The Agilent 8920A RF Communications Test Set is a full-featured, one-box test set designed to meet the service and repair needs of the RF wireless communications market. The instrument consolidates the functions of more than 20 complete instruments into a single portable, lightweight chassis, providing transmitter and receiver testing capability through a single-keystroke interface.
The 8920A is applied to RF radio service and repair, cellular phone test, and trunked radio test. For cellular phone applications, the call processing interface emulates a base station and automatically establishes and maintains a cellular link with an analog cellular phone. The signaling capability supports tone sequential, digital paging formats including CCITT, POCSAG, and ZVEI, DTMF, trunking, and cellular signaling, making the unit applicable to LTR, EDACS, MPT 1327, AMPS/EAMPS/NAMPS, TACS/ETACS, NMT 450/900, and JTACS/NTACS radio test when configured with the appropriate options.
Hewlett-Packard's test and measurement division was spun out as Agilent Technologies in 1999, and Agilent's electronic measurement business was subsequently separated as Keysight Technologies in 2014. The 8920A was originally introduced under Hewlett-Packard branding and continued under Agilent, which is reflected in the cover-page tagline 'Innovating the HP Way' that appears on this datasheet.
| Category | Specification | Value |
|---|---|---|
| Signal Generator RF Frequency | Frequency Range (Standard) | 30 MHz to 1 GHz |
| Frequency Range (Option 055) | 250 kHz to 1 GHz | |
| Reference Oscillator (TCXO Standard) | Type | TCXO |
| Temperature | 1 ppm (0 to +55 °C) | |
| Aging | <2 ppm/year | |
| Warm-Up Time | <30 sec. to be ±2 ppm of final frequency | |
| Signal Generator Output (RF IN/OUT, Standard) | Level Accuracy | ±1.8 dB (level ≥–127 dBm) |
| Level Range | –137 to –20.5 dBm into 50 Ω | |
| Reverse Power | 60 W continuous, 100 W for 10 sec/min | |
| DUPLEX OUT Connector (Standard) | Level Accuracy | ±1.5 dB |
| Level Range | –127 to +5 dBm into 50 Ω | |
| Reverse Power | 200 mW max | |
| Spectral Purity | Harmonics | <–30 dBc |
| Non-Harmonic Spurious | <–60 dBc (at >5 kHz from carrier) | |
| SWR (RF In/Out / Duplex Out) | <1.5:1 / <2.0:1 (level <–4 dBm) | |
| FM Modulation | FM Rate (Internal) | DC to 25 kHz (1 dB BW) |
| FM Accuracy (1 kHz rate, ≤10 kHz dev) | ±7.5% of setting ±50 Hz | |
| FM Distortion | <1% at >4 kHz deviation, 1 kHz rate | |
| Center Frequency Accuracy (DC FM) | ±500 Hz | |
| AM Modulation (Standard) | Frequency Range | 30 MHz to 1 GHz |
| AM Depth | 0 to 90% (usable to 99%) | |
| AM Rate | 20 Hz to 25 kHz (3 dB BW) | |
| AM Distortion | <2% at 1 kHz rate, <30% AM | |
| Audio Source | Frequency Range | DC to 25 kHz |
| Frequency Accuracy | 0.025% of setting | |
| Output Level Range | 0.1 mV to 4 Vrms | |
| Output Impedance | <1 Ω (1 kHz) | |
| RF Analyzer — Frequency Measurement | Measurement Range (Standard) | 30 MHz to 1 GHz |
| Measurement Range (Option 055) | 400 kHz to 1 GHz | |
| Accuracy | ±1 Hz plus timebase accuracy | |
| RF Power Measurement (Standard) | Range | 1 mW to 60 W continuous, 100 W for 10 sec/min |
| Accuracy | ±10% of reading ±1 mW | |
| SWR | <1.5:1 | |
| FM Measurement | Frequency Range (Standard) | 10 MHz to 1 GHz |
| Deviation | 20 Hz to 75 kHz | |
| Accuracy | ±4% of reading plus residual FM and noise | |
| Bandwidth (3 dB) | 2 Hz to 70 kHz | |
| AM Measurement | Frequency Range | 10 MHz to 1 GHz (usable to 400 kHz) |
| Depth | 0 to 95% | |
| Accuracy | ±5% of reading ±1.5% AM | |
| AF Analyzer — Frequency Measurement | Range | 20 Hz to 400 kHz |
| Accuracy | ±0.02% plus resolution plus timebase accuracy | |
| External Input | 20 mV to 30 Vrms | |
| AC Voltage Measurement | Range | 0 to 30 Vrms |
| Accuracy | ±3% of reading (20 Hz to 15 kHz, inputs >1 mV) | |
| Residual Noise | 150 µV (15 kHz bandwidth) | |
| DC Voltage Measurement | Range | 100 mV to 42 V |
| Accuracy | ±1% of reading plus DC offset | |
| DC Offset | ±45 mV | |
| Oscilloscope | Frequency Range | 2 Hz to 50 kHz (3 dB BW) |
| Scale/Division | 10 mV to 10 V | |
| Amplitude Accuracy | ±1.5% of reading ±0.1 division (20 Hz to 10 kHz) | |
| Time/Division | 1 µsec to 200 msec | |
| Digital Interface (RS-232) | Ports | 2-way RS-232 |
| Connector | RJ-11 (6 pins, 2 addressable serial ports, rear panel) | |
| Baud Rates | 300/600/1200/2400/4800/9600/19200 | |
| Reference In Port | Connector | BNC female (rear panel) |
| Input Frequency | 1/2/5/10 MHz | |
| Input Level Range | >0.15 Vrms | |
| Reference Out Port | Connector | BNC female (rear panel) |
| Output Frequency | 10 MHz | |
| Output Level | >0.5 Vrms | |
| User Memory | Standard RAM | Approximately 1 Mbyte for nonvolatile save/recall (>1000 sets) |
| General | Dimensions (H × W × D) | 7.5 × 13 × 19 in (188 × 330 × 456 mm) |
| Weight (fully optioned) | 37 lbs (16.8 kg) | |
| Power (AC) | 100 V to 240 V, 48 to 440 Hz, nominally 80 watts | |
| Power (DC) | 11 to 28 V, nominally 120 watts | |
| CRT Size | 7 × 10 cm | |
| Operating Temperature | 0 to +55 °C | |
| Storage Temperature | Range | –55 to +75 °C |
| Calibration Interval | Recommended | Two years |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Agilent
Condition
Used
Manufacturer
Agilent
3
GPIB/RS-232 Interface
4
Tone/Digital Signalling
5
512k RAM (Memory)
10
400 Hz High Pass Filter
102
Spectrum Analyzer with Tracking Generator and ACP (adjacent channel power)