Skip to product information
1 of 1

Agilent U2701A 100 MHz USB Modular Oscilloscope (Pre-Owned)

Agilent U2701A 100 MHz USB Modular Oscilloscope (Pre-Owned)

Calibrations

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Agilent U2701A 100 MHz USB Modular Oscilloscope (Pre-Owned)

Key Features At A Glance

  • Bandwidth from 100 MHz (U2701A) to 200 MHz (U2702A) across the series
  • Up to 1 GSa/s maximum sample rate (two channels interleaved; 500 MSa/s per channel)
  • Up to 32 Mpts standard waveform memory (up to 64 Mpts in single-shot)
  • Dual-play function: run standalone or in a modular product chassis cardcage
  • Hi-Speed USB 2.0 interface; USBTMC 488.2 class device for automated systems
  • Advanced triggering including edge, pulse width, and TV
  • Four waveform math functions including FFT standard
  • Compact, portable module design
View full details

The Agilent U2701A and U2702A are USB modular oscilloscopes that combine a set of essential features for analyzing designs in an affordable way. They are offered in two bandwidths — 100 MHz on the U2701A and 200 MHz on the U2702A — and acquire simultaneously on two channels, Ch 1 and Ch 2. Each unit includes standard debugging capability such as advanced triggering, automatic measurements, and math functions including FFT.

An oscilloscope captures voltage waveforms over time, letting an engineer see a signal's amplitude, frequency, timing, and shape. The U2701A and U2702A connect to a PC through a Hi-Speed USB 2.0 interface for easy plug-and-play setup, which makes them suited to the education, design validation, and manufacturing industries. The dual-play function lets a unit serve as a standalone instrument or scale up within a cardcage alongside additional scopes or other Agilent USB modular products, providing a complete solution for system development.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

Agilent Technologies was established in 1999 as a spin-off of Hewlett-Packard's test and measurement business. In 2014, Agilent's electronic measurement business was separated again to form Keysight Technologies, under which this product line was subsequently offered.

Compare Other Models in This Series

The U2701A/U2702A USB Modular Oscilloscope family consists of two models that share a common architecture and differ primarily in bandwidth. Both acquire simultaneously on two channels, reach up to 1 GSa/s when channels are interleaved, and carry up to 32 Mpts of standard waveform memory.

Both models offer the dual-play function, allowing each to run as a standalone instrument over Hi-Speed USB 2.0 or to be installed in a modular product chassis for system expansion. Advanced triggering, four math functions with FFT, and the Agilent Measurement Manager software are standard across the family.

Each model in this family is listed on its own dedicated product page, with pricing matched to the pre-owned unit you select. Choose the model whose bandwidth fits your application, then open the listing for your preferred condition.

The two models are separated by bandwidth: the U2701A provides DC to 100 MHz with a calculated rise time of 3.5 ns, while the U2702A provides DC to 200 MHz with a calculated rise time of 1.75 ns. Sample rate, memory depth, vertical resolution, and trigger capability are otherwise common to both.

The included probe tracks the bandwidth tier as well: the U2701A ships with 10:1 150 MHz passive probes (N2862A) and the U2702A ships with 10:1 300 MHz passive probes (N2863A). The comparison table below summarizes these per-model differences.

Model Bandwidth Rise Time Max Sample Rate
U2701A 100 MHz 3.5 ns 1 GSa/s
U2702A 200 MHz 1.75 ns 1 GSa/s

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • 12 V, 2 A AC/DC Power adapter
  • Power cord
  • USB Standard A to Mini-B interface cable
  • 2 x 10:1 Passive probe 150 MHz 1.2m, N2862A
  • L-Mount kit (used with modular product chassis)
  • Agilent Automation-Ready CD-ROM (contains the Agilent IO Libraries Suite)
  • Agilent USB Modular Products Quick Start Guide
  • Agilent USB Modular Products Reference CD-ROM
  • Agilent USB Modular Products Quick Reference Card
  • Certificate of Calibration

Product Core & Specifications

Specification Value
Vertical System: Oscilloscope Channels
Bandwidth (–3 dB) DC to 100 MHz
Scope channels Ch 1 and Ch 2 simultaneous acquisition
AC coupled 3.5 Hz to 100 MHz
Calculated rise time (= 0.35/bandwidth) 3.5 ns
Single-shot bandwidth 100 MHz
Range 2 mV/div to 5 V/div (1 MΩ)
Maximum input CAT I 30 Vrms, 42 Vpk
Offset range ±4 div (Example: ±8 mV on 2 mV/div; ±20 V on 5 V/div)
Dynamic range ±4 div
Input impedance 1 MΩ: ≈ 16 pF
Coupling AC, DC, Ground
BW limit ≈ 25 MHz
Standard probes 10:1 Passive probe 150 MHz 1.2 m
ESD tolerance ±2 kV
Noise peak-to-peak 3 mVpp
DC vertical offset accuracy ≤ 200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value; > 200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value
DC vertical gain accuracy ±4.0% of full scale
Scope channel triggering trigger sensitivity < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
Single-cursor accuracy ±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~2 LSB)}
Dual-cursor accuracy ±{DC vertical gain accuracy + 0.4% full scale (~1 LSB)}
Acquisition: Oscilloscope Channels
Real time sample rate — 2 channels interleaved 1 GSa/s
Real time sample rate — each channel 500 MSa/s
Standard memory depth — 2 channels interleaved (Normal / Single-shot) 32 Mpts / 64 Mpts
Standard memory depth — each channel (Normal / Single-shot) 16 Mpts / 32 Mpts
Vertical resolution 8 bits
Peak detection Yes
Averaging Any number from 1 to 999
Filter Sin(x)/x interpolation for time base 1 ns to 100 ns
Sweep modes Auto, normal, single
Horizontal
Range 1 ns/div to 50 s/div
Time base accuracy 20 ppm
Delay range Pre-trigger: –100 %; Post-trigger: +100 %
Modes Main, roll, XY
XY Yes
Reference position Center
Trigger System
Sources Ch 1, Ch 2, Ext (not applicable for TV trigger)
Modes Normal, single, auto trigger
Holdoff time 60 ns
Selections Edge, pulse width, TV
Edge Triggers on a rising or falling edge, alternating, or either edge of any source
Pulse width Triggers on a pulse width greater than, equal to, or less than a specified time limit, with time limits ranging from 16 ns to 10 s. Minimum lower limit: 8 ns; Minimum upper limit: 16 ns; Maximum pulse width setting: 10 s
TV Triggers on one of three standard television waveforms: NTSC, PAL, SECAM. TV trigger sensitivity: 0.6 division of sync signal. Modes supported include Field 1, Field 2, all fields, or any line within a field.
Autoscale Single-button automatic setup of all channels
Oscilloscope Channel Triggering
Range (internal) ±4 div from center screen
Coupling AC (< 15 Hz); LF reject (~ 35 kHz); HF reject (~ 35 kHz)
External (EXT) Triggering
Input impedance 1 MΩ: ≈ 16 pF
Maximum input CAT I 30 Vrms, 42 Vpk
Range DC coupling: trigger level ±1.25 V and ±2.5 V
EXT trigger pulse width > 2.5 ns
Trigger level sensitivity (±1.25 V range) DC to 100 MHz: 100 μV; > 100 MHz: 200 μV
Trigger level sensitivity (±2.5 V range) DC to 100 MHz: 250 μV; > 100 MHz: 500 μV
Display
Interpolation Sin(x)/x
Display types Dots and vectors
Persistence Off, infinite
Format XY, roll
Measurement Features
Automatic measurements Measurements are continuously updated. Cursors track last selected measurement.
Voltage Peak-to-peak, maximum, minimum, average, amplitude, top, base, Vrms, overshoot, preshoot, crest, standard deviation, cycle RMS, RMS AC
Time Frequency, period, +width, –width, +duty cycle, –duty cycle, rise time, fall time, delay, phase
Frequency Maximum peak
Cursors Modes: Manual; Type: Time, voltage and frequency (FFT); Measurements: DT, DV, frequency, Peak Scan (FFT), DPeak
Math functions Add, subtract, multiply, FFT, divide
FFT
Points 1250 points (for 500 ns and above)
Source of FFT Source channels 1 or 2
Window Hanning, Hamming, Blackman-Harris, Rectangular, Flattop
Noise floor –50 dB to –90 dB depending on averaging
Amplitude Display in dBV
Maximum frequency 250 MHz
General / Product Characteristics
Remote interface Hi-Speed USB 2.0; USBTMC 488.2 Class device
Power consumption +12 VDC, 2 A; Installation Category III
Operating temperature 0 °C to +50 °C
Operating humidity 20% to 85% RH (non-condensing)
Important: Maximum input is CAT I 30 Vrms, 42 Vpk. Under standalone use, measurement is limited to CAT I 30 Vrms; for high-voltage measurement up to CAT I 300 Vrms, the L-Mount kit must be installed on the module and screwed to the product chassis for proper grounding, and the provided 10:1 probes (N2862A/N2863A) must be used to avoid damaging the instrument.
Important: The Hi-Speed USB 2.0 / USBTMC 488.2 remote interface is compatible with Microsoft Windows operating systems only and requires a direct USB connection to the PC so the appropriate driver can be installed in the USB modular instrument.
Recommended pairing: use the Agilent U2781A USB Modular Product Chassis to operate the oscilloscope in a cardcage with additional modules, per the dual-play configuration.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Keysight

Osc_ch

2

Osc_freq

100 MHz

Osc_r

1 MΩ

Osc_sampl

1 GSa/s