The Keysight N6761A is one output of a modular DC power system that installs in an N6705 DC power analyzer or an N6700 low-profile mainframe. The Keysight N6761A sources programmable DC voltage and current into the device under test and measures the voltage and current it delivers.
The same Keysight N6761A works on the bench in the N6705 DC power analyzer, where its output can be viewed as a meter, scope trace or data log, and in automated test systems built on N6700 mainframes, so a test written in R&D can move to manufacturing on the same module.
The Keysight N6761A has an autoranging output, so it delivers its rated power across a span of voltage and current combinations rather than only at maximum voltage and maximum current.
The Keysight N6761A adds precision voltage and current measurements, low measurement ranges and simultaneous voltage and current scope traces, and its high-speed test extensions are standard.
| Parameter | Value | Conditions |
|---|---|---|
| DC Output Ratings (volts/amps/watts) | 50 V/1.5 A/50 W | highest range (note 1) |
| Ripple & Noise (p-p/rms) | 4.5 mV/0.35 mV | highest range (note 1) |
| Voltage Programming Accuracy | 0.016% + 6 mV | highest range (note 1) |
| Current Programming Accuracy | 0.04% + 0.2 mA | highest range (note 1) |
| Voltage Measurement Accuracy | 0.016% + 6 mV | highest range (note 1) |
| Current Measurement Accuracy | 0.04% + 0.16 mA | highest range (note 1) |
Note 1: These power modules have multiple output and measurement ranges; the values shown are for the highest range.
Note: This data sheet does not include a comprehensive list of all power module specifications and characteristics.
| Parameter | Value |
|---|---|
| Down-programming | an active down-programming circuit to rapidly pull down the output when lowering the output voltage |
| Smaller voltage changes, such as 0 V to 5 V or 5 V to 0 V | less than 200 microseconds |
| 0 V to 50 V or 50 V to 0 V | less than 1.5 milliseconds |
| Parameter | Value |
|---|---|
| High-Speed Test Extensions (HSTE) | Standard |
| Model | DC Output Ratings (volts/amps/watts) | Ripple & Noise (p-p/rms) | Voltage Programming Accuracy | Current Measurement Accuracy | Mainframe slots |
|---|---|---|---|---|---|
| N6761A (this page) | 50 V/1.5 A/50 W * | 4.5 mV/0.35 mV * | 0.016% + 6 mV * | 0.04% + 0.16 mA * | 1-slot |
| N6762A | 50 V/3 A/100 W * | 4.5 mV/0.35 mV * | 0.016% + 6 mV * | 0.04% + 0.16 mA * | 1-slot |
| N6763A | 20 V/50 A/300 W * | 5 mV/1 mV * | 0.03% + 5 mV * | 0.1% + 10 mA * | 2-slot |
| N6764A | 60 V/20 A/300 W * | 6 mV/1 mV * | 0.03% + 12 mV * | 0.1% + 5 mA * | 2-slot |
| N6765A | 20 V/50 A/500 W * | 5 mV/1 mV * | 0.03% + 5 mV * | 0.1% + 10 mA * | 2-slot |
| N6766A | 60 V/17 A/500 W * | 6 mV/1 mV * | 0.03% + 12 mV * | 0.1% + 5 mA * | 2-slot |
* These power modules have multiple output and measurement ranges; the values shown are for the highest range.
The Keysight N6761A is rated 50 V/1.5 A/50 W (volts/amps/watts). Check the device's maximum voltage and its peak current, including any start-up surge, not only its nominal draw.
The Keysight N6761A is a 1-slot module, and each mainframe has 4 module slots. When the installed modules together need more power than the mainframe supplies, the N6705 power management feature lets you allocate mainframe power to the outputs where it is needed.
The Keysight N6761A ripple and noise is 4.5 mV/0.35 mV (p-p/rms). On its highest range, voltage programming accuracy is 0.016% + 6 mV and current measurement accuracy is 0.04% + 0.16 mA; the module also has low measurement ranges for smaller currents.
The Keysight N6761A with Option 2UA adds a 200 μA measurement range with an ammeter measurement accuracy of 0.5% of reading + 100 nA. Option 2UA must be ordered with the module; a module bought without it cannot be upgraded.
Voltage, current and power envelope. DC power = voltage × current. The required voltage and current, including any start-up peak, must both lie inside the stated ranges, and their product inside the stated power — on autoranging outputs the power limit is lower than maximum voltage × maximum current. Rule of thumb, not a specification.
Example with the Keysight N6761A: The Keysight N6761A is rated 50 V/1.5 A/50 W (volts/amps/watts); 50 V × 1.5 A = 75 W, more than its 50 W rating, so at 50 V the current is limited to about 1 A (50 W ÷ 50 V).
The mainframes that take the Keysight N6761A, its factory options and the other modules in the family are listed on the Options tab, with links to their pages.
| Parameter | Value |
|---|---|
| Order installed in an N6715C system as | N6761A-ATO |
| Mainframe slots | 1-slot |
| Module slots per mainframe | 4 module slots |
| N6705 DC power analyzer | uses the same DC power modules as the N6700 low-profile modular power system for ATE |
| Power management (N6705) | allocate mainframe power to the outputs where it’s needed |
| N6705C DC power analyzer mainframe | Holds 1 to 4 modules. Total available output power = 600 W |
| Parameter | Value | Conditions |
|---|---|---|
| Output isolation | fully isolated and floating from the ground from each other | — |
| Protection | protected against overvoltage, overcurrent, and overtemperature | — |
| Fault detection between modules | detected within 10 microseconds by other modules | — |
| Series operation, identically rated outputs (maximum) | 240 V | — |
| Parallel operation, identically rated outputs (maximum) | 100 A | as per the Keysight N6705 |
| Remote sensing (N6705) | 4-wire sensing capability, also known as remote sensing, on each of its four outputs | — |
| N6705 front-panel binding posts | rated for 20 A per post | — |
| Temperature range (N6705) | 0 °C to 55 °C (output current is derated 1% per °C above 40 °C ambient temperature) | — |
| With the output disconnect relays open (Option 761) | a small AC network is still connected across the plus and minus output terminals. | — |
| Parameter | Value | Conditions |
|---|---|---|
| Fastest sample rate; buffer per trace (1 or 2 traces) | 10.24 µs (~ 100 kHz); 128 k points | — |
| Fastest sample rate; buffer per trace (3 or 4 traces) | 20.48 µs (~ 50 kHz); 64 k points | — |
| Standard data logging sample interval | 75 milliseconds to 60 seconds | — |
| Continuous data logging sample interval | 20* microseconds to 60 seconds | note 1 |
| Continuous sampling mode logging | simultaneously log output voltage and output current | — |
Note 1: Add 20 µs for each additional parameter (Voltage, Current, Min, or Max)
These figures apply when the module is installed in an N6705 DC power analyzer.
| Parameter | Value |
|---|---|
| Output on/off delays | from no delay to one thousand seconds of delay in one-millisecond increments |
| Programmable voltage slew | from its maximum up/down programming speed to its slowest change of up to 10 seconds |
| Inrush current measurement | set the oscilloscope to trigger on the DC output’s on/off key, set the trigger mode to single shot, and then turn on the DC output |
| Maximum data log file size | ~2 gigabytes |
| Logged data export | Logged data can also be exported to a CSV file that can be read by the most common data analysis software packages. |
| Parameter | Value | Conditions |
|---|---|---|
| Ammeter Measurement Accuracy (at 23°C ±5°C) in 200 μA range | 0.5% of reading + 100 nA | Option 2UA |
| Measurement Temperature Coefficient per °C in 200 μA range | 200 ppm + 2 nA/°C | Option 2UA |
| Output disconnect relays | Includes output disconnect relays (same as Option 761) | — |
| Other specifications | When Option 2UA is installed, all DC source specifications and all other measurement specifications of the two higher ranges remain unchanged | — |
| Continuous output current | Up to 3 A continuous output current on N6762A (or up to 1.5 A on N6761A) | — |
| Application | Leakage current measurement of handset power amplifiers and other semiconductor devices | — |
| Application | Sleep mode current measurement of battery powered devices | — |
| Load | Stable with capacitive loads | — |
| Ordering | Option 2UA must be ordered at the time of purchase of the N6761A or N6762A module. Previously purchased N6761A or N6762A modules cannot be upgraded to include Option 2UA. | — |
The Keysight N6761A DC output ratings are 50 V/1.5 A/50 W (volts/amps/watts) on its highest range, and the data sheet's feature map adds low voltage and current output ranges.
The Keysight N6761A provides one DC output and is a 1-slot module; a mainframe has 4 module slots, so one mainframe combines several modules as separate, isolated outputs.
The Keysight N6761A uses 4-wire remote sensing when installed in an N6705 DC power analyzer, which offers 4-wire sensing capability, also known as remote sensing, on each of its four outputs.
The Keysight N6761A can be operated directly in series or in parallel with identically rated outputs. The data sheet gives a maximum series operation of 240 V and a maximum rated parallel operation of 100 A, as per the Keysight N6705.
The Keysight N6761A powers devices under test from a modular system, on the R&D bench in the N6705 DC power analyzer and in automated test systems on N6700 mainframes, with the same module in both.
The Keysight N6761A needs a mainframe. The N6705C DC power analyzer mainframe holds 1 to 4 modules with a total available output power of 600 W, and the module can also be ordered installed in an N6715C system as N6761A-ATO.
In an N6705 DC power analyzer, the Keysight N6761A output can be turned on or off with delays from no delay to one thousand seconds of delay in one-millisecond increments, driven by built-in arbitrary waveforms such as sine, step, ramp and pulse, and captured on the scope or data logger; logged data can be exported to a CSV file.
The Keysight N6761A factory options from the data sheet, with what each one adds, are listed on the Options tab; the relay options disconnect the output, including the sense leads, when the output is turned off.
The Keysight N6761A sources power into a device. An electronic load does the opposite and absorbs power from a source such as a power supply or battery.
The Keysight N6761A is built to power a device and measure what it delivers. A source/measure unit is built for precise measurement while sourcing, including very low currents, and can also sink current.
Specifications are from the manufacturer's data sheet (Keysight Modular Power Solutions, Modular Power System Mainframes and Modules, 5992-1857EN, August 10, 2026) and data sheet (Keysight NP2-Class DC Power Analyzer, N6705 DC Power Analyzer, 5992-1880EN, October 8, 2026) and data sheet (Option 2UA Microamp Measurement Option for the N6760 Precision DC Power Modules, 5989-7972EN, July 31, 2014). Questions? Contact your Test Architect.
Updated 2026-11-25
Model No
Keysight
Condition
Factory New
Manufacturer
Keysight
Dcsup_amps
1.5 A
Dcsup_volts
50 V
Dcsup_watts
50 W
Plugin_type
DC Power Module
DC power analyzer mainframe.
Low-Profile Modular Power System mainframes.
Low-Profile Modular Power System mainframes.
Low-Profile Modular Power System mainframes.
761
Output disconnect relays.
2UA
200 μA measurement range.
UK6
Commercial calibration with test results data.
1A7
ISO 17025 calibration certificate.
5 V, 10 A, 50 W DC power module.
8 V, 6.25 A, 50 W DC power module.
20 V, 2.5 A, 50 W DC power module.
35 V, 1.5 A, 50 W DC power module.
60 V, 0.8 A, 50 W DC power module.
100 V, 0.5 A, 50 W DC power module.
5 V, 20 A, 100 W DC power module.
8 V, 12.5 A, 100 W DC power module.
20 V, 5 A, 100 W DC power module.
35 V, 3 A, 100 W DC power module.
60 V, 1.6 A, 100 W DC power module.
100V, 1A, 100W DC power module.
50 V, 5 A, 50 W high-performance autoranging DC power module.
50 V, 10 A, 100 W high-performance autoranging DC power module.
20 V, 50 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).
60 V, 20 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).
20 V, 50 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).
60 V, 17 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).
50 V, 3 A, 100 W precision DC power module.
20 V, 50 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots).
60 V, 20 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots).
20 V, 50 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots).
60 V, 17 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots).
20 V, 15 A, 300 W DC power module.
35 V, 8.5 A, 300 W DC power module.
60 V, 5 A, 300 W DC power module.
100 V, 3 A, 300 W DC power module.
150 V, 2 A, 300 W DC power module.
20 V, ± 3 A, 20 W source/measure unit.
20 V, ± 3 A, 20 W source/measure unit.
± 20 V, ± 3 A, 20 W source/measure unit.
N6783A-BAT
8 V, 3 A, 24 W battery charge/discharge module.
N6783A-MFG
6 V, 3 A, 18 W mobile communications module.
20 V, +/-8A, 80 W source/measure unit.
20 V, +/-8A, 80 W source/measure unit.
60 V, 20 A, 100 W DC electronic load.
60 V, 40 A, 200 W DC electronic load.