Key Features At A Glance

  • Up to 8 channels of isolated inputs via interchangeable plug-in modules, each with its own A/D converter
  • 10 MS/s, 10-bit sampling with the high-speed module; 100 kS/s, 16-bit sampling with the high-resolution module
  • 10.4-inch color TFT display, 640 × 480 resolution, with multiple divided and zoom display formats
  • Standard 400 k word record length, expandable to 16 M words via /M1, /M2, or /M3 memory options
  • GP-IB, RS-232-C, and Centronics interfaces standard for remote control, data transfer, and printing
  • Built-in thermal printer (up to 20 mm/s) plus optional SCSI and 1.2 GB internal hard disk for recording
  • Plug-in modules for high-speed, high-resolution, thermocouple temperature, and logic measurement
  • Compact and light at approximately 6.8 kg including the 8-channel high-speed isolation module
View full details

The DL708 is a multi-channel digital scope built to measure isolated physical signals across as many as eight channels. It combines conventional oscilloscope-style waveform capture — where the time axis, voltage axis, and trigger can be set while observing a waveform — with data-acquisition and recording technology, so one instrument can measure signals ranging from slowly changing temperature to high-speed signals in the MHz region. Interchangeable plug-in modules give the DL708 flexibility for a variety of applications.

Yokogawa positions the DL708 for a broad set of physical-measurement tasks. Listed applications include maintenance and inspection of turbines and rotating machinery, measuring the behavior of engines, monitoring large plants, and monitoring the operation of press machines. It is also suited to observing impact and vibration tests, capturing sporadic one-shot events, recording changes in temperature and electric potential, and maintaining substations.

ValueTronics keeps the DL708 and its plug-in modules in our own 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where we stock and hold inventory directly. Every pre-owned order is fulfilled from that facility: pre-owned units are inspected and functionally verified in-house before they ship, while new units leave the warehouse factory-sealed exactly as received.

Compare Other Models in This Series

The DL708 is built around a modular, eight-slot architecture: each input channel is supplied by a plug-in module that contains its own A/D converter, and different module types can be used together in the same mainframe. This lets a single DL708 be configured for tasks as varied as high-speed voltage capture, high-resolution measurement, thermocouple temperature acquisition, and logic recording.

Because the plug-in modules and the memory expansions are ordered separately from the mainframe, the way a given DL708 is equipped determines its measurement capability. The plug-in modules and the /M1, /M2, and /M3 memory options are the main points of configuration covered below.

Each pre-owned configuration listed here is its own dedicated product page with condition-matched pricing. Select the mainframe and module combination that fits your measurement needs, and the corresponding pre-owned page will reflect availability and pricing for that exact item.

The plug-in modules differ primarily in resolution, bandwidth, sampling rate, and input voltage handling. The high-speed module (701851) is non-isolated and provides 10-bit resolution at up to 10 MS/s with a DC-to-5 MHz band, while the high-speed isolation module (701850) offers isolated inputs at 10 bits and 10 MS/s with a DC-to-2 MHz band. The high-resolution isolation modules step up to 16-bit resolution at 100 kS/s for lower-frequency, higher-precision work.

Maximum input voltage also varies by module: the high-resolution isolation module (701853) is rated 100 V (DC + AC peak) between signal H and L, while the high-resolution high-voltage isolation module (701852) is rated 850 V (DC + AC peak). The temperature module (701860) accepts thermocouple inputs with a 42 V (DC + AC peak) limit. The comparison table that follows lists each module's resolution, sampling rate, bandwidth, and input ratings side by side.

Model A/D Resolution Max Sampling Rate Max Input Voltage
DL708 10 MS/s (max)
701850 10 bits (max 14 bits) 10 MS/s 850 V (DC + AC peak) with 700929 probe; 250 V main unit only
701851 10 bits (max 14 bits) 10 MS/s 250 V (DC + AC peak)
701852 16 bits 100 kS/s 850 V (DC + AC peak)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Power cable (1)
  • Set of instruction manuals (1)
  • Front panel protection cover (B9946EA, opaque type) (1)
  • Printer roll paper (1)
  • Cover panel (8)
  • Soft case for probes & leads (1)
  • Printer connecting cable (B9946YY) (1)

Product Core & Specifications

Specification Value
Input
Form Plug-in input units (each unit contains an A/D converter)
Number of slots 8 (different kinds of units can be used together)
Horizontal
Max. record length 400 k words (100 k words/ch model, standard); 4 M words (1 M word/ch, /M1); 8 M words (2 M word/ch, /M2); 16 M words (4 M word/ch, /M3)
Time axis accuracy ±0.005%
Sweep time (100k words/ch model) 500 ns/div to 50000 s/div (1-2-5 steps)
Sweep time (other models) 500 ns/div to 100000 s/div (1-2-5 steps)
Acquisition Mode
Envelope Holds the peak value at the max. sampling rate, independent of time/div
Box average Resolution of the A/D converter increased by max. 4 bits
History memory Holds up to 1000 screens of past waveforms
Sequential store Specify between 2 and 1000 storage operations
Roll Sampling rate of 100 kS/s can be used
Trigger
Mode AUTO / AUTO-LEVEL / NORMAL
Pretrigger 0 to 100% (1% steps)
Source INT (1ch to 8ch) / EXT / LINE
Slope Rise / Fall / Both
Type Edge trigger; Event/Pattern (A→B(n), A Delay B, Edge on A); Pulse width (B>Time, B
Screen Update Rate
1 channel used Max. 30 screens per sec
8 channels used Max. 20 screens per sec
Display
Display 10.4-inch TFT color liquid crystal display
Size 211.2 (horizontal) × 158.4 mm (vertical)
Total number of pixels 640 × 480
Number of waveform display pixels 501 × 432
Display format Divided: Single/Dual/Quad/Hexa/Octal; Zoom (Main/Z1/Z2 combinations); X-Y: TY/XY/TY & XY
Accumulation display PERSIST (one color); COLOR (infinite accumulation in eight colors with data frequency information)
Max. number of display traces 24 traces (in zoom mode: 8 captured + 16 enlarged traces)
Built-in Printer (Recorder)
Printing system Thermal line dot method
Dot density 8 dots/mm
Paper width 112 mm
Effective recording width 104 mm
Recording speed Max. 20 mm/s
Real-time recording Can be used at a time axis slower than 500 ms/div
Real-time Hard Disk Recording (requires optional 1.2 GB HDD)
Capacity at one time Max. 128 M word (256 MB)
Time axis 1 s/div or less
Max. sampling rate 10 kS/s or less (8 channel use); 100 kS/s or less (1 channel use)
Restriction Cannot be used in combination with real-time printing, average or sequential storage
Inter-channel Computation
Applicable data Max. 100 k words (MATH1 only); max. 50 k words (MATH1 & MATH2 simultaneous)
Standard operations Addition, subtraction, multiplication, FFT (power spectrum) and phase-shift
Standard FFT Type PS; points 1000, 2000, 10000 (MATH1 only); windows rectangular, hanning; starting point specification possible
User Define computation (optional) Addition, subtraction, multiplication, division, ABS, SQRT, LOG, EXP, trigonometric, moving average, differential, integral; FFT types PS, LS, RS, PSD, CS, CH
Cursor / Waveform Measurement
Cursor type Marker (two markers); two horizontal axis cursors; two vertical axis cursors; H & V
Automatic measurement max items 8
Measurement items P-P, Max, Min, High, Low, Avg, Rms, +Ovr, -Ovr, Rise, Fall, Freq, Period, +duty, -duty, +Width, -Width, Amp, StdDev, Integ1, Integ2, F delay, R delay
External I/O
Trig-IN/Trig-OUT RCA pin jack; input voltage CMOS level
VGA video signal output D-Sub 15-pin; VGA compatible
GP-IB interface IEEE St'd 488-1978; SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT0, C0; protocol IEEE St'd 488.2 1987
RS-232-C interface D-Sub 9-pin; EIA RS-232-C; 1200, 2400, 4800, 9600, 19200 bps
Centronics interface Half pitch 36-pin connector (ESC-P, BJ, LIPS, PR201, PCL5)
SCSI interface (optional) ANSI X3.131-1986; half pitch 50-pin (pin type); unbalanced (single end)
External Media
Internal floppy disk drive 1 drive, 3.5"; 640, 720 KB / 1.2, 1.44 MB (MS-DOS format)
1.2 GB internal hard disk (optional) 1 drive, 3.5"; 1.2 GB (SCSI type)
General Specifications
Reference operating conditions Ambient temperature 23±5°C; humidity 55±10% RH
Storage temperature -20 to 60°C
Important: The high-resolution high-voltage isolation module (701852) and the logic input module (701870) require DL708 firmware version 2.00 or later.
Important: The DL708 main unit does not include plug-in modules; input modules (701850, 701851, 701852, 701853, 701860, 701870) must be ordered separately to acquire signals.
Important: Plug-in modules do not include any probes. To make a measurement, the appropriate probe must be ordered separately (e.g., 700929 for 701850, 700998 for 701851, 700986/700987 for 701870).
Important: The 700987 Isolation Logic Probe does not include any measurement lead. To measure a signal, 366961 (42 V or less) or a combination of 758917 and either 758922 or 758929 is required.
Important: The 701852 and 701870 modules require DL708 firmware version 2.00 or later; contact your local YOKOGAWA sales office to upgrade the firmware.
Important: Memory expansion options /M1, /M2 and /M3 are mutually exclusive — select only one.
Important: Specifying /C8 (1.2 GB internal HDD) also adds an SCSI interface, so /C7 and /C8 cannot be specified at the same time.
Important: Real-time hard disk recording requires the optional 1.2 GB internal hard disk and cannot be used in combination with real-time printing, average, or sequential storage.
Important: The 10.4-inch TFT color LCD may include defects of about 0.02% of all pixels.
Important: Conversion adapters 366921/366923 and BNC cable leads for the high-speed modules are not isolated and should be used only for measurement under 42 V.
Recommended pairing: the 701870 logic input module accepts the 700986 high-speed or 700987 isolation logic probes, purchased separately per the module's compatibility list.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Yokogawa

Condition

Pre-Owned

Manufacturer

Yokogawa

Osc_ch

8

Osc_sampl

10 MS/s

(1X) 701855

High-Speed Isolation Module (HS_ISOL)

(7X) 701850

The High-Speed Isolation Module

1

100-120 VAC

C8

Internal hard disk + SCSI Interface*2

D

UL/CSA standard power cord (A1006WD) Maximum rated voltage: 125 V , maximum rated current: 7 A

M2

Memory extension to 2MW/CH*1