Agilent N1914A EPM Series Dual-Channel Average Power Meter (Pre-Owned)

Agilent N1914A EPM Series Dual-Channel Average Power Meter (Pre-Owned)

Calibrations

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Agilent N1914A EPM Series Dual-Channel Average Power Meter (Pre-Owned)

Key Features At A Glance

  • Frequency coverage from 9 kHz to 110 GHz; power from ‒70 dBm to +44 dBm (100 pW to 25 W), sensor dependent
  • GPIB, USB, and LAN/LXI-C interfaces standard for remote control and automated power measurement systems
  • Industry's first high-resolution color LCD readout in an average power meter
  • Absolute accuracy ±0.02 dB (log) / ±0.5% (linear); relative ±0.04 dB (log) / ±1% (linear)
  • Available single-channel (N1913A) or dual-channel (N1914A); up to four channels via optional USB sensor ports
  • Compatible with 8480 Series, E-Series E4410/E9300, N8480 Series, and U2000 Series USB power sensors
  • Optional battery operation, external trigger in/out for sweep automation, and VGA monitor output
Select Options
11730B Agilent Cable Used
$175.00
11730A Agilent Cable Used
$105.00
View full details

The Agilent N1913A and N1914A are EPM Series average power meters offered as versatile, user-friendly replacements for the E4418B/E4419B EPM Series. The N1913A is a single-channel average power meter and the N1914A is a dual-channel average power meter. Both deliver consistent results and greater capability while remaining code-compatible with the legacy E4418B/E4419B EPM Series instruments, allowing established measurement routines to carry forward.

Across the compatible sensor set, the EPM Series addresses CW, modulated CW, pulse/averaged, and AM/FM profiled signals, along with wireless-standard measurements spanning mobile phone, WLAN, WPAN, and WMAN classes. Typical application examples include metrology lab work, radar and navigation, and mobile radio formats such as GSM, EDGE, GPRS, CDMA2000, cdmaONE, IDEN, 3G, HSPA, and LTE, as well as 802.11a/b/g/n, Bluetooth, RFID, ZigBee, WiMAX, and WiBro — with average-only support indicated for several modulated and wireless formats depending on the attached sensor.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive, Elgin, Illinois, which lets us match the right instrument and sensor configuration to an application directly from equipment we keep on hand. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

Agilent Technologies was established in 1999 as a spin-off of Hewlett-Packard's test and measurement business. In 2014, that electronic measurement business was transferred to Keysight Technologies, which continues the product line today.

Compare Other Models in This Series

The EPM Series spans two average power meters that share frequency coverage, power range, accuracy specifications, and sensor compatibility but differ in channel count. The N1913A is the single-channel model and the N1914A is the dual-channel model, both serving as code-compatible replacements for the E4418B/E4419B EPM Series.

Each model accepts the same families of compatible power sensors — 8480 Series, E-Series E4410 and E9300, N8480 Series, and U2000 Series USB sensors — and shares the color LCD, the GPIB/USB/LAN interface set, and the internal 1 mW, 50 MHz power reference.

Each model below links to its own dedicated product page with condition-matched pricing for the pre-owned configuration you select. Choose the model that matches your channel-count and code-compatibility requirements, then select the listing for your preferred condition.

The N1913A single-channel meter offers optional code compatibility with the 436A and 437B; the N1914A dual-channel meter offers optional code compatibility with the 438A. On the N1914A, measurement speed is reduced when both channels operate — for example, with both channels in Fast mode the typical maximum is 200 readings per second — and the rear-panel recorder outputs are dedicated to channel A and channel B.

The principal difference across the family is channel count: the N1913A measures a single channel while the N1914A measures two channels, expandable to a total of four channels on either model through optional USB sensor ports. Measurement-speed behavior also differs, since the dual-channel N1914A's typical maximum speed depends on how many channels are active.

Optional 43X code compatibility differs by model as well — 436A/437B on the N1913A and 438A on the N1914A — along with standalone code-compatibility upgrade options. See the comparison table for the model-by-model breakdown of channels, code compatibility, and net weight.

Model Channels Frequency Range Power Range
N1914A 2 (up to 4 with optional USB) 9 kHz to 110 GHz –70 dBm to +44 dBm (100 pW to 25 W)
N1913A 1 9 kHz to 110 GHz –70 dBm to +44 dBm (100 pW to 25 W)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Power cord
  • Power sensor cable, 1.5 m (5 ft) (two per N1914A)
  • USB cable Type A to Mini-B, 6 ft
  • Product CD-ROM (contains English and localized User's Guide and Programming Guide)
  • Agilent IO Libraries Suite CD-ROM
  • Calibration certificate
Replaces: per the manufacturer, this model replaces E4418B, E4419B.

Product Core & Specifications

Specification Value
Measurement
Compatible power sensors Agilent 8480 Series; Agilent E9300 E-Series; Agilent E4410 E-Series; Agilent N8480 Series; Agilent U2000 Series
Frequency range 9 kHz to 110 GHz, sensor dependent
Power range –70 dBm to +44 dBm (100 pW to 25 W), sensor dependent
Single sensor dynamic range 90 dB maximum (Agilent E-Series power sensors); 50 dB maximum (Agilent 8480 Series power sensors); 55 dBm maximum (Agilent N8480 Series power sensors); 80 dBm maximum (Agilent U2000 Series USB power sensors)
Display
Display units Absolute: Watts or dBm; Relative: Percent or dB
Display resolution Selectable resolution of: 1.0, 0.1, 0.01 and 0.001 dB in logarithmic mode, or 1, 2, 3 and 4 significant digits in linear mode
Default resolution 0.01 dB in logarithmic mode or three digits in linear mode
Display type Color display with selectable single and split screen formats. A quasi-analog display is available for peaking measurements. The dual channel power meter can simultaneously display any two configurations of A, B, A/B, B/A, A-B, B-A and relative. With the optional USB ports, additional dual channel (C & D) adds up to a total 4-channel measurement display.
Accuracy
Absolute accuracy ±0.02 dB (Logarithmic) or ±0.5% (Linear). Add the corresponding power sensor linearity percentage from Tables 6, 9 and 10 (E-Series), Table 14 (8480 Series) and Table 16 (N8480) to assess overall system accuracy.
Relative accuracy ±0.04 dB (Logarithmic) or ±1.0% (Linear). Add the corresponding power sensor linearity percentage from the tables above to assess overall system accuracy.
Zero set (digital settability of zero) Power sensor dependent (refer Table 1); applies when zeroing is performed with the sensor input disconnected from the POWER REF.
Zero drift of sensors Sensor dependent, refer to Table 1. For E9300 sensors, refer to Table 11.
Measurement noise Sensor dependent, refer to Tables 1 and 2. For E9300 sensors, refer to Table 11.
Effects of averaging on noise Averaging over 1 to 1024 readings is available for reducing noise.
1 mW Power Reference
Power output 1.00 mW (0.0 dBm). Factory set to ±0.4 % traceable to the National Physical Laboratories (NPL), UK
Accuracy (for two years) ±0.4% (25 ±10 ºC); ±1.2% (0 to 55 ºC)
Frequency 50 MHz nominal
SWR 1.05 (typical), 1.08 (0 to 55ºC)
Connector type Type-N (f), 50 Ω
Measurement Speed
N1913A Normal: 20 readings/second; x2: 40 readings/second; Fast: 400 readings/second
N1914A Measurement speed is reduced; with both channels in FAST mode, the typical maximum measurement speed is 200 readings/second
Notes Fast mode is for Agilent E-Series power sensors only. Maximum measurement speed is obtained using binary output in free run trigger mode.
Power Meter Functions
Zero Zeros the meter (power reference calibrator is switched off during zeroing)
Cal Calibrates the meter using internal (power reference calibrator) or external source. Reference cal factor settable from 1% to 150%, in 0.1% increments.
Frequency Frequency range from 1 kHz to 999.9 GHz. Also settable in 1 kHz steps.
Cal factor Range: 1% to 150%, in 0.1% increments
Relative Displays all successive measurements relative to the last displayed value
Offset Allows power measurements to be offset by –100 dB to +100 dB, settable in 0.001 dB increments
Save/recall Store up to 10 instrument states via the save/recall menu
dBm/W Selectable units of either Watts or dBm in absolute power; or percent or dB for relative measurements
Filter (averaging) Selectable from 1 to 1024. Auto-averaging provides automatic noise compensation.
Duty cycle Duty cycle values between 0.001% to 99.999%, in 0.001% increments
Limits High and low limits can be set in the range –150.000 dBm to +230.000 dBm, in 0.001 dBm increments
General
Dimensions 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in), excluding front and rear protrusions
Weight, N1913A Net: 3.6 kg (8.0 lb); Shipping: 8.2 kg (18.1 lb)
Weight, N1914A Net: 3.7 kg (8.2 lb); Shipping: 8.2 kg (18.3 lb)
Rear Panel Connectors
Recorder outputs Analog 0 to 1 Volt, 1 kΩ output impedance, BNC connector. N1914A recorder outputs are dedicated to channel A and channel B.
GPIB, USB 2.0 and 10/100BaseT LAN Interfaces to allow communication with an external controller
Trigger Input (optional) TTL compatible logic levels, BNC connector. High: >2.4 V Low: <0.7 V
Trigger Output (optional) TTL compatible logic levels, BNC connector. High: >2.4 V Low: <0.7 V
Ground Binding post, accepts 4 mm plug or bare wire connection
USB Host (options) USB ports which connect to U2000 series USB power sensors
VGA Out (options) Standard 15-pin VGA connector, allows connection of external VGA monitor
Line Power
Input voltage range 90 to 264 VAC, automatic selection
Input frequency range 47 to 63 Hz and 400 Hz @ 110 Vac
Power requirement 75 VA (50 Watts)
Battery Option (operational characteristics at 25 °C)
Typical operating time Up to 6 hours with LCD backlight on; up to 7.5 hours with LCD backlight off (N1913A power meter)
Charge time Approximately 2.5 hours to charge fully from an empty state. Power meter is operational whilst charging.
Battery type Lithium-ion (Li-ion)
Battery storage temperature –20 °C to 60 °C, ≤80 % RH
Environmental Characteristics
Electromagnetic compatibility Complies with EMC Directive (2004/108/EC): IEC61326-1:2005 / EN61326-1:2006; CISPR11:2003 / EN55011:2007 (Group 1, Class A); Canada: ICES/NMB-001:2004; Australia/New Zealand: AS/NZS CISPR 11:2004
Product safety IEC 61010-1:2001 / EN 61010-1:2001; CAN/CSA-C22.2 No.61010-1-04; ANSI/UL61010-1:2004
Low Voltage Directive Conforms to European Council Directive 2006/95/EC
Operating temperature 0 °C to 55 °C
Important: Fast measurement-speed mode (up to 400 readings/second) is available with Agilent E-Series power sensors only.
Important: A compatible power sensor (Agilent 8480 Series, E9300/E4410 E-Series, N8480 Series, or U2000 Series) is required to make power measurements and is NOT included in the standard-shipped accessories; the appropriate sensor must be ordered separately (the meter ships with power cord, sensor cable, USB cable, CD-ROMs and calibration certificate only).
Important: 436A/437B/438A code (43X) compatibility is available only with option N191xA-200: the N1913A is backward compatible with the 436A and 437B, while the N1914A is compatible with the 438A.
Important: The N1913A/14A power meters are compatible with all 8480 Series power sensors, including discontinued models.
Important: Battery operation (single-button battery confirmation and operating time) applies only to models ordered with the battery option (N1913/4A-B02).

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Keysight Technologies

Keysight W8486A Diode Power Sensor, 75 GHz to 110 GHz (Pre-Owned)

W8486A

Keysight N8486AQ Thermocouple Power Sensor, 33 GHz to 50 GHz (Pre-Owned)

N8486AQ

Keysight N8486AR Thermocouple Power Sensor, 26.5 GHz to 40 GHz (Pre-Owned)

N8486AR

Keysight U2000B USB Power Sensor, 10 MHz to 18 GHz, -30 to +44 dBm (Pre-Owned)

U2000B

Agilent 8487D High Sensitivity Power Sensor, 50 MHz to 50 GHz (Pre-Owned)

8487D

Keysight U2002A USB Power Sensor, 50 MHz to 24 GHz, -60 to +20 dBm (Pre-Owned)

U2002A

Keysight U2001B USB Power Sensor, 10 MHz to 6 GHz, -30 to +44 dBm (Pre-Owned)

U2001B

Keysight U2000H USB Power Sensor, 10 MHz to 18 GHz, -50 to +30 dBm (Pre-Owned)

U2000H

Keysight U2000A USB Power Sensor, 10 MHz to 18 GHz, -60 to +20 dBm (Pre-Owned)

U2000A

Keysight N8487A Thermocouple Power Sensor, 50 MHz to 50 GHz, -35 to +20 dBm (Pre-Owned)

N8487A

Keysight U2001H USB Power Sensor, 10 MHz to 6 GHz, -50 to +30 dBm (Pre-Owned)

U2001H

Keysight N8482B High Power Thermocouple Power Sensor, 100 kHz to 6 GHz, -5 to +44 dBm (Pre-Owned)

N8482B

Keysight N8481B High Power Thermocouple Power Sensor, 10 MHz to 18 GHz, -5 to +44 dBm (Pre-Owned)

N8481B

Keysight E9300B E-Series Average Power Sensor, 10 MHz to 18 GHz, -30 to +44 dBm (Pre-Owned)

E9300B

Keysight U2004A USB Power Sensor, 9 kHz to 6 GHz, -60 to +20 dBm (Pre-Owned)

U2004A

Keysight U2001A USB Power Sensor, 10 MHz to 6 GHz, -60 to +20 dBm (Pre-Owned)

U2001A

Keysight E9301B E-Series Average Power Sensor, 10 MHz to 6 GHz, -30 to +44 dBm (Pre-Owned)

E9301B

Agilent 8485D High Sensitivity Power Sensor, 50 MHz to 26.5 GHz (Pre-Owned)

8485D

Keysight E9300H E-Series Average Power Sensor, 10 MHz to 18 GHz, -50 to +30 dBm (Pre-Owned)

E9300H

Keysight E9300A E-Series Average Power Sensor, 10 MHz to 18 GHz, -60 to +20 dBm (Pre-Owned)

E9300A

Keysight E4413A E-Series CW Power Sensor, 50 MHz to 26.5 GHz, -70 to +20 dBm (Pre-Owned)

E4413A

Keysight N8485A Thermocouple Power Sensor, 10 MHz to 26.5 GHz, -35 to +20 dBm (Pre-Owned)

N8485A

Keysight 8483A Thermocouple Power Sensor, 100 kHz to 2 GHz, 75-Ohm (Pre-Owned)

8483A

Keysight N8482H High Power Thermocouple Power Sensor, 100 kHz to 6 GHz, -15 to +35 dBm (Pre-Owned)

N8482H

Keysight N8481H High Power Thermocouple Power Sensor, 10 MHz to 18 GHz, -15 to +35 dBm (Pre-Owned)

N8481H

Keysight E9301H E-Series Average Power Sensor, 10 MHz to 6 GHz, -50 to +30 dBm (Pre-Owned)

E9301H

Keysight E9304A E-Series Average Power Sensor, 9 kHz to 6 GHz, -60 to +20 dBm (Pre-Owned)

E9304A

Agilent 8481D High Sensitivity Power Sensor, 10 MHz to 18 GHz (Pre-Owned)

8481D

Keysight E9301A E-Series Average Power Sensor, 10 MHz to 6 GHz, -60 to +20 dBm (Pre-Owned)

E9301A

Keysight E4412A E-Series CW Power Sensor, 10 MHz to 18 GHz, -70 to +20 dBm (Pre-Owned)

E4412A

Keysight N8482A Thermocouple Power Sensor, 100 kHz to 6 GHz, -35 to +20 dBm (Pre-Owned)

N8482A

Keysight N8481A Thermocouple Power Sensor, 10 MHz to 18 GHz, -35 to +20 dBm (Pre-Owned)

N8481A

Keysight 82357B USB/GPIB Converter for N1913A/N1914A EPM Series (Pre-Owned)

82357B

11730C Agilent Cable Used

11730C

11730B Agilent Cable Used

11730B

11730A Agilent Cable Used

11730A

10833C Agilent GPIB Cable Used

10833C

10833B Agilent GPIB Cable Used

10833B

10833A Agilent GPIB Cable Used

10833A

10833D Agilent GPIB Cable Used

10833D

Keysight R8486D Diode Power Sensor, 26.5 GHz to 40 GHz (Pre-Owned)

R8486D