The DAQ-9600 data acquisition system is a modularized data acquisition system with high flexibility and higher performance. The mainframe is equipped with 3 module slots and a built-in precision 6 1/2 digital DMM is the core of its test and measurement. 5 modules are available to meet different measurement needs. For the research and development of analyzing product characteristics or the production and manufacturing of system testing or fault diagnosis, a data acquisition system with flexibility and high performance can effectively fulfill different measurement requirements by expansion and change that make the overall test simpler, faster and more reliable.
Precise test and measurement
The test and measurement core of the DAQ-9600 is a 6 1/2-digit DMM, which has the functions and performance of an industrial-grade DMM. It can measure and convert 14 different input signals. In addition to high resolution, it also provides basic accuracy of 0.0035% DC voltage, 0.05% basic accuracy of AC voltage and 0.01% basic accuracy of resistance (within one-year calibration period). The functions of this DMM can be used with general-purpose modules (DAQ-900/ DAQ-901), multi-function module (DAQ-903) and high-voltage and high-current module (DAQ-909). All multiplexer modules use "disconnect before connect" scanning to ensure that only one channel (or a pair of channels) is closed at a time.
Built-in signal conditioning
The DAQ -9600 does not rely on external or plug-in signal conditioning modules to handle functions other than DC voltage, which not only greatly reduces noise and errors generated by external wiring from entering the system, and improves reliability. At the same time, it does not have unnecessary cables, wire distribution boxes and signal conditioning components that makes configuration quicker and easier. Taking temperature measurement as an example, the measurement of thermocouples is often accompanied by the Seebeck effect (the thermoelectric phenomenon in which the temperature difference between two different electrical conductors or semiconductors causes a voltage difference between two substances). All DAQ-9600 modules provide cold junction compensation (except DAQ-904) to ensure maximum accuracy for all channels measuring thermocouples, avoiding the use of temperature extension wires with external cold junctions, which will increase noise and errors generated by external wiring into the system.
Internal memory and USB storage
The DAQ-9600 can store the measurement results without connecting to a PC with the non-volatile memory capacity of 100k readings. Users can store the measurement results inside the system first, and then connect to a PC to collect data. In addition, for larger memory capacity, the DAQ-9600 also supports the USB storage function, which can directly record data to an external USB flash drive, or copy the data of the internal non-volatile memory to the flash drive for follow-up analysis.
Simplify data collection and analysis
The DAQ-9600 provides LAN, USB and GPIB (optional) to meet the most suitable and customary remote control interface requirements. Users can be benefitted from the free data collection software (DAQ-Data Logger) to easily and quickly set up tests, acquire and store measurement data, and perform real-time observation and analysis during the measurement process. If LAN is used as the interface, it can be easily connected to the company network to collect measurement data and store it in the central database. It can also use a common web browser (such as Chrome, IE) through the built-in graphical web interface to configure test and measurements, define and execute scan lists to reduce the time spent on programming.
GUARANTEED QUALITY
Payment Terms
We accept payment prior to shipping
Domestic: Payment methods accepted:
Illinois buyers pay appropriate sales tax based on county (Please contact ValueTronics before making payment).
International: Payment methods accepted:
All international buyers must request an invoice via email from ValueTronics to include shipping costs before finalizing purchase.
Return Policy
Shipping & Handling
Domestic: Varies by listing (Includes Insurance)
International: Buyer pays all shipping costs.
Estimated Delivery: We can usually ship orders within 5 business days of payment receipt. If we can not meet this expectation you will be promptly notified. Many items can be shipped same day. Contact us for more information.
Shipping: All items are professionally packed to arrive undamaged. If a purchase is received in damaged condition, you must immediately file a claim with the freight carrier and report the same to us. All packaging materials must be saved for inspection by the carrier representatives.
Feedback
We pride ourselves on exceptional customer service. With 28 years experience in the industry we proudly extend that expertise to our customers.We respond quickly to all comments and concerns with urgency and professionalism.
We ask that if you have any problems with your purchase, please try to resolve it with us directly before leaving us a Neutral or Negative rating on eBay. We have built a sterling reputation based on highly satisfied customers.
If you do leave us negative feedback before attempting to resolve the problem with us directly, we reserve the right to deem that as final resolution to that matter and will not accept a return or issue a refund.
Model No
Instek
Hey👋Let's start with your email