Skip to content

The Tektronix FCA3000 and FCA3100 Series are timer/counter/analyzers that pack many different measurement functions into one feature-rich instrument. The series comes standard with deep internal memory and a fast 250k samples/s data transfer rate to internal memory, while a multi-parameter display shows auxiliary measurements alongside the main measurement so results can be read at a glance. Comprehensive analysis modes — measurement statistics, histograms, and trend plots — give an engineer the tools to analyze a signal quickly and accurately.
High resolution is critical for R&D and production testing on demanding designs, and the FCA Series is built to deliver fast, precise measurements for those applications. A zero dead-time measurement technique and continuous time-stamping of trigger events ensure correct Allan Deviation measurements — capabilities described as vital for mechanical and medical measurements where every single cycle must be measured. Limit-qualifying capability lets you isolate one cluster in a calculation, important for applications such as verifying the jitter of digital pulses that appear in discrete clusters in CD players or in HDB3-coded data.
ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, which lets us match the right instrument to an engineer's application and ship it promptly. That combination of held inventory and in-house verification is what stands behind each FCA-Series order.
Tektronix, founded in 1946, was acquired by Danaher Corporation in 2007 and became part of Fortive Corporation when Fortive was spun off from Danaher in 2016. The Tektronix brand has remained in continuous use throughout these corporate ownership changes.
The FCA3000 and FCA3100 Timer/Counter/Analyzer Series share a common architecture — deep internal memory, a 250k measurement/s capture rate, a multi-parameter graphical display, and SCPI/GPIB and USB connectivity — while differing in measurement resolution and the set of advanced functions each provides. Across both series, Input C frequency coverage is offered in 300 MHz, 3 GHz, and 20 GHz model variants.
The FCA3000 Series provides 100 ps single-shot time resolution and 3 mV voltage resolution, while the FCA3100 Series provides 50 ps single-shot time resolution and 1 mV voltage resolution. Both series deliver 12 digit/s frequency resolution and the same graphical analysis modes.
Each model below is its own dedicated product page with condition-matched pricing for the new configuration you select. Choose the frequency tier and series that fit your application, then review that model's page for its specific specifications and current availability.
The FCA3000 is the 300 MHz, 100 ps single-shot model of the series, pairing inputs A and B (DC to 300 MHz) with the series' standard analysis modes, multi-parameter display, and 750k-reading internal memory.
The comparison table that follows summarizes the differences between the two series. The FCA3100 Series adds functions not present on the FCA3000 Series: Totalize and Time Interval Error (TIE) measurements, a programmable pulse output, continuous measurements, and a talker-only GPIB/USB output. It also offers a larger 3.75M-reading internal memory versus 750k readings, finer 50 ps time and 1 mV voltage resolution versus 100 ps and 3 mV, and faster transfer rates (15k vs 5k readings/s in block mode; 650 vs 500 individually triggered measurements/s).
Within each series, the models differ by Input C frequency coverage — 300 MHz, 3 GHz, or 20 GHz — with the 20 GHz models (FCA3020 and FCA3120) additionally supporting burst frequency and PRF measurements. Refer to each model's own row in the comparison table for the functions and ranges specific to that model.
| Model | Max Frequency | Single-shot Time Resolution | Voltage Resolution |
|---|---|---|---|
| FCA3020 | 20 GHz | 100 ps | 3 mV |
| FCA3000 | 300 MHz | 100 ps | 3 mV |
| FCA3003 | 3 GHz | 100 ps | 3 mV |
| FCA3100 | 300 MHz | 50 ps | 1 mV |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Frequency A, B, C | |
| Mode | Normal, Back-to-Back (FCA3100 Series) |
| Range (Input A, B) | 0.001 Hz to 300 MHz; 300-400 MHz in Manual Trigger mode |
| Range (Input C) | 100 MHz to 3 GHz or 300 MHz to 20 GHz |
| Resolution | 12 digits in 1 s measuring time (normal); 11 digits in 1 s measuring time (back-to-back) |
| Aux Parameters | Vmax, Vmin, Vp-p |
| Frequency Burst A, B, C (FCA3020 and FCA3120 – 20 GHz Only) | |
| Functions | Frequency in burst (in Hz), PRF (in Hz) |
| Range | Input A, B, C: See Frequency spec. |
| Minimum Burst Duration | Down to 40 ns |
| Minimum Pulses in Burst (Input A, B) | 3 (6 above 160 MHz) |
| Minimum Pulses in Burst (Input C) | 3 × prescaler factor |
| PRF Range | 0.5 Hz to 1 MHz |
| Start Delay | 10 ns to 2 s, 10 ns resolution |
| Aux Parameters | PRF |
| Period A, B, C | |
| Mode | Single, Average, Back-to-Back (FCA3100 Series) |
| Range (Input A, B) | 3.3 ns to 1000 s (single, average); 4.0 µs to 1000 s (back-to-back) |
| Range (Input C) | 10 ns down to 50 ps |
| Resolution | 100 ps (single); 12 digit/s avg. (FCA3000 Series). 50 ps (single); 12 digit/s avg. (FCA3100 Series) |
| Aux Parameters | Vmax, Vmin, Vp-p |
| Ratio A/B, B/A, C/A, C/B | |
| Range | (10⁻⁹) to 10¹¹ |
| Input Frequency (Input A, B) | 0.1 Hz to 300 MHz; 300-400 MHz in Manual Trigger mode |
| Input Frequency (Input C) | 3 or 20 GHz |
| Aux Parameters | Freq 1, Freq 2 |
| Time Interval A to B, B to A, A to A, B to B | |
| Range | Normal calculation: 0 ns to +10⁶ s; Smart calculation: –10⁶ s to +10⁶ s |
| Resolution | 100 ps single (FCA3000 Series); 50 ps single (FCA3100 Series) |
| Min Pulse Width | 1.6 ns |
| Smart Calculation | Smart Time Interval to determine sign (A before B or A after B) |
| Positive and Negative Pulse Width A, B | |
| Range | 2.3 ns to 10⁶ s |
| Min Pulse Width | 2.3 ns |
| Aux Parameters | Vmax, Vmin, Vp-p |
| Rise and Fall Time A, B | |
| Range | 1.5 ns to 10⁶ s |
| Trigger Levels | 10% and 90% of signal amplitude |
| Min Pulse Width | 1.6 ns |
| Aux Parameters | Slew rate, Vmax, Vmin |
| Time Interval Error (TIE) A, B | |
| Description | Normalized period back-to-back measurements, calculated as TIE(k) = k * TREF - ∑TI, when TI = Individual Period Back-to-Back and TREF = Reference Period Value. |
| Positive and Negative Duty Factor A, B | |
| Range | 0.000001 to 0.999999 |
| Frequency Range | 0.1 Hz to 300 MHz |
| Aux Parameters | Period, pulse width |
| Phase A Relative B, B Relative A | |
| Range | –180° to +360° |
| Resolution | Single cycle: 0.001° to 10 kHz, decreasing to 1° >10 MHz. Resolution can be improved by averaging (statistics) |
| Frequency Range | Up to 160 MHz |
| Aux Parameters | Freq (A), Va/Vb (in dB) |
| Totalize A, B (FCA3100 Series) | |
| Mode | Tot A, Tot B, Tot A+B, Tot A–B, Tot A/B |
| Range | 1 to 10¹⁰ counts |
| Frequency Range | Up to 160 MHz |
| Start Control | Manual, start arming |
| Stop Control | Manual, stop arming, timed |
| Aux Parameters | Other Totalize functions |
| Vmax, Vmin, Vp-p A, B | |
| Range | –50 V to +50 V, –5 V to +5 V (limited by max input voltage without damage, see Input A, B) |
| Frequency Range | DC, 1 Hz to 300 MHz |
| Mode | Vmax, Vmin, Vp-p |
| Resolution | 3 mV (FCA3000 Series); 1 mV (FCA3100 Series) |
| Uncertainty (5 V range, typical) DC, 1 Hz to 1 kHz | 1% + 15 mV |
| Uncertainty (5 V range, typical) 1 kHz to 20 MHz | 3% + 15 mV |
| Uncertainty (5 V range, typical) 20 to 100 MHz | 10% + 15 mV |
| Uncertainty (5 V range, typical) 100 to 300 MHz | 30% + 15 mV |
| Aux Parameters | Vmin, Vmax, Vp-p |
| Time Stamping A, B, C | |
| Description | Raw time-stamp data together with pulse counts on inputs A, B, or C, accessible through GPIB or USB only. |
| Max Sample Speed | See GPIB specifications |
| Max Frequency | 160 MHz |
| Time-stamp Resolution | 100 ps (FCA3000 Series); 50 ps (FCA3100 Series) |
Important: Maximum voltage without damage on Inputs A and B (1 MΩ): 350 V (DC + AC peak) to 440 Hz, falling to 12 V RMS at 1 MHz on the X1 setting; on the 50 Ω setting, 12 V RMS (unprotected input).
Important: Please specify power plug when ordering.
Important: Every FCA Series timer/counter/analyzer comes backed with a three-year standard warranty.
Important: Standard internal memory depth may vary by configuration or build; the datasheet's comparison table lists 3.5M results for the FCA3100 Series while the GPIB specification and feature list state 3.75M readings. Verify the installed depth on your instrument.
Important: Signal connection cables (e.g., BNC test cables) are not included in the standard delivery; the appropriate cables must be ordered separately (see Recommended Accessories and Software).
Recommended pairing: add the Tektronix TVA3000 TimeView modulation domain analysis software to extend the instrument into a high-performance modulation domain analyzer for capturing and analyzing fast frequency changes.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Tektronix
Condition
Factory New
Manufacturer
Tektronix
Freq_count_freq
20 GHz
TVA3000 Tektronix Software New
TVA3000
HCTEK4321 Tektronix Case New
HCTEK4321
Tektronix SIGEXPTE SignalExpress Tektronix Edition Professional Version Software
SIGEXPTE