The Anritsu MT9083 Series ACCESS Master is a family of handheld optical time domain reflectometers designed for installing and maintaining FTTx, CATV, LAN, access, and metro optical networks. The series consolidates OTDR, stabilized light source, optical power meter, visible light source, and optional IP test functions into a single compact instrument, eliminating the need to carry multiple separate test sets to the work site. Three performance tiers are available: the MT9083A general-purpose model, the MT9083B high-performance model, and the MT9083C ultra-high-performance model, each available in standard indoor or enhanced indoor/outdoor display variants.
The ACCESS Master is used for optical fiber construction, certification, fault location, and ongoing maintenance across both single mode and multimode fiber plants. Dedicated testing modes built into the firmware address specific tasks: Fault Locate mode automates parameter selection and returns end or break location for occasional users, Standard OTDR mode supports manual setup for experienced operators, and Construction mode provides a wizard-driven workflow for multi-wavelength cable acceptance with consistent file naming. Additional modes cover stabilized light source operation, optical loss test set measurements, visual fault location, and IP connection testing when the corresponding options are installed. The instrument also supports remote SCPI command operation for automated test integration and unmanned monitoring.
ValueTronics International stocks, inspects, and ships the MT9083 Series ACCESS Master from a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Each {{CONDITION}} unit moves through documented receiving, performance verification against the manufacturer's published OTDR specifications, and condition grading by technicians on site before it is offered for sale, so the configuration the buyer receives matches the configuration described in the listing. This in-house handling distinguishes ValueTronics from pass-through brokers and unverified marketplace listings where the seller has not physically tested the instrument.
The MT9083 Series ACCESS Master is organized into three performance tiers that share a common physical platform, user interface, and accessory ecosystem. The MT9083A is the general-purpose base model, the MT9083B is the high-performance tier with enhanced dynamic range and dual-mode High Resolution / Enhanced Range operation, and the MT9083C is the ultra-high-performance tier with the longest distance range, the highest dynamic range, and up to 150,001 sampling points.
Within each tier, the datasheet defines a numbered option suffix (for example -053, -057, -063) that specifies the wavelength configuration, fiber type, and whether the unit is single mode, multimode, or hybrid. Display variants are designated with a trailing '1' (MT9083A1, MT9083B1, MT9083C1) for the enhanced indoor/outdoor display; base part numbers without the '1' carry the standard indoor display. All tiers share the same external interfaces, data formats, and software options.
Each model linked below is its own product page with pre-owned-matched pricing and the option suffix called out in the title. Confirm the wavelength configuration, the optical connector type, and any installed software or hardware options on the specific listing before ordering — the MT9083 platform supports many factory-installed and retrofit options that materially change what the unit can measure.
The three tiers differ primarily in dynamic range, distance range, and sampling resolution. The MT9083A series provides up to 38.5 dB dynamic range (1310 nm, 20 µs pulse, 180 s averaging) and up to 200 km single mode distance range. The MT9083B series provides up to 42 dB dynamic range with dual-mode High Resolution / Enhanced Range operation and Enhanced Mode optimized for 1×64 PON characterization, also at up to 200 km. The MT9083C series provides up to 45 dB dynamic range, up to 300 km single mode distance range, up to 150,001 sampling points, and Enhanced Mode optimized for 1×128 PON characterization.
Wavelength configurations also differ across option suffixes within each tier. The -053 option provides 1310/1550 nm single mode and is common across all three tiers. The -055 option adds 1650 nm with integrated filter for live-fiber work. The -056 option adds 1490 nm for FTTx/PON verification.
| Model | Performance Tier | Wavelengths | Max Dynamic Range |
|---|---|---|---|
| MT9083A | General purpose (Base Model) | 780/850/1300/1310/1383/1490/1550/1625/1650 nm (varies by option) | Up to 38 dB |
| MT9083A1 | General purpose (Base Model) | 780/850/1300/1310/1383/1490/1550/1625/1650 nm (varies by option) | Up to 38 dB |
| MT9083B | High performance, 1x64 PON | 850/1300/1310/1383/1490/1550/1625/1650 nm (varies by option) | Up to 42 dB |
| MT9083B1 | High performance, 1x64 PON | 850/1300/1310/1383/1490/1550/1625/1650 nm (varies by option) | Up to 42 dB |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Item | Specification |
|---|---|
| Dimensions (without protector option 010) | 270 (W) × 165 (H) × 61 (D) mm / 10.6 × 6.5 × 2.4 inches |
| Weight (without protector) | 2.2 kg (4.8 lbs) including battery |
| Dimensions (with protector option 010) | 284 (W) × 200 (H) × 77 (D) mm / 11.2 × 7.9 × 3 inches |
| Weight (with protector) | 2.9 kg (6.4 lbs) including battery |
| Display | 6.5 inch TFT-LCD (640 × 480, with backlight, transparent type), enhanced indoor/outdoor optional |
| Interface | USB 1.1, Type A × 1 (memory), Type B × 1 (USB mass storage) |
| Data Storage | Internal memory: 440 MB (up to 1000 traces); External memory (USB): up to 30,000 traces with 512 MB |
| Power Supply | 12 VDC; 100 to 240 VAC, allowable input voltage range: 90 to 264 V, 50/60 Hz |
| Battery Type | Lithium ion |
| Battery Operating Time | 8 hours (typical, backlight off, sweeping halted at 25°C) |
| Battery Recharge Time | <5 hours (power off) |
| Power Saving Functions | Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes |
| Vertical Scale | 0.13, 0.33, 0.65, 1.3, 3.25, 6.5, 13 dB/div |
| IOR Setting | 1.400000 to 1.699999 (0.000001 steps) |
| Units | km, m, kft, ft, mi |
| Languages | User selectable (English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish) |
| Sampling Points | Normal: 5001; High density: 20001 or 25001 (MT9083A and B series), up to 150,001 (MT9083C series) |
| Sampling Resolution | 5 cm (min.) |
| Reflectance Accuracy | Single mode: ±2 dB; Multimode: ±4 dB |
| Distance Accuracy | ±1 m ±3 × measurement distance × 10⁻⁵ ± marker resolution (excluding IOR uncertainty) |
| Distance Range (SM) | 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200 km (MT9083A and B series, except 780 nm: 0.5, 1, 2.5 km); 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km (MT9083C series) |
| Distance Range (MM) | 0.5, 1, 2.5, 5, 10, 25, 50, 100 km |
| Testing Modes | Fault Locate, Standard OTDR, Construction OTDR, Light Source (CW/270 Hz/1 kHz/2 kHz), Loss Test Set (optional), Connector Video Inspection Probe, Visual Fault Locator (optional) |
| Fiber Event Analysis | Auto or manual, table format; User defined PASS/FAIL thresholds; Reflective/non-reflective: 0.01 to 9.99 dB; Reflectance: –70.0 to –20.0 dB; Fiber end/break: 1 to 99 dB; Up to 99 events; Macrobend detection |
| OTDR Trace Format | Telcordia universal SOR, issue 2 (SR-4731) |
| Real Time Sweep | 0.15 sec (low density resolution; except models 062, 068: 1 sec or less) |
| Loss Modes | 2 point loss, dB/km, 2 point LSA, splice loss, ORL |
| Averaging Modes | Timed (1 to 3600 sec.) |
| Other Functions | Live Fiber detect, Connection check, Trace overlay/comparison, Template function, USB keyboard support, Remote control (SCPI), Video output to PC |
| Operating Temperature | 0° to +40°C (MT9083A and B series), <80% (non-condensing); 0° to +45°C (MT9083C series), <80% (non-condensing) |
| Storage Temperature | –20° to +60°C, <80% (non-condensing) |
| Vibration | Conforming to MIL-T-28800E Class 3 |
| Dust Proof | MIL-T-28800E Class 2 |
| Drip Proof | IP51 (IEC 60529), JIS C 0920 TYPE I |
| EMC | EN61326-1, EN61000-3-2 |
| LVD | EN61010-1 |