Applications
- Hardware Debug and Verification
- Processor/Bus Debug and Verification
- Embedded Software Integration, Debug and Verification
Specifications
TLA700 PC Characteristics
- Operating System: Microsoft Windows 2000 Professional
- Processor: Intel Pentium III
- Chipset: Intel 815E
- DRAM: 512 MB SDRAM
- Display Memory: 4 MB
- Dual Monitor Support: 1600 x 1200 Resolution
- Sound: Built-in PC speaker transducer; multimedia sound can be added via PC Card interface
- Replaceable Hard Disk Drive: 40 GB
- CD ROM: Internal 8/4/32 CD-RW.
- Floppy Disk Drive: Built-in 3.5 in. 1.44 MB drive
- Front-Panel Display: Size: 10.4 in. diagonal
- Type: Active-matrix color TFT LCD with backlight
- Resolution: 800 x 600
- Colors: 16.8 M (true color)
- Simultaneous Display Capability: Both the front-panel and one external display can be used simultaneously at 800 x 600 resolution.
- Front-panel Knobs: Special function knobs for instrument control.
- Front-panel QWERTY Keypad: Mini-QWERTY keypad and Hex keypad.
- Front-panel Pointing Device: Trackball.
TLA700 External Peripheral Interfaces (TLA715 and TLA721)
- External Display Port Type: (2) Female DB15 connectors.
- External Display Resolution: Up to 1600 x 1200 non-interlaced at 256 colors, for both primary and secondary displays.
- External Display Compatibility: DDC2B (dynamic display configuration 2).
- External Keyboard Port Type: PS2 mini-DIN.
- External Mouse Port Type: PS2 mini-DIN.
- Parallel Interface Port Type: IEEE 1284-C connector (comes standard with adapter to female DB25 connector).
- Parallel Interface Modes: Centronics mode, EPP (Extended Parallel Port), ECP (Microsoft high-speed mode).
- Serial Interface Port Type: Male DB9.
- PC Card (CardBus) Slot Types: Two slots, two PC Card Type I/II or one PC Card Type III.
- USB Port: Two (2)
Integrated View (iView™) Capability
- TLA mainframe configuration requirements - TLA714/720/715/721 Series mainframes, TLA520x instruments, and TLA6XX instruments
- TLA App S/W V 4.1 or greater
- 256 MB DRAM Minimum, 512 MB recommended
- Number of TDS oscilloscopes that can be connected to a TLA system: 1
External Oscilloscopes Supported
- TDS1002, TDS1012, TDS2002, TDS2012, TDS2014, TDS2022, TDS2024
- TDS3012, TDS3014, TDS3032, TDS3034, TDS3052, TDS3054
- TDS3012B, TDS3014B, TDS3032B, TDS3034B, TDS3052B, TDS3054B
- TDS5032, TDS5034, TDS5052, TDS5054, TDS5104
- TDS6404, TDS6604
- TDS7054, TDS7104, TDS7154, TDS7404
- TDS684C, TDS694C
- CSA7154, CSA7404
- TDS754C, TDS784C, TDS724D, TDS754D, TDS784D, TDS794D
- TLA Connections: USB, Trigger In, Trigger Out, Clock Out
- TDS Connections: GPIB, Trigger In, Trigger Out, Clock In (when available)
- Setup: iView™ external oscilloscope wizard automates setup
- Data Correlation: After TDS oscilloscope acquisition is complete, the data is automatically transferred to the TLA and time correlated with the TLA acquisition data
- Deskew: TDS and TLA data is automatically deskewed and time correlated when using the iView™ external oscilloscope cable
- iView™ External Oscilloscope Cable Length: 2 m
Symbolic Support
- Number of Symbols/Ranges: Unlimited (limited only by amount of virtual memory available on TLA).
- Object File Formats Supported:
- IEEE695
- OMF 51, OMF 86, OMF 166, OMF 286, OMF 386
- COFF
- Elf/Dwarf 1 and 2
- Elf/Stabs
- TSF (if your software development tools do not generate output in one of the above formats, TSF or the Tektronix symbol file, a generic ASCII file format is supported. The generic ASCII file format is documented in the TLA User Manual). If a format is not listed, please contact your local Tektronix representative.
External Instrumentation Interfaces
- System Trigger Output: Asserted whenever a system trigger occurs (TTL-compatible output, back-terminated into 50 Ω)
- System Trigger Input: Forces a system trigger (triggers all modules) when asserted (TTL-compatible, edge-sensitive, falling-edge latched)
- External Signal Output: Can be used to drive external circuitry from a module's trigger mechanism (TTL-compatible output, back-terminated into 50 Ω)
- External Signal Input: Can be used to provide an external signal to arm or trigger any or all modules (TTL-compatible, level-sensitive)
Power
- TLA721 and TLA7XM: Voltage range/frequency: 90-250 VAC at 45-66 Hz, 100-132 VAC at 360-440 Hz
- Input current: 16.5 A maximum at 90 VAC (70 A surge)
- Power consumption: 1,450 W maximum
Environmental
- Temperature - Operating: +5 °C to +50 °C
- Nonoperating: -20 °C to +60 °C
- Humidity: 20% to 80%
- Operating: ≤30 °C; 80% relative humidity (29 °C maximum wet bulb temperature)
- Nonoperating: 8% to 80% (29 °C maximum wet bulb temperature)
- Altitude: Operating: -1,000 ft. to 10,000 ft. (-305 meters to 3,050 meters)
- Safety: UL3111-1, CSA1010.1, EN61010-1, IEC61010-1
TDS configuration requirements: The iView™ cable does not fully connect to the TDS1000/2000 Series oscilloscopes without a GPIB extender. Tektronix recommends a standard GPIB cable as an extender, or order a cable extender (National Instruments part number 181638-1). TDS2CMAX Communications Extension Module is required for iView capability on any TDS1000/2000 Series. TDS3GM GPIB/RS232 Interface Module required for iView capability on any TDS3000 series. TDS3GV GPIB/RS232/VGA Interface Module required for iView capability on any TDS3000B series. If using TLA7Axx iConnect with a TDS6404, TDS6604, TDS7154, TDS7404, CSA7154 or CSA7404 oscilloscope, four TCA-BNC connectors are required to be compatible with BNC cables from the TLA7Axx module.
The TLA721 mainframe is a modular mainframe that accept TLA7Axx and TLA7Lx/Mx/Nx/Px/Qx logic analyzer modules, as well as TLA7PG2 pattern generator modules. The TLA721 can be used in conjunction with a TLA7XM expansion mainframe to provide solutions for large numbers of buses and high channel count requirements.
The TLA721 mainframe is built on a Microsoft® Windows® 2000 Professional PC platform that offers a familiar work environment. TLA applications operate like any other PC application.
The TLA721 mainframe comes standard with dual display capability for extended desktop viewing, in addition to an internal CD-RW, hard disk and PC card slots for expansion. A replaceable hard disk is standard on both mainframes, ideal for security or enabling individual team members to store personal setups and data. Trigger in/out connections provide an interface to other external instrumentation, such as TDS oscilloscopes, for correlating measurement results.
The image is a representation of selection. See specifications for product details.