Skip to product information
1 of 1

Tektronix TBS2102 100 MHz 2-Channel Digital Storage Oscilloscope (Pre-Owned)

Tektronix TBS2102 100 MHz 2-Channel Digital Storage Oscilloscope (Pre-Owned)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Tektronix TBS2102 100 MHz 2-Channel Digital Storage Oscilloscope (Pre-Owned)

Key Features At A Glance

  • Bandwidth from 70 MHz to 100 MHz across the series, available in 2- and 4-analog-channel models
  • 1 GS/s sample rate and 20 M point record length on all channels across every model in the series
  • 9-inch WVGA color display with 15 horizontal grids and 10 vertical divisions to show more of the signal
  • TekVPI probe interface supports active, differential, and current probes with automatic scaling and units
  • 32 automated measurements plus a dedicated FFT function for thorough waveform analysis
  • USB 2.0 host/device ports and LXI-compliant 10/100BASE-T Ethernet standard; optional Wi-Fi via TEK-USB-WIFI dongle
  • HelpEverywhere on-screen tips and a built-in Scope Intro handbook for guided operation
  • 5-year warranty covering all parts and labor (excluding probes)
View full details

The TBS2000 Series is a family of digital storage oscilloscopes built around a 9-inch WVGA display, a 20 million point record length, and a 1 GS/s sample rate, capturing and displaying more signal to help engineers evaluate designs faster. On-waveform cursor readouts and 32 automated measurements—each accompanied by informative on-screen tips—make it straightforward to analyze signals and choose the right measurement. The TekVPI probe interface works with traditional BNC connections while also enabling the latest active voltage and current probes for wide application coverage.

An oscilloscope displays electrical signals as waveforms—voltage plotted against time—making it one of the most universal diagnostic instruments on an electronics bench. The TBS2000 Series trigger system is designed for troubleshooting mixed-signal designs, and the long record length helps find signal anomalies and verify digital communications. The series also targets education: the Courseware function lets professors load lab exercises onto the instrument to guide students at each station, and the oscilloscope integrates with the TekSmartLab lab management system so instructors can preset a lab full of instruments and track every student's progress from a central workstation.

ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, giving customers a single dependable source for both new and used test and measurement equipment. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

Tektronix, founded in 1946, has operated continuously under its own name. It was acquired by Danaher Corporation in 2007 and became part of Fortive Corporation when Fortive was spun off from Danaher in 2016.

Compare Other Models in This Series

The TBS2000 Series comprises four digital storage oscilloscope models that share the same core architecture—a 1 GS/s sample rate, a 20 M point record length on all channels, and a 9-inch WVGA display—while differing in two dimensions: analog bandwidth and channel count. The series is offered in 70 MHz and 100 MHz bandwidth models and in 2- and 4-channel configurations.

Because the acquisition system, display, triggering, measurement set, and TekVPI probe interface are common to every model, the choice between members of the family comes down to the bandwidth and channel count an application requires rather than differences in feature set.

Each model in the family below is its own dedicated product page with condition-matched pricing. Select the model that fits your bandwidth and channel requirements, then choose the pre-owned listing that matches your budget and condition preference.

The four models divide along bandwidth and channel count: the 70 MHz and 100 MHz options set the analog bandwidth, while the 2-channel and 4-channel options set how many signals can be observed at once. All four retain the 1 GS/s sample rate and 20 M point record length, so those specifications do not differentiate the models.

Physical size tracks channel count as well: the 2-channel models share one chassis footprint and weight (2.62 kg standalone) while the 4-channel models are larger and heavier (4.17 kg standalone). The comparison table below lays out bandwidth, channel count, and dimensions for each model so the right configuration is easy to identify.

Model Bandwidth Analog Channels Sample Rate
TBS2102 100 MHz 2 1 GS/s
TBS2072 70 MHz 2 1 GS/s
TBS2074 70 MHz 4 1 GS/s
TBS2104 100 MHz 4 1 GS/s

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • TPP0100 100 MHz, 10x passive probe (one per analog channel)
  • Documentation CD (063-4568-xx)
  • Installation and safety manual (071-3445-xx)
  • Programmer manual (077-1149-xx), available on documentation CD and on Tek Web
  • Power cord
  • Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001 quality system registration

Product Core & Specifications

Specification Value
Model Overview
Analog channels 2
Bandwidth 100 MHz
Sample rate 1 GS/s
Record length 20 M points
Vertical System (Analog Channels)
Hardware bandwidth limits 20 MHz, typical
Input coupling DC, AC, or GND
Input impedance 1 MΩ ± 2 %, 11.5 pF ± 2.5 pF
Input sensitivity range 2 mV/Div to 5 V/Div
Vertical resolution 8 bits
Maximum input voltage, 1 MΩ 300 V RMS with peaks ≤ ±450 V
DC balance ± (1 mV +0.1 div)
DC gain accuracy ± 3% 10 mV/div through 5 V/div; ± 4% typical 2 mV/div and 5 mV/div
DC voltage measurement accuracy (average mode, average of 16 waveforms) ±((DC Gain Accuracy) X |reading - (offset - position)| + Offset Accuracy + 0.11 div + 1 mV)
Delta Volts between any two averages of ≥16 waveforms acquired with the same oscilloscope setup and ambient conditions ±(DC Gain Accuracy X |reading| + 0.08 div + 1.4 mV)
Vertical position range ± 5 divisions
Vertical offset range, 2 mV/div to 200 mV/div, 1 MΩ ± 0.8 V
Vertical offset range, > 200 mV/div to 5 V/div, 1 MΩ ± 20 V
Analog bandwidth, DC coupled DC to ≥100 MHz for 2 mV/div through 5 V/div.
Common mode rejection ratio (CMRR), typical 100:1 at 60 Hz, reducing to 10:1 with 50 MHz sine wave with equal Volts/div and coupling settings on each channel.
Channel-to-channel isolation ≥100:1 at ≤100 MHz
Acquisition Modes
Sample Acquire sampled values.
Peak Detect Captures glitches as narrow as 3.5 ns at all sweep speeds.
Average From 2 to 512 waveforms included in average.
Hi-Res Averages multiple sample of one acquisition interval into one waveform point.
Roll Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div (400 ms/div at 20M record length).
Math Modes
Math functions Ch 1 - Ch 2, Ch 2 - Ch 1, Ch 1 + Ch 2, Ch 1 X Ch 2, FFT
Horizontal System (Analog Channels)
Maximum duration of time captured at highest sample rate (all channels) 40 ms
Time base range 2 ns/div to 100 sec/div
Time-base delay time range -15 divisions to 5000 s
Deskew range ±100 ns
Time base accuracy ±25 ppm over any ≥1 ms interval
Trigger System
Trigger modes Auto, Normal, and Single
Trigger holdoff range 20 ns to 8 s
Trigger type: Edge Positive or negative slope on any channel. Coupling includes DC, HF reject, LF reject, and noise reject.
Trigger type: Pulse width Trigger on width of positive or negative pulses that are >, <, =, or ≠ a specified period of time.
Trigger type: Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.
Trigger coupling (analog channels) DC, Noise Reject, High Freq Reject, Low Freq Reject.
Sensitivity, edge-type trigger, DC coupled (analog inputs) 0.4 division from DC to 50 MHz; 0.6 divisions >50 MHz to 100 MHz
Trigger level ranges Input channels: ± 4.90 divisions from center screen
Data Storage
Nonvolatile memory retention time, typical No time limit for Front Panel Settings, saved waveforms, setups, and calibration constants.
Real-Time clock A programmable clock providing time in years, months, days, hours, minutes, and seconds.
Waveform Measurements
Cursors Time, amplitude and screen.
Automated measurements 32, of which up to six can be displayed on-screen at any one time. Measurements include: Period, Frequency, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area, Cycle Area, Delay FR, Delay FF, Delay FR, and Delay RR.
Gating Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, between waveform cursors or full record length.
Waveform Math
Arithmetic Add, subtract, and multiply waveforms.
FFT Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris.
Remote Control Software
LXI web page LXI Core 2011. Built-in web page enables remote control of horizontal and vertical scale, trigger settings, and measurements. Allows waveform and image save to USB flash drive.
Display System
Display type 9 inch (228 mm) wide format liquid crystal TFT color display.
Display resolution 800 horizontal by 480 vertical displayed pixels (WVGA).
Waveform styles Vectors, Variable Persistence, and Infinite Persistence.
Graticules Grid, None.
Format YT and XY.
Input Output Ports
USB 2.0 high-speed host port Supports USB mass storage devices, Wi-Fi dongle. One port available on rear panel and one on front panel.
USB 2.0 high-speed device port Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB with a TEK-USB-488.
Compatible USB-WIFI dongles TEK-USB-WIFI accessory; TP-LINK TL-WN823N, NETGEAR WNA1000M, WNA3100M
LAN port (Ethernet) RJ-45 connector, supports 10/100BASE-T.
Probe compensator Amplitude 5 V, Frequency 1 kHz
Kensington-style lock Rear-panel security slot connects to standard Kensington-style lock.
Important: Maximum input voltage (1 MΩ): 300 V RMS with peaks ≤ ±450 V.
Important: A Wi-Fi adapter is available in some countries from Tektronix distributors as an accessory, model TEK-USB-WIFI. See Ordering Information for details.
Important: Cooling clearance: 50 mm (2 in) is required on the left side and rear of the instrument.
Usage tip: add the TEK-USB-WIFI dongle to enable the series' wireless communications, or the TEK-USB-488 GPIB-to-USB adapter for GPIB instrument control.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Tektronix

Condition

Pre-Owned

Manufacturer

Tektronix

Osc_ch

2

Osc_freq

100 MHz

Osc_r

1 MΩ

Osc_sampl

1 GS/s