Skip to content

The Agilent E4407B is the top-frequency member of the ESA-E Series of mid-performance spectrum analyzers, covering 9 kHz to 26.5 GHz in its standard and communications test analyzer configurations. The ESA family is designed to deliver proven and guaranteed performance with the flexibility to select the right level of functionality for a given test need, and is offered in three express configurations — Basic, Standard, and Communications Test — to match the instrument to the application.
The datasheet positions the ESA Series for general-purpose RF and microwave spectrum measurement, with the E4407B specifically covering frequencies through K-band. Custom configuration with the low frequency extension (Option UKB) extends the lower frequency limit to 100 Hz, and external mixing (Option AYZ) extends coverage from 18 GHz up to 325 GHz, enabling measurements well into the millimeter-wave range for harmonic mixing applications.
ValueTronics has specialized in test and measurement equipment since 1992. Every {{CONDITION}} ESA-E Series analyzer in our inventory is processed through our 20,000 square foot facility at 1675 Cambridge Drive in Elgin, Illinois, where instruments are catalogued, inspected, and verified before shipping. Working through ValueTronics — rather than a drop-shipper or pass-through broker — means the analyzer you order has been physically handled and confirmed by our team prior to leaving the warehouse.
Agilent Technologies was spun off from Hewlett-Packard in 1999 as the dedicated test and measurement company; in 2014, Agilent's electronic measurement business was further separated to form Keysight Technologies, which is the current corporate home for the ESA Series product line and its associated support, calibration, and documentation infrastructure.
The ESA-E Series is offered in five frequency models — E4402B (3 GHz), E4404B (6.7 GHz), E4405B (13.2 GHz), E4407B (26.5 GHz), and the basic E4411B/E4403B/E4408B variants — covering general-purpose spectrum measurement from 9 kHz through K-band. The datasheet groups these into three express configurations: Basic Analyzer (Option BAS), Standard Analyzer (Option STD), and Communications Test Analyzer (Option COM), with custom configuration available to add narrow RBW, precision frequency reference, tracking generator, EMI bandwidths, and external mixing capabilities.
Within the standard and communications test configurations, the primary differentiation across models is upper frequency limit. The E4407B at 26.5 GHz provides the widest coverage of any single ESA-E model and is the only member that supports the 18 GHz to 325 GHz external mixing extension through Option AYZ. All standard/COM models share the same RBW range, amplitude range, trace memory, and connectivity baseline.
Each pre-owned ESA-E model is listed as its own product page with condition-matched pricing. The links below take you to the specific frequency variant for direct comparison of inventory and current availability.
The E4407B is the 26.5 GHz model in the standard and communications test analyzer configurations of the ESA-E Series. It is the only ESA-E model where Option AYZ external mixing extends the usable frequency range from 18 GHz to 325 GHz, making it the appropriate choice in the family when measurement requirements approach or exceed K-band, or when harmonic mixing into the millimeter-wave region is required.
The ESA-E Series models differ primarily in upper frequency coverage. The E4402B covers to 3 GHz, E4404B to 6.7 GHz, E4405B to 13.2 GHz, and E4407B to 26.5 GHz, with all four sharing the same core architecture, RBW range, trace memory, sweep capabilities, and rear-panel I/O. Within the basic analyzer line, the E4411B covers to 1.5 GHz, the E4403B to 3 GHz, and the E4408B to 26.5 GHz.
Specific amplitude and phase noise performance varies by frequency band — for example, displayed average noise level on the E4407B is typical -132 dBm at 22 to 26.5 GHz versus typical -140 dBm at 1.5 to 2 GHz — reflecting the higher mixing harmonics required to reach upper-band coverage. The comparison table that follows shows the specific frequency, configuration, and option differences across the family at a glance.
| Model | Frequency Range | Phase Noise (10 kHz offset) | DANL (1 GHz) |
|---|---|---|---|
| E4411B | 9 kHz to 1.5 GHz | -93 dBc/Hz (typ -95 dBc/Hz) | -125 dBm (typ -130 dBm) |
| E4403B | 9 kHz to 3 GHz | -90 dBc/Hz (typ -94 dBc/Hz) | -125 dBm (typ -130 dBm) |
| E4408B | 9 kHz to 26.5 GHz | -90 dBc/Hz (typ -94 dBc/Hz) | -124 dBm (typ -129 dBm) |
| E4402B | 9 kHz to 3 GHz | -98 dBc/Hz (typ -101 dBc/Hz with Opt. 1D5) | -136 dBm (typ -140 dBm) |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Frequency | |
| Frequency reference aging rate (Basic analyzer) | ±2 x 10-6/year |
| Frequency reference aging rate (Standard analyzer) | ±2 x 10-6/year; ±1 x 10-7/year (Opt. 1D5) |
| Frequency reference aging rate (Communications test analyzer or ESA with Opt. 1D5) | ±1 x 10-7/year |
| External reference (Basic / Standard) | 10 MHz |
| External reference (Communications test analyzer) | 1 – 30 MHz |
| Marker frequency counter resolution | Selectable from 1 Hz to 100 kHz |
| Frequency span range | 0 Hz (zero span), 100 Hz to maximum frequency range of the analyzer |
| Sweep time and trigger | |
| Sweep time range, Span = 0 Hz (Basic analyzer) | 4 ms – 4000 s |
| Sweep time range, Span = 0 Hz (Standard analyzer or ESA with Opt. AYX) | 50 ns – 4000 s (RBW ≥ 1 kHz, 2 sweep points) |
| Sweep time range, Span = 0 Hz (Communications test analyzer or ESA with Opt. B7D/B7E) | 25 ns – 4000 s |
| Sweep time range, Span ≥ 100 Hz (Basic analyzer) | 4 ms – 4000 s |
| Sweep time range, Span ≥ 100 Hz (Standard / Communications) | 1 ms – 4000 s |
| Sweep time accuracy (Span = 0 Hz) | ± 1% |
| Trigger types | Free Run, Single, Line, Video, Offset, Delayed, External |
| Delayed trigger range | 1 us to 400 s |
| Sweep points range (Basic analyzer) | 401 |
| Sweep points range (Standard / Communications, Span = 0 Hz) | 2 – 8192 |
| Sweep points range (Standard / Communications, Span ≥ 100 Hz) | 101 – 8192 |
| Resolution bandwidths (1-3-10 sequence) | |
| Basic / Standard analyzer range (-3 dB) | 1 kHz – 5 MHz |
| Communications test analyzer range (-3 dB) | 1 Hz to 5 MHz |
| EMI bandwidths (-6 dB) | 9 kHz, 120 kHz (Basic/Standard); 200 Hz, 9 kHz, 120 kHz (Communications) |
| RBW accuracy 1 Hz to 300 Hz | ± 10% |
| RBW accuracy 1 kHz to 3 MHz | ± 15% |
| RBW accuracy 5 MHz | ± 30% |
| Selectivity (60 dB/3 dB ratio), 100 Hz to 300 Hz | < 5:1 digital, approximately Gaussian |
| Selectivity (60 dB/3 dB ratio), 1 kHz to 5 MHz | < 15:1 synchronously tuned four poles, approximately Gaussian |
| Video bandwidths range | 30 Hz to 3 MHz; adds 1, 3, 10 Hz for RBWs less than 1 kHz (with Opt. 1DR) |
| Amplitude | |
| Measurement range | Displayed average noise level (DANL) to maximum safe input level |
| Maximum safe input, Average continuous power | +30 dBm (1 W) at input attenuator ≥ 5 dB (10 dB E4411B) / 30 dB peak pulse |
| Maximum safe input, Peak pulse power | +50 dBm (100 W), < 10 us pulse width, < 1% duty cycle |
| Maximum safe DC voltage (AC coupled) | 100 Vdc (50 Vdc with Opt. UKB on certain models) |
| 1 dB gain compression (50 MHz to 6.7 GHz) | 0 dBm at input mixer |
| 1 dB gain compression (6.7 GHz to 13.2 GHz) | -3 dBm at input mixer |
| 1 dB gain compression (13.2 GHz to 26.5 GHz) | -5 dBm at input mixer |
| Display range | 0.1, 0.2, 0.5 dB/division and 1 to 20 dB/division in 1 dB steps (10 display divisions) |
| Reference level range | –149.9 dBm to maximum mixer level + attenuator setting |
| Reference level resolution (Log scale) | ±0.1 dB |
| Trace detectors | Peak, negative peak, sample, rms, video averaging |
| Trace functions | Clear/write, max hold, min hold, view, blank, operations, normalize |
| Scale units (Basic analyzer) | dBm, dBmV, dBµV, dBµA, A, V, and W |
| Scale units (Standard / Communications) | dBm, dBmV, dBµV, dBµA, A, V, W and Hz (with Opt. BAA or AYQ) |
| General | |
| Operating temperature | 0 °C to +55 °C |
| Storage temperature | −40 °C to +75 °C |
| Disk drive operating temperature | 10 °C to +40 °C |
| EMI compatibility | CISPR Pub. 11/1990 Group 1 Class A (Class B with Option 060) |
| Audible noise (sound pressure at 25 °C) | < 40 dBa pressure and < 4.6 bels power (ISODP7779) |
| Military specifications | Type tested to MIL-PRF-28800F class 3 |
| AC power input | 90 to 132 V rms, 47 to 440 Hz; 195 to 250 V rms, 47 to 66 Hz; < 300 W |
| Standby power | < 5 W |
| DC operation | 12 to 20 Vdc, < 200 W power consumption |
| Internal data storage (nominal) | 200 traces or states / 8.0 MB |
| External data storage | 3.5″ 1.44 MB, MS-DOS |
| Display resolution | 640 x 480 |
| Width to outside of instrument handle | 416 mm (16.4 in.) |
| Overall height | 222 mm (8.75 in.) |
| Depth from front frame to rear frame | 409 mm (16.1 in.) |
| Depth with instrument handle rotated horizontal | 516 mm (20.3 in.) |
| Inputs / Outputs (Front Panel) | |
| RF Input | 50 Ω type N (f); 75 Ω BNC (f) (Opt. 1DP); 50 Ω APC 3.5 (m) (Opt. BAB) |
| RF Output | 50 Ω type N (f); 75 Ω BNC (f) (Opt. 1DQ) |
| Probe power | +15 Vdc, -12.6 Vdc at 150 mA maximum (characteristic) |
| External keyboard | 6-pin mini-DIN, PC keyboards |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Agilent
Condition
Used
Manufacturer
Agilent
Frequency
1.5 GHz
44
Yellow spectrum analyzer backpack
49
Color Display
60
Low emissions shielding
106
Bluetooth FSK demodulator
120
ACPR dynamic range extension
1AX
Serial Interface
1D5
High Stability Frequency Reference
1D6
Time-gated spectrum analysis
1DN
Tracking generator
1DP
75 OHM INPUT (E4411B)
1DR
Narrow resolution bandwidths
1DS
Preamp
219
Noise Figure
226
Phase Noise
228
Bluetooth measurement personality
229
Modulation Analysis
231
ESA to 89601A VSA software link
252
EDGE UPGRADE TO GSM MEASUREMENT PERSONALITY
535
Type N Input Connector
A4H
GPIB and Centronics interface
A4J
IF and sweep ports
AYQ
EMI DETECTORS AND FM DEMODULATION
AYX
Fast time-domain sweep
AYZ
External Mixing
B72
Enhanced Memory Upgrade
B74
RF/Digital communication hardware
B75
Performance Bundle (1D5+1DR+1DS)
B7D
Digital Signal Processing and Fast ADC
B7E
RF Communications Hardware
BAA
FM Demodulation
BAC
cdmaOne Measurement Personality
BAH
GSM/GPRS measurement personality
BAS
Includes IF/sweep port (A4J) and GPIB connection (A4H)
COM
COMMUNICATIONS TEST ANALYZER (B7D/B7E/1D5/1DR/BAA/231)
STD
10 Hz , 100 Hz , 1 kHz , 10 kHz , 100 kHz , 1 MHz
STG
Standard analyzer with tracking generator (1DN , AYX , BAA)
UKB
100 Hz low frequency extension
Request A Quote