Skip to content
The Siglent SDS5106X HD is a 1 GHz, 6-channel digital oscilloscope from the SDS5000X HD Series — part of Siglent's Super Phosphor Oscilloscope family. In summary, this is a 12-bit-resolution, 5 GSa/s-sample-rate instrument intended for general benchtop signal capture, mixed-signal debug, serial-bus decoding, and power-supply characterization.
The SDS5106X HD is used to capture, view, measure, and analyze electrical waveforms up to 1 GHz. Typical applications: embedded system debug, power-rail characterization, motor and inverter waveform inspection, audio and sensor signal analysis, education, and serial-bus decoding for the protocols listed below.
Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay, Video (HDTV), Zone Trigger. Serial: I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester, ARINC429.
Data analysis functions include: Search, Navigate, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis, Double Pulse Test. Acquisition and measurement: Sequence up to 170,000 segments; 50+ auto measurements; 8 Math traces (8 Mpts FFT, Filter, +, −, ×, ÷, ∫, d/dt, √) with formula editor; hardware Average, Hi-Res, Mask Test. The SDS5106X HD delivers 5 GSa/s real-time sampling and 2.5 Gpts/ch (max) of record length — sufficient to capture long-duration events while preserving timebase resolution for zoom inspection.
The SDS5000X HD's combination of 12-bit ADCs and 8-channel options is unique at this price band — comparable instruments from Tektronix or Keysight that support >4 channels at 1 GHz with 12-bit resolution typically run 2–3× higher. The natural choice for power-supply control loops, motor inverters, and 3-phase work where channel count and resolution matter equally.
The SDS5106X HD acquisition and analysis specifications are listed below. Where the SDS5000X HD Series family shares architecture across its members, model-specific differences are concentrated in bandwidth, channel count, and (for HD-series) ADC vertical resolution.
| Specification | Value |
|---|---|
| Analog Channels | 6 |
| Bandwidth | 1 GHz |
| Max Sample Rate | 5 GSa/s |
| Vertical Resolution (ADC) | 12-bit |
| Record Length | 2.5 Gpts/ch (max) |
Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay, Video (HDTV), Zone Trigger. Serial: I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester, ARINC429.
Sequence up to 170,000 segments; 50+ auto measurements; 8 Math traces (8 Mpts FFT, Filter, +, −, ×, ÷, ∫, d/dt, √) with formula editor; hardware Average, Hi-Res, Mask Test.
Data analysis: Search, Navigate, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis, Double Pulse Test.
Unit Options below are multi-select — choose any combination that applies. Some options are software-licensed; others require additional hardware (e.g., logic probe). Contact your Test Architect to confirm bundle pricing.
All Factory New Siglent oscilloscopes ship with a factory calibration and certificate as standard. Optional upgrade calibration paths (NIST Traceable, NIST Traceable with Full Data, ISO/IEC 17025 Accredited) can be added at the time of order — please specify your required calibration tier on the order, and ValueTronics will route the unit through the appropriate calibration lab prior to shipment.
This webpage was written by a human with an A.I. 'Intern', which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
SDS5106X
Condition
New
Manufacturer
Siglent
Request A Quote