The Keysight N6702C is the automated test mainframe of the N6700 modular power system, with 1 to 4 outputs in a 1U chassis. The same modules also run in the N6705C DC power analyzer on the bench.
The Keysight N6702C sequences its outputs on and off with delays, slews voltage at a programmed rate, treats up to four channels as one synchronized virtual channel for parallel operation, and measures the voltage and current of every module.
| Parameter | Value |
|---|---|
| Total available output power | 1200 W |
| Modules | Holds 1 to 4 modules |
| AC line sensing | When you first turn on the N6702C 1200 W MPS mainframe, the mainframe automatically senses the power available from the AC line. If the AC line voltage is such that the resulting current would exceed a standard AC outlet rating, the mainframe automatically scales back the available output power to prevent overloading the AC line. |
| Height | 1U (rack unit) high |
| Air vents | It features side air vents (no top or bottom air vents), allowing other instruments to be mounted directly above or below it. |
| Measurement | The N6700 modules come standard with built-in voltage and current measurement to simplify the wiring and design of an ATE system. |
| Power management | allow you to allocate mainframe power to the outputs where it is needed |
| Modules that occupy two module slots | N6753A–N6756A, N6763A–N6766A, and N6792A |
| Empty slots | For proper operation, you must fill any empty module slots with filler panels. When configuring a mainframe with less than four filled module slots, you MUST order a filler panel kit. Each kit contains three filler panels. Each filler panel fills one empty module slot. |
| Rack mounting | If you are rack-mounting your N6700, you MUST order the rack-mount kit. |
| Rack mount kit | This kit provides all the necessary hardware to rackmount one N6700 mainframe in only 1U of rack space. This rack-mount kit includes front rack ears and rear supports, which replace standard rack rails and/or slides. Note that standard rack rails or slides are not compatible with the N6700 because of its 1U size and airflow requirements. |
| Parameter | Value |
|---|---|
| Triggering | The N6700 Low-Profile MPS mainframe features hardware trigger-in/trigger-out signals, enabling the N6700 to be synchronized with external events. |
| Interfaces | GPIB, USB 2.0, and 10/100 Base-T Ethernet LAN interfaces |
| LXI compliance | Class C |
| GPIB | SCPI – 1993, IEEE 488.2 compliant interface |
| USB 2.0 | Requires Keysight IO Library Version M.01.01 or 14.0 and up |
| 10/100 LAN | Requires Keysight IO Library Version L.01.01 or 14.0 and up |
| Web control | The N6700 can be controlled via a standard web browser. The N6700 features a web server that provides web pages for monitoring, controlling, and configuring the MPS. |
| Security | When used in systems running GPIB, the LAN and/or USB interfaces can be disabled for extra security. Also, all non-volatile RAM data and settings can be cleared from the front panel. |
| Drivers | The N6700 comes with both VXIplug&play drivers and IVI-COM drivers. |
| Programming language | The N6700 supports SCPI (Standard Commands for Programmable Instruments). |
| Front panel | You can have confidence that the N6700 is working correctly because you can view the settings and actual output values on all four outputs simultaneously. |
| Model | Total available output power | Power consumption | Net weight, N6700C with 4 modules (typical) |
|---|---|---|---|
| N6700C | 400 W | 1000 VA (N6700C) | 12.73 kg/28 lbs. |
| N6701C | 600 W | 1440 VA (N6701C) | 11.82 kg/26 lbs. |
| N6702C (this page) | 1200 W | 1440 VA (N6702C @ < 180 VAC input); 2200 VA (N6702C @ > 180 VAC input) | 14.09 kg/31 lbs. |
The Keysight N6702C has 1200 W total available output power. When the installed modules' ratings add to more than that, power management lets you allocate mainframe power to the outputs where it is needed.
The Keysight N6702C delivers its full 1200 W from AC mains above 180 VAC; when connected to 100-180 VAC mains, internal circuits limit the power to modules to a maximum of 600 W.
The Keysight N6702C has four module slots, and the N6753A–N6756A, N6763A–N6766A, and N6792A each occupy two of them. Any empty slot must be filled with a filler panel from an N6708A filler panel kit, and rack mounting needs the N6709C rack mount kit.
The modules that fit the Keysight N6702C, its required accessories, the other low-profile mainframes and its power cords are listed on the Options tab, with links to their pages.
| Parameter | Value |
|---|---|
| Module protection | Each N6700 module is protected against overvoltage, overcurrent, and overtemperature. A fault condition in one module can be detected within 10 microseconds by other modules, allowing them to be quickly shut down to prevent hazardous conditions on your Device Under Test (DUT). |
| Output sequencing | Each DC power module or electronic load can be individually set to turn on or off with a delay. By adjusting the delay times and then commanding the N6700 to turn on, you can set the N6700 modules to sequence on in a particular order. |
| Sequencing across mainframes | For applications that require more than four DC power or electronic load modules to be sequenced, this output sequencing can be extended across multiple N6700 mainframes. When the I/O ports on the rear panel of the mainframes are wired together, a pair of synchronization signals can be sent between mainframes, allowing the output sequences of all mainframes to be synchronized. This capability is supported by N6700C, N6701C, and N6702C mainframes. |
| Programmable voltage slew | from its maximum up/down programming speed to its slowest change of up to 10 seconds |
| Electronic load slew | For the electronic load family, slew control is available for voltage, current, resistance, or power. |
| Series operation | To increase available voltage and power, similarly rated outputs can be operated directly in series on power supply modules. |
| Virtual channels (parallel operation) | This firmware-based feature allows the N6700 system to treat up to four channels as a single, synchronized channel. |
| Parameter | Value |
|---|---|
| Power consumption | 1440 VA (N6702C @ < 180 VAC input); 2200 VA (N6702C @ > 180 VAC input) |
| Net weight, N6702C with 4 power modules | 14.09 kg/31 lbs. |
| Height/width/depth | 44.45 mm/432.5 mm/611.9 mm; 1.75 in./17.03 in./24.09 in. |
| AC mains of 100-180 VAC | When connected to 100-180 VAC mains, internal circuits limit the power to modules to a maximum of 600 W. |
| Fan speed control | To reduce acoustic noise, the N6700 mainframes employ fan speed control. When operating at less than full output power, the cooling fans spin more slowly and generate less noise. |
| Universal AC input | The N6700 features a universal input that operates from 100-240 V, 50/60 Hz, 400 Hz. There are no switches to set or fuses to change when switching from one voltage standard to another. The AC input employs power factor correction. |
| Quick disconnects | Each power module has quick disconnects mechanism for easy system setup and maintenance. |
| Operating environment | Indoor use, installation category II (for AC input), pollution degree 2 |
| Temperature range | 0 °C to 55 °C (output current is derated 1% per °C above 40 °C ambient temperature) |
| Relative humidity | Up to 95% |
| Altitude | Up to 2000 meters |
| Input ratings | ~ 100 VAC – 240 VAC; 50/60/400 Hz |
| Power factor | 0.99 @ nominal input and rated power |
The Keysight N6702C holds 1 to 4 modules, and each module is one output; up to four channels can also be combined as one virtual channel.
The Keysight N6702C total available output power is 1200 W, shared by the installed modules through power management; it delivers the full 1200 W from AC mains above 180 VAC, and on 100-180 VAC mains internal circuits limit the power to modules to a maximum of 600 W.
The Keysight N6702C has GPIB, USB 2.0 and 10/100 Base-T Ethernet LAN interfaces, LXI Class C compliance, control from a standard web browser, VXIplug&play and IVI-COM drivers, and SCPI programming.
The Keysight N6702C is 1U (rack unit) high and mounts with the N6709C rack mount kit; standard rack rails or slides are not compatible because of its 1U size and airflow requirements.
The Keysight N6702C powers and loads devices in automated test systems for R&D, design validation and manufacturing, with several outputs in one 1U mainframe.
The Keysight N6702C needs 1 to 4 modules, ordered separately and listed on the Options tab, an N6708A filler panel kit when fewer than four slots are filled, and the N6709C rack mount kit for rack mounting.
The Keysight N6702C is a 1U mainframe for automated test systems, and the N6705C is a bench mainframe with a large front-panel display; both take the same modules.
Specifications are from the manufacturer's data sheet (Keysight Modular Power Solutions, Modular Power System Mainframes and Modules, 5992-1857EN, August 10, 2026) and data sheet (Keysight NP2-Class DC Power Analyzer, N6705 DC Power Analyzer, 5992-1880EN, October 8, 2026). Questions? Contact your Test Architect.
Updated 2026-11-25
Model No
Keysight
Condition
Factory New
Manufacturer
Keysight
Dcsup_watts
1200 W
5 V, 10 A, 50 W DC power module.
8 V, 6.25 A, 50 W DC power module.
20 V, 2.5 A, 50 W DC power module.
35 V, 1.5 A, 50 W DC power module.
60 V, 0.8 A, 50 W DC power module.
100 V, 0.5 A, 50 W DC power module.
5 V, 20 A, 100 W DC power module.
8 V, 12.5 A, 100 W DC power module.
20 V, 5 A, 100 W DC power module.
35 V, 3 A, 100 W DC power module.
60 V, 1.6 A, 100 W DC power module.
100V, 1A, 100W DC power module.
50 V, 5 A, 50 W high-performance autoranging DC power module.
50 V, 10 A, 100 W high-performance autoranging DC power module.
20 V, 50 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).
60 V, 20 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).
20 V, 50 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).
60 V, 17 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots).
50 V, 1.5 A, 50 W precision DC power module.
50 V, 3 A, 100 W precision DC power module.
20 V, 50 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots).
60 V, 20 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots).
20 V, 50 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots).
60 V, 17 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots).
20 V, 15 A, 300 W DC power module.
35 V, 8.5 A, 300 W DC power module.
60 V, 5 A, 300 W DC power module.
100 V, 3 A, 300 W DC power module.
150 V, 2 A, 300 W DC power module.
20 V, ± 3 A, 20 W source/measure unit.
20 V, ± 3 A, 20 W source/measure unit.
± 20 V, ± 3 A, 20 W source/measure unit.
N6783A-BAT
8 V, 3 A, 24 W battery charge/discharge module.
N6783A-MFG
6 V, 3 A, 18 W mobile communications module.
20 V, +/-8A, 80 W source/measure unit.
20 V, +/-8A, 80 W source/measure unit.
60 V, 20 A, 100 W DC electronic load.
60 V, 40 A, 200 W DC electronic load.
Rack mount kit.
Filler panel kit.
Low-profile modular power system mainframe, 400 W.
Low-profile modular power system mainframe, 600 W.
DC power analyzer mainframe.
OL1
Full documentation on CD-ROM and printed user guide.
900
Power cord, United Kingdom, P/N 8120-1351.
901
Power cord, Australia, New Zealand, P/N 8120-1369.
902
Power cord, Europe, Korea, P/N 8120-1689.
903
Power cord, USA, Canada, 120 V, P/N 8120-4383.
904
Power cord, USA, Canada, 240 V, P/N 8120-0698.
906
Power cord, Switzerland, P/N 8120-2104.
912
Power cord, Denmark, P/N 8120-2956.
917
Power cord, South Africa, India, P/N 8120-4211.
918
Power cord, Japan, 100 V, P/N 8120-5342.
919
Power cord, Israel, P/N 8120-6800.
920
Power cord, Argentina, P/N 8120-6869.
921
Power cord, Chile, P/N 8120-6980.
922
Power cord, China, P/N 8120-8376.
927
Power cord, Thailand, Brazil, P/N 8120-8871.
929
Power cord, Japan, 200 V, P/N 8121-1392. Note: This option is available only on model N6702C.