Key Features At A Glance

The Keysight N6754A is a high-performance autoranging DC power module for the N6705 DC power analyzer and the N6700 low-profile modular power system, rated 60 V/20 A/300 W (volts/amps/watts) with 6 mV/1 mV ripple and noise (p-p/rms).

  • DC Output Ratings (volts/amps/watts): 60 V/20 A/300 W
  • Ripple & Noise (p-p/rms): 6 mV/1 mV
  • Mainframe slots: 2-slot
Select Options
View full details

What the Keysight N6754A is and what it is used for

The Keysight N6754A is one output of a modular DC power system that installs in an N6705 DC power analyzer or an N6700 low-profile mainframe. The Keysight N6754A sources programmable DC voltage and current into the device under test and measures the voltage and current it delivers.

The same Keysight N6754A works on the bench in the N6705 DC power analyzer, where its output can be viewed as a meter, scope trace or data log, and in automated test systems built on N6700 mainframes, so a test written in R&D can move to manufacturing on the same module.

The Keysight N6754A has an autoranging output, so it delivers its rated power across a span of voltage and current combinations rather than only at maximum voltage and maximum current.

Keysight N6754A key specifications

Key performance specifications

Keysight N6754A: Key performance specifications (data sheet 5992-1880EN p.27)
Parameter Value
DC Output Ratings (volts/amps/watts) 60 V/20 A/300 W
Ripple & Noise (p-p/rms) 6 mV/1 mV
Voltage Programming Accuracy 0.06% + 25 mV
Current Programming Accuracy 0.1% + 12 mA
Voltage Measurement Accuracy 0.05% + 25 mV
Current Measurement Accuracy 0.1% + 8 mA

Note: This data sheet does not include a comprehensive list of all power module specifications and characteristics.

Capabilities in the data sheet's feature map

  • Its operating range encompasses both low voltage and high current, as well as high voltage and low current operating points.
  • Autoranging output capability
  • Output list capability (High-speed test extensions) (with Option 054)
  • Array readback capability (High-speed test extensions) (with Option 054)
  • Programmable sample rate (High-speed test extensions) (with Option 054)

Programming speed

Keysight N6754A: Programming speed (data sheet 5992-1880EN p.15)
Parameter Value
Down-programming an active down-programming circuit to rapidly pull down the output when lowering the output voltage
Smaller voltage changes, such as 0 V to 5 V or 5 V to 0 V less than 200 microseconds
0 V to 50 V or 50 V to 0 V less than 1.5 milliseconds

Compare the Keysight N6754A with the other N6750 high-performance, auto-ranging DC power modules

Keysight N6754A: compare N6750 high-performance, auto-ranging DC power modules (data sheet 5992-1880EN p.27; data sheet 5992-1857EN p.21)
Model DC Output Ratings (volts/amps/watts) Ripple & Noise (p-p/rms) Voltage Programming Accuracy Current Measurement Accuracy Mainframe slots
N6751A 50 V/5 A/50 W 4.5 mV/0.35 mV 0.06% + 19 mV 0.1% + 4 mA 1-slot
N6752A 50 V/10 A/100 W 4.5 mV/0.35 mV 0.06% + 19 mV 0.1% + 4 mA 1-slot
N6753A 20 V/50 A/300 W 5 mV/1 mV 0.06% + 10 mV 0.1% + 30 mA 2-slot
N6754A (this page) 60 V/20 A/300 W 6 mV/1 mV 0.06% + 25 mV 0.1% + 8 mA 2-slot
N6755A 20 V/50 A/500 W 5 mV/1 mV 0.06% + 10 mV 0.1% + 30 mA 2-slot
N6756A 60 V/17 A/500 W 6 mV/1 mV 0.06% + 25 mV 0.1% + 8 mA 2-slot

What decides whether the Keysight N6754A fits

Output ratings: does 60 V/20 A/300 W cover the device?

The Keysight N6754A is rated 60 V/20 A/300 W (volts/amps/watts). Check the device's maximum voltage and its peak current, including any start-up surge, not only its nominal draw.

Mainframe slots and power: where does the Keysight N6754A fit?

The Keysight N6754A is a 2-slot module, and each mainframe has 4 module slots. When the installed modules together need more power than the mainframe supplies, the N6705 power management feature lets you allocate mainframe power to the outputs where it is needed.

Noise and accuracy: is the Keysight N6754A quiet and accurate enough?

The Keysight N6754A ripple and noise is 6 mV/1 mV (p-p/rms). Voltage programming accuracy is 0.06% + 25 mV and current measurement accuracy is 0.1% + 8 mA.

Rules of thumb (not specifications)

Voltage, current and power envelope. DC power = voltage × current. The required voltage and current, including any start-up peak, must both lie inside the stated ranges, and their product inside the stated power — on autoranging outputs the power limit is lower than maximum voltage × maximum current. Rule of thumb, not a specification.

Example with the Keysight N6754A: The Keysight N6754A is rated 60 V/20 A/300 W (volts/amps/watts); 60 V × 20 A = 1,200 W, more than its 300 W rating, so at 60 V the current is limited to about 5 A (300 W ÷ 60 V).

Keysight N6754A options and what they change

The mainframes that take the Keysight N6754A, its factory options and the other modules in the family are listed on the Options tab, with links to their pages.

What you need with the Keysight N6754A

Keysight N6754A: Mainframe fit (data sheet 5992-1880EN p.20, 21, 29, 30, 34; data sheet 5992-1857EN p.21)
Parameter Value
Order installed in an N6715C system as N6754A-ATO
Mainframe slots 2-slot
Module slots per mainframe 4 module slots
N6705 DC power analyzer uses the same DC power modules as the N6700 low-profile modular power system for ATE
Power management (N6705) allocate mainframe power to the outputs where it’s needed
N6705C DC power analyzer mainframe Holds 1 to 4 modules. Total available output power = 600 W

Keysight N6754A safety and limits

Keysight N6754A: Outputs, protection and connections (data sheet 5992-1880EN p.5, 14, 15, 17, 29)
Parameter Value Conditions
Output isolation fully isolated and floating from the ground from each other —
Protection protected against overvoltage, overcurrent, and overtemperature —
Fault detection between modules detected within 10 microseconds by other modules —
Series operation, identically rated outputs (maximum) 240 V —
Parallel operation, identically rated outputs (maximum) 100 A as per the Keysight N6705
Remote sensing (N6705) 4-wire sensing capability, also known as remote sensing, on each of its four outputs —
N6705 front-panel binding posts rated for 20 A per post —
Temperature range (N6705) 0 °C to 55 °C (output current is derated 1% per °C above 40 °C ambient temperature) —

Other Keysight N6754A specifications

Scope and data logger in the N6705

Keysight N6754A: Scope and data logger in the N6705 (data sheet 5992-1880EN p.8, 9, 10)
Parameter Value Conditions
Fastest sample rate; buffer per trace (1 or 2 traces) 10.24 µs (~ 100 kHz); 128 k points —
Fastest sample rate; buffer per trace (3 or 4 traces) 20.48 µs (~ 50 kHz); 64 k points —
Scope traces you can select to view either a voltage trace or a current trace on the oscilloscope display —
Continuous sampling mode logging you can log either voltage or current when the module is in continuous sampling mode —
Standard data logging sample interval 75 milliseconds to 60 seconds —
Continuous data logging sample interval 20* microseconds to 60 seconds note 1

Note 1: Add 20 µs for each additional parameter (Voltage, Current, Min, or Max)

These figures apply when the module is installed in an N6705 DC power analyzer.

Functions in the N6705 DC power analyzer

Keysight N6754A: Functions in the N6705 DC power analyzer (data sheet 5992-1880EN p.9, 11, 13, 14)
Parameter Value
Output on/off delays from no delay to one thousand seconds of delay in one-millisecond increments
Programmable voltage slew from its maximum up/down programming speed to its slowest change of up to 10 seconds
Inrush current measurement set the oscilloscope to trigger on the DC output’s on/off key, set the trigger mode to single shot, and then turn on the DC output
Maximum data log file size ~2 gigabytes
Logged data export Logged data can also be exported to a CSV file that can be read by the most common data analysis software packages.

Output relay options

  • With option 761, Output Disconnect Relays, an emergency condition or turning the DC output off causes mechanical relays to disconnect both the plus and minus sides of the power supply, including the sense leads.
  • With option 760, Output Disconnect/Polarity Reversal Relays, mechanical relays switch the leads on both the positive and negative sides of the power supply, including the sense leads, resulting in a voltage polarity reversal at the DUT.
  • Although the plus and minus rail of the output power mesh is physically disconnected from the output terminals with options 760 and 761, a small AC network is still connected across the plus and minus output terminals.

Keysight N6754A questions and answers

What are the output ratings of the Keysight N6754A?

The Keysight N6754A DC output ratings are 60 V/20 A/300 W (volts/amps/watts), from the data sheet's key performance specifications.

How many outputs does the Keysight N6754A have?

The Keysight N6754A provides one DC output and is a 2-slot module; a mainframe has 4 module slots, so one mainframe combines several modules as separate, isolated outputs.

Does the Keysight N6754A have remote sense?

The Keysight N6754A uses 4-wire remote sensing when installed in an N6705 DC power analyzer, which offers 4-wire sensing capability, also known as remote sensing, on each of its four outputs.

Can Keysight N6754A outputs be combined in series or parallel?

The Keysight N6754A can be operated directly in series or in parallel with identically rated outputs. The data sheet gives a maximum series operation of 240 V and a maximum rated parallel operation of 100 A, as per the Keysight N6705.

What is the Keysight N6754A used for?

The Keysight N6754A powers devices under test from a modular system, on the R&D bench in the N6705 DC power analyzer and in automated test systems on N6700 mainframes, with the same module in both.

What else is needed to use the Keysight N6754A?

The Keysight N6754A needs a mainframe. The N6705C DC power analyzer mainframe holds 1 to 4 modules with a total available output power of 600 W, and the module can also be ordered installed in an N6715C system as N6754A-ATO.

What does the N6705 DC power analyzer add to the Keysight N6754A?

In an N6705 DC power analyzer, the Keysight N6754A output can be turned on or off with delays from no delay to one thousand seconds of delay in one-millisecond increments, driven by built-in arbitrary waveforms such as sine, step, ramp and pulse, and captured on the scope or data logger; logged data can be exported to a CSV file.

Which options change the Keysight N6754A?

The Keysight N6754A factory options from the data sheet, with what each one adds, are listed on the Options tab; the relay options disconnect the output, including the sense leads, when the output is turned off.

How is a DC power module different from an electronic load?

The Keysight N6754A sources power into a device. An electronic load does the opposite and absorbs power from a source such as a power supply or battery.

How is a DC power module different from a source/measure unit?

The Keysight N6754A is built to power a device and measure what it delivers. A source/measure unit is built for precise measurement while sourcing, including very low currents, and can also sink current.

Specifications are from the manufacturer's data sheet (Keysight Modular Power Solutions, Modular Power System Mainframes and Modules, 5992-1857EN, August 10, 2026) and data sheet (Keysight NP2-Class DC Power Analyzer, N6705 DC Power Analyzer, 5992-1880EN, October 8, 2026). Questions? Contact your Test Architect.

Updated 2026-11-25

Model No

Keysight

Condition

Factory New

Manufacturer

Keysight

Dcsup_amps

20 A

Dcsup_volts

60 V

Dcsup_watts

300 W

Plugin_type

DC Power Module

N6705C

DC power analyzer mainframe.

N6700C

Low-Profile Modular Power System mainframes.

N6701C

Low-Profile Modular Power System mainframes.

N6702C

Low-Profile Modular Power System mainframes.

761

Output disconnect relays.

760

Output disconnect and polarity reversal relays.

054

High-Speed Test Extensions (HSTE).

UK6

Commercial calibration with test results data.

1A7

ISO 17025 calibration certificate.

N6731B

5 V, 10 A, 50 W DC power module.

N6732B

8 V, 6.25 A, 50 W DC power module.

N6733B

20 V, 2.5 A, 50 W DC power module.

N6734B

35 V, 1.5 A, 50 W DC power module.

N6735B

60 V, 0.8 A, 50 W DC power module.

N6736B

100 V, 0.5 A, 50 W DC power module.

N6741B

5 V, 20 A, 100 W DC power module.

N6742B

8 V, 12.5 A, 100 W DC power module.

N6743B

20 V, 5 A, 100 W DC power module.

N6744B

35 V, 3 A, 100 W DC power module.

N6745B

60 V, 1.6 A, 100 W DC power module.

N6746B

100V, 1A, 100W DC power module.

N6751A

50 V, 5 A, 50 W high-performance autoranging DC power module.

N6752A

50 V, 10 A, 100 W high-performance autoranging DC power module.

N6753A

20 V, 50 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).

N6755A

20 V, 50 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).

N6756A

60 V, 17 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).

N6761A

50 V, 1.5 A, 50 W precision DC power module.

N6762A

50 V, 3 A, 100 W precision DC power module.

N6763A

20 V, 50 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots).

N6764A

60 V, 20 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots).

N6765A

20 V, 50 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots).

N6766A

60 V, 17 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots).

N6773A

20 V, 15 A, 300 W DC power module.

N6774A

35 V, 8.5 A, 300 W DC power module.

N6775A

60 V, 5 A, 300 W DC power module.

N6776A

100 V, 3 A, 300 W DC power module.

N6777A

150 V, 2 A, 300 W DC power module.

N6781A

20 V, ± 3 A, 20 W source/measure unit.

N6782A

20 V, ± 3 A, 20 W source/measure unit.

N6784A

± 20 V, ± 3 A, 20 W source/measure unit.

N6783A-BAT

8 V, 3 A, 24 W battery charge/discharge module.

N6783A-MFG

6 V, 3 A, 18 W mobile communications module.

N6785A

20 V, +/-8A, 80 W source/measure unit.

N6786A

20 V, +/-8A, 80 W source/measure unit.

N6791A

60 V, 20 A, 100 W DC electronic load.

N6792A

60 V, 40 A, 200 W DC electronic load.