Skip to product information
1 of 1

AEL-5002-350-18.75 Instek AC DC Electronic Load New

AEL-5002-350-18.75 Instek AC DC Electronic Load New

Request a Quote

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

AEL-5002-350-18.75 Instek AC DC Electronic Load New

Key Features At A Glance

  • Power rating 1875 W continuous, doubling to 3750W (x2) in Turbo mode
  • Rated current 18.75 Arms rms / 56.25Apeak peak (350V voltage class, 50~350Vrms / 500Vdc)
  • Six load modes: CC, Linear CC, CR, CV, CP and AC Rectifier (non-linear) load
  • Frequency range DC,40~440Hz; loading/unloading angle programmable 0–359°
  • Built-in test modes: UPS Efficiency, PV Inverter Efficiency, UPS transfer/back-up time, battery discharge, Fuse/Breaker Trip, Short/OCP/OPP
  • Turbo mode delivers 2× current and power within one second for fuse, breaker and short-circuit testing
  • Up to 8 units in parallel (180kW single-phase) or three-phase △/Y to 540kW under one master
  • Optional GPIB, RS-232, USB and LAN interfaces; isolated voltage and current monitoring
View full details

The GW Instek AEL-5002-350-18.75 is a programmable AC & DC electronic load rated at 1875 W (3750W (x2) in Turbo mode), 18.75 Arms rms, in the 350V voltage class (50~350Vrms / 500Vdc). In summary, it is a single instrument that can sink and characterize the output of AC power sources, DC supplies, inverters, UPS systems, batteries and PV inverters across six load modes — CC, Linear CC, CR, CV, CP and AC Rectifier load.

What is the AEL-5002-350-18.75 used for?

It is used to apply a controlled, repeatable load to a power-producing device so its behavior can be measured. Power-supply engineers use it to verify output regulation; battery and EV labs use its CC and CP modes for discharge and capacity testing; and inverter and UPS developers use its AC rectifier and angle-control functions to confirm that output voltage stays stable through real switching transients.

Why does the AC Rectifier Load mode matter?

The AEL-5002-350-18.75 AC rectifier load mode combines CC and CR loading while holding current THD near 80%, which reproduces the non-linear current that real rectifier-input electronics draw. This is what allows the unit to satisfy IEC 62040-3 (UPS Efficiency Non-Linear) and IEC 61683 (Resistive Plus Non-Linear) for UPS and PV inverter efficiency measurement — tests that a simple resistive load bank cannot perform.

On the measurement side, a 16-bit A/D and DSP core reports Vrms, Arms, Watt, VA, Crest Factor, Power Factor, VTHD, ITHD and harmonic content, plus time measurements for fuse blow time, breaker trip time and UPS transfer time. Over-voltage protection on this model is ≒ 367.5 Vrms / 525Vdc, with over-current at ≒ 19.687 Arms or Programmable and over-power at ≒ 1968.75Wrms or Programmable.

ValueTronics supplies the AEL-5002-350-18.75 as an authorized GW Instek partner, and the equipment is stocked, inspected and functionally verified in our own 20,000 square-foot secure warehouse at our Elgin, Illinois facility rather than drop-shipped sight-unseen. That in-house handling is what lets us stand behind condition and lead time instead of acting as a pass-through broker. The AEL-5000 design aligns with the IEC test framework that compliance and power-electronics labs are expected to meet, which is why it is specified for inverter, UPS and PV efficiency work.

Key selection insights

  • The 350V voltage class sets the maximum DUT voltage this load can sink — 50~350Vrms AC / 500Vdc DC.
  • Turbo mode is the differentiator for protection-device testing: it doubles the rated current to 37.5Arms/56.25Apeak (x2) for up to one second.
  • Constant-resistance range on this unit is 3.2 ohm~64K ohm, defining the impedance window for CR-mode and rectifier-load simulation.
  • For higher power or three-phase work the same model can be paralleled under a single master, so the platform scales without a new instrument family.

Compare Other Models in This Series

The GW Instek AEL-5000 Series is a family of programmable AC & DC electronic loads engineered to sink and characterize the output of power supplies, inverters, UPS systems, batteries, fuel cells, and PV inverters across a single instrument line. Every member of the series shares the same measurement core — a 16-bit A/D and DSP measurement engine reporting Vrms, Arms, Watt, VA, Crest Factor, Power Factor, VTHD, ITHD and harmonic content — and the same complete set of load modes: CC, Linear CC, CR, CV, CP and AC Rectifier Load.

What separates one AEL-5000 model from the next is the working envelope: the maximum voltage class (350V, 425V or 480V), the continuous power rating (from 1875 W to 22500W), and the rated current. Because the firmware, test functions and communication options are common across the series, an engineer can standardize on AEL-5000 operation and simply select the chassis whose envelope matches the device under test.

The AEL-5002-350-18.75 sits in the 350V voltage class at 1875 W continuous (3750W (x2) with Turbo engaged) and 18.75 Arms rms. The comparison set below lets you see exactly where this unit lands relative to its siblings so you can step up or down in capability without leaving the AEL-5000 platform.

Each AEL-5000 model referenced below has its own dedicated new product page with condition-matched pricing, so whether your bench needs the lighter 350V chassis like the AEL-5002-350-18.75 or a higher-power three-phase-capable unit, you can move along the line by output voltage, current and power without changing instrument families or relearning the front panel.

For inverter and UPS verification, the AEL-5002-350-18.75 supports loading and unloading angle control across the full 0–359 degree range, positive or negative half-cycle loading, and SCR/TRIAC current phase-modulation waveforms with 90-degree leading and trailing edges — the behaviors that determine whether an inverter holds its output through real-world switching transients.

Its Turbo mode doubles current and power for up to one second, which is what makes the AEL-5002-350-18.75 suitable for fuse, breaker, short-circuit, OCP and OPP verification where the protective device must see a fault current well above the steady rating before it trips.

Within the AEL-5000 line, the 350V-class units cover the broadest range of power points, the 425V class extends headroom for higher-voltage DC buses up to 600Vdc, and the 480V class targets 700Vdc applications. The higher-power members (11.25kW and above) move to larger floor-standing chassis and can be paralleled — up to 8 units, 180kW single-phase, or combined into three-phase △/Y configurations totaling 540kW under one master.

Model Voltage Range Power (Turbo OFF) Current (rms) Voltage Class
AEL-5002-350-18.75 50~350Vrms / 500Vdc 1875 W 18.75 Arms 350V class
AEL-5004-350-37.5 50~350Vrms / 500Vdc 3750 W 37.5 Arms 350V class
AEL-5008-350-75 50~350Vrms / 500Vdc 7500 W 75.0 Arms 350V class
AEL-5015-350-112.5 50~350Vrms / 500Vdc 15000 W 112.5 Arms 350V class
AEL-5023-350-112.5 50~350Vrms / 500Vdc 22500W 112.5 Arms 350V class
AEL-5003-425-28 50~425Vrms / 600Vdc 2800W 28 Arms 425V class
AEL-5006-425-56 50~425Vrms / 600Vdc 5600 W 56.0 Arms 425V class
AEL-5012-425-112.5 50~425Vrms / 600Vdc 11250W 112.5 Arms 425V class
AEL-5019-425-112.5 50~425Vrms / 600Vdc 18750W 112.5 Arms 425V class
AEL-5003-480-18.75 50~480Vrms / 700Vdc 2800W 18.75 Arms 480V class
AEL-5003-350-28 50~350Vrms / 500Vdc 2800W 28 Arms 350V class
AEL-5006-350-56 50~350Vrms / 500Vdc 5600 W 56.0 Arms 350V class
AEL-5012-350-112.5 50~350Vrms / 500Vdc 11250W 112.5 Arms 350V class
AEL-5019-350-112.5 50~350Vrms / 500Vdc 18750W 112.5 Arms 350V class
AEL-5002-425-18.75 50~425Vrms / 600Vdc 1875 W 18.75 Arms 425V class
AEL-5004-425-37.5 50~425Vrms / 600Vdc 3750 W 37.5 Arms 425V class
AEL-5008-425-75 50~425Vrms / 600Vdc 7500 W 75.0 Arms 425V class
AEL-5015-425-112.5 50~425Vrms / 600Vdc 15000W 112.5 Arms 425V class
AEL-5023-425-112.5 50~425Vrms / 600Vdc 22500W 112.5 Arms 425V class
AEL-5004-480-28 50~480Vrms / 700Vdc 3750 W 28 Arms 480V class

Additional differences in specifications beyond the few shown above are not listed here — see each model’s full specifications below.

Accessories Supplied

The AEL-5000 communication interface is supplied as an optional plug-in card. The orderable interface options for this unit are:

Option Description
PEL-022 GPIB Interface Card
PEL-023 RS-232 Interface Card
PEL-024 LAN Interface Card
PEL-025 USB Interface Card

Product Core & Specifications

The AEL-5002-350-18.75 is a 350V-class AC & DC electronic load. The full published specification set for this model, drawn directly from the GW Instek data sheet, is reproduced below. The unit operates across CC, Linear CC, CR, CV, CP and AC Rectifier Load Mode, with a frequency range of DC,40~440Hz and the complete suite of built-in function-test modes shared by the AEL-5000 family.

Power Rating (Turbo OFF) 1875 W
Power Rating (Turbo ON) 3750W (x2)
Current (rms / peak) 18.75 Arms / 56.25Apeak
Current (Turbo ON) 37.5Arms/56.25Apeak (x2)
Voltage Range 50~350Vrms / 500Vdc
Frequency Range DC,40~440Hz
Operation Mode — CV Range 50~350Vrms / 500Vdc
Constant Resistance Range 3.2 ohm~64K ohm
Over Voltage Protection ≒ 367.5 Vrms / 525Vdc
Over Current Protection ≒ 19.687 Arms or Programmable
Over Power Protection ≒ 1968.75Wrms or Programmable
Over Temperature Protection Yes
Crest Factor Range (CC & CP) √2~5
Power Factor Range (CC & CP) 0~1 Lag or Lead
PV Efficiency Measurement Accuracy (0.5% / Irms) + 1% F.S.
Vmonitor (Isolated) ±500V / ±10V
Imonitor (Isolated) ±56.25Apk / ±10Vpk
Input Impedance Current (mA @ 50/60Hz) ~V*0.3 ; ~V*2.2
External SYNC Input TTL
External Programming Input (Option) F.S / 10Vdc, Resolution 0.1V
Master / Slave (3-phase or Parallel) Yes, 1 master and up to 7 slave units
Operation Temperature 0 ~ 40 °C
Optional Interface GPIB; RS-232; LAN; USB (Optional)
Weight 47.4 lb (21.5 kg)
Dimension (H x W x D) 7.0 x 17.3 x 22.0 in (177 x 440 x 558 mm)
Important Note: Turbo mode on the AEL-5002-350-18.75 raises both current and power to 2× the rated value for up to one second. When sizing this load for fuse, breaker or short-circuit testing, plan around the Turbo figure (37.5Arms/56.25Apeak (x2)), not the continuous rating, so the protective device sees a true fault current.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

AEL-5002-350-18.75

Condition

New

Volts

350 V

Amps

18.7 A

Type

Single

Power

1.875 kW

Manufacturer

Instek