Skip to content

The Keysight E4416A and E4417A are EPM-P series power meters that operate with the E-series E9320 family of peak and average power sensors for peak, average, and time-gated power measurements. The E4416A is a single-channel instrument, while the E4417A provides two measurement channels. In addition to the E9320 sensors, the EPM-P meters also operate with the 8480 and N8480 series, E-series CW, and the E9300 range of power sensors for average power measurements. Two measurement modes are provided: Normal mode, the default when using E9320 sensors, for peak, average, and time-related measurements; and Average only mode, intended primarily for average power measurements on low-level signals and used with the 8480, N8480, E-series CW, and E9300 sensors.
A power meter quantifies the RF or microwave power present at its sensor input and displays the result in absolute units (watts or dBm) or relative units (percent or dB). The EPM-P series adds predefined setups for common wireless standards — GSM900, EDGE, NADC, iDEN, Bluetooth, IS-95 CDMA, W-CDMA, and cdma2000 — simplifying configuration for those measurement tasks. With a 20 Msample/second continuous sampling rate and a 5 MHz video bandwidth, the system follows the power envelope of an input signal; because that envelope is, in some cases, set by the signal's modulation bandwidth, the video bandwidth is sometimes referred to as modulation bandwidth.
ValueTronics holds and stocks its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments offered here are inventory we keep on hand rather than items sourced after the fact. That combination lets engineers and labs source the right power meter and sensor configuration with confidence in both condition and availability.
Keysight Technologies traces its roots to Hewlett-Packard, whose test and measurement business was spun off as Agilent Technologies in 1999 and then established as the independent Keysight Technologies in 2014.
The EPM-P series pairs the E4416A and E4417A power meters with the E-series E9320 family of peak and average power sensors. The E4416A is a single-channel meter and the E4417A is a dual-channel meter; both share the same measurement modes, interfaces, and reference architecture. Measurement capability — frequency coverage, power range, and dynamic range — depends on which sensor is connected.
The E9320 sensors come in six models that differ in frequency coverage and video bandwidth. The E9321A, E9322A, and E9323A cover 50 MHz to 6 GHz, while the E9325A, E9326A, and E9327A cover 50 MHz to 18 GHz, with video bandwidths of 300 kHz, 1.5 MHz, and 5 MHz spanning the pairs.
Each new model below is its own dedicated product page with condition-matched pricing. Select the meter or sensor that fits your application, and review that page for its specific configuration and availability.
The primary meter difference is channel count: the E4416A provides a single measurement channel, while the E4417A provides two channels and adds a second recorder output for channel B. Net weight differs slightly (approximately 4.0 kg versus 4.1 kg), and the E4417A ships with two E9288A sensor cables versus one for the E4416A.
Across the E9320 sensors, the differences are frequency range and video bandwidth: the E9321A/E9322A/E9323A reach 6 GHz and the E9325A/E9326A/E9327A reach 18 GHz, with video bandwidths of 300 kHz, 1.5 MHz, and 5 MHz respectively. The comparison table that follows details the per-model frequency range, video bandwidth, and power range.
| Model | Type | Frequency Range | Video Bandwidth |
|---|---|---|---|
| E4416A | Power Meter | 9 kHz to 110 GHz, sensor dependent | 5 MHz |
| E4417A | Power Meter | 9 kHz to 110 GHz, sensor dependent | 5 MHz |
| E9321A | Power Sensor | 50 MHz to 6 GHz | 300 kHz |
| E9322A | Power Sensor | 50 MHz to 6 GHz | 1.5 MHz |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Frequency and Power Range | |
| Frequency range | 9 kHz to 110 GHz, sensor dependent |
| Power range | –70 to +44 dBm, sensor dependent |
| Single Sensor Dynamic Range | |
| E-series E9320 peak and average power sensors | 70 dB maximum (normal mode); 85 dB maximum (average only mode) |
| E-series CW power sensors | 90 dB |
| E-series E9300 average power sensors | 80 dB maximum |
| 8480 series sensors | 50 dB maximum |
| N8480 series sensors | 55 dB maximum |
| Display | |
| Display units (absolute) | Watts or dBm |
| Display units (relative) | Percent or dB |
| Display resolution | Selectable resolution of 1.0, 0.1, 0.01, 0.001 dB in logarithmic mode, or 1 to 4 significant digits in linear mode |
| Offset range | ± 100 dB in 0.001 dB increments, to compensate for external loss or gain |
| Video bandwidth | 5 MHz (set by meter and is sensor dependent) |
| Accuracy — Average Only Mode | |
| Absolute, logarithmic | ± 0.02 dB |
| Absolute, linear | ± 0.5% |
| Relative, logarithmic | ± 0.04 dB |
| Relative, linear | ± 1.0% |
| Accuracy — Normal Mode | |
| Absolute accuracy (log), calibration temperature ± 5 °C | ± 0.04 dB |
| Absolute accuracy (log), 0 to 55 °C | ± 0.08 dB |
| Absolute accuracy (linear), calibration temperature ± 5 °C | ± 0.8% |
| Absolute accuracy (linear), 0 to 55 °C | ± 1.7% |
| Relative accuracy (log), calibration temperature ± 5 °C | ± 0.08 dB |
| Relative accuracy (log), 0 to 55 °C | ± 0.16 dB |
| Relative accuracy (linear), calibration temperature ± 5 °C | ± 1.6% |
| Relative accuracy (linear), 0 to 55 °C | ± 3.4% |
| Time base accuracy | 0.01% |
| 1 mW Power Reference | |
| Power output | 1.00 mW (0.0 dBm). Factory set to ± 0.5% traceable to the National Physical Laboratories (NPL), UK |
| Accuracy (for two years) | ± 0.5% (23 ± 3 °C); ± 0.6% (25 ± 10 °C); ± 0.9% (0 to 55 °C) |
| Frequency | 50 MHz nominal |
| SWR | 1.06 maximum (1.08 maximum for Option E41xA-003) |
| Connector type | Type N (f), 50 ohms |
| Measurement | |
| Channel functions | A, B, A/B, B/A, A-B, B-A and Relative |
| Storage registers | 10 instrument states can be saved via the Save/Recall menu |
| Predefined setups | For common wireless standards (GSM900, EDGE, NADC, iDEN, Bluetooth, IS-95 CDMA, W-CDMA and cdma2000) |
| Measurement Speed (readings/second) | |
| E-Series E9320 sensors, average only mode (Normal / x2 / Fast) | 20 / 40 / 400 |
| E-Series E9320 sensors, normal mode (Normal / x2 / Fast) | 20 / 40 / 1000 |
| E-Series CW and E9300 average power sensors (Normal / x2 / Fast) | 20 / 40 / 400 |
| 8480 and N8480 Series sensors (Normal / x2 / Fast) | 20 / 40 / NA |
| Trigger | |
| Sources | Internal, External TTL, GPIB, RS232/422 |
| Time resolution | 50 ns |
| Delay range | ± 1.0 s |
| Delay resolution | 50 ns for delays < ± 50 ms; otherwise 200 ns |
| Hold-off range | 1 µs to 400 ms |
| Hold-off resolution | 1% of selected value (minimum of 100 ns) |
| Internal trigger range | –20 to +20 dBm |
| Internal trigger level accuracy | ± 0.5 dB |
| Internal trigger resolution | 0.1 dB |
| Internal trigger latency | 500 ns ± 100 ns |
| External trigger range | High > 2.0 V, Low < 0.8 V; BNC connector; rising or falling edge triggered; input impedance > 1 kΩ |
| Trigger out | TTL compatible levels (high > 2.4 V, low < 0.4 V); BNC connector |
| Sampling Characteristics | |
| Sampling rate | 20 Msamples/second |
| Sampling technique | Continuous sampling |
| Rear Panel Inputs/Outputs | |
| Recorder output(s) | Analog 0 to 1 V, 1 kΩ output impedance, BNC connector. One output (channel A) on E4416A |
| Remote input/output — TTL output | Used to signal when measurement has exceeded a defined limit; High = 4.8 V max, Low = 0.2 V max |
| Remote input/output — TTL input | Initiates zero and calibration cycle; High = 3.5 V min, 5 V max, Low = 1 V max, –0.3 V min |
| Remote I/O connector type | RJ-45 series shielded modular jack assembly |
| RS-232/422 interface | Serial interface; Male plug 9-pin D-subminiature connector |
| Trigger in | Accepts a TTL signal for initiating measurements, BNC connector |
| Trigger out | Outputs a TTL signal for synchronizing with external equipment, BNC connector |
| Ground | Binding post accepts 4 mm plug or bare wire connection |
| Line Power | |
| Input voltage range | 85 to 264 Vac, automatic selection |
| Input frequency range | 47 to 440 Hz |
| Power requirement | Approximately 50 VA (14 Watts) |
Important: E9320 power sensors must be used with an E9288A, E9288B, or E9288C sensor cable.
Important: A compatible power sensor is required to make measurements and is ordered separately — the EPM-P power meter's standard-shipped accessories include only the power sensor cable, power cord and manuals (no sensor). The EPM-P series operates with the E-series E9320 family for peak/average measurements and with the 8480, N8480, E-series CW and E9300 sensors for average power measurements.
Important: The E9288A, B and C sensor cables will also operate with 8480, N8480 and E-series power sensors.
Important: Rise and fall time specifications are only valid when used with the E9288A sensor cable (1.5 meters).
Important: Calibration service options (R-50C-011-3 / R-50C-011-5) are not available in all countries.
Important: To preserve the EMC performance of the product, any cable which becomes worn or damaged must be replaced with the same type and specification.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Keysight
Condition
Factory New
Manufacturer
Keysight Technologies
11730F Keysight Cable New
11730F
11730E Keysight Cable New
11730E
11730D Keysight Cable New
11730D
34131A Keysight Case New
34131A
E9288C Keysight Cable New
E9288C
11730C Keysight Cable New
11730C
11730B Keysight Cable New
11730B
E9288B Keysight Cable New
E9288B
11730A Keysight Cable New
11730A
E9288A Keysight Cable New
E9288A
34161A Keysight Accessory New
34161A
Request A Quote