mechanical form factor, and the same screw terminal input architecture.
Within the family, each card targets a different measurement focus. The 2000-SCAN is the general-purpose 10-channel relay scanner. The 2001-SCAN adds two solid-state channels to enable high-speed ratio and delta measurements. The 2001-TCSCAN trades one channel for a built-in cold-junction reference to enable thermocouple temperature measurements alongside voltage, resistance, and frequency.
Each new 2000 Series Scanner card listed below is its own dedicated product page with condition-matched pricing. Click into the specific card variant that fits your application and host multimeter to see the current quote, accessories included, and availability.
The 2000-SCAN is the entry point in the family: 10 channels of 2-pole relay input, configurable as 5-channel 4-pole, suited to general-purpose multiplexing into the host multimeter without the solid-state speed enhancements or thermocouple reference of the other two cards.
The three cards differ in channel architecture and measurement capability. The 2000-SCAN provides ten 2-pole relay channels with no solid-state or thermocouple capability. The 2001-SCAN provides eight relay channels plus two solid-state channels, with the solid-state channels supporting DCV, ACV, and frequency measurements at faster actuation times (150 µs on / 100 µs off versus 2.5 ms for the relay channels). The 2001-TCSCAN provides nine analog channels plus a dedicated cold-junction reference channel for thermocouple work, with scan speeds up to 43 channels per second at 1°C resolution.
Function coverage also differs across the family. The 2001-SCAN relay channels handle DCV, ACV, 4-wire and 2-wire resistance, RTDs, frequency, and (on two channels with user-supplied shunt resistors) DCI and ACI. The 2001-SCAN solid-state channels are limited to DCV, ACV, and frequency. The 2001-TCSCAN supports DCV, ACV, 4-wire resistance, thermocouple, 2-wire resistance, 4-wire RTD, 2-wire RTD, and frequency — mixable channel to channel.
| Model | Channels | Switching Type | Signal Range |
|---|---|---|---|
| 2001-TCSCAN | 9 analog input + 1 cold-junction reference | Relay (2-pole) | 500nV to 125V |
| 2000-SCAN | 10 (2-pole), configurable as 5 (4-pole) | Relay (electromechanical) | Up to 110V DC / 125V AC rms, 1A |
| 2001-SCAN | 10 (8 relay + 2 solid-state) | Relay + Solid-State Hybrid | 500nV to 125V; 110V DC, 1A (relay); 50mA (solid-state) |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Parameter | Specification |
|---|---|
| Thermocouple Accuracy (Total Absolute Error, 1 Year, with Model 2001 Multimeter) | |
| Type J | Range: −100° to 760°C; Default Resolution: 0.1°C; 18°–28°C: ±0.65°C; 0°–18°C & 28°–50°C: ±1.08°C |
| Type K | Range: −100° to 1372°C; Default Resolution: 0.1°C; 18°–28°C: ±0.70°C; 0°–18°C & 28°–50°C: ±1.32°C |
| Type T | Range: −100° to 400°C; Default Resolution: 0.1°C; 18°–28°C: ±0.68°C; 0°–18°C & 28°–50°C: ±1.22°C |
| Type E | Range: −100° to 1000°C; Default Resolution: 0.1°C; 18°–28°C: ±0.67°C; 0°–18°C & 28°–50°C: ±1.11°C |
| Type R | Range: 0° to 1768°C; Default Resolution: 1.0°C; 18°–28°C: ±1.31°C; 0°–18°C & 28°–50°C: ±3.06°C |
| Type S | Range: 0° to 1768°C; Default Resolution: 1.0°C; 18°–28°C: ±1.30°C; 0°–18°C & 28°–50°C: ±3.02°C |
| Type B | Range: 350° to 1820°C; Default Resolution: 1.0°C; 18°–28°C: ±1.65°C; 0°–18°C & 28°–50°C: ±4.14°C |
| Accuracy Notes | Specifications apply to channels 2–6. Add 0.06°C for each adjacent channel away from channel 6. Extended range (Types J, K, T, E): −200.0°C to −100.1°C add ±0.1°C. Excluding thermocouple error. |
| General | |
| Channels | 9 channels of 2-pole analog input, 1 cold junction sensor |
| Functions | DCV, ACV, 4-wire Ω, Thermocouple, 2-wire Ω, 4-wire RTD, 2-wire RTD, Frequency (can be mixed from channel to channel) |
| Thermocouple Scan Speed | 25 channels/second @ 0.1°C resolution; 43 channels/second @ 1°C resolution |
| Capabilities | Multiplex one of nine 2-pole or one of four 4-pole analog signals into Model 2001 DMM and/or any combination of 2- or 4-pole analog signals |
| Reference Output | +200µV/°C (+54.63mV at 0°C) |
| All Inputs — Maximum Signal Levels | |
| DC | 110V DC, <1A switched, 30VA maximum (resistive load) |
| AC | 125V AC rms or 175V AC peak, 1A switched, 62.5VA maximum (resistive load) |
| Contact Life | >105 operations at maximum signal level; >108 operations cold switching |
| Contact Resistance | <1Ω at end of contact life (Channels 5 and 10 maximum power = 0.25 VA maximum — factory installed 120Ω, 5%, 1/4W resistors; user may replace with jumper) |
| Actuation Time | 2.5ms maximum on/off |
| Contact Potential | <±500nV typical per contact, 1µV max (Channels 5 and 10: ±1µV typical, 2µV max) |
| Connector Type | Screw terminal, #22 AWG wire size (0.062 O.D.) |
| Isolation Between Any Two Terminals | >109Ω, <75pF |
| Common Mode Voltage | 350V peak between any terminal and earth |
| Maximum Voltage Between Any Two Terminals | 110V DC, 125V AC rms |
| Physical | |
| Dimensions | 21mm high × 72mm wide × 221mm deep (0.83 in × 2.83 in × 8.7 in) |
| Net Weight | 283g (10 oz) |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.