Keysight N3302A 60V/30A 150W DC Electronic Load Module (Pre-Owned)

Keysight N3302A 60V/30A 150W DC Electronic Load Module (Pre-Owned)

Regular price $1,200
Sale price $1,200 Regular price
In Stock
Shipping calculated at checkout.
Calibrations
Unit
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

🎓 Request a Quote To Get An EDU Discount

Key Features At A Glance

The Keysight N3302A is an N3300 Series DC electronic load module rated 0–60 V, 0–30 A and 150 W at 40 °C, with constant current, constant voltage and constant resistance modes, for the N3300A and N3301A mainframes.

  • Input voltage rating: 0–60 V
  • Input current rating: 0–30 A
  • Maximum power @ 40 °C: 150 W
  • Typical minimum operating voltage @ full scale current: 1.2 V
  • Constant current high range accuracy: 0.1% + 10 mA
  • Current measurement low range accuracy: 0.05% + 3 mA
  • Current slew rate, slow band: 500–25 kA/s
  • Mainframe slots required: one slot
View full details

What the Keysight N3302A is and what it is used for

The Keysight N3302A is a DC electronic load module that installs in a slot of an N3300A or N3301A mainframe and absorbs power from a power supply, battery charger or DC to DC converter under test, in constant current, constant voltage or constant resistance mode. Its 16-bit voltage, current and power measurement system uses individual but linked current and voltage measurement systems.

The N3300 Series loads operate with full stability down to zero volts. For manufacturing test, downloaded “Lists” of command sequences execute independent of the computer, rising and falling slew rates are controlled separately, and the built-in transient generator operates in all modes. On the bench, the standard connector accepts an unterminated wire and may be hand-tightened.

Keysight N3302A key specifications

Input ratings

Conditions: at 25 °C ± 5 °C

Keysight N3302A: Input ratings (data sheet 5980-0232E p.4)
Parameter Value
Input voltage rating 0–60 V
Input current rating 0–30 A
Maximum power @ 40 °C 150 W
Maximum power derating (Table A-1 note 1) Maximum continuous power available is derated linearly from 100% of maximum at 40 °C, to 75% of maximum at 55 °C.

Specified current at low voltage operation

Keysight N3302A: Specified current at low voltage operation (data sheet 5980-0232E p.4)
Parameter Value Conditions
Specified current @ low voltage operation, 2.0 V 30 A at 25 °C ± 5 °C
Specified current @ low voltage operation, 1.5 V 22.5 A at 25 °C ± 5 °C
Specified current @ low voltage operation, 1.0 V 15 A at 25 °C ± 5 °C
Specified current @ low voltage operation, 0.5 V 7.5 A at 25 °C ± 5 °C
Specified current @ low voltage operation, 0 V 0 A at 25 °C ± 5 °C
Typical minimum operating voltage @ full scale current 1.2 V typically, under normal operating conditions

Constant current mode

Conditions: at 25 °C ± 5 °C; accuracy is ± (% of reading + fixed offset), 1000 samples

Keysight N3302A: Constant current mode (data sheet 5980-0232E p.5)
Parameter Value
Constant current, low range/high range 3 A/30 A
Constant current regulation 10 mA
Constant current low range accuracy 0.1% + 5 mA
Constant current high range accuracy 0.1% + 10 mA

Constant voltage mode

Conditions: at 25 °C ± 5 °C; accuracy is ± (% of reading + fixed offset), 1000 samples

Keysight N3302A: Constant voltage mode (data sheet 5980-0232E p.5)
Parameter Value
Constant voltage, low range/high range 6 V/60 V
Constant voltage regulation 5 mV
Constant voltage low range accuracy 0.1% + 3 mV
Constant voltage high range accuracy 0.1% + 8 mV

Constant resistance mode

Conditions: at 25 °C ± 5 °C

Keysight N3302A: Constant resistance mode (data sheet 5980-0232E p.5)
Parameter Value
Constant resistance range 1 (I > 10% of current rating) 0.067–4 Ω
Constant resistance range 2 (I > 1% of current rating) 3.6–40 Ω
Constant resistance range 3 (I > 0.1% of current rating) 36–400 Ω

Measurement accuracy

Conditions: at 25 °C ± 5 °C; accuracy is ± (% of reading + fixed offset), 1000 samples; DC current accuracy applies 30 seconds after input current is applied

Keysight N3302A: Measurement accuracy (data sheet 5980-0232E p.5)
Parameter Value
Current measurement, low range/high range 3 A/30 A
Current measurement low range accuracy 0.05% + 3 mA
Current measurement high range accuracy 0.05% + 6 mA
Voltage measurement, low range/high range 6 V/60 V
Voltage measurement low range accuracy 0.05% + 3 mV
Voltage measurement high range accuracy 0.05% + 8 mV
Power measurement accuracy 0.1% + 0.4 W

Programmable slew rate

Conditions: typical (supplemental characteristic)

Keysight N3302A: Programmable slew rate (data sheet 5980-0232E p.6)
Parameter Value
Current slew rate, slow band 500–25 kA/s
Current slew rate, fast band ≥3 V 50 k–2.5 MA/s
Current slew rate, fast band <3 V 50 k–250 kA/s
Voltage slew rate, slow band 1 k–50 kV/s
Slew rate bands (Table A-2 note 1) Slew rate bands are the ranges of programmable slew rates available.
Below 3 V (Table A-2 note 1) Below 3 volts, the maximum bandwidth of the electronic load is reduced by a factor of ten to one.

Ripple and noise

Conditions: typical (supplemental characteristic)

Keysight N3302A: Ripple and noise (data sheet 5980-0232E p.7)
Parameter Value
Voltage ripple and noise (rms), 20 Hz–10 MHz 5 mV rms

Programmable short and open

Conditions: typical (supplemental characteristic)

Keysight N3302A: Programmable short and open (data sheet 5980-0232E p.6)
Parameter Value
Programmable short, maximum 66 mΩ
Programmable short, typical 40 mΩ
Programmable open ≥ 20 kΩ

Control and programming

Keysight N3302A: Control and programming (data sheet 5980-0232E p.3, 8)
Parameter Value
Control GPIB, RS232, and manual use of the front panel
Command set SCPI (Standard Commands for Programmable Instruments)
Analog programming and monitoring ports for those applications that utilize nonstandard interfaces, require custom waveforms, or utilize process control signals
Lists Custom waveforms can also be created by downloading a “List” of load parameters.
Command processing time (average time for the output voltage to change after a GPIB command) 3 ms for discrete commands; 1 ms for list commands
List dwell range 0 - 10 s
List dwell resolution 1 ms
List dwell accuracy 5 ms
Software driver VXIplug&play

Transient generator

Keysight N3302A: Transient generator (data sheet 5980-0232E p.3, 8)
Parameter Value
Transient generator built-in transient generator, which operates in all modes
Transient generator frequency range 0.25 Hz - 10 kHz
Transient generator frequency accuracy 0.5%
Transient generator duty cycle range 3 to 97% (0.25 Hz - 1 kHz); 6 to 94% (1 kHz - 10 kHz)
Transient generator duty cycle accuracy 1%
Transient generator pulse width 50 μs ± 1% to 4 seconds ± 1%

Compare the Keysight N3302A with the other electronic load modules

Keysight N3302A: compare electronic load modules (data sheet 5980-0232E p.3, 4, 8)
Model Input voltage rating Input current rating Maximum power @ 40 °C Mainframe slots required Net weight
N3302A (this page) 0–60 V 0–30 A 150 W one slot 2.7 kg (6 lb)
N3303A 0–240 V 0–10 A 250 W one slot 2.7 kg (6 lb)
N3304A 0–60 V 0–60 A 300 W one slot 2.7 kg (6 lb)
N3305A 0–150 V 0–60 A 500 W 2 slots 4.6 kg (10 lb)
N3306A 0–60 V 0–120 A 600 W 2 slots 4.6 kg (10 lb)
N3307A 0–150 V 0–30 A 250 W one slot 2.7 kg (6 lb)

What decides whether the Keysight N3302A fits

Input ratings: does the Keysight N3302A cover the source under test?

The Keysight N3302A accepts 0–60 V and 0–30 A, with 150 W maximum power at 40 °C; maximum continuous power is derated linearly from 100% of maximum at 40 °C, to 75% of maximum at 55 °C. The source's voltage and current must both sit inside these ratings, and their product inside the power rating.

Low voltage: how much current can the Keysight N3302A sink near zero volts?

The Keysight N3302A specified current at low voltage operation is 30 A at 2.0 V, 15 A at 1.0 V, 7.5 A at 0.5 V and 0 A at 0 V. Typically, under normal operating conditions, the load can sink its maximum current down to 1.2 V, and the N3300 Series loads operate with full stability down to zero volts.

Transient tests: how quickly can the Keysight N3302A change its load?

The Keysight N3302A programmable current slew rate is 500–25 kA/s in the slow band. In the other band it is 50 k–2.5 MA/s at 3 V and above and 50 k–250 kA/s below 3 V, because below 3 volts the maximum bandwidth of the electronic load is reduced by a factor of ten to one. Rising and falling slew rates are controlled separately, and the built-in transient generator operates in all modes.

Short and open: can the Keysight N3302A test protection circuits?

The Keysight N3302A programmable short is 66 mΩ maximum and 40 mΩ typical, and its programmable open is ≥ 20 kΩ.

Connections: standard connector or Option UJ1?

The Keysight N3302A standard connector accepts an unterminated wire and may be hand-tightened, and the data sheet describes it as designed for bench applications and short-term automated tests. Option UJ1 8 mm screw connectors take wires terminated with insulated ring terminals, up to AWG 4 wire, with multiple wires on each screw terminal for parallel load connections, and are designed for test systems.

Rules of thumb (not specifications)

Voltage, current and power envelope. DC power = voltage × current. The required voltage and current, including any start-up peak, must both lie inside the stated ranges, and their product inside the stated power — on autoranging outputs the power limit is lower than maximum voltage × maximum current. Rule of thumb, not a specification.

Example with the Keysight N3302A: The Keysight N3302A accepts 0–60 V and 0–30 A with 150 W maximum power; 60 V × 30 A = 1,800 W, more than its 150 W rating, so at 60 V the current is limited to about 2.5 A (150 W ÷ 60 V).

Keysight N3302A options and what they change

The Keysight N3302A options and accessories, and the other mainframes and modules of the series, are listed on the Options tab.

What you need with the Keysight N3302A

Keysight N3302A: Mainframe fit (data sheet 5980-0232E p.3)
Parameter Value
Mainframe slots required one slot
N3300A mainframe full rack width; 6 slots
N3301A mainframe half rack width; 2 slots
Module mix Any assortment of the 6 different modules can be configured into these mainframes, up to the slot capacity.
Parallel operation Electronic load modules can be operated in parallel to provide additional current sinking capability.

Keysight N3302A safety and limits

Keysight N3302A: Floating voltage and remote sensing (data sheet 5980-0232E p.8)
Parameter Value
DC floating voltage (output terminals from chassis ground) up to ± 300 VDC
Remote sensing 5 V DC between sense and load input

Other Keysight N3302A specifications

Programming and readback resolution

Conditions: typical (supplemental characteristic)

Keysight N3302A: Programming and readback resolution (data sheet 5980-0232E p.6)
Parameter Value
Programming resolution, constant current mode (low/high range) 0.05/0.5 mA
Programming resolution, constant voltage mode (low/high range) 0.1/1 mV
Readback resolution, current (low/high range) 0.05/0.5 mA
Readback resolution, voltage (low/high range) 0.1/1 mV

Resistance slew rate

Conditions: typical (supplemental characteristic)

Keysight N3302A: Resistance slew rate (data sheet 5980-0232E p.6)
Parameter Value
Resistance range 1 slew rate, slow band 44–1125 Ω/s
Resistance range 1 slew rate, fast band ≥3 V 2250–34 kΩ/s
Resistance range 1 slew rate, fast band <3 V 2250–3.4 kΩ/s
Resistance range 2 slew rate, slow band 440–11.25 kΩ/s

Analog programming and monitor accuracy

Conditions: typical (supplemental characteristic)

Keysight N3302A: Analog programming and monitor accuracy (data sheet 5980-0232E p.7)
Parameter Value
External analog programming, voltage programming accuracy (all ranges) 0.5% + 12 mV
External analog programming, current programming accuracy (all ranges) 0.25% + 4.5 mA
External monitor port, voltage monitor accuracy 0.25% + 12 mV
External monitor port, current monitor accuracy 0.1% + 4.5 mA

Analog programming and monitor ports

Keysight N3302A: Analog programming and monitor ports (data sheet 5980-0232E p.8)
Parameter Value
Analog programming bandwidth 10 kHz rms (-3 db frequency)
Analog programming voltage Voltage: 0 - 10 V; Current: 0 - 10 V
Analog monitor ports Voltage: 0 - 10 V; Current: 0 - 10 V

Measurement time

Keysight N3302A: Measurement time
Number of samples or points Measurement time Additional fixed offset (in addition to measurement accuracy)
1000 samples (default) 20 ms none
200 samples 10 ms < 6%
100 samples 9 ms < 10%
20 points 7 ms < 30%
< 20 points 7 ms > 30%

Digital and trigger ports

Keysight N3302A: Digital and trigger ports (data sheet 5980-0232E p.8)
Parameter Value
Digital/Trigger inputs Vil = 0.9 V max at Iil = -1 mA; Vih - 3.15 V min (pull-up resistor on input)
Digital/Trigger outputs Vol = 0.72 V max at Iol = 1 mA; Voh = 4.4 V min at Ioh = -20 μA

Kept in the data sheet

Keysight N3302A: Kept in the data sheet
Specification Where in the data sheet
Constant resistance range 4 (I > 0.01% of current rating) Data sheet p.5, Table A-1
Programming resolution, constant resistance mode Data sheet p.6, Table A-2
Voltage slew rate, fast band ≥3 V Data sheet p.6, Table A-2
Resistance range 2 slew rate, fast bands Data sheet p.6, Table A-2
Resistance range 3 and range 4 slew rates Data sheet p.6, Table A-2
Current ripple and noise (rms/peak to peak), 20 Hz–10 MHz Data sheet p.7, Table A-2

Weight

Keysight N3302A: Weight (data sheet 5980-0232E p.8)
Parameter Value
Net weight 2.7 kg (6 lb)
Shipping weight 4.1 kg (9 lb)

Keysight N3302A questions and answers

What is the load input voltage range of the Keysight N3302A?

The Keysight N3302A input voltage rating is 0–60 V, and its constant voltage low range/high range is 6 V/60 V.

What is the load input current range of the Keysight N3302A?

The Keysight N3302A input current rating is 0–30 A, and its constant current low range/high range is 3 A/30 A.

What is the load power rating of the Keysight N3302A?

The Keysight N3302A maximum power is 150 W at 40 °C. Maximum continuous power is derated linearly from 100% of maximum at 40 °C, to 75% of maximum at 55 °C.

What are the load operating modes of the Keysight N3302A?

The Keysight N3302A operates in constant current, constant voltage and constant resistance modes and has a programmable short and a programmable open; its constant resistance range 1 (I > 10% of current rating) is 0.067–4 Ω.

Does the Keysight N3302A have a dynamic load mode?

Yes, the Keysight N3302A has a built-in transient generator, which operates in all modes, with a frequency range of 0.25 Hz - 10 kHz and a pulse width of 50 μs ± 1% to 4 seconds ± 1%; custom waveforms can also be created by downloading a “List” of load parameters.

How accurate are the Keysight N3302A measurements?

The Keysight N3302A measures current with an accuracy of 0.05% + 3 mA on the low range and 0.05% + 6 mA on the high range, and voltage with 0.05% + 3 mV and 0.05% + 8 mV; its power measurement accuracy is 0.1% + 0.4 W. Each figure is ± (% of reading + fixed offset) with 1000 samples, at 25 °C ± 5 °C.

What is the Keysight N3302A used for?

The Keysight N3302A loads power supplies, battery chargers, multiple output DC power supplies and DC to DC converters under test, in manufacturing test systems or on the bench, and measures their voltage, current and power.

What else is needed to use the Keysight N3302A?

The Keysight N3302A needs an N3300 Series mainframe, the N3300A (full rack width, 6 slots) or the N3301A (half rack width, 2 slots), in which it requires one slot. The mainframes and the other modules are listed on the Options tab.

How does the Keysight N3302A compare with the other N3300 Series modules?

The Keysight N3302A is rated 0–60 V, 0–30 A and 150 W and requires one slot; the other N3300 Series modules differ in these ratings and slot needs, as the compare table on this page shows.

How is an electronic load different from a DC power supply?

The Keysight N3302A absorbs power from a source under test; a DC power supply does the opposite and delivers power to a device.

Specifications are from the manufacturer's data sheet (Keysight N3300 Series DC Electronic Loads Data Sheet, 5980-0232E, August 2, 2014). Questions? Contact your Test Architect.

Updated 2026-11-25

Model No

Keysight

Condition

Pre-Owned

Dc_load_volts

0–60 V

Load_amps

0–30 A

Load_watts

150 W

Manufacturer

Keysight Technologies

N3300A

The N3300A mainframe is full rack width. It has 6 slots.

N3301A

The N3301A mainframe is half rack width. It has 2 slots.

UJ1

8 mm screw terminal connector.

N3303A

The N3302A (150 watts), N3303A (250 watts), N3307A (250 Watts) and N3304A (300 watts) each require one slot.

N3304A

The N3302A (150 watts), N3303A (250 watts), N3307A (250 Watts) and N3304A (300 watts) each require one slot.

N3305A

The N3305A (500 watts) and the N3306A (600 watts) each require 2 slots.

N3306A

The N3305A (500 watts) and the N3306A (600 watts) each require 2 slots.

N3307A

The N3302A (150 watts), N3303A (250 watts), N3307A (250 Watts) and N3304A (300 watts) each require one slot.