The Agilent E1412A is a 6.5-digit high-accuracy multimeter packaged as a C-size, 1-slot, message-based VXI module. It is electrically identical to the E1312A, differing only in mechanical size, and delivers the widest functionality in Agilent's DMM line at price points comparable to 5.5-digit instruments. The module supports a complete set of measurement functions including DC and AC voltage, DC and AC current, 2-wire and 4-wire resistance, frequency, and period.
The E1412A serves automated test system applications requiring high measurement throughput combined with precision. Its capabilities include limit checks that drive a TTL output for pass/fail testing, DC voltage ratio measurements, and on-board math operations such as NULL, MIN/MAX, LIMIT, dB, and dBm. Reading storage with internal memory supports buffered acquisition for high-speed test sequences without backplane bottlenecks during capture.
ValueTronics International operates from a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where every unit in our catalog is stored, inspected, and performance-tested by technicians before shipment. We hold inventory we sell rather than drop-ship from third parties, which means the E1412A you order is the unit our team verified against the datasheet specifications above. Buyers acquiring VXI instrumentation for system integration work need predictable lead times and accurate condition reporting, and our in-house testing process is designed to deliver both.
Agilent Technologies was spun off from Hewlett-Packard in 1999 as the company's test and measurement business. In 2014, Agilent divided again, with the electronic measurement business becoming Keysight Technologies. Agilent-branded T&M instruments such as the E1412A are part of this lineage, and calibration and service for these instruments now routes through Keysight infrastructure.
| Category | Specification | Value |
|---|---|---|
| dc Summary | dc voltage | 300 V max. |
| dc Summary | Voltage accuracy (dc) | ± 0.0019% |
| ac Summary | ac voltage | 300 V max. |
| ac Summary | Voltage accuracy (ac) | ± 0.07% |
| dc Voltage | Measurement method | Continuously integrating, multi-slope III A/D converter |
| dc Voltage | A/D linearity | 0.0002% of reading + 0.0001% of range |
| dc Voltage | Input resistance (0.1 V, 1 V, 10 V ranges) | Selectable 10 MΩ or 10 GΩ |
| dc Voltage | Input resistance (100 V, 300 V ranges) | 10 MΩ ± 1% |
| dc Voltage | Input bias current | <30 pA at 25° C |
| dc Voltage | Input terminals | Copper alloy |
| dc Voltage | Input protection | 300 V on all ranges |
| Resistance | Measurement method | Selectable 4-wire or 2-wire Ω (Current source referenced to low input) |
| Resistance | 2/4-wire Ω range | 100 MΩ |
| Resistance | Max. lead resistance (4-wire Ω) | 10% of range per lead for 100 Ω and 1 kΩ per lead on all other ranges |
| Resistance | Input protection | 300 V on all ranges |
| dc Current | Shunt resistor | 0.1 Ω for 1 A and 3 A, 5 Ω for 10 mA and 100 mA |
| dc Current | Input protection | Externally accessible 3 A, 250 V fuse |
| Noise Rejection | dc CMMR (60/50 Hz, 1 kΩ unbalance in LO lead) | 140 dB |
| Noise Rejection | Normal mode rejection (100 PLC / 10 PLC / 1 PLC) | 60 dB |
| Noise Rejection | Normal mode rejection (<1 PLC) | 0 dB |
| System Speed (DC) | Function change | 30/s |
| System Speed (DC) | Range change | 65/s |
| System Speed (DC) | Autorange time | <30 ms |
| System Speed (DC) | Max. internal trigger rate | 1000/s |
| System Speed (DC) | Max. external trigger rate to memory | 1000/s |
| ac Voltage | Measurement method | ac-coupled True RMS — measures the ac component of the input with up to 300 Vdc of bias on any range (Max ac+dc = 300 V rms) |
| ac Voltage | Crest factor | Maximum 5:1 at full scale |
| ac Voltage | ac filter bandwidth (Slow) | 3 Hz-300 kHz |
| ac Voltage | ac filter bandwidth (Medium) | 20 Hz-300 kHz |
| ac Voltage | ac filter bandwidth (Fast) | 200 Hz-300 kHz |
| ac Voltage | Input impedance | 1 MΩ ±2%, in parallel with 100 pF |
| ac Voltage | Input protection | 300 Vrms all ranges |
| ac Current | Measurement method | Direct couple to the fuse and shunt. ac-coupled True RMS measurement (measures the ac component only) |
| ac Current | Shunt resistor | 0.1 Ω for 1 A and 3 A ranges |
| ac Current | Burden voltage (1A range) | <1 Vrms |
| ac Current | Burden voltage (3A range) | <2 Vrms |
| ac Current | Input protection | Externally accessible 3 A, 250 V fuse |
| Noise Rejection (AC) | ac CMMR (1 kΩ unbalance in LO lead) | 70 dB |
| System Speed (AC) | Function or range change | 5/s |
| System Speed (AC) | Autorange time | <0.8 s |
| System Speed (AC) | ASCII reading to GPIB | 50/sec |
| System Speed (AC) | Max. internal trigger rate | 50/s |
| System Speed (AC) | Max. external trigger rate to memory | 50/s |
| Frequency/Period | Measurement method | Reciprocal-counting technique. ac-coupled input using the ac voltage measurement function |
| Frequency/Period | Voltage ranges | 100 mV rms full scale to 300 V rms. Auto or manual ranges |
| Frequency/Period | Gate time | 10 ms, 100 ms, or 1 s |
| Frequency/Period | Max. reading rate | 1K |
| Frequency/Period (System) | Configuration rates | 14/s |
| Frequency/Period (System) | Autorange time | <0.6 s |
| Frequency/Period (System) | Max. internal trigger rate | 80/s |
| Frequency/Period (System) | Max. external trigger rate to memory | 80/s |
| General | Warmup time | 1 hour |
| General | State storage memory | Power-off state automatically saved |
| Functions | Idc | 3 A |
| Functions | Iac | 3 A |
| Functions | Frequency | 300 kHz |
| Functions | Period | 3.3 µs |
| Functions | Temp. | Tm, Tc, RTD |
| VXI Characteristics | VXI device type | Message based |
| VXI Characteristics | Data transfer bus | A16 |
| VXI Characteristics | Size | C |
| VXI Characteristics | Slots | 1 |
| VXI Characteristics | Connectors | P1/2 |
| Module Current | +5 V (IPM / IDM) | 0.2 / 0.1 |
| Module Current | +12 V (IPM / IDM) | 0.7 / 0.06 |
| Module Current | -12 V (IPM / IDM) | 0 / 0 |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Agilent
Condition
Used
Manufacturer
Agilent
Ac voltage
300 V
Dc voltage
300 V
Resolution
6.5
Type
Bench
Request A Quote