The Agilent 6812B is an AC power source/analyzer. As an AC source it combines the capabilities of a power amplifier and an arbitrary waveform generator, so it can simulate normal waveforms and many types of distorted power waveforms; its built-in power analyzer combines the capabilities of a multimeter, oscilloscope, harmonic analyzer and power analyzer.
The Agilent 6812B can also produce DC power, either alone or as a DC offset to an AC waveform. Its transient generation system simulates sophisticated and repeatable AC line disturbances such as brownouts, dropouts and sags, for design verification either in an R&D environment or on the manufacturing test floor.
The Agilent 6812B with Option 020 adds a second power analyzer, equivalent in specifications and capabilities to the standard analyzer, so a test can measure at both the AC input and the AC output of a device such as a UPS, with all four measurement channels inherently synchronized with the output waveform.
Conditions the data sheet sets for its specifications:
| Parameter | Value |
|---|---|
| Number of phases | 1 |
| Output power (maximum) | 750 VA |
| Output voltage, rms (maximum) | 300 V |
| Output current, rms (maximum) | 6.5 A |
| Peak current, repetitive and non-repetitive (maximum) | 40 A |
| Crest factor | 6 |
| Load power factor capability | 0 to 1 |
| DC output power (maximum) | 575 W |
| DC output voltage (maximum) | ± 425 V |
| DC output current (maximum) | 5.0 A |
| Parameter | Value | Conditions |
|---|---|---|
| Output frequency range | DC; 45 Hz to 1 kHz | note 1 |
| Constant voltage ripple and noise | –60 dB | 20 kHz to 10 MHz; relative to full scale |
| Line regulation (% of full scale) | 0.1% | — |
| Load regulation (% of full scale) | 0.5% | — |
| Maximum total harmonic distortion | 0.25% at 50/60 Hz | — |
| Maximum total harmonic distortion, worst case | 1% worst case | 45 to 1 kHz |
Note 1: Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a digitization rate of 250 µs per point. Frequency content of the measured signal must be limited to 4 kHz or less to avoid aliasing effects.
| Parameter | Value | Conditions |
|---|---|---|
| RMS voltage programming accuracy, 45 to 100 Hz | 0.15% + 0.3 V | at 25 ° ± 5 °C; % of output + offset; 45 to 100 Hz |
| RMS voltage programming accuracy, > 100 to 500 Hz | 0.5% + 0.3 V | at 25 ° ± 5 °C; % of output + offset; > 100 to 500 Hz |
| RMS voltage programming accuracy, > 500 to 1000 Hz | 1% + 0.3 V | at 25 ° ± 5 °C; % of output + offset; > 500 to 1000 Hz |
| DC voltage programming accuracy | 0.1% + 0.5 V | at 25 ° ± 5 °C |
| Frequency programming accuracy | 0.01% + 10 µHz | at 25 ° ± 5 °C |
| Parameter | Value | Conditions |
|---|---|---|
| Rms voltage measurement accuracy (45 - 100 Hz) | 0.03% + 100 mV | at 25 ° ± 55 °C (note 1) |
| DC voltage measurement accuracy | 0.05% + 150 mV | at 25 ° ± 55 °C (note 1) |
| Rms current measurement accuracy (45 - 100 Hz), high range | 0.05% + 10 mA | at 25 ° ± 55 °C (note 2) |
| Rms current measurement accuracy (45 - 100 Hz), low range | 0.05% + 1.5 mA | at 25 ° ± 55 °C (note 2) |
| Power (VA) measurement accuracy (45-100 Hz), high range | 0.1% + 1.5 VA + 12 mVA/V | at 25 ° ± 55 °C (note 2) |
| Power (VA) measurement accuracy (45-100 Hz), low range | 0.1% + 1.5 VA + 1.2 mVA/V | at 25 ° ± 55 °C (note 2) |
| Power (watts) measurement accuracy (45-100 Hz), high range | 0.1% + 0.3 W + 12 mW/V | at 25 ° ± 55 °C (note 2) |
| Power (watts) measurement accuracy (45-100 Hz), low range | 0.1% + 0.3 W + 1.2 mW/V | at 25 ° ± 55 °C (note 2) |
| Frequency measurement accuracy | 0.01% + 0.01 Hz | at 25 ° ± 55 °C |
| Power factor measurement accuracy | 0.01 | at 25 ° ± 55 °C |
| Current magnitude (low range), fundamental | 0.03% + 1.5 mA | at 25 ° ± 55 °C |
| Current magnitude (low range), harmonics 2-49 | 0.03% + 1 mA + 0.2%/kHz | at 25 ° ± 55 °C |
| Current magnitude (high range), fundamental | 0.05% + 5 mA | at 25 ° ± 55 °C |
| Current magnitude (high range), harmonics 2-49 | 0.05% + 3 mA + 0.2%/kHz | at 25 ° ± 55 °C |
Note 1: Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a digitization rate of 250 µ seconds per point. Frequency content of the measured signal must be limited to 4 kHz or less to avoid aliasing effects.
Note 2: Select low measurement range for improved accuracy (10:1) for lower power measurements.
The Agilent 6812B is rated 750 VA maximum output power at 300 V rms and 6.5 A rms, with 40 A repetitive and non-repetitive peak current and a crest factor of 6. For rectifier-type loads that draw high peak current, check the peak current and crest factor as well as the rms rating.
The Agilent 6812B DC ratings are ± 425 V, 5.0 A and 575 W, either alone or as a DC offset to an AC waveform.
The Agilent 6812B output frequency range is DC and 45 Hz to 1 kHz, which includes the nominally 400 Hz power of avionics equipment. The product may be operated between DC and 45 Hz subject to certain deratings.
The Agilent 6812B maximum total harmonic distortion is 0.25% at 50/60 Hz and 1% worst case from 45 to 1 kHz. Constant voltage ripple and noise (20 kHz to 10 MHz) is –60 dB relative to full scale, line regulation is 0.1% and load regulation 0.5% of full scale.
The Agilent 6812B measures rms, DC and AC + DC voltage and current, peak voltage and current, real, apparent and reactive power, harmonic amplitude and phase up to the 50th harmonic, and THD, with 16-bit precision. Option 020 adds a second power analyzer for measurements at both the AC input and the AC output of the device under test.
The Agilent 6812B has programmable output impedance of 0 – 1 Ω resistance and 20 µh – 1 mh inductance, which lets a UPS designer verify product stability over different AC line impedances.
Voltage, current and power envelope. DC power = voltage × current. The required voltage and current, including any start-up peak, must both lie inside the stated ranges, and their product inside the stated power — on autoranging outputs the power limit is lower than maximum voltage × maximum current. Rule of thumb, not a specification.
Example with the Agilent 6812B: In DC mode the Agilent 6812B is rated ± 425 V, 5.0 A and 575 W; 425 V × 5 A = 2,125 W, more than its 575 W rating, so at 425 V the current is limited to about 1.35 A (575 W ÷ 425 V).
Power factor and current. For the same real power at the same voltage, current scales as 1 ÷ power factor. Power-measurement accuracy usually worsens at low power factor. Rule of thumb, not a specification.
Example with the Agilent 6812B: The Agilent 6812B power (watts) measurement accuracy is 0.1% + 0.3 W + 12 mW/V on the high range and 0.1% + 0.3 W + 1.2 mW/V on the low range, and its load power factor capability is 0 to 1.
Measuring high efficiency. Efficiency is output power ÷ input power, so both measurement uncertainties combine. As efficiency approaches 100%, the uncertainty of the loss figure becomes many times the instrument's basic accuracy. Rule of thumb, not a specification.
Example with the Agilent 6812B: With Option 020 the Agilent 6812B measures at both the AC input and the AC output of a device, with a second analyzer equivalent in specifications and capabilities to the standard analyzer, so the power accuracy of both (0.1% + 0.3 W + 12 mW/V on the high range) enters an efficiency figure.
The power analyzer, output, line-voltage, line-cord and documentation options, rack-mount kits and accessories for the Agilent 6812B are listed on the Options tab.
| Parameter | Value | Conditions |
|---|---|---|
| Input voltage range (VAC) | 87 to 106 VAC; *104 to 127 VAC; 174 to 220 VAC; 191 to 254 VAC | * default factory setting |
| Maximum input current (rms) | 28 A (100 VAC); 24 A (120 VAC); 15 A (200/208 VAC); 13 A (230 VAC) | measured at low line |
| Input power (maximum) | 2500 VA/1400 W | measured at high line |
| Input frequency | 47 to 63 Hz | — |
| Parameter | Value |
|---|---|
| Isolation to ground | 300 Vrms/425 VDC |
| Protection | overcurrent, overvoltage, overpower and overtemperature protection; output disconnect relays; remote inhibit capability (quickly disabling the output of the AC power source/analyzers via a TTL signal) |
| Parameter | Value |
|---|---|
| Average programming accuracy, rms current (% of output + offset) | 1.2% + 50 mA |
| Average programming resolution, rms voltage | 125 mV |
| Average programming resolution, DC voltage | 250 mV |
| Average programming resolution, overvoltage programming (OVP) | 2 V peak |
| Average programming resolution, rms current | 4 mA |
| Average programming resolution, peak current | 25 mA |
| Average programming resolution, output frequency | 10 µHz |
| Average measurement resolution, rms voltage | 10 mV |
| Average measurement resolution, rms current | 2 mA |
| Programmable output impedance, resistance | 0 – 1 Ω |
| Programmable output impedance, inductance | 20 µh – 1 mh |
| Remote sense capability | Up to 1 Vrms can be dropped across each load lead |
| Parameter | Value |
|---|---|
| Net weight | 28.2 kg (62 lb) |
| Shipping weight | 31.8 kg (70 lb) |
| Software driver | VXIplug&play |
| Parameter | Value |
|---|---|
| Series | 6800B Series |
| AC source | combine the capabilities of a power amplifier and an arbitrary waveform generator |
| Waveforms | simulate normal waveforms and many types of distorted power waveforms |
| Built-in power analyzer | combines the capabilities of a multimeter, oscilloscope, harmonic analyzer and power analyzer |
| DC output | produce DC power, either alone or as a DC offset to an AC waveform |
| Transient generation | the transient generation system to simulate sophisticated and repeatable AC line disturbances |
| AC power irregularities named | Brownouts, dropouts, sags, and other irregularities |
| Where used | either in an R&D environment or on the manufacturing test floor |
| Command set | SCPI command set |
| Avionics | well suited for testing equipment intended for use in the avionics industry which operate at nominally 400 Hz |
| UPS testing | commands are available to enable calculation of UPS transfer time, and the phase difference between the UPS input and output voltage |
| Programmable output impedance (use) | verify product stability over a wide range of AC line impedance |
| Parameter | Value |
|---|---|
| Option 020 | provides an additional power analyzer |
| Option 020 analyzer specifications | equivalent in specifications and capabilities to the standard analyzer |
| Option 020 synchronization | Measurements on all four measurement channels (AC source output voltage and current, and dual power analyzer voltage and current inputs) are inherently synchronized with the AC power source/analyzers output waveform |
| Option 020 without source power | can even be used for tests where the AC power source/analyzer is not providing power |
The Agilent 6812B is a single-phase source rated 750 VA, 300 V rms and 6.5 A rms, with 40 A repetitive and non-repetitive peak current, a crest factor of 6 and a load power factor capability of 0 to 1.
The Agilent 6812B produces AC from 45 Hz to 1 kHz as well as DC; the product may be operated between DC and 45 Hz subject to certain deratings.
The Agilent 6812B produces DC power either alone or as a DC offset to an AC waveform, rated ± 425 V, 5.0 A and 575 W.
The Agilent 6812B rms voltage programming accuracy at 25 ° ± 5 °C is 0.15% + 0.3 V from 45 to 100 Hz, 0.5% + 0.3 V above 100 to 500 Hz and 1% + 0.3 V above 500 to 1000 Hz; DC voltage programming accuracy is 0.1% + 0.5 V and frequency programming accuracy 0.01% + 10 µHz.
The Agilent 6812B rms voltage measurement accuracy (45 - 100 Hz) is 0.03% + 100 mV; rms current accuracy is 0.05% + 10 mA on the high range and 0.05% + 1.5 mA on the low range, and power (watts) accuracy is 0.1% + 0.3 W + 12 mW/V on the high range and 0.1% + 0.3 W + 1.2 mW/V on the low range. The measurement accuracy table states its temperature condition.
The Agilent 6812B with Option 020 has a second power analyzer, equivalent in specifications and capabilities to the standard analyzer; it can even be used for tests where the AC power source/analyzer is not providing power, and measurements on all four channels are inherently synchronized with the output waveform.
The Agilent 6812B is used for static testing at the line voltages and frequencies a product will meet worldwide, dynamic testing with AC line transients, specialty testing such as current harmonic measurement and custom waveforms, UPS testing, and testing avionics equipment that operates at nominally 400 Hz.
The Agilent 6812B has overcurrent, overvoltage, overpower and overtemperature protection, output disconnect relays and a remote inhibit that disables the output via a TTL signal. The 6812B is programmed over GPIB with the SCPI command set and a VXIplug&play software driver.
The Agilent 6812B maximum input power, measured at high line, is 2500 VA/1400 W at an input frequency of 47 to 63 Hz. The input voltage ranges and maximum input currents are listed under AC input ratings; the input range is set by option, so check which option a unit has before connecting it.
The Agilent 6812B net weight is 28.2 kg (62 lb) and its shipping weight 31.8 kg (70 lb).
The Agilent 6812B accessories include the 1CM003A rack mount flange kit and the 1CP002A flange and handle kit, both 132.6 mm H (3U); support rails are required, such as the E3663AC support rails for Agilent rack cabinets.
The Agilent 6812B with Option 026 has a 26 Volt, 0.1 A auxiliary reference output, 45 to 100 Hz only.
The Agilent 6812B simulates AC line power at programmed voltages and frequencies, including distorted waveforms and line disturbances, and measures the power the device draws; a DC power supply delivers a set DC voltage or current.
Specifications are from the manufacturer's data sheet (Agilent 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB Data Sheet, 5990-9309EN, June 19, 2014). Questions? Contact your Test Architect.
Updated 2026-11-25
Model No
Agilent
Condition
Used
Manufacturer
Agilent
Frequency
1 kHz
Phase
1
Power (va)
750 VA
Volts
300 V
020
Dual power analyzer option.
026
26 Volt, 0.1 A auxiliary 45 to 100 Hz only, reference output (6812B and 6813B).
0B3
Printed service manual.
0L1
Printed user’s, programming, and quick start guides; printed reference card.
100
(6811B and 6812B only) 87 to 106 VAC (100 VAC nominal), 47-63 Hz, Japan only.
120
104-127 VAC (120 VAC nominal), 47-63 Hz.
208
(6811B and 6812B only) 174 to 220 VAC (208 VAC nominal), 47-63 Hz.
230
191 to 254 VAC (230 VAC nominal), 24-63 Hz.
831
12 AWG, 200 to 240 VAC, unterminated (6812B, 6813B only).
833
1.5 mm2 wire size, 200 to 240 VAC, unterminated (6812B only).
834
10 AWG, 100 to 120 VAC, unterminated (6812B only).
841
Line cord with NEMA L6-20P; 20 A, 250 V plug (6812B only).
845
Line cord with IEC 309; 16 A, 220 V plug (6812B only).
846
Line cord with NEMA L6-30P; 30 A, 120 V plug (6812B only).
847
Line cord with CEE 7/7; 16 A, 220 V plug (6812B only).
848
Line cord with BS 546; 15 A, 240 V plug (6812B only).
1CM003A
Rack mount flange kit 132.6 mm H (3U) – two flange brackets. Support rails required.
1CP002A
Rack mount flange and handle kit 132.6 mm H (3U) – two brackets and front handles. Support rails required.
E3663AC
Support rails for Agilent rack cabinets.
Request A Quote