Skip to content

The Aim-TTi TG2000 and its companion TG1000 are Direct Digital Synthesis (DDS) function generators that bring crystal-referenced precision to a value-oriented price point. Every waveform is derived digitally from a crystal master clock using a phase accumulator, a look-up table and a DAC, so the accuracy and stability of the output track that of the reference oscillator. Unlike generators that digitise only the frequency setting, every function is digitally controlled, allowing complete instrument set-ups to be stored and — on the TG2000 — full remote control to be implemented.
A function generator supplies the known, controllable stimulus an engineer needs to exercise a circuit and observe its response. Across these units that stimulus can be swept in frequency, gated, amplitude-modulated, frequency-shift-keyed or stepped through a tone list, while the multi-function auxiliary output can deliver a sweep-start pulse and an adjustable marker for synchronising an oscilloscope or chart recorder. Because all parameters are controlled electronically and up to nine complete set-ups are held in non-volatile memory, automated test sequences are straightforward to configure.
ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, and has specialised in new and used test-and-measurement equipment since 1992.
Thurlby Thandar Instruments Ltd., known as TTi, is one of Europe's established manufacturers of test-and-measurement instruments. Its products have historically been sold under two brand names, TTi and Aim, and the company has been consolidating its full product range under a single Aim-TTi brand, with many products continuing to carry the earlier TTi or Aim marks during the transition.
The TG1000 and TG2000 form a two-model family of DDS function generators that share the same architecture, waveform set, modulation modes and front-panel operation, differing principally in maximum output frequency. Both derive every waveform from a crystal clock using direct digital synthesis and store up to nine complete set-ups in non-volatile memory.
The TG2000 extends the upper frequency limit to 20MHz and adds RS-232 and USB remote interfaces, while the TG1000 covers the same functions to a 10MHz limit. Choosing between them is largely a question of the highest frequency required and whether programmable remote control is needed.
Each model below links to its own dedicated product page with new-matched pricing. Select the model that fits your frequency and interface requirements, then choose the new listing that matches your condition and budget preference.
The TG2000 is the model equipped for remote operation: it includes an RS-232 interface — operable in a conventional mode or an addressable mode that controls up to 32 instruments from one port — together with a USB 1.1 connection, enabling full programmable control of every function and remote storage of set-ups. It also carries the family's 20MHz upper frequency limit.
As the comparison table shows, the core difference is frequency span: the TG1000 reaches 10MHz and the TG2000 reaches 20MHz, each with six-digit or 1mHz resolution and the same ±10ppm one-year accuracy. Waveforms, amplitude range, sweep, gating, AM, FSK and tone-switching modulation are common to both.
The second difference is connectivity. The TG2000 provides RS-232 and USB interfaces for full remote control and set-up storage, whereas the TG1000 is operated from its front panel. All other specifications — output impedance options, DC offset, the auxiliary sync output, the display and the stored-settings memory — are shared across the family.
| Model | Max Frequency | Resolution | Output Level |
|---|---|---|---|
| TG1000 | 10 MHz | 6 digits or 1mHz | 5mV to 20V pk-pk |
| TG2000 | 20 MHz | 6 digits or 1mHz | 5mV to 20V pk-pk |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Frequency | |
| Frequency Range | 1mHz to 10MHz (TG1000) or 20MHz (TG2000) |
| Resolution | 6 digits or 1mHz |
| Accuracy | ±10ppm for 1 year, 18°C to 28°C; ±1mHz below 0.2Hz |
| Tempco. | Typically <1ppm/°C outside of 18°C to 28°C |
| Waveforms — Sinewave | |
| Range | 1mHz to 10MHz/20MHz |
| Resolution | 6 digits or 1mHz |
| Distortion | <0.3% THD to 20kHz (typically 0.1%), <-45dBc to 300kHz, <-35dBc to 20MHz (typically <-40dBc) |
| Spurii | Non harmonically related spurii <-55dBc to 1MHz, <(-55dBc + 6dB/octave) 1MHz to 20MHz |
| Output Level | 5mV to 20V pk-pk from 50 Ω or 600 Ω |
| Waveforms — Squarewave | |
| Range | 1mHz to 10MHz/20MHz |
| Resolution | 6 digits or 1mHz |
| Symmetry | variable 20% to 80% in 1% steps |
| Aberrations | <5% + 2mV |
| Rise & Fall Times | <22ns |
| Output Level | 5mV to 20V pk-pk from 50 Ω or 600 Ω |
| Waveforms — Triangle | |
| Range | 1mHz to 1MHz |
| Resolution | 6 digits or 1mHz |
| Linearity error | <0.5% to 100kHz |
| Output Level | 5mV to 20V pk-pk from 50 Ω or 600 Ω |
| Waveforms — Positive and Negative Pulse | |
| Range | 1mHz to 10MHz/20MHz |
| Resolution | 6 digits or 1mHz |
| Symmetry | variable 20% to 80% in 1% steps |
| Aberrations | <5% + 2mV |
| Rise & Fall Times | <22ns |
| Output Level | 2.5mV to 10V pk-pk from 50/600 positive or negative only pulses with respect to the DC Offset baseline |
| Modulation Modes — Gated | |
| Carrier frequency | From 0.1Hz to 10MHz/20MHz |
| Carrier waveforms | All |
| Trigger rep. rate | dc to 100kHz external, dc to 5kHz internal |
| Gate source | Front panel MAN TRIG key, Internal Gate Generator, TRIG/GATE input, or Remote Interface |
| Modulation Modes — Sweep | |
| Carrier waveforms | All |
| Sweep Mode | Linear or logarithmic, single or continuous |
| Sweep Width | 0.2Hz to 10MHz/20MHz in one range. Phase continuous. Independent setting of the start and stop frequency |
| Sweep Time | 50ms to 999s (3 digit resolution) |
| Markers | Available from AUX output. Variable during sweep |
| Sweep Trigger source | The sweep may be free run or triggered from: front panel MAN TRIG key, TRIG/GATE input, or Remote Interface |
| Modulation Modes — Amplitude Modulation | |
| Carrier frequency | 1mHz to 10MHz/20MHz |
| Carrier waveforms | All |
| Modulation source | VCA IN socket |
| Modulation Modes — Frequency Shift Keying (FSK) | |
| Carrier frequency | 1Hz to 10MHz/20MHz |
| Carrier waveforms | All |
| Switch rate | dc to 5kHz (internal), dc to 1MHz (external) |
| Switching signal source | Front panel MAN TRIG key, Internal Trigger Generator, TRIG/GATE input, or Remote Interface |
| Modulation Modes — Tone | |
| Carrier waveforms | All |
| Frequency list | Up to 16 frequencies between 1Hz and 10MHz/20MHz |
| Min. switching time | 1ms per tone |
| Switching source | Front panel MAN TRIG key, Internal Trigger Generator, TRIG/GATE input, or Remote Interface |
| Internal Trigger/Gate Generator | |
| Period | 0.2ms to 999s (resolution 0.2 ms) |
| Waveform | Square wave (1:1 duty cycle) |
| Main Output | |
| Output Impedance | 50 Ω or 600 Ω switchable |
| Amplitude | 5mV to 20V pk-pk open circuit (2.5mV to 10V into 50/600) |
| Accuracy | ±3% ±1mV at 1kHz into 50/600 |
| Flatness | ±0.2dB to 500kHz; ±1dB to 10MHz; ±2dB to 20MHz |
| DC Offset | ±10V from 50/600. DC offset plus signal peak limited to ±10V. Accuracy ±3% ±10mV |
| Resolution | 3 digits for both amplitude and offset |
| Auxiliary Output | |
| Waveform Sync | Outputs a 50% duty cycle squarewave at the main waveform frequency |
| Trigger Out | Outputs a replica of the current trigger signal |
| Sweep Sync | Outputs a trigger signal at the start of sweep (for synchronising an oscilloscope or chart recorder). Can additionally output a sweep marker. |
| Signal Levels | Output Impedance 50 Ω nominal. Logic levels of <0.8V and >3V. Sweep Sync is a 3 level waveform, low at start of sweep, high at end of sweep, with a narrow 1V pulse at the marker point |
| Inputs — Ext Trig/Gate | |
| Frequency Range | DC to 1MHz for FSK; DC to 100kHz for Gate; DC to 2.5kHz for Tone and Sweep |
| Signal Range | Nominal TTL level threshold; maximum input ±10V |
| Min. Pulse Width | 100ns for Gate/FSK; 0.2ms for Sweep and Tone |
| Input Impedance | Typically 10kΩ |
| Inputs — VCA In | |
| Frequency Range | DC - 100kHz |
| Signal Range | 2.5V for 100% level change at maximum output |
| Input Impedance | Typically 6kΩ |
| Interfaces (TG2000 only) | |
| RS232 | Variable Baud rate (19200 max), 9-pin D-connector. As well as operating in a conventional RS-232 mode the interface can be operated in addressable mode whereby up to 32 instruments can be addressed from one RS-232 port |
| USB | Standard USB hardware connection. Conforming USB 1.1 |
Important: In positive or negative pulse modes the amplitude range is 2.5mV to 10V pk-pk open circuit.
Important: Specifications apply at 18° - 28°C after 1 hour warm-up, at maximum output into 50 Ω.
Important: RS-232 and USB remote-control interfaces are fitted to the TG2000 only; the TG1000 has no digital interface.
Important: Mains operating voltage (100V / 110-120V / 220-240V) is selected by an internal adjustment, not a front-panel switch.
This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
TTi
Condition
Factory New
Manufacturer
TTi
Func_gen_freq
10 MHz
Request A Quote