Keysight E4361A Solar Array Simulator DC Module, 65 V / 8.5 A / 510 W (Pre-Owned)

Keysight E4361A Solar Array Simulator DC Module, 65 V / 8.5 A / 510 W (Pre-Owned)

🎓 Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Keysight E4361A Solar Array Simulator DC Module, 65 V / 8.5 A / 510 W (Pre-Owned)

Key Features At A Glance

  • Programmable DC source that simulates the I-V curve of a solar array as a low-output-capacitance current source
  • Up to 2 outputs and up to 1200 W total in a small 2U-high, 19-inch mainframe
  • Three operating modes: Simulator (SAS), Table, and Fixed
  • Fast I-V curve generation within 30 ms (256-point) or 350 ms (4,096-point) per resolution setting
  • LIST mode pre-programs up to 512 I-V curves with dwell times from 30 ms to 33,554 s
  • LAN (10/100), USB 2.0, and GPIB interfaces standard; fully compliant to LXI Class C
  • Built-in voltage and current measurement with data logging at 10 readings/s
  • Over-voltage, over-current, and over-temperature protection
View full details

The Keysight E4360A Modular Solar Array Simulator is a dual-output programmable DC power source that simulates the output characteristics of a solar array. It is primarily a current source with very low output capacitance, capable of quickly reproducing the I-V curve of different arrays under different conditions such as temperature and age. A single 2U-high mainframe provides up to 2 outputs and up to 1200 W, and the platform is available either as an off-the-shelf instrument or integrated into a full turn-key solar array simulator system.

Solar array simulators are used in satellite test applications, where solar panels with unique I-V characteristics power the satellite and a specialized supply is needed to verify the satellite power system and the design of the power bus regulator on the ground. They are also used in residential photovoltaic test applications: a solar array simulator verifies that a microinverter tracks the maximum power point under varying environmental conditions such as sunny, cloudy, shadowing, and different temperatures, and confirms that the microinverter is reliable and efficient.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house by our technicians before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

The instrument's manufacturer traces its corporate lineage from Hewlett-Packard to Agilent Technologies, which was spun out in 1999, and then to Keysight Technologies in 2014. The brand has been evolving since 1939.

Compare Other Models in This Series

The E4360 is a modular platform built around the E4360A mainframe, which holds up to two solar array simulator modules in 2U of rack space and delivers up to 1200 W total. Buyers can order the mainframe and modules separately for self-assembly, or order a preconfigured, fully assembled mainframe shipped as a tested instrument.

Two simulator DC modules are offered: the E4361A and the E4362A, along with J-option variants of those modules. Preconfigured units pair an E4360A mainframe with two like modules, with the E4367A using two E4361A modules and the E4368A using two E4362A modules.

Each model linked below is its own dedicated product page with pre-owned condition-matched pricing. Select the configuration that matches your required output ratings and ordering options.

The modules differ in their output ratings as shown in the comparison table. The E4361A module is rated 65 V, 8.5 A, 510 W, while the E4362A module is rated 130 V, 5 A, 600 W; J-option variants such as the E4362A-J01 through -J05 and E4361A-J01 carry their own voltage, current, and power ratings. Across all modules the recommended calibration interval is 1 year and output terminal isolation is ±240 Vdc from chassis ground.

Preconfigured mainframes consolidate the choice: the E4367A is an E4360A mainframe with two E4361A modules and the E4368A is an E4360A mainframe with two E4362A modules, while the E4366A ships with two special-option modules. Refer to the comparison table for the per-model output power, voltage, and current ratings that distinguish each configuration.

Model Max Power Max Voltage (Voc) Max Current (Isc)
E4361A 510 W 65 V 8.5 A
E4360A 1200 W
E4362A 600 W 130 V 5 A
E4367A 65 V 8.5 A

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
Output Ratings (Simulator and Table Mode)
Maximum power 510 W
Maximum open circuit voltage (Voc) 65 V
Maximum voltage point (Vmp) 60 V
Maximum short circuit current (Isc) — line voltage 200/230/240 V 8.5 A
Maximum current point (Imp) — line voltage 200/230/240 V 8.5 A
Maximum short circuit current (Isc) — line voltage 100/120 V 4.25 A
Maximum current point (Imp) — line voltage 100/120 V 4.25 A
Output Ratings (Fixed Mode)
Minimum impedance (∆V/∆Vl) 0.25 Ω
Voltage 0 - 60 V
Current — line voltage 200/230/240 V 0 - 8.5 A
Current — line voltage 100/120 V 0 - 4.25 A
Current derating factor (from 40 to 55 °C) 0.11 A/°C
Output Voltage Ripple & Noise (20 Hz to 20 MHz)
Simulator/table mode 20 mVrms / 125 mVp-p
Fixed mode (constant voltage) 24 mVrms / 150 mVp-p
Programming Accuracy (@ 23 ±5 °C)
Fixed mode voltage 0.075% + 25 mV
Fixed mode current 0.2% + 20 mA
Readback Accuracy (@ 23 ±5 °C)
Voltage 0.08% + 25 mV
+Current 0.20% + 20 mA
−Current 0.35% + 48 mA
Load Regulation – Fixed Mode
Constant voltage 2 mV
Constant current 1 mA
Line Regulation – Fixed Mode
Constant voltage 2 mV
Constant current 1 mA
Output Current Ripple & Noise (20 Hz to 20 MHz)
Simulator/table mode 4 mArms / 32 mAp-p
Fixed mode (constant current) 2.5 mArms / 19 mAp-p
Output Programming Range (maximum programmable values)
Simulator/table mode voltage 0 - 65 V
Fixed mode voltage 0 - 61.5 V
Current — line voltage 200/230/240 V 0 - 8.66 A
Current — line voltage 100/120 V 0 - 4.33 A
Overvoltage protection 0 - 74 V
Overcurrent limit 0 - 10.6 A
Programming Resolution (average values)
Voltage 19 mV
Current 2.7 mA
Overvoltage protection 325 mV
Overcurrent limit 46 mA
Programming Accuracy
Overvoltage protection 0.65 V
Overcurrent limit 0.5% + 215 mA
Current monitor (referenced to P common) 1.0% + 130 mA
Fixed Mode Analog Current Programming
Analog programming 1.0% + 5.5 mA
+Ip to −Ip differential input (0 to full scale) 0 to -4 V
Max. common mode voltage (referenced to +OUT) ±18 V
Nominal input impedance 20 kΩ
Drift/Temperature Stability
Voltage 0.04% + 1 mV
Current 0.1% + 0.85 mA
Temperature Coefficients (output change per °C)
Voltage 0.01% + 325 μV
Current 0.025% + 215 μA
Other Supplemental Characteristics
Output capacitance < 100 nF
Maximum reverse diode current (with fans running) 8.5 A
Output current settling time < 5 μs
Maximum capacitive load (simulator/table & fixed mode) 2000 μF
Load lead drop with remote sensing (simulator/table mode) Up to 2 volts + (Voc - Vmp)
Load lead drop with remote sensing (fixed mode) Up to 2 volts total
Current sinking capability (simulator/table mode) 500 mA
Current sinking capability (fixed mode) 440 mA
Voltage programming rise/fall time < 8 ms
Voltage programming settling time 25 ms typical
Auto-parallel configuration Up to 4 outputs
Series and shunt switching frequency 50 kHz maximum
Output terminal isolation (from chassis ground) ±240 Vdc
Recommended calibration interval 1 year
Important: Maximum output power is limited to 600 W at 100/120 Vac; full 1200 W output requires Option 904 and operation at 220/240 Vac.
Important: When configuring a mainframe with fewer than 2 filled module slots, you MUST order a Filler Panel Kit (Option FLR or E4369A) to fill any empty module slot for proper operation; each kit contains one filler panel.
Important: For rack mounting, you MUST order the Rack Mount Kit (Option 908); standard rack mount hardware will not work.
Important: The mainframe has side air vents; 1U of space is required between the instruments to retain proper cooling.
Important: The unit may go out of specification when subjected to RF fields of 3 volts/meter in the frequency range of 26 MHz to 1 GHz.
Important: Electrostatic discharges greater than 1 kV near the I/O connectors may cause the unit to reset and require operator intervention.
Important: A power cord (line cord) option must be selected and ordered separately; it is not included by default with the mainframe.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Pre-Owned

Manufacturer

Keysight

Dcsup_amps

8.5 A

Dcsup_volts

65 V

Dcsup_watts

510 W