Skip to product information
1 of 1
Used
lab tested

8903B Agilent Audio Analyzer Used

8903B Agilent Audio Analyzer Used

Shipping calculated at checkout.
Calibrations
check availability
Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Additional Features:

  • Measures distortion, SINAD, signal-to-noise
  • Measures true-RMS AC volts, DC volts, frequency
  • Low-distortion programmable source
  • RMS, average, and quasi-peak detection
  • 50/600 Ohm Input resistance
  • Balance Input
  • Plug In Filters
  • Sweep capability
Share on
View full details

The Agilent HP 8903B combines the functionality of a low-distortion audio source, high-performance distortion analyzer, frequency counter, AC voltmeter, DC voltmeter, and SINAD meter into one compact package. With microprocessor control of source and analyzer, it can perform stimulus-response measurements (such as signal-to-noise ratio and swept distortion) automatically with no additional equipment.

For accurate measurement of complex waveforms and noise, the analyzers use true-rms detection. Average (rms calibrated) and quasi-peak detection are also available via front panel control. Accurate distortion measurements can typically be made down to less than –90 dB (0.003%) between 20 Hz and 20 kHz. Over the same frequency range, flatness measurements are possible to 0.05 dB (0.5%). The analyzers precision reciprocal counter gives you fast, accurate characterizations of audio frequencies. For example, when counting a 1 kHz signal, the analyzers will be accurate within ±0.14 Hz.

For ease of use, most measurements are made with one or two keystrokes. The 8903B automatically tunes and autoranges for maximum accuracy and resolution. For quick identification of input signals, the analyzers count and display the input frequency in all ac measurement modes. The 8903B can also measure distortion of one signal while generating another frequency, because analyzer tuning and source frequency are independent.

Model No

8903B

Condition

Used

Manufacturer

Agilent

Frequency

100 kHz

["1

Input/Output Connectors on Rear Panel Only

10

400 Hz High-Pass Filter (Left Slot)

11

CCITT Weighting Filter (Left Slot)

12

CCIR Weighting Filter (Left Slot)

13

C-Message Weighting Filter (Left Slot)

14

CCIR/ARM Weighting Filter (Left Slot)

15

“A’’ Weighting Filter (Left Slot)

50

Right 400 Hz high pass filter

51

CCITT Weighting Filter (Right Slot)

52

CCIR Weighting Filter (Right Slot)

53

Right C-Message weighting filter

54

Right CCIR/Arm weighting filter

55

Right "A" weighting filter

907

Front Handle Kit

908

Rack Flange Kit

909

Rack Flange Kit with 4 Front Handles"]